Suspension Systems
and Accessories
15/16" Classic Hook Systems Celotex Brand
®
Suspension Systems
Classic Hook System
Allowable Load
Lbs./Lin.Ft (kg/m) Hanger Spacing
Main Runner Metal ASTM C 635
Item # Length Height Face Thickness 4' (1220mm) 5' (1525mm) 6' (1830mm)
The Classic Hook System features the
C10-12-15 10' 1-1/2" 15/16" .015" Intermediate 6 (8.9) 4 (6.0)
ever-popular 15/16" (24mm) face (3050mm) (38mm) (24mm) (.38mm) Duty
width that is widely used in interior 12.0 (17.9)
designs today. This system incorporates C12-12-15 12' 1-1/2" 15/16" .015" Intermediate 6 (8.9) 4 (6.0)
(3660mm) (38mm) (24mm) (.38mm) Duty
hook-over cross tee end detail 12.0 (17.9)
designed to meet a variety of user
C12-12-20 12' 1-1/2" 15/16" .020" Heavy Duty 8.9 (13.2) 5.6 (8.3)
needs and preferences. (3660mm) (38mm) (24mm) (.51mm) 16.0 (23.8)
Allowable Load
Classic Hook System Lbs./Lin.Ft (kg/m) Hanger Spacing
Cross Tee Metal ASTM C 635
Item # Length Height Face Thickness 2' (610mm) 4' (1220mm)
■ Double web design for lasting
durability and strength. CH2-12-10 2' 1-1/2" 15/16" .010" – *32.5 (48.4) –
(610mm) (38mm) (24mm) (.25mm)
■ Cross tees feature hook-over end CH4-12-10 4' 1-1/2" 15/16" .010" – – 9.1 (13.5)
tab design for positive locking and (1220mm) (38mm) (24mm) (.25mm)
easy disassembly. CH4-12-12 4' 1-1/2" 15/16" .012" – – 10.6 (15.7)
(1220mm) (38mm) (24mm) (.30mm)
■ Intermediate and heavy duty load
CH4-12-20 4' 1-1/2" 15/16" .020" – – 17.3 (25.7)
bearing capabilities. (1220mm) (38mm) (24mm) (.51mm)
■ Bayonet style couplings featured on *Weight limited by a safety factor of 2.
main runners for easy installation.
■ Cross tees offered in standard Protectone Classic Fire-Rated Hook System
®
Suspension Systems
Classic Stab System
Allowable Load
Lbs./Lin.Ft (kg/m) Hanger Spacing
Main Runner Metal ASTM C 635
Item # Length Height Face Thickness 4' (1220mm) 5' (1525mm) 6' (1830mm)
The Classic Stab System features the
C12-12-15 12' 1-1/2" 15/16" .015" Intermediate 6 (8.9) 4.0 (6.0)
ever-popular 15/16"(24mm) face (3660mm) (38mm) (24mm) (.38mm) Duty
width that is widely used in interior 12.0 (17.9)
designs today. Strong staked-on end Allowable Load
tabs are incorporated into the cross Lbs./Lin.Ft (kg/m) Hanger Spacing
ASTM C 635
tee design to provide quick and easy
Cross Tee Metal 1' 2' 4' 5' 8'
installation with optimal tightness Item # Length Height Face Thickness (305mm) (610mm) (1220mm) (1525mm) (2440mm)
among installed components.
CS1-12-15 1' 1-1/2" 15/16" .015" n/a – – – –
(305mm) (38mm) (24mm) (.38mm)
■ Double web design for durability CS4-12-10 4' 1-1/2" 15/16" .010" – – 9.3 (13.8) – –
(1220mm) (38mm) (24mm) (.25mm)
and strength.
CS4-12-12 4' 1-1/2" 15/16" .012" – – 10.6 (16) – –
■ Labor saving stainless steel stab-in (1220mm) (38mm) (24mm) (.30mm)
clip featured on cross tee ends. CS4-12-20 4' 1-1/2" 15/16" .020" – – 17.0 (25.3) – –
(1220mm) (38mm) (24mm) (.51mm)
■ Intermediate and heavy duty load
CS5-12-15 5' 1-1/2" 15/16" .015" – – – 7.0 (10.4) –
bearing capabilities. (1255mm) (38mm) (24mm) (.38mm)
■ Cross tees are offered in standard CS8-12-15 8' 1-1/2" 15/16" .015" – – – – 1.8 (2.7)
(2440mm) (38mm) (24mm) (.38mm)
lengths of 2' (610mm) and 4'
(1220mm). *Weight limited by a safety factor of 2.
