You are on page 1of 10

NICHOLSON KOVALCHICK ARCHITECTS

A S S O C I A T E S, I N C.

# REVISIONS

100% CD SET / PERMIT 05.22.13


PRICING SET 03.08.13
85% CD Set 01.15.13
COORDINATION SET 01.02.13
A MUP SUBMITTAL 05.03.12

ISSUANCE

TRIAD 12TH AVENUE


4123 12TH AVENUE NE

TRIAD CAPITAL
SEATTLE, WA 98105
SYMBOL
SCHEDULE
FILE LOCATION: X:\AES\DRAWINGS\TRIAD 12\E-0.1 TRI12 - SYMBOL.DWG

DATE: 05.22.2013
PLOTDATE: 6.11.2013

PROJECT #: 1152
DRAWN BY: RA
CHECKED BY: BR/RA
FILE NAME:
PRINTED BY: RYAN

C
E-0.1
2012 NICHOLSON KOVALCHICK ARCHITECTS PS
NICHOLSON KOVALCHICK ARCHITECTS

T
TE
A S S O C I A T E S, I N C.

T
T
T T T T T T TV TV

TV
T
T
# REVISIONS
T

100% CD SET / PERMIT 05.22.13


T

PRICING SET 03.08.13


85% CD Set 01.15.13
COORDINATION SET 01.02.13
A MUP SUBMITTAL 05.03.12

ISSUANCE
T

TRIAD 12TH AVENUE


T

4123 12TH AVENUE NE

TRIAD CAPITAL
SEATTLE, WA 98105
T

SITE PLAN
FILE LOCATION: X:\AES\DRAWINGS\TRIAD 12\E-1.0 TRI12 - SITE.DWG

DATE: 05.22.2013
PLOTDATE: 5.20.2013

PROJECT #: 1152
DRAWN BY: RA
CHECKED BY: BR/RA
SITE PLAN FILE NAME:
1/8" = 1'-0"

E-1.0
PRINTED BY: RYAN

C 2012 NICHOLSON KOVALCHICK ARCHITECTS PS


NICHOLSON KOVALCHICK ARCHITECTS

1 2 3 4 5 6

A S S O C I A T E S, I N C.

TRANSFORMER
ACCESS WELL
B15

TRANSFORMER
ACCESS WELL
B15

A A

SPRINKLER
ROOM
B04
TENANT
STORAGE
TRANSFORMER VAULT B17
B16
UP
METER STAIR A TELECOM
B18 B00 B05
# REVISIONS
TRANSFORMER
B B
VESTIBULE
B14 BICYCLE
S
PARKING
B06

DN
C S C
ELEV
UP B02 100% CD SET / PERMIT 05.22.13
PRICING SET 03.08.13
85% CD Set 01.15.13
CORR. COORDINATION SET 01.02.13
B03
A MUP SUBMITTAL 05.03.12

STAIR B ISSUANCE
B01
D D

UNIT A.2 ON A5.1


STUDIO E
B07

TRIAD 12TH AVENUE


UNIT B.4 ON A5.2
STUDIO
UNIT C.1 ON A5.3 UNIT B.1 ON A5.2 UNIT B.1 ON A5.2 UNIT B.1 ON A5.2 B09
STUDIO STUDIO STUDIO STUDIO
B13 B12 B11 B10
UNIT A.3 ON A5.1
STUDIO

4123 12TH AVENUE NE

TRIAD CAPITAL
B08

SEATTLE, WA 98105
PC

F F
PATIO PATIO PATIO PATIO PATIO UP

CANOPY ABOVE

1 2 3 4 5 6

LEVELS B1 PLAN
FILE LOCATION: X:\AES\DRAWINGS\TRIAD 12\E-2.0 TRI12 - B1.DWG

DATE: 05.22.2013
PLOTDATE: 5.20.2013

PROJECT #: 1152
DRAWN BY: RA
CHECKED BY: BR/RA
LEVEL B1 PLAN FILE NAME:
1/8" = 1'-0"

E-2.0
PRINTED BY: RYAN

C 2012 NICHOLSON KOVALCHICK ARCHITECTS PS


NICHOLSON KOVALCHICK ARCHITECTS

A S S O C I A T E S, I N C.

