Professional Documents
Culture Documents
Contents / Indhold
VESTAS PROPRIETARY NOTICE: This document contains valuable confidential information of Vestas Wind Systems A/S. It is protected by copyright law as an unpublished work. Vestas reserves all patent, copyright, trade secret, and
other proprietary rights to it. The information in this document may not be used, reproduced, or disclosed except if and to the extent rights are expressly granted by Vestas in writing and subject to applicable conditions. Vestas
disclaims all warranties except as expressly granted by written agreement and is not responsible for unauthorized uses, for which it may pursue legal remedies against responsible parties.
Document number:
PROCESS SPECIFICATION 0023-1269
Title: Approved date Revision Page of
MOUNT TOWER LADDER W. SAFETY WIRE 07 2 38
‘Vestas' Corporate OH&S Manual’ and doc- ”Vestas Corporate OH&S manual” og
uments holding specific turbine safety in- dokumenter omhandlende specifikke turbine
structions for the relevant turbine type Fur- sikkerhedsinstruktioner for den relevante type
thermore, follow local rules and regulations / turbine. Følg herudover lokale regler og
legislation. lovgivning.
Safety equipment
Sikkerhedsudstyr
FD
WARNING
ADVARSEL
-1
90
1.2 Education and Training requirements 1.2 Krav til uddannelse og træning
The technician must have completed the Medarbejderen skal have gennemgået
“Basic Safety Training” conducted by People People & Cultures grundlæggende
4-
and Culture. The technician must possess sikkerhedstræning. Medarbejderen skal have
the knowledge of wind turbine type and also kendskab til turbine typen, samt have læst og
04
For all temporary generators, the generator For alle midlertidige generatorer skal den
neutral shall be securely bonded to the gen- neutrale ledning være sikkert forbundet til
erator earth bar. The generator earth bar generatorens jordingsbarre. Generatorens
shall be securely bonded to a reliable earth- jordingsbarre skal være sikkert forbundet til et
R
reliable building or turbine earth is not avail- jordingspunkt. Hvor dette ikke er muligt, skal
able, an earthing rod shall be driven into the jording foregå via et jordings spyd, der
ground next to the generator. fastsættes i jorden ved siden af generatoren.
-1
ed to the generator shall require an equip- forbundet til generatoren kræver tilslutning af
ment protection earth conductor from the en beskyttelses jordingsleder fra generatoren
generator to the final utilisation equipment. til det anvendte udstyr. Jordingslederen skal
4-
The earth conductor shall be bonded to kun være forbundet til generatorens
MANDATORY
earthing point at the generator only. Metal jordingspunkt. Metal afskærmninger for
04
enclosures for intermediate distribution box- mellemliggende fordeler bokse skal også
es shall also be bonded to the earthing con- være forbundet til jordingslederen.
ductor.
2
All utilisation equipment powered from tem- Alle anvendte udstyr der drives af midlertidige
porary electrical installations shall be pro- elektriske installationer skal være beskyttet
tected with GFCI’s (Ground Fault Current med HPFI relæ’er. Transportable HPFI
Interrupters) or RCD’s (Residual Current De- relæ’er skal være installeret imellem fordeler
vices). Portable GFCI’s or RCD’s shall be panelet og det midlertidige kabel, der driver
installed between the distribution panel and det anvendte udstyr.
the temporary cable feeding the utilisation
equipment.
Local electrical engineering expertise shall Man skal rådføre sig med lokal el installatør
be consulted to obtain detailed specifications for at fastlægge detaljerede specifikationer for
for proper earthing techniques, materials, korrekte jordingsteknikker, materialer og
and GFCI’s/RCD’s. HPFI relæ’er
Document number:
PROCESS SPECIFICATION 0023-1269
Title: Approved date Revision Page of
MOUNT TOWER LADDER W. SAFETY WIRE 07 4 38
based on that the following Vestas de- at følgende Vestas designet specialværktøj
signed special tool is used: anvendes:
- VT620467-001, Measuring tool for mag- - VT620467-001, Måleværktøj for
4-
nets. magneter.
