ACO Anti-flood Systems

ACO JUNIOR®
Backflow floor drain

The ACO JUNIOR® is a Type 5 The manually operated emergency seal


anti-flooding device for grey water incorporated into the second flap
application and conforms to BS EN 13564. provides the option to shut off the pipe
Compact construction makes this system for additional security or where
backflow gully ideal for new build or long periods of non-use may result in
refurbishment projects. evaporation of the foul air trap allowing
the drain to vent foul odours.
The award winning design incorporates
backflow protection featuring two
gravity closure devices one of which is Key features
an emergency seal which can be 4 Compact design with double flap
operated manually. security
4 147mm to 277mm outlet invert range
4 60mm water seal
Versatile design 4 Manual flap lock prevents venting
The ACO JUNIOR installs into solid
® through trap
floor construction and connects to 4 Tile top rotates and height adjusts
110mm Ø drain pipe. An optional 4 Top access foul air trap
50mm Ø back inlet allows connection and sludge bucket
from an appliance, shower or basin. 4 All parts removable for cleaning
4 Multi-fit 50mm back inlet option
for additional connection
Reliable function
When backflow occurs, reversing the
direction of flow, water reaches the
primary flap and forces it shut. The
secondary flap provides additional
safety.
For more information on ACO Building Drainage visit www.barbourproductsearch.info

ACO Anti-flood Systems

Technical Ordering
ACO JUNIOR® backflow floor drain Reference Ø (mm) Part No
ACO Junior 110 105602
4 Double backflow flaps with manual locking
4 Grating, body and internals injected molded ABS Back inlet option (Multi-fit) 50 105603
and PP plastics Seals maintenance kit - 105607
4 Foul air trap with 60mm water seal
4 Sludge trap
4 Removable grating 197mm x 197mm Load Class K3
to BS EN 1253
Manual lock
4 Connection, 110mm pipe
4 Flow, 1.6l/s
4 Weight, 1.2kg

Bezel rotates for


197mm x 197mm heavy tile alignment Test plug
duty ABS plastic grate

Sludge trap

Foul air trap


130mm
extension Double
piece 147mm to backflow flap
277mm
adjustable
invert

197x197
50Ø optional 110Ø outlet spigot
back inlet
40-170
147-277

180-310
Ø110

165

253

ACO Building Drainage


ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LF
Tel: 01462 816666 Fax: 01462 851490
e-mail: buildingdrainage@aco.co.uk
Website: www.acobuildingdrainage.co.uk
For more information on ACO Building Drainage visit www.barbourproductsearch.info
Uniclass
L7312
CI/SfB
(52.9)

ACO Anti-flood Systems

ACO QUATRIX®
Backflow valve with access chamber

The ACO QUATRIX® backflow valve The motorised flap activates and shuts
is an in-line Type 3 automated under pressure sounding an audible alarm
anti-flooding device conforming to accompanied by a flashing light. When
BS EN 13564 suitable for black water backflow abates the process is reversed.
connections (faecal wastewater) In the event of a power cut, the control
installed with its own access chamber. box has a 24 hour power back-up.

Quatrix backflow devices have a 2-position


Versatile design secondary flap for manual operation.
The ACO QUATRIX®, which installs into 1. Locked open (normal)
solid floor construction with connection 2. Locked shut (for emergency use or
to 110mm and 160mm Ø drain pipe, long periods of non-use)
features a height adjustable access
chamber with optional DPM bonding Key features
flange. Access is gained through a
reversible cover designed for tiled or 4 Tested to BS EN 13564

cementitious floor finishes which rotates 4 Backflow valve with sealed access
chamber height adjustable access
for ease of alignment with floor tiling
shaft rotates for tile alignment
and is fully sealed. The IP67 rated
4 Double flap security with manual
motor/valve body ideal for internal or override
external applications. 4 Reversible access cover for tile infill
or cement floor finishes
Reliable function 4 Fits to 110mm and 160mm Ø pipes

Under normal conditions the backflow 4 All parts removable for cleaning

flaps are open allowing waste water to


4 DPM flange option

flow to the drain. When backflow


4 For internal or external applications

occurs, reversing the direction of flow,


water will reach a certain level within
the pipe activating a pressure sensor
which is monitored at the control box.
For more information on ACO Building Drainage visit www.barbourproductsearch.info

ACO Anti-flood Systems

Technical Ordering
ACO QUATRIX® Reference Ø (mm) Part No

4 Automatic backflow valve for use in black water or ACO Quatrix-K with access
110 620370
chamber and cover
domestic grey water, IP67 rating
4 Power operated flap and manual locking flap ACO Quatrix-K with access
160 620371
chamber and cover
4 IP56 rated control box with visual and audible alarm
4 Lockable access chamber adjusts for height and rotation 100mm chamber extension piece (option) 110/160 620381

