LAZY AXE ACCESS 910 PRINT COMMANDS Issue 3

STC
EXRPP:RP=rp; RP data.
EXEMP:RP=RP,EM=ALL; EM data.
EXCLP:EQM=CLC-clc; Control Signalling Link data.
EXCLP:EQM=ALL; Control Signalling Link data.
EXEGP:EMG=ALL; EMG Control signalling link device.
STC-M RPG Connected.
EXRPP:RP=rp; RP data
EXEMP:RP=RP,EM=ALL; EM data
EXCGP:DEV=CLSDEV-X; OR ALL; GS connected CLC Device
EXCPP:EMG=ALL[,RDL]; GS connected CLCs,
EXCPP:EQM=ALL[,RDL]; RDL = Redundancy Level
EXEGP:EMG=ALL; EMG Control signalling link device.
RPG for V5.1 AU(Pots,BA),TAU Both AU & TAU require individual RP
GNACP:AG=ag or ALL; GAM Data Connection.
GNSPP:SNT=STAU-x or STTAU-x; GAM Signalling Channel Path
GNSPP:DIP=xLIAU or xLITAU; GAM Signalling Channel Path
GNSTI:SNT=STAU-x or STTAU-x; Transfer NT to another free RPG.
EXDRP:DEV=STAU-x or STTAU-x; Used to locate connected RPG.
GSD
NTCOP:SNT=snt; Shows DIP and Device connections.
NTSTP:SNT=snt; Shows SNT status.
ETC4 RST devices
EXDRP:DEV=RST-x; Shows ETC connected RP / EM & ro
EXDEP:DEV=RST-x Shows SNT and EMG route.
DTDIP:DIP=xETRST; status.
DTSTP:DIP=xETRST; RST device Connected SNT.
STDEP:DEV=RST-x; DIP status.
AUS (Equivalent to old EMG)
DIREP:EMG=ALL or emg; EMG Event Record.
EXEDP:EMG=emg,EM=em; Shows loaded software.
EXEGP:EMG=ALL or emg; EMG Control signalling link device.
EXEIP:EMG=emg,EM=em; EMRP Information, EMRP type.
EXEPP:EMG=ALL,EM=ALL; EMG EM Processor Control State.
EXHWP:MACCG=emg; or All hardware information.
EXHWP:PIU=AUS-x; As above.
EXMCP; Multiple Access Groups to EMGs
EXSMP:ENB=ALL,ANL; Emergency lines & Announcement li
NNBLI:NODE=AUS-x; Block AUS.
NNBLE:NODE=AUS-x; Deblock AUS.
NNCDP:MACCG=emg; or Shows AUS Master or Slave clock.
NNCDP:NODE=AUS-x; As above.
NNCOP:MACCG=emg; or Shows AUS hardware variant.
NNCOP:NODE=AUS-x; As above.
NNIDP:MACCG=emg; or Shows Node Mesh & AUS status.
NNIDP:NODE=AUS-x; As above.
NNSTP:MACCG=emg; or Shows Node State.
NNSTP:NODE=AUS-x; As above.
NNTEI:NODE=AUS-x; Initiates testing the AUS.
NNUPP:MACCG=emg; or Shows connected Devices/DIPs to P
NNUPP:NODE=AUS-x; As above.
PWESP:MACCG=maccg; Protection switching equipment state
PWSCP:PIU=AUS-x;
Protection switching equipment crite
RECEI:EMG=emg,EMRP=x-A;
Repair EMRP.
RECEI:EMG=emg,STR=A/B;
Repair STR.

Robert Walker, EGS Australia, Phone ECN 880 4606. 08/12/21


Page 1
REMEI:EMG=emg,MAG=EM-x, Maintenance Block EMRP.
PCB=EMRPI;
REPEI:EMG=emg,STR=A/B; Fault Repair STR.
STC REPEI:EMG=emg,MAG=EM-x, Fault Repair EMRP.
PCB=EMRPI;
SYESI:EMG=emg,EM=ALL or em, Restart with or without Reload
EMRPRANK=RELOAD; Use MINRQ or COMPL or RELOAD
TAU(Equivalent = SLCT +more)
BLPFI:PIU=TAU-x Forced TAU blocking.
BLPUI:PIU=TAU-x; Block TAU. Need to block DIP first.
BLPUE:PIU=TAU-x; Deblock TAU.
DTSTP:DIP=Xlitau; DIP status.
EXHWP:PIU=TAU-x; TAU hardware information.
TAU EXPCP:PIU=TAU-x&&-xx; Shows Device and DIP connection.
EXPUP:MACCG=emg; or Shows TAU to AU communication
EXPUP:PIU=TAU-x&&-xx; status.
EXTCP:MACCG=emg; Shows TAU sub rack connection.
EXTGP:MACCG=maccg,SR=sr; Shows TAU connected to sub rack.
EXTGP:PIU=TAU-x; Shows the sub rack TAU located in.
Test FCLPP:PIU=TAU-x,[LOADED]; Shows what software is loaded.
Bus FCPUP; Shows current phase and status.
TEPUI:PIU=TAU-x; Test System access to Debugger.
AU For both POTs & BA.
BLPFI:PIU=AU-x; Forced AU blocking.
BLPUI:PIU=AU-x; Block AU. Need to block DIP first.
BLPUE:PIU=AU-x; Deblock AU.
DTSTP:DIP=xLIAU; DIP status.
EXHWP:PIU=AU-x; AU hardware information.
EXPCP:PIU=AU-x&&-xx; Shows Device and DIP connection.
EXPUP:MACCG=emg; or Shows TAU to AU communication
EXPUP:PIU=AU-x&&-xx; status.
AU FCLPP:PIU=AU-x,[LOADED]; Shows what software is loaded.
SLOCI:PIU=AU-x; Subscriber line circuit test.
SLOCI:SNB=snb; As above.
SLOCI:DEV=dev; As above.
TEPUI:PIU=AU-x; Test System access to Debugger.
PRINT VAR CTRLAU 0-:57; Var SYSTMANSTATE contains V5.1
Interface state.
H’F = Null means not started
H’0 = Starting Up.
H’4 = Working. See Plex for other sta
AUS PIU AUS LED FUNCTION

MIA Red Manual Intervention Allowed OAM

PWR Green Power OK. On = Stable power source.

On = Active control signalling li


COM Green Communication protocol OK.
protocol towards APZ.

SYN Yellow Clock Synchronisation On = Proper synchronisation


Flash = 1 synch ring missing

CSR Yellow Call Set up Rate Flash One flash = A call is set up i
the time switch.

TL1 Yellow Traffic Level 1 indication TL1 off + TL2 off = no traffic

Robert Walker, EGS Australia, Phone ECN 880 4606. 08/12/21


Page 2
TL1 on + TL2 off = 0<X<100

TL2 Yellow Traffic Level 2 indication TL1 off + TL2 on = 100<X<2


TL1 on + TL2 on = 200< cal

Robert Walker, EGS Australia, Phone ECN 880 4606. 08/12/21


Page 3