Suspension Systems
Elite Narrow Stab System
Allowable Load
Lbs./Lin.Ft (kg/m) Hanger Spacing
Main Runner Metal ASTM C 635
Item # Length Height Face Thickness 4' (1220mm) 5' (1525mm) 6' (1830mm)
The Elite Narrow Stab System
E12-12-18 12' 1-1/2" 9/16" .018" Intermediate 6.4 (9.5) 3.8 (5.7)
features a slim 9/16" (15mm) face (3660mm) (38mm) (15mm) (.46mm) Duty
width to enhance design flexibility 12.0 (17.9)
and to complement finer, contemporary E12-12-20 12' 1-1/2" 9/16" .020" Heavy Duty 8.8 (13.1) 5.3 (7.9)
(3660mm) (38mm) (15mm) (.51mm) 16.0 (23.8)
designs. Cross tees incorporate a
staked-on end tab to ensure quick Allowable Load
installation with optimal tightness. Lbs./Lin.Ft (kg/m) Hanger Spacing
Cross Tee Metal ASTM C 635
Item # Length Height Face Thickness 1' (305mm) 2' (610mm) 4' (1220mm)
Elite Narrow Stab System E2-12-12 2' 1-1/2" 9/16" .012" – *24.5 (36.5) –
(610mm) (38mm) (15mm) (.30mm)
■ Narrow style 9/16" (15mm) face
complements modern designs. E4-12-12 4' 1-1/2" 9/16" .012" – – 9.0 (13.4)
(1220mm) (38mm) (15mm) (.30mm)
■ Stepped-end detail provides a E4-12-18 4' 1-1/2" 9/16" .018" – – 12.9 (19.2)
seamless appearance. (1220mm) (38mm) (15mm) (.46mm)
*Weight limited by a safety factor of 2.
■ Cross tees utilize stab-in design to
maximize strength and flexibility.
■ Intermediate and heavy duty load
bearing capabilities. Protectone Elite Fire-Rated Narrow Stab System
®
Allowable Load
■ Meets building code requirements Lbs./Lin.Ft (kg/m) Hanger Spacing
for seismic applications. Main Runner Metal ASTM C 635
Item # Length Height Face Thickness 1' (305mm) 2' (610mm) 4' (1220mm)
■ Grid features hot-dipped galvanized
PE12-12-18 12' 1-1/2" 9/16" .018" – – Intermediate
steel web construction for corrosion (3660mm) (38mm) (15mm) (.46mm) Duty
resistance. 12.0 (17.9)
®
PE2-12-18 2' 1-1/2" 9/16" .018" – – *45.0 (67.0)
Protectone Elite Fire- (610mm) (38mm) (15mm) (.46mm)
Rated Narrow Stab PE4-12-18 4' 1-1/2" 9/16" .018" – – 12.9 (19.2)
(1220mm) (38mm) (15mm) (.46mm)
System
*Weight limited by a safety factor of 2.
■ Similar features and benefits as Elite
Narrow Stab System.
■ For specific UL fire resistance, time-
rated designs, see page 14.