- VT620519, Hand grip for dismount mag- - VT620519, Håndtag for afmontering af
04
nets. magneter
2
Document number:
PROCESS SPECIFICATION 0023-1269
Title: Approved date Revision Page of
MOUNT TOWER LADDER W. SAFETY WIRE 07 5 38
Be aware of serious squeezing risk when Vær opmærksom på alvorlig fare for
handling magnets. Unpack magnets one by klemning når magneter håndteres. Pak
one and keep clear of metal objects. magneterne ud enkeltvis og hold afstand
Do not place any part of body between til genstande af metal.
magnet and tower when magnets are Anbring ingen legemsdele mellem magnet
attached to tower. og tårn, når magnet sættes på tårn.
R
FD
Magnets also affect pacemakers !!!. Magneter påvirker også pacemakere !!!.
-1
similar anti seize compound – fx. “Rocol tilsvarende smøremiddel – f.eks. “Rocol
Anti-seize Compound”. Anti-seize Compound”.
4-
04
2
Copper grease /
Kobberfedt
Document number:
PROCESS SPECIFICATION 0023-1269
Title: Approved date Revision Page of
MOUNT TOWER LADDER W. SAFETY WIRE 07 6 38
Be aware of the high risk of falling when Vær opmærksom på den høje risiko for at
walking around inside the tower section. falde når man går rundt inden i tårn
Pay special attention to the walls which are sektionen. Vær særlig opmærksom på, at
always slippery. tårnvæggene altid er glatte.
R
FD
5.1 When mounting of ladder legs, mounting 5.1 Ved montering af stigeben anvendes
Tool, measuring tape and laser are used. montageværktøj, målebånd og laser.
-1
VT620467-001
90
4-
04
2
5.2 The centre line for the ladder is found. 5.2 Midterlinien for stigen findes.
Never look directly into the laser beam. Se aldrig direkte ind i laserstrålen!
Never point a laser beam at a person. Peg aldrig med laserstrålen på personer!
Do not aim the laser at reflective surfaces. Peg aldrig med laserstrålen på reflekte-
rende overflader!
R
5.3 A measuring tape is rolled out in the sec- 5.3 Et målebånd rulles ud i sektionen. Alle
tion. All dimensions shall be taken from the dimensioner skal udmåles fra den øverste
FD
upper flange in the section, except for the flange i sektionen, med undtagelse af
top section where the dimensions shall be topsektionen hvor dimensionerne skal
taken from the lowest flange in the section. udmåles fra den nederste flange i
-1
5.4 Ladder legs are placed in the section. 5.4 Stigeben placeres i sektionen.
Top section:
FD
6.1 Grate tray is placed in the section and as- 6.1 Gitterbakke placeres i sektionen og samles
04
Note: Do not deform the ladder by over Note: Bolte gennem stige ben må ikke
tightening of bolts through ladder legs. overspændes, så stigen deformeres.
-1
90
4-
04
2
MANDATORY
7.3 Assembly order for ladder suspension on plat- 7.3 Samlingsrækkefølge for stigeophæng på
form in both sides of the ladder: platform i begge sider af stigen:
1) Upper bolt is tightened before the lad- 1) Øverste bolt spændes før stigen
der is mounted in the section. The low- monteres i sektionen. Den nederste
er bolt (3) is mounted loose. bolt (3) monteres løseligt.
2) The ladder is mounted in the section 2) Stigen monteres i sektionen og
and the bolts against the platform are boltene mod platformen spændes.
tightened. 3) Den nederste bolt spændes.
3) The lower bolt is tightened.
R
FD
1
-1
90
4-
2
MANDATORY
04
2
3
Document number:
PROCESS SPECIFICATION 0023-1269
Title: Approved date Revision Page of
MOUNT TOWER LADDER W. SAFETY WIRE 07 12 38
7.4 Mount ladder suspension brackets at the top 7.4 Montér stige ophængs beslag ved top
platform. Make sure the rubber patches is platform. Det skal sikres at gummilapperne
fixed between the ladder brackets and plat- er fastgjort mellem stigebeslag og platform,
form in order to ensure that the top platform is således at top platformen er olietæt skal.
oil tight.