1 2 3 4 5 6

BENCH PER
LANDSCAPE DRAWINGS
DECORATIVE
TRANSFORMER
METAL GATE
ACCESS HATCH

METAL
GATE

P
PC
A BLDG. A
REFUSE/ STAIR A ENTRY
RECYCLING 100
AREA PC VESTIBULE
LOBBY
114 118 PC
# REVISIONS

P
BENCH
PC
UNIT B.5 ON A5.3
UNIT B.3 ON A5.2 UNIT B.2 ON A5.2 STUDIO
STUDIO STUDIO 117
PC
115 116 UP PC

BLDG.
EXIT
P 100% CD SET / PERMIT 05.22.13
PRICING SET 03.08.13
B UP B 85% CD Set 01.15.13
BATH CONCIERGE COORDINATION SET 01.02.13
120 OFFICE A MUP SUBMITTAL 05.03.12
119

12TH AVENUE NE
S ISSUANCE
S
C C
UP ELEV
102
ALLEY

UNIT A.2 ON A5.1


STUDIO
STAIR B CORR. 106

TRIAD 12TH AVENUE


101 103
D D

UNIT A.2 ON A5.1


LOBBY E
107

WINDOW WELL BELOW


E

4123 12TH AVENUE NE

TRIAD CAPITAL
SEATTLE, WA 98105
UNIT B.4 ON A5.2
STUDIO
UNIT C.1 ON A5.3 UNIT B.1 ON A5.2 UNIT B.1 ON A5.2 UNIT B.1 ON A5.2 109
STUDIO STUDIO STUDIO STUDIO
113 112 111 110
UNIT A.3 ON A5.1
STUDIO
108

F F
PATIO PATIO PATIO PATIO PATIO
UP

CANOPY
BELOW

1 2 3 4 5 6

LEVEL 1 PLAN
FILE LOCATION: X:\AES\DRAWINGS\TRIAD 12\E-2.1 TRI12 - 1ST.DWG

DATE: 05.22.2013
PLOTDATE: 5.20.2013

PROJECT #: 1152
DRAWN BY: RA
CHECKED BY: BR/RA
FILE NAME:

LEVEL 1 PLAN
E-2.1
PRINTED BY: RYAN

1/8" = 1'-0"

C 2012 NICHOLSON KOVALCHICK ARCHITECTS PS


NICHOLSON KOVALCHICK ARCHITECTS

A S S O C I A T E S, I N C.

1 2 3 4 5 6

A A
UNIT A.5 ON A5.1 # REVISIONS
STUDIO
204
UNIT D.1 ON A5.3
STUDIO
214 UNIT B.5 ON A5.3
UNIT B.2 ON A5.2 UNIT B.2 ON A5.2 STUDIO
STUDIO STUDIO 217
215 216
100% CD SET / PERMIT 05.22.13
PRICING SET 03.08.13
STAIR A UP 85% CD Set 01.15.13
200 UNIT A.1 ON A5.1 COORDINATION SET 01.02.13
STUDIO
205 A MUP SUBMITTAL 05.03.12
B B
ISSUANCE

S
C C
UP S ELEV
202 UNIT A.2 ON A5.1
STUDIO
206
CORR.
203

TRIAD 12TH AVENUE


STAIR B
201
D D

UNIT A.2 ON A5.1


STUDIO

4123 12TH AVENUE NE

TRIAD CAPITAL
207 E

SEATTLE, WA 98105
E

UNIT B.4 ON A5.3


STUDIO
UNIT C.2 ON A5.3 UNIT B.1 ON A5.2 UNIT B.1 ON A5.2 UNIT B.1 ON A5.2 209
STUDIO STUDIO STUDIO STUDIO
213 212 211 210 UNIT A.5 ON A5.1
STUDIO
208

F F

1 2 3 4 5 6

LEVEL 2 PLAN
FILE LOCATION: X:\AES\DRAWINGS\TRIAD 12\E-2.2 TRI12 - L2.DWG

DATE: 05.22.2013
PLOTDATE: 5.20.2013

PROJECT #: 1152
DRAWN BY: RA
CHECKED BY: BR/RA
FILE NAME:

LEVEL 2 PLAN
E-2.2
PRINTED BY: RYAN

1/8" = 1'-0"

C 2012 NICHOLSON KOVALCHICK ARCHITECTS PS


NICHOLSON KOVALCHICK ARCHITECTS

A S S O C I A T E S, I N C.
1 2 3 4 5 6

TELECOM
CLOSET
418
BATH

A A
CLOSET W/D
STAIR A
300

UNIT A.4 ON A5.1


STUDIO
UNIT D.1 ON A5.3 UNIT B.2 ON A5.2 UNIT B.2 ON A5.2 UNIT B.6 ON A5.3 304
STUDIO STUDIO STUDIO STUDIO
314 KITCHEN
315 316 317

