CHAPTER – I – Proposal & Basis of Design

Basis of Design

Inside & Outside conditions for the System Proposed

Inside Design conditions : 76 +/-1 deg F


Outside Design conditions : 99 deg F DB, 78 deg F WB
Total Ht. Up to Ceiling : 100 Feet
Lighting Load (KW) : 1.5 Watts / Sqft
Fresh Air : One air change/hour
Power Supply : 415V/3ph/50Hz

Capacity of Air Condition.

Third Floor
1. Meeting room - 155 Sft - 10 People - 1.5 Tr Capacity
2. MD Cabin - 303 Sft - 4 People - 2.0 Tr Capacity
3. CEO Cabin - 163 Sft - 4 People - 1.5 Tr Capacity

Fourth Floor

1. Conference Room – 529 Sft – 20 People - 1821CFM - 4.0 Tr Capacity.


OPTION - 01

Sl No DESCRIPTION UNIT QTY RATE AMOUNT


1 Carrier make cassette type Split Air
conditioner with R 410 A
Refrigerant
a 1.5 TR (3 Star) Nos 2

b 2.0 TR (2 Star) Nos 1

c 4.0 TR Nos 1
SUB TOTAL
VAT

TOTAL AMOUNT INCLUDING TAXES


2 ANCILLARY WORKS
a Soft drawn Copper Piping between RM 40
Indoor to Outdoor Unit with
Nitrile rubber Insulation @ 10 Rmt /
Ckt
b Heavy class PVC drain piping (25mm RM 40
Dia)
c Installation of Indoor Units
Cassette Nos 4
d Control Cabling PVC insulated copper RM 60
conductor control cables
e 150 MM Dia PVC Pipe with Flexible RM 20
Duct from Cassette for Fresh
Air
f Condensing Unit Stand Nos 4
SUB TOTAL
GST

TOTAL AMOUNT INCLUDING TAXES


TOTAL FOR AIR CONDITIONING
SYSTEM
OPTION - 02

Sl No DESCRIPTION UNIT QTY RATE AMOUNT


1 Toshiba make stable power inverter
cassette type Split Air conditioner
cooling only with R 410 A
Refrigerant
a 1.6 TR (5 Star) Nos 2

b 2.4 TR (5 Star) Nos 1

c 4.0 TR Nos 1
SUB TOTAL
VAT

TOTAL AMOUNT INCLUDING TAXES


2 ANCILLARY WORKS
a Soft drawn Copper Piping between RM 40
Indoor to Outdoor Unit with
Nitrile rubber Insulation @ 10 Rmt /
Ckt
b Heavy class PVC drain piping (25mm RM 40
Dia)
c Installation of Indoor Units
Cassette Nos 3
Hiwall No 1
d Control Cabling PVC insulated copper RM 60
conductor control cables
e 150 MM Dia PVC Pipe with Flexible RM 20
Duct from Cassette for Fresh
Air
f Condensing Unit Stand Nos 4
SUB TOTAL
GST

TOTAL AMOUNT INCLUDING TAXES


TOTAL FOR AIR CONDITIONING
SYSTEM