Rubber patches is fixed at delivery /
Gummi lapper er fastgjorte fra levering
R
FD
-1
7.5 Mount angular brackets in bottom of ladder. 7.5 Monter vinkelbeslag nederst på stigen.
Fasten the brackets in top position in a way Fastgør beslag i øverste position, så
90
7.6 Mount brackets for HV-cable. Positions refer- 7.6 Monter beslag for HV-kabel. Position
ring to drawing. fremgår af tegning.
04
2
7.5 7.6
Document number:
PROCESS SPECIFICATION 0023-1269
Title: Approved date Revision Page of
MOUNT TOWER LADDER W. SAFETY WIRE 07 13 38
7.7 Mount Yellow/Green grounding cable on angu- 7.7 Monter gul/grøn jordingskabel på vinkel-
lar brackets in bottom of ladder beslag nederst på stigen.
7.8 Secure the ladder in the bottom section for 7.8 Stigen i bund sektionen sikres for transport
transport by lashing the ladder to the middle ved hjælp af fast surring til midter hullet i i
hole in the bottom of the flange as shown on bunden af flangen som vist på billedet
-1
The lashing bracket has to be placed between to trin og det ekstra bånd skal rulles op og
the two steps and the extra lashing band is fastgøres med strips
coiled up with a cable binder
04
20 mm.
2
Document number:
PROCESS SPECIFICATION 0023-1269
Title: Approved date Revision Page of
MOUNT TOWER LADDER W. SAFETY WIRE 07 14 38
The bottom platform is grounded just as the lift Bund platformen jordes ligesom lift
landing platform with a wire between ladder platformen med wire mellem stige og
2
9.2 Install ladder rung support on each rung 9.2 Indsæt trin forstærkninger i trin, hvorpå
90
whereto brackets and guides are clamped (as opspænding skal foretages (som vist ved
shown with arrows in picure below). pile på nedenstående billede).
Remember to lock the rung supports with Husk at låse trin forstærkningerne med
4-
cotter pins on each side of the ladder. splitter på begge sider af stigen
04
Cotter pin
2
RUNG SUPPORT
9.3 Mount top bracket in top sections above the 9.3 Montér top beslag I top sektioner over top
Document number:
PROCESS SPECIFICATION 0023-1269
Title: Approved date Revision Page of
MOUNT TOWER LADDER W. SAFETY WIRE 07 16 38
Rung supports are placed from the top of the Trin forstærkere placeres fra toppen af
ladder inside rungs: stigen i trin:
1-3 1-3
Mount the top bracket in the middle of the Topbeslaget monteres midt på stige trinne-
ladder rungs and aligned to the ladder legs. ne og oprettet i forhold til stige benene.
Torque nuts with 16.3-17.6 Nm and mark for Spænd møtrikker med 16.3-17.6 Nm og
tightening with crosses afterwards. opmærk efterfølgende med kryds for
Be aware that bolts always are to be pointed fastspænding.
in opposite direction of the user. Vær opmærksom på at bolte altid skal
vende væk fra brugeren.
R
FD
-1
90
4-
04
2
Document number:
PROCESS SPECIFICATION 0023-1269
Title: Approved date Revision Page of
MOUNT TOWER LADDER W. SAFETY WIRE 07 17 38
9.4 Connect the steel cable to the top bracket. 9.4 Fastgør stål wiren til top beslaget.
Use protective glasses and gloves when Anvend beskyttelses- briller og handsker,
uncoiling the steel cable. The cable is stiff and når kablet skal rulles ud. Kablet er stift og
may spring out of the coil unexpectedly. kan derfor bevæge sig uhensigtsmæssigt.
1. Inspect the steel cable for damage and 1. Inspicer stål wiren for skader og vær
make sure it is OK for usage. sikker på at den er OK for brug.
2. First pull a short end of the steel cable 2. Træk først et kort stykke af stål wiren
through the pipe. gennem røret.
R
3. Ensure end of the carrier cable is free of 3. Sikre at stål wiren er fri for beskadelser
kinks and unraveled strands. og lus.
