Synronizing Degree
Phase Conversion
Answer Question Subscribe
Series Connection
If 100w & 50w bulb connect in series and if we supply 440v then what happen,
which one glow first?
View Question | Asked by : ummeshraajwade
Answer Question Subscribe
Reactive Power
Answer Question Subscribe
Distribution Tower
Answer Question Subscribe
Electrical Machine Operation
In a 50hz electrical machine what happens when we use more than or less than
50hz?
View Question | Asked by : ummeshraajwade
Answer Question Subscribe
Answer Question Subscribe
Transformer Humming
Answer Question Subscribe
Answer Question Subscribe
Bulb Power
The bulb has a rating of 500W for 220V, if the voltage is 110V, What is the
power of the Bulb?
Latest Answer: Given:p=500WV=220VP=VII=2.27Athan by ohm's lawV=IRso
Answer Question Subscribe
Latest Answer: If voltage is 220V than current rating of bulb = 60/220 = 0.272amp
(from ohm`s law) and resistance of bulb = 220*220/60 = 806.6 ohm. For heater
current = 1000/220 = 4.54 ampand resistance = 220*220/1000 = 48.4 ohmIf both
are connected in series on ...
Read Answers (3) | Asked by : Rahulshelke
Answer Question Subscribe
Answer Question Subscribe
Answer Question Subscribe
DG Set
Answer Question Subscribe
Spark Plug
When the power supply cable got sparked, it gets burnt or caches fire then
explain why the spark plug in our automobiles never get burnt or catch fire
even it spark's?
Latest Answer: Generally in automobiles we have an alternator that produces
ample AC supply that is converted to 12V DC supply via the help of rectifiers
and regulated IC usage. The 12V is then feed to the batterries for recharging.
12V is applied to the ignition ...
Answer Question Subscribe
Line Wire
When we touch the line wire or supply wire we get shock. What is that? Is it
voltage or current or something else?
Latest Answer: It's because of the current flows through your body.When there is a
voltage differential between two point and there is a close loop circuit (your
body act as conductor with high resistant), there will be a current flow.The
emount of current ...
Answer Question Subscribe
DG Set Tripp
Answer Question Subscribe
PF Card Function
Answer Question Subscribe
Answer Question Subscribe
Answer Question Subscribe
Though transformer consist winding which usually cause reactive power change
in both generator and motor but it wont affect reactive power passing through
transformer why?
Answer Question Subscribe
3 Phase Motor
How can we test a 3 phase motor on single phase supply?How can we run a 3
Phase Motor on Single Phase supply for testing?How can we verify of a 3 phase
motors' 6 wire & name them a1/a2/a3..b1/b2/b3
Latest Answer: Use single phase input Inverter is easier. ...
Answer Question Subscribe
What will happen if 400 KVar Capacitor banks are on in manual mode and there
is no load on mains?
Latest Answer: Yes it is sure. Definitly power factor goes towards negative side. ...
Answer Question Subscribe
Corona Effect
that can be observed between two transmission lines or for that matter any
two lines carrying electricity. This occurs generally when the two wires are
very close to each other. This ...
Answer Question Subscribe
Answer Question Subscribe
Voltage Levels
Why all voltage level are multiples of 11, like 220V, 440V, 1100V instead of
200V, 400V, 1000V?
Latest Answer: The value of form factor is 1.1 which is calculated for the sine
wave. At this value of form factor, leakage flux is minimum and efficiency is
maximum for any electrical machines. These machines are operated at sine
waves. ...
Answer Question Subscribe
Answer Question Subscribe
Power Factor
Answer Question Subscribe
If there are three underground cables if a fault takes place in one of them,
How will you detect it?
Latest Answer: Measure the resistance of each cable between farther ends, if there
is a considerable variation in any one of the cable, that is the faulty one. This
method is also used in industries called as "Insulation Resistance Test". ...
Answer Question Subscribe
Quality Factor
Answer Question Subscribe
Answer Question Subscribe
Why we do not use pure capative load instead of pure inductive load?
View Question | Asked by : mallick.subratkumar
Answer Question Subscribe
Phase Advancer
Answer Question Subscribe
EM Waves
Answer Question Subscribe
Main Switch
What the name given for to connect the main switch supply to the various
appliances?
Latest Answer: also MCB ...
What is the difference between neutral circuit and core balance circuit
protection?
View Question | Asked by : appersundaram
Answer Question Subscribe
The cable's actual current rating will usually be lower than the standard (un-
derated) value quoted by manufacturer’s brochures. How to find the
Derating factors for depth of laying,
Latest Answer: There are many factors who can derate the cable rating.1.
Answer Question Subscribe
The earth resistance must and should be less than 0 to 5 ohms. If it is above
the 5 ohms we say earth resistance is not good. ...
Answer Question Subscribe
present there. so there is a dilemma which CB should operate first. Hence the
first zone of protection is never 100% ...
Answer Question Subscribe
Why armature control is used, not the field control for DC motors?What is the
drawbacks in field control method?
Latest Answer: In case of field control method, a rheostat is connected in series
with d field winding. There is a particular limit for the field flux dat is been
controlled by the rheostat. A very high flux may lead to the saturation of the
magnetic circuit and a ...
Answer Question Subscribe
High voltage is traded off for lower current in an AC line transmission. High
current would require thicker cables, hence losses. How much can the voltage
be increased to have a lower power loss? What
Latest Answer: "High current would require thicker cables, hence losses." - I
disagree. The larger the cross-sectional area of a cable, the lesser the
resistance (remember the formula for resistivity). Thicker cables are usually
employed in distribution (from ...
Read Answers (1) | Asked by : jabbaa
Answer Question Subscribe
Power Lines
Answer Question Subscribe
Answer Question Subscribe
Answer Question Subscribe
Potential Transformer
nothing but stepdown transformer. In our metring systems are dsigned only for
110 v or 220 v but we are using 11000, 22000, 33000, ect. For ex PT input is
11000 v but output ...
Answer Question Subscribe
Inductive Loads
Capacitive load.The power drawn in a circuit will depend on type of load, the
power is supplied. The circuit which has inductance in the network is inductive
circuit. Hence ...
Answer Question Subscribe
Nanotech Applications
Answer Question Subscribe
When eletricity is not used what happens to power between source and load?
Latest Answer: The power generated by source quickly responds to the load. If the
load is suddenly disconnected, there will be only line load present so source
cannot quickly change itself as a result heavy transients will be flowing through
the circuit. i.e, the line ...
Answer Question Subscribe
Calculate the size of earthing conductor between earth pit & 2000 KVA
generator.
View Question | Asked by : amanat
Answer Question Subscribe
What is the maximum life of earthing copper rods in earthing ground system?
View Question | Asked by : shafqat
Answer Question Subscribe