You are on page 1of 2

 

Patient Instrucctions fo
or LifeWaatch® AC
CT LifeSttar™ 
Before you
u leave the offfice today you
u will be issued an ACT LifeSStar monitor. If there are no
one immediately 
available, our staff will m ur to pick‐up tthe next availaable monitor. When you recceive 
make arrangeements for you
the monitor, you will fin
nd detailed insstructions insiide. We have ssimplified the instructions ffor you on thiss 
sheet. If yo questions afterr reading the manual, call the LifeWatch field represen
ou still have q ntative at 1‐86
66‐
816‐0462..  

Wheen to calll:
LifeWattch® Clientt Care Centter (24/7) 1‐800‐517‐6
6330
• Too activate mo
onitoring servvice 
• If you experien
nce a rash 
• If your monitor does not function 
• If you are runn
ning out of supplies 
LifeWattch® Clientt Executivee  1‐866‐811‐4
4147
William SSotka  (Cell# 224‐244‐03
347) 
• If you have anyy questions reegarding the steps listed in
n the instructtion manual  
• If you are unsaatisfied with tthe Client Carre Center 
Heart of the Valley Pediatricc Cardiologgy 925‐416‐0
0100
• If you experien
nce an episod
de that requirres Dr. Maxweell’s attention

Pleease call 91
11 in an em
mergency
 

S
SET UP: 
1) A
Attach sensor cables to the electrodee stickers. (p
pictured on rright) 
2) Clean your skkin with rubb
bing alcohol where the eelectrodes wwill be placed
d. 
3) Place electroddes on your chest as sho
own by the d diagram belo ow. 
 
 
 
 
 
 

 
4) A
Activate the LLifeWatch® sservice by caalling 1‐800‐‐517‐6330. D DO NOT use the LifeStar ACT 
ceell phone to make this ccall.  
5) When instruc
W cted by a LifeeWatch® tecchnician, preess and hold the POWER R button on tthe 
ceell phone for 5 seconds until screen lights up. (p pictured belo ow on right) 
6) Iff the ACT Mo onitor does n not automattically begin,, press the ““End Call” bu
utton, select 
“SStart,” and tthen choose the “ACT M Monitor” proggram (top leeft of the screen). 
7) Fo ollow the insstructions on the cell ph
hone screen as service iss being activated. 

  Replacing tthe battery  Notificatio
on of unsecure o
or  Charger cable connnects to the  The power buttton is located 
disconneccted electrodes bottom of the cell phone  on the top left of the cell 
phone 
N
NOTE: 
• Do not use th
D he cell phonee to make ou utgoing callss other than an emergen ncy call to 91
11. 
O
Outgoing call s will be billed directly tto the patien
nt by LifeWatch®. 
• W
When monito oring, alwayss remain witthin 10 feet of your cell phone.  
• Replace electtrode stickerrs every day or when thee adhesive iss not firmly aattached to skin. 
• Replace the b
batteries of tthe sensor eevery 2‐3 dayys. Only use the batteriees that are 
provided by LLifeWatch® ((pictured on above) 
• Recharge youur cell phonee every nightt. Once again n, make suree your sensoor remains closer 
th
han 10 feet ffrom your reecharging ceell phone at n night. 
• Check your phone every 5 hours by p pressing any button to verify the beaating heart.  
• The screen sh
hown above (center) will appear on the cell pho one if a lead wire has 
become disco onnected. To o resolve maake sure all eelectrodes and lead wirees are secureely 
atttached. 
RETURN
NING THE MONITO
OR: 
• In
nsert the sen
nsor and celll phone into o the plastic bubble‐wrap
p bag, and p
place the bagg in 
th
he box. 
• Place the boxx, with its contents, in th
he return envvelope provided by LifeW
Watch®. Thee 
postage has bbeen prepaid d.  