You are on page 1of 70

Single line progressive Systems

JSG 2004 - 3 1
Lincoln has two types of Single
Line progressive systems
®
Modular Lube and®Quicklub
Both can use oil or grease and is of
the positive displacement design
proportioned through divider blocks.
Because of the unique Divider Valves
these systems may be used on all
types of industrial machinery.

JSG 2004 - 3 2
®
Introduction to Modular Lube

Modular Lube is:


A single-line progressive system. This
system can use oil or grease and is
of the positive displacement design
proportioned through divider blocks.
Because of the unique Modular Lube
Divider Valves this system may be
used on all types of industrial
machinery.
JSG 2004 - 3 3
Built In Design Options
Š When new technology calls for
design alterations, the system
designer can add or delete
lubrication points without disturbing
existing piping.

JSG 2004 - 3 4
Economical

Š Lincoln’s Modular Lube single-line


progressive system requires less
piping and lower tubing costs at
installation - and cost less to
maintain or change when the need
arises.

JSG 2004 - 3 5
Engineering - External Cross
Port Kit

Š This unique feature enables design


engineers to extend any Lincoln
Modular Lube System by simply
removing the by-pass block and
replacing it with a metering valve.

JSG 2004 - 3 6
Modular Lube Divider Valve

JSG 2004 - 3 7
Central Signaling
Š If a malfunction should occur due
to:
„ Broken air line
„ Low lubricant level
„ High pressure
„ Line Blockage
The system will >

JSG 2004 - 3 8
Central Signaling

„ The Modular Lube Automatic System


Controls can be configured to signal the
operator with a visual or audible alarm,
and interlock contacts activate a
machine shut-down.

JSG 2004 - 3 9
Safety Designs

Š Through the patented interlock


design.
Š Here are two units that are available.
Š Visual Audible

JSG 2004 - 3 10
Versatile

Š Divider Valves, Pump Reservoirs and


Controls can:
„ Be tailored to suit individual needs
„ Tailored for special requirements
„ Reduce inventory by purchasing
modular components.

JSG 2004 - 3 11
Manufacturing
Š Most of the valves are made in St.
Louis and have extremely tight
tolerances!

Quiz
How tight are our tolerances?

JSG 2004 - 3 12
Manufacturing Tolerances

Š Lincoln has the tightest tolerances


in the industry. (.000005)

Š Watertight

JSG 2004 - 3 13
Advantages

Š Single point monitoring


Š Positive displacement
Š High pressure
Š Oil or Grease
Š Tamper proof metering valves
Š Accepts continuous flow

JSG 2004 - 3 14
Disadvantages

Š No external adjustment at each


point.
Š Large systems are difficult to install.
Š Not easy to expand or install.
Š Difficult to troubleshoot and repair.
Š More complex in design and
operation than a parallel system.

JSG 2004 - 3 15
Applications

Š Foundry
Š Metal Cutting
Š Canning Industry
Š Machine applications for the Gas
and Oil market.

JSG 2004 - 3 16
Applications

Š Metal forming
Š Printing
Š Mining

JSG 2004 - 3 17
Applications

Š Develop your own list and share


Š ________________________________
Š ________________________________
Š ________________________________
Š ________________________________
Š ________________________________
Š ________________________________
JSG 2004 - 3 18
UV Divider Valves

Š Types of systems
„ Automatic
„ Manual

JSG 2004 - 3 19
UV Divider Valves
Š Meters

„ Oil
„ Grease NLGI 1, (preferably)
„ Can handle NLGI 2

JSG 2004 - 3 20
UV Divider Valve Specifications

Š Max lube points - 16 per assembly

Š Has performance indicators

Š Has maximum Operating Pressure of


3500/240 bar.

JSG 2004 - 3 21
UV Divider Valve Specifications

Š Performance indicator port,


right/side indicator.
Š Has multiple thread designs

Š Zinc plated steel

Š Oil or grease
JSG 2004 - 3 22
UV Divider Valve Specifications
Š Single and twin outlet for varying
volume output.

Š May utilize Bypass Block - with


mounting screws and Buna-N-Seals.

Š Base plate and tie rods

JSG 2004 - 3 23
MC Divider Valve

JSG 2004 - 3 24
MC Divider Valves

Š Dispenses petroleum based or


synthetic lubricants - gas engine and
compressor lubrication system.
Š Baseplate components - Viton
gasket.

JSG 2004 - 3 25
MC Divider Valves

Š Contains alternate ports on front


face of the divider valve, for
performance indicators, and tie rods
for baseplate.