UP
# REVISIONS

UNIT A.1 ON A5.1 D


B STUDIO B
305

ELEV 100% CD SET / PERMIT 05.22.13


302 PRICING SET 03.08.13
C S S
C TELE/COMM CLOSET DETAIL 85% CD Set 01.15.13
UP 1/4" = 1'-0" COORDINATION SET 01.02.13
A MUP SUBMITTAL 05.03.12
UNIT A.2 ON A5.1
STUDIO
CORR. 306 SEE UNIT A.6 ISSUANCE
303 ON SHEET A5.1
FOR UNITS 406
STAIR B + 706 ON
301 LEVELS 4 + 7

D D

UNIT A.2 ON A5.1


STUDIO E

TRIAD 12TH AVENUE


307
E

UNIT B.4 ON A5.2


UNIT C.3 ON A5.3 UNIT B.1 ON A5.2 UNIT B.1 ON A5.2 UNIT B.1 ON A5.2 STUDIO

4123 12TH AVENUE NE

TRIAD CAPITAL
STUDIO STUDIO STUDIO STUDIO 309

SEATTLE, WA 98105
313 312 311 310

UNIT A.4 ON A5.1


STUDIO
308

F F

1 2 3 4 5 6

LEVELS 3-7 PLAN


FILE LOCATION: X:\AES\DRAWINGS\TRIAD 12\E-2.3 TRI12 - L3-7.DWG

DATE: 05.22.2013
PLOTDATE: 5.20.2013

PROJECT #: 1152
DRAWN BY: RA
CHECKED BY: BR/RA
FILE NAME:

LEVELS 3-7 PLAN


E-2.3
PRINTED BY: RYAN

1/8" = 1'-0"

C 2012 NICHOLSON KOVALCHICK ARCHITECTS PS


NICHOLSON KOVALCHICK ARCHITECTS

A S S O C I A T E S, I N C.

ELEV
MECH. R02
ROOM
R05

CONTROL RM. ELEV LOBBY


R03
1 2 3 4 5 6

# REVISIONS

MECH & ELEVATOR MACHINE ROOMS PLAN 100% CD SET / PERMIT 05.22.13
1/4" = 1'-0" PRICING SET 03.08.13
85% CD Set 01.15.13
COORDINATION SET 01.02.13
A A A MUP SUBMITTAL 05.03.12

STAIR A ISSUANCE
R00

GREEN ROOF

TRIAD 12TH AVENUE


B B
ELEV S

MECH. R02
S
ROOM
R05

4123 12TH AVENUE NE

TRIAD CAPITAL
SEATTLE, WA 98105
CONTROL RM. ELEV LOBBY
R03 R04

STAIR B
R01 PC
S
D D

TENANT ROOF DECK


1626 SF

GREEN ROOF

F F

ROOF PLAN
FILE LOCATION: X:\AES\DRAWINGS\TRIAD 12\E-2.4 TRI12 - ROOF.DWG

1 2 3 4 5 6
DATE: 05.22.2013
PLOTDATE: 5.20.2013

PROJECT #: 1152
DRAWN BY: RA
CHECKED BY: BR/RA
FILE NAME:
ROOF PLAN
1/8" = 1'-0"

E-2.4
PRINTED BY: RYAN

C 2012 NICHOLSON KOVALCHICK ARCHITECTS PS


4 6

4 6
NICHOLSON KOVALCHICK ARCHITECTS

D
CLOSET
BATH
KITCHEN

BATH A S S O C I A T E S, I N C.

KITCHEN
W/D
W/D T
LIVING ROOM/
BATH LIVING ROOM/ W/D BEDROOM
BEDROOM

KITCHEN

CLOSET T
C

COLUMN LOCATIONS
AT LEVEL 2
HEATER UNITS
110, 111, 112, 210, 211, 212, 213, 215, 216,
LIVING ROOM/ 310, 311, 312, 315, 316, 410, 411, 412, 415,
BEDROOM
UNIT A.2 - STUDIO 416, 510, 511, 512, 515, 516, 610, 611, 612,
UNIT A.1 - STUDIO - TYPE A
HEATER UNITS 1/4" = 1'-0" HEATER UNITS T 615, 615
1/4" = 1'-0" 107, 206, 207, 306, 307, 406, 407, 506, 507, 606, 607
205, 305, 405, 505, 605
B09, B10, B11, B12, 109, 209, 309, 409,
106, 706, 707