4 Reversible access cover 300mm x 300mm Load Class K3 DPM flange (option) 110/160 620382
to BS EN 1253
4 Connection Ø, 110mm and 160mm pipes
Control box (117mm wide x
4 Weight, 17kg
180mm high x 75mm deep)
4 500mA passive Building Management System
output interface
4 Optional DPM flange

Part No DN OD (mm) L mm H mm H1 mm
620370 110 460 297 426 - 512
620371 160 500 272 426 - 512

Ø676
300x360
63-148

Connections to Mains supply


backflow unit (230V, 0.5A)
H

H1

Bezel rotates for


DN

easy tiling Telescopic


12

Reversible cover shaft


with seal
L DPM flange
(optional)

Reversible cover

100mm chamber extension Motor


piece (optional) Manual
lock

Double
backflow flaps
Ribbed casing 110mm &
for casting-in 160mm pipes
ACO Building Drainage
ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LF
Tel: 01462 816666 Fax: 01462 851490
e-mail: buildingdrainage@aco.co.uk
Website: www.acobuildingdrainage.co.uk
For more information on ACO Building Drainage visit www.barbourproductsearch.info
Uniclass
L7312
CI/SfB
(52.9)

ACO Anti-flood Systems

ACO QUATRIX®
Backflow valve

The ACO QUATRIX® backflow valve is an The motorised flap activates and shuts
in-line Type 3 automated anti-flooding under pressure sounding an audible
device conforming to BS EN 13564 alarm accompanied by a flashing light.
suitable for black water connections (faecal When backflow abates the process is
wastewater) installed into site-built access reversed. In the event of a power cut,
chambers or wall mounted applications. the control box has a 24 hour power
back-up.

Versatile design Quatrix backflow devices have a


2-position secondary flap for manual
The ACO QUATRIX® plain backflow valve
operation.
can connect to 110mm and 160mm Ø
drain pipe. This Quatrix model with 1. Locked open (normal)
IP67 rated motor/valve body, has no 2. Locked shut (for emergency use or
fitted access chamber making it ideal for long periods of non-use)
installations with deep invert pipework
requiring operative access within a brick
Key features
built access chamber for internal or
external applications. 4 Tested to BS EN 13564
4 Wall mounted or access chamber
installation
Reliable function
4 Fits to 110mm and 160mm Ø pipes
Under normal conditions the backflow 4 Double flap security with manual
flaps are open allowing waste water to override
flow to the drain. When backflow 4 All parts removable for cleaning
occurs, reversing the direction of flow, and replacement
water will reach a certain level within 4 For internal or external applications
the pipe activating a pressure sensor
which is monitored at the control box.
For more information on ACO Building Drainage visit www.barbourproductsearch.info

ACO Anti-flood Systems

Technical Ordering
ACO QUATRIX® Reference Ø (mm) Part No
ACO Quatrix-K automatic 110 620368
4 Automatic backflow valve for use in black water or
domestic grey water, IP67 rating ACO Quatrix-K automatic 160 620369
4 Power operated flap and manual locking flap
4 IP56 rated control box with visual and audible alarm
4 Mains supply with 24 hour battery back-up
4 Connection Ø, 110mm and 160mm pipes Control box (117mm wide x
4 Wall mounted or self-build chamber 180mm high x 75mm deep)
4 500mA passive Building Management System
output interface
4 Weight: 8kg

Part No DN OD (mm) L mm H mm
620368 110 460 381
620369 160 500 381

400x250

Connections to Mains supply


backflow unit (230V, 0.5A)

Motor
H

Manual lock
DN

Fully sealed
12

cover

Double
backflow
flaps

Ribbed casing
for casting-in 110mm & 160mm
pipes

ACO Building Drainage


ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LF
Tel: 01462 816666 Fax: 01462 851490
e-mail: buildingdrainage@aco.co.uk
Website: www.acobuildingdrainage.co.uk
For more information on ACO Building Drainage visit www.barbourproductsearch.info
Uniclass
L7312
CI/SfB
(52.9)