■ See page 16 for standard and
Colortone options. Selected
Popular Edge
Details Narrow Reveal Edge Narrow Reveal Edge Narrow Reveal Edge
9 "
(Beveled) 9⁄16" Grid (Corner Bevel) 9⁄16" Grid ⁄16 Grid
Suspension Systems
Smoothline Bolt Slot System
Allowable Load
Lbs./Lin.Ft (kg/m) Hanger Spacing
Main Runner Metal ASTM C 635
Item # Length Height Face Thickness 4' (1220mm) 5' (1525mm) 6' (1830mm)
The SmoothLine Bolt Slot System
SL12-13-15 12' 1-5/8" 9/16" .015" Intermediate 5.8 (8.6) 3.5 (5.2)
offers contemporary flair and (3660mm) (41mm) (15mm) (.38mm) Duty
extended design flexibility. 12.0 (17.9)
Complementing many of today’s SL12-13-20 12' 1-5/8" 9/16" .020" Heavy Duty 8.4 (12.5) 4.6 (6.8)
(3660mm) (41mm) (15mm) (.51mm) 16.0 (23.8)
modern designs, this system
provides a uniform ceiling plane
surface when installed with Allowable Load
Lbs./Lin.Ft (kg/m) Hanger Spacing
appropriate reveal edge ceiling Cross Tee Metal
tile products. Item # Length Height Face Thickness ASTM C 635 2' (610mm) 4' (1220mm)
Selected
Popular Edge
Details Narrow Reveal Edge Narrow Reveal Edge
9 "
(Corner Bevel) ⁄16 Grid (Bolt Slot)
9 "
⁄16 Grid (Bolt Slot)
Suspension Systems
Fire-Rated Capped System
Protectone® Aluminum Fire-Rated Capped System
Allowable Load
Lbs./Lin.Ft (kg/m) Hanger Spacing
Main Runner Metal ASTM C 635
® Item # Length Height Face Thickness 4' (1220mm) 5' (1525mm) 6' (1830mm)
Protectone Aluminum
Fire-Rated Capped PAC12-12-15* 12' 1-1/2"
(3660mm) (38mm)
15/16"
(24mm)
.015"
(.38mm)
Intermediate
Duty
6.0 (9.8) 4.0 (6.0)
The Aluminum Capped System meets PAC12-12-20 12' 1-1/2" 15/16" .020" Heavy Duty 8.9 (13.2) 5.6 (8.3)
(3660mm) (38mm) (24mm) (.51mm) 16.0 (23.8)
the needs of kitchens, food preparation
areas, computer rooms, and laboratories.
Allowable Load
Features: Lbs./Lin.Ft (kg/m) Hanger Spacing
Cross Tee Metal
■ Double web design for lasting Item # Length Height Face Thickness ASTM C 635 2' (610mm) 4' (1220mm)
durability and strength.
PAC2-12-15* 2' 1-1/2" 15/16" .015" – **40.5 (60.3) –
■ Bayonet style couplings featured on (610mm) (38mm) (24mm) (.38mm)
main runners for easy installation.
PAC4-12-15* 4' 1-1/2" 15/16" .015" – – 14.0 (20.8)
■ Cross tees are stepped-end, and are (1220mm) (38mm) (24mm) (.38mm)
offered in 2' (610mm) and 4' *Also available with G60 galvanizing. Add suffix “G60” to item number. Example: PAC12-12-15-G60.
(1220mm) lengths. **Weight limited by a safety factor of 2.
■ Cross tees feature staked-on end
tabs for optimal tightness for ease
of installation.
■ Grid features hot-dipped galvanized Environmental Aluminum System
steel web construction for corrosion Allowable Load
resistance. Lbs./Lin.Ft (kg/m) Hanger Spacing
■ Intermediate Duty system available Main Runner Metal ASTM C 635
Item # Length Height Face Thickness 4' (1220mm) 5' (1525mm) 6' (1830mm)
in G60 hot-dipped galvanized for
high-humidity environments. Specify EG12-12-24 12' 1-1/2" 15/16" .024" Light Duty – –
(3660mm) (38mm) (24mm) (.61mm) 5.0 (7.4)
G60 after Item #.
■ For specific UL fire resistance, time-
Allowable Load
rated assemblies, see page 14. Lbs./Lin.Ft (kg/m) Hanger Spacing
■ USDA/FSIS accepted. Cross Tee Metal
Item # Length Height Face Thickness ASTM C 635 2' (610mm) 4' (1220mm)
Environmental Aluminum EG2-12-24 2' 1-1/2" 15/16" .024" – 47.8 (71.1) –
System (610mm) (38mm) (24mm) (.61mm)
The Environmental Aluminum System EG4-12-24 4' 1-1/2" 15/16" .024" – – 7.5 (11.2)
(1220mm) (38mm) (24mm) (.61mm)
is designed to provide exceptional
performance and corrosion resistance
in high moisture environments. Wall Angle
System is offered in the popular Item # Length Height Face
15/16" (24mm) face width. WA12-15SAL 12' 3/4" 15/16"
(3660mm) (19mm) (24mm)
Features:
■ Aluminum, direct hung double web
components.