FD
4. Pass the carrier cable to shock absorber, 4. Montér stød dæmperen og bære
carrier lug and washer down through the stykket med skive på stål wiren og ned
Top bracket pipe gennem røret
-1
2
4-
04
2
Document number:
PROCESS SPECIFICATION 0023-1269
Title: Approved date Revision Page of
MOUNT TOWER LADDER W. SAFETY WIRE 07 18 38
R
FD
-1
90
4-
04
5. Seat the carrier lug into shock absorber by 5. Før bærestykket ind i støddæmperen
pulling firmly on carrier lug below the top ved at trække i stålwiren under røret i
bracket pipe. topbeslaget.
2
9.5 Mount the cable guides in the middle of the 9.5 Montér kabel styrene midt på stige trinnet.
ladder rungs. Max. distance between the cable Maximale afstand mellem kabel styrene må
guides are 8 m. Fasten nuts with 1.5-2.5 Nm være 8 m. Spænd møtrikker med 1.5-2.5
and mark for tightening with crosses after- Nm og opmærk efterfølgende med kryds for
wards. fastspænding.
R
FD
9.6 Mount the bottom bracket on ladders in all 9.6 Montér bundbeslaget på stiger i alle
sections. sektioner.
90
Mount the bottom bracket in the middle and on Montér bund beslaget midt på trin 2 og 3 fra
rungs 2 and 3 from the bottom of the ladder. bunden af stigen. Spænd møtrikker med
Fasten nuts with 16.3-17.6 Nm and mark for 16.3-17.6 Nm og opmærk efterfølgende
4-
1 2-3
-1
90
4-
9.10 Fix the steel cable to the ladder with cable 9.10 Fiksér stål wiren til stigen med strips for
ties for every 5th rung. hver 5. trin.
R
FD
-1
90
4-
04
2
Document number:
PROCESS SPECIFICATION 0023-1269
Title: Approved date Revision Page of
MOUNT TOWER LADDER W. SAFETY WIRE 07 22 38
Ensure that the cable does not abrade Check at wiren ikke kan nedslides
gainst the structure at any point. imod strukturen på nogen steder
overhoved-et.
4-
04
2
Document number:
PROCESS SPECIFICATION 0023-1269
Title: Approved date Revision Page of
MOUNT TOWER LADDER W. SAFETY WIRE 07 23 38
step to the flange plan “Z” (see drawing). flangeplanet ”Z” (se tegning).
R
FD
-1
90
4-
04
2
Document number:
PROCESS SPECIFICATION 0023-1269
Title: Approved date Revision Page of
MOUNT TOWER LADDER W. SAFETY WIRE 07 24 38
11.2 Check that the swing gate can move freely after 11.2 Check at svinglågen kan bevæge sig frit, efter at
mounting of the section has been complete montage af sektionen er færdiggjort
04
2
11.3 Ground the swing gate with two screws 11.3 Jordforbindelse til svinglågen skabes via to
through the platform skruer gennem platformen
a. Remove rubber sealing underneath the a. Fjern gummi pakningen nedenunder bund
FD
e. Fasten the swing gate to the platform with e. Svinglågen fæstnes til platformen med to
two self-tapping screws selvskærende skruer.
4-
04
2
Document number:
PROCESS SPECIFICATION 0023-1269
Title: Approved date Revision Page of
MOUNT TOWER LADDER W. SAFETY WIRE 07 26 38
c. Mount cable loop above the platform. c. Mount kabel loop over platformen. Låse
4-
stalled)
FD
Start of Grate tray is in general measured from the assembly between the sections /
flange and in accordance with drawing measures / Ekstra gitterbakke fastgøres med 2 strips for
Start af kabelbakker opmåles generelt fra flangen samling mellem sektionerne
90
16.2 Grate trays are assembled with brackets 16.2 Gitterbakke fastgøres med beslag og
4-
the connecting piece (see picture c and d). / mellemrum af samlingsstykket som vist på
billede c og d.
FD
a. b.
-1
90
4-
04
c. d
2
The connection is made with two bolts and Fastgørelsen sker med to bolte og
large washers. skærmskiver.
