You are on page 1of 1

12 mmØ @ 5" C/C top 12 mmØ @ 5" C/C bottom

10" 10"
bothway.
RL= (+)34" or As Per Arch. DWG
bothway.

10" Slab thick=6"

1'-0"
VARIABLE ( TO BE DECIDED BY SITE ENGINEER) 9'-0" WATER LEVEL Free Board=1'-0"
Road Level Road Level

PITH DEPTH 5'-3"


4'-0"
10" Thick Lift Core Wall
10 mm Ø @ 8" C/C
10" Thick Lift Core Wall
Plaster with Net
Cement Finishing

SEE SHEAR WALL SCHEDULE


10 mm Ø @ 6" C/C

6"
10 mm Ø @ 4" C/C
5'-0"

10 mm Ø @ 5" C/C

10 mm Ø @ 6" C/C
16 mmØ @ 5" C/C bothway 16 mmØ @ 5" C/C bothway
1'-3"
20"

20mmØ @ 5" C/C St (bothway)


9" 9" 12"

44"
9" 9" 9"
24"

20"

3.5" BBC or 2.5" CC

See PC5 Details(thick_44")


RL= -(8'-0")

20" 20"
LIFT & UGWR SECTION, X-X.

B C D E
2'-021" 9'-021" 6'-10"
T=44"
1'-0"

05
T=44"
6'-5"

X X
1'-0"
04
5'-1121"

03

T=44" T=44"

U.G.W.R PLAN

PROPOSED INFRASTRUCTURE BUILDER'S & MANAGEMENT DRAWING TITLES SHEET NO


CONSULTANT

"ROSE HAVEN PLACE" S.M. Kamal & Gon. L#04, H/F#04, RD#02, BL#C, Engr. Md. Waliul Islam Engr. Shekh Muhsen Uddin Ahmed Engr. Md. Bazlur Rahman
PROJECT

DESIGN BY
OWNER

CHECK BY

(G+9)TEN STORIED KAFRUL, MIRPUR-13, DHAKA. (AMIEB-19931) (AMIEB-19932) (MIEB- 33082)


Structural Engineer. Structural Engineer. Structural Engineer. UGWR LAYOUT S/13
RESIDENTIAL BLDG AT Cell:01515670988,01765588050 B.Sc Engg.(Civil), DUET B.Sc Engg.(Civil), DUET B.Sc Engg.(Civil), DUET &
CHONDRIMA MODEL E-mail: ibminfo4u@gmail.com JB No: 018_18

TOWN, DHAKA. REBAR DETAILS DATE: APR-2019