■ Light Duty ASTM classification
(installation can be modified to
intermediate duty or heavy duty).
Selected
■ Knuckle joint end couplings
Popular Edge
featured on main runners.
Details Trim Edge Reveal Edge Reveal Edge
15 "
(Square) 15⁄16" Grid ⁄16 Grid (Beveled) 15⁄16" Grid
■ Cross tees feature hook-over design
with butt-cut ends.
■ Compatible with NEMA Type-G light
fixtures and standard air diffusers.
■ USDA/FSIS accepted. Reveal Edge
■ Typical applications include high
(Corner Bevel) ⁄16" Grid
15
Suspension Systems
Wall Angle Products A wide spectrum of wall angle products and accessories are available to
complement our grid systems.
■ Variety of wall angle products lends
design and installation flexibility. Wall Angle Products
Standard
■ Standard wall angles to Item # Metal Dimensions Thickness
complement popular interior WA15-15 12' x 15/16" x 15/16" (3660mm x 24mm x 24mm) .020" (.51mm)
designs. WA15-9 12' x 15/16" x 9/16" (3660mm x 24mm x 15mm) .018" (.46mm)
■ WA32-32 12' x 2" x 2" (3660mm x 50mm x 50mm) .024" (.61mm)
Shadow mouldings produce a
reveal-edge look at perimeter Shadow Line
installations. Item # Metal Dimensions Thickness
SM1000 10' x 3/4" x 3/8" x 3/8" x 3/4" (3050mm x 19mm x 10mm x 10mm x 19mm) .020" (.51mm)
■ Aluminum cap and aluminum wall SM1061 10' x 3/4" x 3/4" x 3/4" x 3/4" (3050mm x 19mm x 19mm x 19mm x 19mm) .020" (.51mm)
mouldings available for high SM1064 10' x 3/4" x 1/4" x 1/4" x 3/4" (3050mm x 19mm x 6mm x 6mm x 19mm) .020" (.51mm)
moisture applications. SM1200 12' x 3/4" x 3/8" x 3/8" x 1/2" (3660mm x 19mm x 10mm x 10mm x 12mm) .020" (.51mm)
Aluminum Capped
Item # Metal Dimensions Thickness
WA15-15 WA15-9 WA12-15AL 12' x 3/4" x 15/16" (3660mm x 19mm x 24mm) .020" (.51mm)
WA12-15AL G60* 12' x 3/4" x 15/16" (3660mm x 19mm x 24mm) .020" (.51mm)
*G60 galvanizing
Environmental Aluminum
Item # Metal Dimensions Thickness
WA12-15SAL 12' x 3/4" x 15/16" (3660mm x 19mm x 24mm) .024" (.61mm)
WA32-32 WA12-15AL,
WA12-15SAL, Slip-on Moulding
WA12-15AL G60
Item # Metal Dimensions Thickness
M1034 10' x 1/2" x 3/4" x 7/8" (3050mm x 12mm x 19mm x 22mm) .008" (.20mm)
Grid Accessories
M1034 Hold Down Clips
Item # Description
AHD Adjustable hold down clip
SM1061 3/4"
(19mm)
SM1064 Outside Corner Caps
3/4"
(19mm)
Item # Description
3/4" 1/4" OC15-1 Outside corner cap, 15/16" (24mm) with 1/8" (3mm) radius
(19mm) (19mm)
OC15-9 Outside corner cap for use with wall angle no. WA15-9
3/4" 1/4"
(19mm)
OC15-6 Outside corner cap, 15/16" (24mm) with 3/4" (19mm) radius
3/4" 3/4" (19mm)
(19mm) (19mm) OC15-8 Outside corner cap, 15/16" (24mm) with 1" (25mm) radius
Hold Down Clip Hanger Wire SB20, SB40 Outside Corner Cap Inside Corner Cap Outside Corner Cap
OC15-1, OC15-9 IC15-1, IC15-9 OC15-6, OC15-8
Suspension Systems
Drywall Grid System Our Drywall Grid System offers greater flexibility in designing and installing
gypsum board ceiling surfaces.