R
FD
-1
90
4-
04
2
Document number:
PROCESS SPECIFICATION 0023-1269
Title: Approved date Revision Page of
MOUNT TOWER LADDER W. SAFETY WIRE 07 32 38
16.4 Mounting of rotation retainer at ladder 16.4 Montage af samlede rotations holder ved
bottom end in the top section stige bund i topsektion
R
17.1 Anchor point in the top section 17.1 Anker punkt i top sektionen
In the top section the anchor point is I top sektionen skal anker punktet monteres
mounted to the top bracket between second på top beslaget midt mellem trin nr. 2 og 3
and third rung (as shown beneath) fra oven (som vist nedenfor)
R
FD
17.2 Anchor points in botttom- and middle 17.2 Anker punkter i bund- og mellem sektioner.
sections.
If the Avanti anchor point is needed, it will Hvis et Avanti anker punkt skal anvendes på
appear on the detail drawings but mounting stigen, vil det fremgå af detail tegningerne.
of this anchor point is to be done at Site. Dette ankerpunkt skal dog først monteres på
Site.
If there is a need for usage of anchor points Er der behov for anvendelse af et anker
at Site the middle anchor point in the flange punkt på site skal det midterste anker punkt i
as described in chapter 17.3 is to be used flangen som beskrevet under punkt 17.3
instead until the Avanti anchor point is anvendes i stedet for, indtil Avanti anker
mounted. punktet er monteret
R
FD
-1
90
4-
Anchor points are locked with Loctite Ankerpunkter fastgøres med loctite 2701
2701 and torqued with 40 Nm. og fastspændes med 40 Nm.
Document number:
PROCESS SPECIFICATION 0023-1269
Title: Approved date Revision Page of
MOUNT TOWER LADDER W. SAFETY WIRE 07 36 38
18.1 Place the Permanent Flexible Safety 18.1 Placer rullen med den permanente
Cable at the bottom of the ladder above sikkerheds wire ved bunden af stigen
the yaw platform. Leaning against the over top platformen. Ligger op mod X-
X- support. supporten til stigen
Secure for wear by adding some protec- Beskyt X-supporten, kanten for kabel
tion between the X- support and the gennemføringen og wire rullen mod
hole for the cable routing slidtage.
Tie up the coil of the Permanent Flexi- Sikre rullen med den permanente
ble Safety Cable with at least 4 of the sikkerhedswire til stigen med minimum 4
largest cable binders (zip ties) store strips (510x12,7mm). Vist med de
R
18.2 Tie up the Carrier Clamp (red circle) at 18.2 Placer Carrier Clamp på bagsiden af
the back of the top bracket. Make sure topbeslaget. Sikre at Carrier Clamp er
the Carrier Clamp is fastened to avoid forsvarligt sikret til transport.
falling off during transportation.
R
FD
-1
90
4-
04
2
Document number:
PROCESS SPECIFICATION 0023-1269
Title: Approved date Revision Page of
MOUNT TOWER LADDER W. SAFETY WIRE 07 38 38
19.1 Replacement of ladder section that has 19.1 Udskiftning af stigesektioner der er
been damaged before and after mount- beskadiget før og efter opmontering i
ing in tower section has to be done be- tårnsektionen skal foretages inden
fore the fall arrest system is mounted. faldsikrings systemet monteres.
Has the ladder been damaged hereafter Beskadiges stigen herefter og dele af
and part of the ladder is replaced, the stigen skal udskiftes, skal hele
whole fall arrest system also is to be re- faldsikrings systemet også udskiftes.
placed.
19.2 Repair ladder with VUI number; only ex- 19.2 Reparations stige med VUI nummer,
ist in a length of 8400 mm. (Item findes kun i en længde på 8400 mm.
766797). The actual length to be re- (Item 766797). Den aktuelle længde der
R
VUI no. is placed on the lowest part of VUI nr. er placeret på nederste del af
the repair ladder, outside on the ladder reparationsstigen, udvendigt på stigens
90
stile. vange.
Is the repair ladder to long the upper Er reparationsstigen for lang skæres det
part of the ladder is cut off the ladder øverste af stigens vanger af, således at
4-
whole new fall arrest system as de- faldsikrings system installeres som
scribed in chapter 9 has to be installed. beskrevet i kapitel 9.
Old ladders and the whole fall arrest Gamle stiger og hele faldsikrings
2