You are on page 1of 2

CHANGING OF INVERTER TYPE

ABB Oy IN SPARE PART RMIO BOARD


3AFE00470793
Drives 00470793.DOC

Dept. Date Made by Checked / Accepted by Revision Page


EJC 22.10.2007 Anu Lindholm Osmo Pasuri C 1/2

Changing of inverter type in spare part RMIO board


• standard software version ASXR7310 / AS7R7292 and later
versions

1. Background

The loading package of Standard Application is divided to two different HW related packages:

AS7R7xxx and ASXR73xx

The ASXR73xx package supports only types R2-R8 in products of ACS800-01, -02, -04, -07.

The AS7R7xxx package supports only types R2i-R8i, nxR8i in products of ACS800-07, -11, -17, -31, -37, -
104, -107 and ACS800LC

Detailed list of software compatibility and the latest software versions in production can be found from
following tables:

ACS 800 Software Compatibility :


http://search.abb.com/library/ABBLibrary.asp?DocumentID=3AFE64638211&LanguageCode=en&Docume
ntPartId=1&Action=Launch

ACS 800 Program Versions in Production :


http://search.abb.com/library/ABBLibrary.asp?DocumentID=3AFE64810651&LanguageCode=en&Docume
ntPartId=1&Action=Launch

2. Supported spare part inverter types

All inverter types for spare part RMIO board are in 17 parameters. Each parameter contains one
logical group of inverters. E.g. parameter 112.20 INV RECNF STD 200 includes 200 V standard
drive series inverter types (SRxxxx_y).

ASXR7xxx-type series: AS7R7xxx-type series:


112.20 INV RECNF STD 200 112.21 INV RECNF STD 400 (exl. single types)
112.21 INV RECNF STD 400 (exl. parallel types) 112.22 INV RECNF STD 500 (exl. single types)
112.22 INV RECNF STD 500 (exl. parallel types) 112.23 INV RECNF STD 690 (exl. single types)
112.23 INV RECNF STD 690 (exl. parallel types) 112.24 INV RECNF MD 400
112.25 INV RECNF MD 500
112.26 INV RECNF MD 690
112.27 INV RECNF 811 200
112.28 INV RECNF 811 400
112.29 INV RECNF 811 500
-------------------------------------------------------------- 112.30 INV RECNF 811 690
STD stands for standard series 112.31 INV RECNF 817 400
MD stands for multidrive hardware 112.32 INV RECNF 817 500
811 meaning ACS800-11 hardware 112.33 INV RECNF 817 690
817 meaning ACS800-17 hardware 112.34 INV RECNF LC 400
LC means water cooled hardware. 112.35 INV RECNF LC 500
112.36 INV RECNF LC 690

___________________________________________________________________________
CHANGING OF INVERTER TYPE
ABB Oy IN SPARE PART RMIO BOARD
3AFE00470793
Drives 00470793.DOC

Dept. Date Made by Checked / Accepted by Revision Page


EJC 22.10.2007 Anu Lindholm Osmo Pasuri C 2/2

From AS7R7322 inverter types are divided in two groups.


Both are available in the same DOS loading package, but require separate DriveWindow backup
packages (XRNONE and LXNONE).

When software is downloaded with DOS, only the inverter types in the same inverter group are
downloaded and available in reconfiguration. The inverter group division is as follows:

• ACS800 Multi Drive, Air Cooled XRNONE


400V Single Drive, parallel 2...4xR8 SR0610_3 … SR1850_3
500V Single Drive, parallel 2...4xR8 SR0760_5 … SR2310_5
690V Single Drive, parallel 2...6xR8 SR0750_7 … SR3490_7
400V MultiDrive R2-R5, R6i...R8i, 2...6xR8i NR0003_3 …NR3080_3
500V MultiDrive R2-R5, R6i...R8i, 2...6xR8i NR0004_5… NR3640_5
690V MultiDrive R4-R5, R6i-R8i, 2...12xR8i NR0011_7 … NR6970_7
230…690V ACS800-11/31 R5 – R6 MR0011_2 … MR0100_7
400-690V ACS800-17/37, R7i, R8i+R8i, MR0140_3 … MR3310_7
2...6xR8i + 2...6xR8i

• ACS800 Multi Drive, Liquid Cooled LXNONE


400-690V Liquid Cooled R8i, 2...10xR8i LS0390_3 … LS6620_7
400-690V Liquid Cooled R7i – R8i, 2...10xR8i LC0120_3 … LC6620_7

• ACS600 Drives (as before) XFNONE


All ACS600 inverter types
SFxxxx_y-, NFxxxx_y- and MFxxxx_y-inverter types

3. Other changes

• Parameter 112.06 INVERTER RECONFIG, where all the inverter types were previously, has been
removed.

• Inverter type selection texts can now be seen also on different DriveTools windows. Previously only
selected number which was describing inverter type was displayed.

• In new version XXNONE type values are downloaded automatically before the requested type.
Previously XXNONE type had to be first and after that a required inverter type. If XXNONE loading
was not done before loading new type, all inverter configuration parameters were not changed to new
values.

• In new version 102.1 PARAM LOCK is not needed to open if reconfigure parameter is changed using
a DriveTool.

4. Inverter type changing procedure for RMIO boards having XXNONE, XRNONE or LXNONE type
downloaded

a. Set 16.03 PASS CODE to 564. This opens parameter groups 112 and 190.
b. Select inverter type from parameters 112.20- 112.36
c. Make a power down for RMIO card.

___________________________________________________________________________