JSG 2004 - 3 26
MC Divider Valves

Š Higher pressure 6000/410 bar


Š Note: Baseplate information
maximum of 16 outlets.
Š Lubricant output can be variable
due to the single and twin outlets.

JSG 2004 - 3 27
XL Divider Valve

JSG 2004 - 3 28
XL Divider Valve

Š Same as MM valve except it provides


large volumes of oil or grease up to
.300 cu. in. per cycle.

Š Only has 12 maximum lube points


per assembly.

JSG 2004 - 3 29
Accessories for Valves

Š Cross port plates


Š Mounting brackets

JSG 2004 - 3 30
Accessories for Valves

Š Proximity switch
Š External singling/cross port kit
Š Balancing valve

JSG 2004 - 3 31
Accessories for Valves

Š Ball type, straight


Š Ball and poppet, 90°

JSG 2004 - 3 32
Accessories for Valves

Š Check Valves - Double ball, straight


Š Ball & Poppet, straight

JSG 2004 - 3 33
Valve Operation

JSG 2004 - 3 34
Divider Valve Operation

JSG 2004 - 3 35
Divider Valves

Š Stage 1

JSG 2004 - 3 36
Divider Valves

Š Stage 2

JSG 2004 - 3 37
Divider Valves

Š Stage 3

JSG 2004 - 3 38
Divider Valves

Š Stage 4

JSG 2004 - 3 39
Modular Pumps

Reciprocating
Š Rotary - driven hydraulic pump
Š FlowMaster
Š 55 gal., 18 gal., 8 gal., or 5 gal.
85491

JSG 2004 - 3 40
Pump to Point Lubricators

Š Pump to point lubricators

JSG 2004 - 3 41
Pump to Point Lubricators

Š End Rotary Drive Lubricators


Š 8000037
Š 37.5:1 ratio
Š RH
Š Max 5 pumps
Š Up to 7 on other models

JSG 2004 - 3 42
Pump to Point Lubricators
Š Pump Model 55i

Š Fit most mfg. Boxes

Š One piece pump body

JSG 2004 - 3 43
Pump to Point Lubricators

Š Models/Styles offered configurations


Š End
Š Internal Ratchet
Š Right/Left
Š Rear

JSG 2004 - 3 44
Pump to Point Lubricators

Š Accessories
„ Armored Sight Glass Kit
„ Lube Sentry
„ Oil Level Regulator
„ Lubricator Flow Switch

JSG 2004 - 3 45
System Controls

Š Solid state timers


Š AC/DC Power Sources
Model 84501 Model 84511
Economy

JSG 2004 - 3 46
System Controls

Š Lubrication System Controllers


Š SYSTEM SENTRY II
85530 85500

JSG 2004 - 3 47
System Controls

Š SATELLITE MONITOR - SENSOR


BOARD
Š Filters, regulators, lubricators,
solenoid valves, alarms, gauges and
etc.

JSG 2004 - 3 48
Review of Modular - Lube

Š Single-Line Progressive
Š Oil or Grease
Š Add systems economically
Š Extend system - By pass block -
replace with metering valve
Š Modular concept
Š Centralized Signaling
JSG 2004 - 3 49
Review of Modular - Lube

Add to the list:


1.___________________________
2.___________________________
3.___________________________
4.___________________________
5.___________________________

JSG 2004 - 3 50
Positive Stall

If a lubricating line plug clogs:


Due to the close design tolerances of
the piston and valve in the valve
body, the system will shut down
when blockage occurs, and has a
alarm system to notify the operator.

JSG 2004 - 3 51
QUICKLUB - Progressive Metering
Device
for Grease & Oil
Type SSV

JSG 2004 - 3 52
SSV Metering Device

JSG 2004 - 3 53
Lubricant Flow within the
SSV

Phase Phase
1 2

Phase Phase Phase


3 -3
JSG 2004 4 54 5
Animation System Animation SSV
Examples of the combination of
outlets

X - Outlet closed ← Outlet open

IMPORTANT: Never close outlets 1&


JSG 2004 - 3 2 55
Connections: Treaded
1- Inlet fitting

2- Delivery hole of the piston

3- Closure plug (M 10 x 1), with installed


copper washer (old)

4- Closure plug (new M 11 x 1, old R 1/8“),

6- Valve body with clamping ring (brass)

7- Ferrule

8- Coupling nut

9- Junction channel

10 - New outlet closure plug with hex. socket


head and sealing edge, replacement for
pos. 3
JSG 2004 - 3 56
Connections:
Quicklink
Secondary
Main Divider
Divider