■ Offers an efficient alternative to
traditional installation approaches. Drywall Grid System
■ Allowable Load
Installation and leveling can be Lbs./Lin.Ft (kg/m)
performed by a single trade Hanger Spacing
enabling improved production Main Runner Metal ASTM C 635 Time Rated
Item # Length Height Face Thickness 4' (1220mm) Designs
scheduling and quality control.
PDW12-12-20 12' 1-1/2" 1-3/8" .020" Heavy Duty Yes
■ Assortment of furring tee and cross (3660mm) (38mm) (35mm) (.51mm) 16.0 (23.8)
tee options meet a variety of user
Allowable Load
needs and preferences. Lbs./Lin.Ft (kg/m)
Hanger Spacing
■ System designed with versatility, Channel and Metal Time Rated
durability and economical Tee Item # Length Height Face Thickness Description 4' (1220mm) Designs
installations in mind. PDW4-07-20 4' 7/8" 1-3/8" .020" Furring 8.2 (12.2) Yes
(1220mm) (22mm) (35mm) (.51mm) Cross Channel,
■ Main runners feature 1-3/8" (35mm) Steeped End
knurled face for precise screw
PDW4-12-20H 4' 1-1/2" 1-3/8" .020" Furring Tee, 18.6 (27.7) Yes
fastener installation and panel (1220mm) (38mm) (35mm) (.51mm) Hook End
attachment.
PDW4-12-20S 4' 1-1/2" 1-3/8" .020" Furring Tee, 18.6 (27.7) Yes
■ Intermediate and heavy duty load (1220mm) (38mm) (35mm) (.51mm) Stab End
bearing capabilities.
DW4-12-12S 4' 1-1/2" 1-3/8" .012" Furring Tee, 12.3 (18.3)
■ Protectone® Drywall (PDW) items (1220mm) (38mm) (35mm) (.30mm) Stab End
designate products for specific UL PDWL4-12-20S 4' 1-1/2" 15/16" .020" Cross Tee, 17.0 (25.3) Yes
fire resistance, time-rated (1220mm) (38mm) (24mm) (.51mm) Stab End
assemblies, see page 14.
■ System accommodates common Wall Track Metal Time Rated
gypsum board panels of any size up Item # Length Height Face Thickness Description Designs
to 4' x 12' (1220 x 3660mm). WT12E* 12' 1-9/16" 1" – Wall Track – –
(3660mm) (25mm)
■ PDWL4-12-20S cross tee features
white finish and is suitable for use WT12W** 12' 1-1/2" 1" – Wall Track – –
(3660mm) (38mm) (25mm)
with many NEMA Type-G
fluorescent lighting fixtures. UA10 10' 1-1/2" 1-1/2" – Utility Angle – –
(3050mm) (38mm) (38mm)
■ Air handling light fixtures, surface
*Available East of the Rocky Mountains only.
mounted diffusers, or pressurized **Available West of the Rocky Mountains only.
13
Fire Resistance Time-Rated Designs
Ceiling Suspension Systems UL Fire Rated Designs
Type PCH/PCS Type PAC Type PE Type PSL Type PDWH/PDWS
Floor-Ceiling Exposed Exposed Exposed Exposed Furring
Concrete and D203*, D205*, D209 D203*, D205*, D209 D216 - D501, D502**
Steel Floor D215, D216, D218 D215, D216
Units
Concrete and G201, G202, G204 G201, G208*, G209 G217, G229 G264 G523**, G524
Steel Joists G208*, G209, G210 G210, G211, G213 G236, G256 G525**, G526**
G211, G213, G214 G214, G215, G216 G262, G265 G527**, G528**
G215, G216, G217 G217, G218*, G222** G529**
G218*, G222**, G227 G228, G234, G241
G228, G229, G231 G242, G244, G248*
G234, G236, G241 G250, G255*, G256
G242, G243, G244 G258, G259**
G248*, G250, G255*
G256, G258, G259**
Wood Joists L201*, L202, L206 L201*, L202, L206 L201* - L211, L502**
L208, L209, L210 L208, L209, L210 L508**, L513**
L211, L212 L211, L212 L515, L525**
L526**, L529**
P201, P202, P203 P201, P202, P203 P204*, P225 P254 P237**, P239**
P204*, P206, P207 P204*, P206, P207 P227, P251 P253, P241**, P501**
P210, P211, P213 P210, P211, P214 P259* P260*, P506**, P507**
P214, P215, P216 P215, P216, P219 P261* P262* P508**, P509**
P219, P225 P227 P225, P227, P228 P510**, P513**
P228, P229, P230 P229, P230, P231 P514**
P231, P235, P237 P235, P237, P238
P238, P239, P241 P239, P241, P244
P242, P244, P245 P245, P246, P251
P246, P250, P251 P253, P255, P257
P253, P255, P257 P259*, P260*, P261*
P259*, P260*, P261* P262*, P264*
P262*, P264*
Fire rated designs specified in this table refer to UL Classifications based on standard test method ANSI/UL 263 (ASTM E 119, UBC 7-1, NFPA 251, CAN/ULC-S101M) under UL File R15573.
