You are on page 1of 1

PINK GEL CATALYST

MATERIAL SAFETY DATA SHEET


IDENTIFICATION HEALTH HAZARD DATA
Manufactured for: MYDENT INTERNATIONAL EFFECTS OF OVEREXPOSURE: None
Address: 80 Suffolk Court Routes of Entry=
City, State, Zip: Hauppauge, NY 11788 Skin: Possible skin irritant Eyes: Eye contact may cause irritation
Telephone: 631-434-7760 Ingestion: N/A Inhalation: None
Date Prepared: 1/1/2011
SIGNS AND SYMPTOMS OF EXPOSURE
Chemical Name: Pink Gel Catalyst Skin: Irritation Eye: Irritation
HAZARDOUS INGREDIENTS Ingestion: N/A Inhalation: None
ITEM OSHA PEL ACGIH TLV OTHER LIMITS %
RECOMMENDED Medical Conditions Generally Aggravated by Exposure: N/A
Hazardous/Toxic Components (CAS #): EMERGENCY AND FIRST AID PROCEDURES
Silicic acid esters and Dibutyltin dilaurate Skin: Wash with plenty of water and soap
Eyes: Flush immediately with plenty of water. If irritation
persists, see eye doctor..
Hazard Rating (NFPA): Irritant Ingestion: Consult a physician
HEALTH: 1 FLAMMABILITY: 1 REACTIVITY: 0 SPECIFIC: Stable Inhalation: : If affected, remove to fresh air.
PRECAUTIONS FOR SAFE HANDLING AND USE
AS PER OSHA HAZARD COMMUNICATIONS STANDARD 29CFR 1910.1200 Steps to be taken in case material is released or spilled:
PHYSICAL DATA/CHEMICAL CHARACTERISTICS Contain and absorb spilled material using an appropriate spill
Appearance and Odor: absorbent. Collect in suitable container for disposal.
Pink – Gelatin-like material with slight sweet odor
Boiling Point: N/A Waste Disposal Method: Dispose of material in
Volatile (by weight %): 30% accordance with local, state, and federal requirements.
Vapor Pressure (mm Hg.): < 5 mmHg @ 25°C
Precautions to be Taken in Handling and Storing: Air sensitive
Melting Point: N/A
material; Store in supplied packaging. Keep container tightly
Vapor Density (AIR – 1): N/A
Evaporation Rate (Butyl N/A closed when not in use. Store away from heat sources. The use of
Acetate – 1): synthetic vinyl gloves while handling is recommended.
Solubility in Water (H 2O):: Insoluble in water Other Precautions: Wipe up any affected area with absorbent material.
Specific Gravity (H2O – 1): > 1
pH: N/A CONTROL MEASURES
FIRE AND EXPLOSION HAZARD DATA Respiratory Protection (Specify Type): None
Flash Point (Method Used): 300°F
VENTILATION: NONE
Flammable Limits: N/A
Extinguishing Media: : Water spray, Foam, Powder Carbon Dioxide Local Exhaust: N/A
UEL: N/A LEL: N/A
Special Fire Fighting Procedures: : Appropriate protective equipment Mechanical (General): N/A
must be worn in case of fire
Unusual Fire & Explosion Hazards or Procedures: Material can burn Protective Gloves: Impervious or synthetic vinyl gloves are recommended.
generating irritating gases
Eye Protection: Recommended
REACTIVITY DATA
Stability: Stable Other Protective Clothing or Equipment:

Conditions to Avoid: None N/A Other Work / Hygiene Practices: N/A

Incompatibility (Material to Avoid): No dangerous reactions known. CARCINOGENICITY


Incompatibility with strong oxidizing agents.
NTP: N/A
Hazardous Decomposition of Byproducts: Silicic acid esters may
IARC Monographs: N/A
hydrozlyze to form 2-methoxyethanol which can pose additional health
hazards. OSHA Regulated: N/A
SPECIAL INFORMATION
Hazardous Polymerization: N/A
24 hr EMERGENCY PHONE #: CHEMTREC (800) 424-9300
Note: Carl Parker Associates / Mydent Corporation has compiled this data based on
TRANSPORTATION: (DOT info if Applicable) the research and input of qualified experts in the field of microbiology, chemistry and
N/A quality assurance. The data are not to be taken as a warranty or representation for
which Carl Parker Associates / Mydent Corporation Int’l assumes legal responsibility.
They are offered only for your consideration and verification.