CLOSET
705 509, 609, 710, 711, 712, 715, 716

B08, 108, 208, 308, 408, 508, 608,708 204 709 # REVISIONS

B07, 304, 404, 504, 604, 704 115, 116

- DRYER BOOSTER FAN (DBF-1) LOCATED IN UNIT 115 ONLY 100% CD SET / PERMIT 05.22.13
PRICING SET 03.08.13
UNIT B.1 - STUDIO 85% CD Set 01.15.13
- PATIO WALL SCONCE USED ON BASEMENT LEVEL UNITS &
1/4" = 1'-0" UNITS 115-117 ONLY. COORDINATION SET 01.02.13
A MUP SUBMITTAL 05.03.12

ISSUANCE

3 1

TRIAD 12TH AVENUE


A
1
CLOSET

4123 12TH AVENUE NE

TRIAD CAPITAL
SEATTLE, WA 98105
D

A A
T

LIVING ROOM/ CLOSET


LIVING ROOM/ BEDROOM
BEDROOM

BATH
CLOSET

KITCHEN
KITCHEN W/D

W/D KITCHEN

W/D T

BATH

BATH
LIVING ROOM/ B
BEDROOM

TYPICAL UNIT
PLANS
FILE LOCATION: X:\AES\DRAWINGS\TRIAD 12\E-3.0 TRI12 - UNITS.DWG

UNIT B.5 - STUDIO HEATER UNITS DATE: 05.22.2013


UNIT C.3 - STUDIO HEATER UNITS UNIT D.1/D.2 - STUDIO HEATER UNITS
1/4" = 1'-0" 217
PLOTDATE: 6.11.2013

1/4" = 1'-0" PROJECT #: 1152


113, 213, 313, 413, 513, 613 1/4" = 1'-0" 314, 414, 514, 614, 714
DRAWN BY: RA
317, 417, 517, 617, 717,
B13, 713 214 CHECKED BY: BR/RA
FILE NAME:
117
- PATIO WALL SCONCE USED ON BASEMENT
LEVEL UNITS & UNITS 115-117 ONLY.
- PATIO WALL SCONCE USED ON BASEMENT

E-3.0
LEVEL UNITS & UNITS 115-117 ONLY.
PRINTED BY: RYAN

C 2012 NICHOLSON KOVALCHICK ARCHITECTS PS


NICHOLSON KOVALCHICK ARCHITECTS

A S S O C I A T E S, I N C.

# REVISIONS

100% CD SET / PERMIT 05.22.13


PRICING SET 03.08.13
85% CD Set 01.15.13
COORDINATION SET 01.02.13
A MUP SUBMITTAL 05.03.12

ISSUANCE

TRIAD 12TH AVENUE


4123 12TH AVENUE NE

TRIAD CAPITAL
SEATTLE, WA 98105
FILE LOCATION: X:\AES\DRAWINGS\TRIAD 12\E-4.0 TRI12 - POWER RISER.DWG

DATE: 05.22.2013
PLOTDATE: 5.20.2013

PROJECT #: 1152
DRAWN BY: RA
CHECKED BY: BR/RA
FILE NAME:

E-4.0
PRINTED BY: RYAN

C 2012 NICHOLSON KOVALCHICK ARCHITECTS PS


NICHOLSON KOVALCHICK ARCHITECTS

A S S O C I A T E S, I N C.

# REVISIONS

100% CD SET / PERMIT 05.22.13


PRICING SET 03.08.13
85% CD Set 01.15.13
COORDINATION SET 01.02.13
A MUP SUBMITTAL 05.03.12

ISSUANCE

TRIAD 12TH AVENUE


4123 12TH AVENUE NE

TRIAD CAPITAL
SEATTLE, WA 98105
FILE LOCATION: X:\AES\DRAWINGS\TRIAD 12\E-4.0 TRI12 - POWER RISER.DWG

DATE: 05.22.2013
PLOTDATE: 5.20.2013

PROJECT #: 1152
DRAWN BY: RA
CHECKED BY: BR/RA
FILE NAME:

E-4.1
PRINTED BY: RYAN

C 2012 NICHOLSON KOVALCHICK ARCHITECTS PS