The information contained in this table is intended only to be used as a guide. For detailed time-rated assembly information, refer to the latest Underwriters Laboratories Inc. Fire
Resistance Directory, Vol. 1 at www.ul.com.
Warranties
Ceiling Suspension Systems shall come in contact with the suspension system. equal to that which is determined to be defective. BPB shall not
be responsible for any installation or replacement costs.
5) Prior to installation, the suspension systems must be stored in
10 Year Limited Warranty a dry and clean area, protected from possible damage caused THE FURNISHING OF SUCH CELOTEX® BRAND SUSPENSION
BPB America Inc. warrants for 10 years from the date of by rain, snow, and excessive moisture. The suspension SYSTEMS SHALL CONSTITUTE THE TOTAL LIABILITY OF BPB AND
installation that its Celotex® Brand Ceiling Suspension Systems, systems must also be protected against possible impacts and SHALL CONSTITUTE THE EXCLUSIVE REMEDY OF CUSTOMER.
described below, when installed in accordance with the abrasions while on the construction site. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED,
manufacturer’s recommendations shall not incur 50% red rust 6) The plenum shall not be vented to the outside air in such a INCLUDING ANY WARRANTY OF MERCHANTABILITY OR
as defined by ASTM B 117 test procedures during the 10 years way as to allow humidity above warranty conditions to exist FITNESS FOR A PARTICULAR PURPOSE. LIABILITY IS LIMITED TO
of this limited warranty. This limited warranty is subject to within the plenum. THE ABOVE AND BPB SHALL IN NO EVENT BE LIABLE FOR
further conditions outlined below: LABOR CHARGES, INCLUDING BUT NOT LIMITED TO LABOR
DEVIATIONS FROM THESE TERMS AND CONDITIONS SHALL VOID CHARGES IN CONNECTION WITH REMOVAL OR REPLACEMENT
THE WARRANTY.
Terms and Conditions OF 50% RED RUSTED SUSPENSION SYSTEMS, NOR FOR
INCIDENTAL OR CONSEQUENTIAL DAMAGES.
1) Celotex® Brand Suspension Systems shall be installed in Exclusions
accordance with all applicable BPB recommendations in Damage caused by improper maintenance, fire, exposure to No representative of BPB has authority to make any
effect at the time of installation, using approved installation smoke, fumes, chemical vapors, exterior elements, freezing representation or promise with respect to this limited warranty
procedures described in the Ceiling Systems Handbook temperatures, vibration, abuse, and normal wear and tear are except as stated herein.