Reinforced Knurled
gripping gripping
piece piece

1 - Inlet fitting with protective cap 5 - Valve body assembly


2 - Delivery borehole of the piston 6 - Junction channels

3 - Closure plug (M 10 x 1) 7 - New outlet closure plug with hex. socket

4 - Piston closure plug (new M 11 x 1, old R1/8“), head and sealing edge, replacement for
pos. 3
JSG 2004 - 3chamfer
with 57
Electrical Monitoring
Device

Piston detector for


microprocessor control

JSG 2004 - 3 58
Sectional
View

Piston
detector

Piston Outlet side


side

JSG 2004 - 3 59
Piston Detector with
Plug
Plug

LED

M11x1

JSG 2004 - 3 60
Check Valve -
Quicklink

Check valve with reinforced Check valve with knurled


gripping piece and hose stud gripping piece and plastic
for high pressure tube for low pressure
(Main Divider) (Secondary Divider)

JSG 2004 - 3 61
High-pressure Plastic Hose

1 - Threaded sleeve 1 - Threaded sleeve


2 - High-pressure plastic hose 2 - High-pressure plastic hose
3 - Hose stud 3 - Adjustment gauge 432-
23077-1

JSG 2004 - 3 62
Single Parts of the Check Valve -
Threaded

1 - Coupling nut
2 - Ferrule
3 - Valve body with seal and clamp
ring
JSG 2004 - 3 63
Connectors,
Quicklink

A = Check valve with reinforced gripping


piece
B = Check valve with knurled gripping piece
1a = Reinforced gripping
1b = Seal
2a = Knurled gripping

JSG 2004 - 3 64
Pressure
Loss

PA - Pressure loss, high-pressure plastic hose between pump and main metering
device
PB - Pressure loss, main metering device
PC - Pressure loss, high-pressure plastic hose
between main and secondary metering device
PD - Pressure loss, secondary metering device
PE
JSG-2004
Pressure
-3 loss, plastic hose between
65 secondary metering device and lube
point
Pressure
Loss
Lubricant consistency Max. pressure loss w. pipe 6 x 1.5 mm (ND 3 mm)

Temperature 0° C 15° C 25° C

NLGI 0 5 bar/m 4 bar/m 2,5 bar/m


NLGI 1 8 bar/m 7 bar/m 5 bar/m
NLGI 2 12 bar/m 8 bar/m 6 bar/m
Maximum pressure loss through SSV 6 to SSV 12
NLGI 0 20 bar 15 bar 10 bar
NLGI 1 25 bar 20 bar 15 bar
NLGI 2 30 bar 25 bar 20 bar

The values of the pressure loss with 8.6 x 2.3 mm (ND 4 mm) hose are
lower.

JSG 2004 - 3 66
Flanged Metering Device Type SSV-
FL K
Technical Data

- Output per outlet and stroke


0.2 cm³
- Max. operating pressure
300 bar
- Min. operating pressure
20 bar
- Max. differential pressure
between two outlets
100 bar
- Operating temperature
25º C to 70º C

JSG 2004 - 3 67
Flanged Metering Device Type SSV-
FL K
Closure Plug
Arrangment
The outlet following the closure plug in the delivery
sequence receives double the lubricant output.
Exceptions:
SSV-FL1: Outlet 2 receives 6x the lubricant output
SSV-FL2: Outlets 1 & 2 each receive 3x the lubricant
output
SSV-FL3: Outlets 1,2 & 5 each receive 2x the lubricant
output

JSG 2004 - 3 68
 Cost-effective, reliable progressive metering device
 No seals needed
 Differential pressure of up to 100 bar possible
 SSV - K for visual monitoring of function
 SSV - N for electrical monitoring of function
 With SSVs never close outlets 1 & 2
 With Older versions SSV 14 to SSV 22 never close the outlets with the
highest outlet number

JSG 2004 - 3 69
 Don‘t forget the clamping ring with check valves (threaded
connection)

 Tolerance between piston and borehole =2µ

 Max. Flow: ≈ 3 cycles/sec.

 Pressure loss through SSV bei 0° ⇒ ≈ 30 bar for grease NLGI - 2

 Max. ambient temperature: SSV - K ⇒ ≈ 80° C


SSV ⇒ ≈ 100° C

 Better corrosion protection due to black chromate treated surface

JSG 2004 - 3 70
Layout

You might also like