3/2 Solenoid Cartridge Valve, Size 10

Direct Acting, Seat Type


Series WSP32GA ...

S 315 bar, 60 l/min ports 1, 2 and 3 while the valves are


S With closed crossover (overlap) switching. The valves are therefore
S Wet−armature solenoids with high− ideally suited for use with pressure
pressure core tube and slip−on coil accumulators. The straightforward de-
S Coils can be changed without open- sign delivers an outstanding Price/Per-
ing the hydraulic envelope formance ratio. All exposed steel parts
S Surface protection: are zinc−plated, and the valves are suit-
− all external parts A3C to ISO 4042 able for use in the harshest operating
− coil housing is zinc−plated environments. The core tube / slip−on
S BUCHER cavity type DN coil design allows coils to be changed
S Threaded−port body without opening the hydraulic envel-
type GCBA1 (G 1") ope, even when the valve is under pres-
sure. Coils can be turned through 360°
1. Description and secured at any angle. For cus-
Series WSP32GA... directional valves tomers who manufacture their own
are screw−in, 3/2 solenoid−operated manifold blocks, we offer form tool sets
cartridges, nominal size 10. They are for sale or hire. The GCBA1 body with
direct−acting seat valves. Thanks to G 1" port threads is available for pipe−
their closed−crossover (overlap) fea- mounting applications.
ture, there is no connection between

2. Symbols
2 A "normally open" function can be 2
1 = Pressure created by using the appropriate port 3 = Pressure
2 = Actuator 2 = Actuator
3 = Tank connections (see Performance graphs).
1 = Tank
1 3 1 3
WSP32GA10

3. Main characteristics

Designation 3/2 solenoid valve


Design direct acting, seat type
with closed crossover (overlap)
Mounting method screw−in cartridge
Size nominal size 10 mm, BUCHER cavity type DN
Weight kg 1.20
Mounting attitude unrestricted
Flow direction see symbols
Operating pressure range bar to 315 in 1 and 2
to 250 in 3
Flow rate, Qmax l/min 60
Fluids HL and HLP hydraulic oils to DIN 51 524;
for other fluids, please consult BUCHER
Fluid temperature range _C −25 ... +80
Ambient temperature _C −25 ... +50
Viscosity range mm2/s (cSt) 10 ... 500; recommended 15 ... 250
Minimum fluid cleanliness level 18/14 to ISO 4406 / CETOP RP70H; 8 ... 9 to NAS 1638
Solenoid high−pressure, wet−armature solenoid
Nominal voltages VDC 12, 24, 196; for other voltages, please consult BUCHER
Nominal voltage tolerance % ±5
Nominal power consumption W 39
Relative duty cycle % 100

Replaces: W−6.176 1/4 Classification: 430.30.15.25


Reference: 400−P−131152−E−00/01.05
Enclosure protection IP 65
Electrical connection 3−pin square plug to ISO 4400 / DIN 43 650

4. Performance graphs
measured with oil viscosity 33 mm2/s (cSt)

∆p−Q characteristic
WSP32GA10
12 2 1 Switching times
2 3
10
1 2 Solenoid ON 50 ... 300 ms
8 3 2 Solenoid OFF 30 ... 100 ms

6 The switching times are strongly influenced


→ ∆p [bar)

by flow rate, pressure and oil viscosity.


4

5 10 15 20 25 30 35 40 45 50 55 60
→ Q (l/min)

Application limits Application limits


Flow 1 ⇒ 2 (Pressure = 1) Flow 3 ⇒ 2 (Pressure = 3)
350 350
315
→ p max. in 3 and 2 (bar)
→ p max. in 1 and 2 (bar)

300

250 250

200 2 200 2
150 150

100 100
1 3 1 3
50 50

5 10 15 20 25 30 35 40 45 50 55 60 5 10 15 20 25 30 35 40 45 50 55 60
→ Q (l/min) → Q (l/min)

400−P−131152−E−00/01.05 2/4
5. Dimensions
ø 41
Manual
override

PG 9
approx. 123

ø 65
75,5

Model
approx. 201

code

WSP32GA10
36 A/F hex.
for fitting the cartridge,
tightening torque MA = 145 ... 155 Nm
20

M33 X 2
49,5
21

1
78,5

2
18,5

ø 29

Cavity type DN
3
ø 27

6. Schematic section
Seal kit no. DS−336, comprising:
It. Qty. Description Size
4 1 1 O−ring no. 123 ∅ 29.82 x 2.62 N90
2 1 O−ring no. 119 ∅ 23.47 x 2.62 N90
PG 9
3 1 O−ring no. 118 ∅ 21.89 x 2.62 N90
4 2 O−ring ∅ 30.00 x 2.00 N70
5 1 Backup ring ∅ 22.5 x 2.0 x 1.4 FI0751
6 1 Backup ring ∅ 20.7 x 2.0 x 1.4 FI0751

4
1

2 1
5
2
3
6
3
7. Installation and servicing
All work must be carried out with care the specified tightening torque when fit- seals, oil or grease the new seals thor-
and by qualified personnel only. Use ting the cartridge. When changing oughly before fitting them.

400−P−131152−E−00/01.05 3/4
8. Ordering code

W S P 32G A 10 _ − 1 24 VDC _
W = directional valve
S = seat−valve, direct acting
P = closed crossover (overlap)
32G = 3/2 directional function, normally closed
A ... Q = standard model − see relevant data sheets
Z ... R = special features − please consult BUCHER
10 = nominal size 10 mm
(blank) = Nitrile seals
V = Viton seals
Special seals − please consult BUCHER
1 ... 9 = design number (omit when ordering new units)
Voltage and current plainly specified
(blank)
(bla = with ISO 4400 / DIN 43 650 mating plug (standard)
M100 = shipped without mating plug

9. Related data sheets


Old no. New no.
i − 32 400−P−040011−D The Form Tool Hire Programme
i − 45.12 400−P−060190−D BUCHER Cavity Type DN
G − 24.32 400−P−740141−D Threaded−Port Body, Type GCBA1 (G 1")

BUCHER HYDRAULICS www.bucherhydraulics.com


Germany France Netherlands UK USA
Phone +49 7742 85 20 Phone +33 389 64 22 44 Phone +31 79 34 26 24 4 Phone +44 24 76 35 35 61 Phone +1 262 605 82 80
Fax +49 7742 71 16 Fax +33 389 65 28 78 Fax +31 79 34 26 28 8 Fax +44 24 76 35 35 72 Fax +1 262 605 82 78
info.de@bucherhydraulics.com info.fr@bucherhydraulics.com info.nl@bucherhydraulics.com info.uk@bucherhydraulics.com info.wi@bucherhydraulics.com

Switzerland Italy Austria China Product Center (Elevator)


Phone +41 33 67 26 11 1 Phone +39 0522 92 84 11 Phone +43 6216 44 97 Phone +86 10 64 44 32 88 Phone +41 41 757 03 33
Fax +41 33 67 26 10 3 Fax +39 0522 51 32 11 Fax +43 6216 44 97 4 Fax +86 10 64 44 32 35 Fax +41 41 757 16 49
info.ch@bucherhydraulics.com info.it@bucherhydraulics.com info.bj@bucherhydraulics.com info.nh@bucherhydraulics.com

We reserve the right of modification without notice.

400−P−131152−E−00/01.05 4/4

You might also like