WHY TREAT COMPRESSED AIR
A compressor takes in atmospheric air that is loaded with moisture, dirt, dust
fibers and bacteria. Due to constant use, wear & tear, most compressors deliver
large amounts of oil fumes along with compressed air. The hot air delivered by a
compressor carries contaminants which cause corrosion, excessive wear,
malfunction and ultimately failure of your compressed air components, tools and
system. To assure a reliable and efficient operation of a plant, these
contaminants must be removed.
190M particles/m3
AIR
COMPRESSOR RUST TO COMPRESSED
AIR SYSTEM
Confidential
Fundamentals
on purification of compressed air
The air loaded with moisture,particles and oil is
purified by means of filtration and drying.
filteredare:
Solid particles &
coalescing components
dried are :
all vapour phase components
Confidential
Fundamentals
on water separation and drying
Water vapour content g/m ³
58.3
filtration
17.5
4.50 condensation
0.76 adsorption
0.10
-40 -20 0 20 40
Dew point °C
Confidential
Fundamentals
structure of the desiccant
n Adsorbents
with fine pores
inner surface area
up to 1000 m² /g
n Adsorbents types
- Molecular sieve
- silica gel
- activated alumina
Confidential
Fundamentals
Regeneration - Heatless
Loading time after each load situation
tB = 3 - 5 min. Adsorption of moisture
on external desiccant surface.
Confidential
Fundamentals
Regeneration - Heated
Loading time after each load set-up
tB = 4 - 8 h. Adsorption of moisture on
external surfaces and internal pores
of desiccant beads.
Confidential
Fundamentals
Adsorption - Desorption
n Adsorption drying
requires two vessels,
filled with an adsorbent
Desorption
(drying agent)
Adsorption
n Adsorption and
desorption take place
simultaneously at
the same time
Confidential
Vacuum Heat Regeneration
(Zero Purge) Desiccant Air Dryer
Confidential
Energy Costs on the Rise Again
11July08 @ US$147
Current
US$72
Confidential
Electricity Tariff on the Rise Again
Confidential
Vacuum Heat Regen (Zero Purge) Dryer
Can Help Companies to Save Energy!
Confidential
Characteristics of Xebec Vacuum Heat Regen Dryer
Confidential
Heat Regen Cycle (Right Chamber)
CDA out
Wet
Air in
Confidential
Cooling Cycle (Right Chamber)
Confidential
Re-Pressurization (Right Chamber)
Confidential
Heat Regen Cycle (Left Chamber)
Confidential
Cooling Cycle (Left Chamber)
Confidential
Re-Pressurization (Left Chamber)
Confidential
Adsorption / Desorption Information
200
After the heating
Desorption
and before switch over
150
Range (160 to 200°C)
from
Temperature °C
desorption to
adsorption,the desiccant
100
bed must
be cooled to Transition
approx. 60°C, range (70 to 80°C)
to avoid a heat and
50
pressure dewpoint spike.
Adsorption
0 Range (20 to 60°C)
Confidential
Major Component – Switching Valves
Confidential
Switching Valves High performance butterfly valve
For 2” and larger valves requirement
Inlet and Regen Exhaust Valves
Features
SS Disc
Carbon Steel Body
Confidential
Major Component – External Heater
Confidential
External Electric Heater
Flanged immersion heater
Low watt density type (for long life span)
Incoloy* sheath element
Insulated heater housing
Temp dependent Regeneration cycles
Adequate regeneration is confirmed by
actual regen air outlet temperature, not
simply by a timer
Confidential
Vacuum Pump
Quiet operation
Totally enclosed fan cooled
housing
Sized for required regen vacuum
pressure and maximum required
regen flow rate
Brands of Vacuum Pump may
varies
Confidential
User Interface/Text Display
OPERATOR INTERFACE
SHIFT=> In order to choose one of the next four options, the SHIFT
button must be pressed first. An “s” in the lower right corner
indicates the upper row is now active.
Confidential
Maintenance of Vacuum Heat
Regeneration Adsorption Dryer
Confidential
Daily Maintenance
Visual Check
• Unusual noises
• Check for any alarm
• Check dewpoint
• Check inlet pressure & temperature
• Check that filter condensate drain is working
• Check drain pipe for blockage
Confidential
Weekly Maintenance
Visual Check
• Check Filter’s differential pressure indicator. If in
region of 8~10 psi indicates that element is dirty &
should be replaced
•Inspect inlet suction filter & clean or replace if
clogged, dirty or damaged
Confidential
Monthly Maintenance
• Check silencers/mufflers on dryer and
replace if clogged or dirty
• Check dryer operation cycle for proper
operation of butterfly valves & solenoid
valves.
• Check if heater outlet temp is between 350
degF & 450 degF (Press Shift F7)
Confidential
Annual Maintenance
• Replace the suction inlet filter
• Replace elements of Pre, After-filters &
Final air filter at least once a year
• Disassemble, clean & inspect all check