ACO Anti-flood Systems

ACO TRIPLEX®
Backflow valve with access chamber

The ACO TRIPLEX® access backflow The secondary flap provides additional
valve is an in-line Type 2 passive safety to ensure that backflow is
anti-flooding device conforming to prevented if the first flap should fail to
BS EN 13564 suitable for grey water close properly due to presence of dirt.
connections (non faecal wastewater)
The top lever incorporated into the
installed with its own access chamber.
primary flap provides the option to
manually shut off the pipe during
Versatile design maintenance or for long periods of
non-use.
The ACO TRIPLEX®, which installs into
solid floor construction and connects to
110mm and 160mm Ø drain pipe, Key features
features a height adjustable access
4 Tested to BS EN 13564
chamber with optional DPM bonding
flange. Access is gained through a
4 Backflow valve with sealed access
chamber height adjustable access
reversible cover designed for tiled or shaft rotates for tile alignment
cementitious floor finishes which rotates
4 Double flap security with manual
for ease of alignment with floor tiling override
and is fully sealed. 4 DPM flange option
4 Reversible access cover for tile infill
Reliable function or cement floor finishes
4 All parts removable for cleaning
Under normal conditions the backflow and replacement
flaps simply open by the force of waste 4 Fits to 110 and 160 Ø pipes
water flowing to the sewer. When 4 For internal or external
backflow occurs, reversing the direction applications
of flow, water reaches the primary flap
and forces it shut.
For more information on ACO Building Drainage visit www.barbourproductsearch.info

ACO Anti-flood Systems

Technical Ordering
ACO TRIPLEX® Reference Ø (mm) Part No
ACO Triplex-K-2 with access
4 Passive backflow valve 110 620366
chamber and cover
4 For use in grey water (non-faecal)
ACO Triplex-K-2 with access
4 Double flaps with manual locking
chamber and cover 160 620367
4 Access chamber adjusts for height and rotation
100mm chamber extension piece (option) 110/160 620381
4 Reversible cover 300mm x 300mm Load Class K3
to BS EN 1253 DPM flange (option) 110/160 620382
4 Connection Ø, 110mm and 160mm pipes
4 Weight, 12kg
4 Optional DPM flange & chamber extension

Part No DN OD (mm) L mm H mm H1 mm
620366 110 460 297 393 - 512
620367 160 500 272 393 - 512

Ø676

300x360
30-148

Bezel rotates for


easy tiling Telescopic
Reversible cover shaft
with seal
H

DPM flange
H1

(optional)
DN

12

Manual
lock

Double
Reversible cover backflow flaps
Ribbed casing 110mm &
100mm chamber extension
for casting-in 160mm pipes
piece (optional)

ACO Building Drainage


ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LF
Tel: 01462 816666 Fax: 01462 851490
e-mail: buildingdrainage@aco.co.uk
Website: www.acobuildingdrainage.co.uk
For more information on ACO Building Drainage visit www.barbourproductsearch.info
Uniclass
L7312
CI/SfB
(52.9)

ACO Anti-flood Systems

ACO TRIPLEX®
Backflow valve

The ACO TRIPLEX® backflow valve is an The secondary flap provides additional
in-line Type 2 passive anti-flooding safety to ensure that backflow is
device conforming to BS EN 13564 prevented if the first flap should fail to
suitable for grey water connections close properly due to presence of dirt.
(non faecal wastewater) installed into
The top lever incorporated into the
site built access chambers or wall
primary flap provides the option to
mounted applications.
manually shut off the pipe during
maintenance or for long periods of
Versatile design non-use.

The ACO TRIPLEX® plain backflow can


connect to 110mm and 160mm Ø Key features
drain pipe. This plain Triplex model has
4 Tested to BS EN 13564
no fitted access chamber making it
ideal for installations with deep invert
4 Wall mounted or access chamber
installation
pipework requiring operative access
4 Use with built access chambers
within a brick built access chamber.
4 Fits to 110mm and 160mm Ø pipes
4 Double flap security with manual
Reliable function override

Under normal conditions the backflow


4 All parts removable for cleaning
and replacement
flaps simply open by the force of waste
water flowing to the sewer.

When backflow occurs, reversing the


direction of flow, water reaches the
primary flap and forces it shut.
For more information on ACO Building Drainage visit www.barbourproductsearch.info

ACO Anti-flood Systems

Technical Ordering
ACO TRIPLEX® Reference Ø (mm) Part No
ACO Triplex-K-2 plain 110 620364
4 Passive backflow valve
4 For use in (non faecal) grey water ACO Triplex-K-2 plain 160 620365
4 Double flaps with manual locking
4 Connection Ø, 110mm and 160mm pipes
4 Weight, 3.5kg

Part No DN OD (mm) L mm H mm
620364 110 460 338
620365 160 500 338

400x250

Easy access for Manual


H

maintenance lock
DN

Fully sealed
cover
12

Double
backflow
flaps

Ribbed casing for 110mm & 160mm


casting-in pipes

ACO Building Drainage


ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LF
Tel: 01462 816666 Fax: 01462 851490
e-mail: buildingdrainage@aco.co.uk
Website: www.acobuildingdrainage.co.uk

You might also like