published by the Ceiling & Interior Systems Construction not covered by this warranty. The warranty covers the
Association. following Celotex® Brand Ceiling Suspension Systems: Classic
2) The suspension systems shall be installed only in areas free Hook, Protectone® Classic Fire-Rated Hook, Classic Stab,
from excessive humidity and the temperature and humidity Protectone® Classic Fire-Rated Stab, Elite Narrow Stab,
conditions must not exceed 104 degree Fahrenheit (40 Protectone® Elite Narrow Fire-Rated Stab, Protectone®
degrees C) and 90% relative humidity, 95% for Protectone® Aluminum Fire-Rated Capped, Drywall Grid, Smoothline Bolt
Fire-Rated Aluminum Capped System, 100% for Slot, Protectone® Smoothline Bolt Slot, and Environmental Metric Specifications
Environmental Aluminum Systems following installation with Aluminum System. Should the Celotex® Brand Ceiling BPB’s Celotex® Brand Suspension Ceiling Systems are available in
the environmental conditions being controlled within those Suspension System incur 50% red rust during the warranty metric lengths with corresponding metric slotting. To further
limits. Any deviation from those limits in the period, written notice must be given within 30 days after first assist specifiers with metric needs. BPB will provide metric
building or portions of the building shall void the observing this condition to the following address: BPB America conversion dimensioning when this method of measurement is
warranty. Inc., Technical Services Department, 5301 W. Cypress Street, desired. “Soft” or “hard” metric conversion dimensioning is
3) These systems cannot be used in exterior applications, where Suite 300, Tampa, Florida 33607-1766 USA. If upon investigation available, please specify when ordering. To order a product in
standing water is present or where moisture will come in BPB finds that the 50% red rust is caused by manufacturing metric measurement or request metric conversion dimensioning
direct contact with the suspension system. defects and is covered under this warranty, owner’s sole remedy for specification, treat your needs as a “Made to Order Product
and BPB’s liability shall be limited to BPB furnishing new Request”.
4) No water or water vapor from sources including but not
limited to condensation, leaking pipes and/or ducts or steam material of the same or similar type and grade in an amount
Special Notes
Ceiling Suspension Systems The manufacturer should be consulted for recommendations
regarding exterior applications. Installation should be done
All direct hung components are to be properly leveled,
suspended and tightly tied with at least three full turns by not
Standards and Requirements only when the temperature and humidity closely approximate less than 12 gage (2.05mm) galvanized steel wire. Load test
the interior conditions that will exist when the building is recommendations are not to be exceeded, nor should the
Standards occupied. The heating and cooling systems should be operating components be deflected more than 1/360th of their span.
to maintain these conditions prior to, during and after
Celotex® Brand ceiling suspension components are roll formed installation. Special attention should be given to proper ICBO Evaluation Report
to meet or exceed ASTM C 635, and to conform to direct hung ventilation of the plenum, especially in high moisture areas.
structural classifications of Light (5.0-11.9 lbs.). Intermediate See ICBO Evaluation Service, Inc., Evaluation Report No.
(12.0-15.9 lbs.) or Heavy Duty (16.0 or more lbs.) Metal Prior to the start of installation, all exterior widows and ER-1905 for allowable values and/or condition of uses
thicknesses comply with the United States Standard Revised doors are to be in place, glazed and weather-stripped, the concerning material presented in this document. It is subject to
Manufacturers Gage Table, but metal thickness is subject to mill roof is to be watertight and all wet trades work is to be re-examination, revision and possible cancellation.
tolerances. completed and thoroughly dry. Mechanical, electrical or other
utility service work above the ceiling plane are also to be
General Installation Requirements completed. No materials should rest against or wrap around
Celotex® Brand suspended ceiling systems are designed and the ceiling suspension components or the wires that suspend
tested for specifications and use in interior applications only. or brace them.
15
Color Options
All products except Drywall Grid offered in Standard White. Drywall Grid offered with hot-dipped
galvanized finish.
Protectone® Classic Fire-Rated Stab System and Protectone® Elite Fire-Rated Narrow Stab System can be
specified in the following colors:
For special order finishes and customized color options, consult your BPB Sales Represetative for availability, pricing,
and minimum order quantities.
Characteristics, properties or performance of materials or systems manufactured by BPB herein described are derived from data obtained
under controlled test conditions. BPB makes no warranties, express or implied, as to their characteristics, properties or performance under
any variations from such conditions in actual construction. BPB assumes no responsibility for the effects of structural movement.
® ™ Trademarks are the property of BPB plc or its affiliates and related companies
NOTICE: The information in this document is subject to change without notice. BPB assumes no responsibility for any errors that may
inadvertently appear in this document.
©2004 BPB America Inc. Printed in U.S.A. Form LCD-4808 Rev.B/10M/0404