VIET MY TRADING SERVICES CONSTRUCTION CO.

, LTD

Chim Sao WHP visit report


Overview

Chim Sao Offshore Platform Project


Operator: Premier Oil UK
Water Depth: 115 m / 380 ft
Climate: Tropical
Region: South East Asia
Country: Vietnam

Discovered in 2006, Chim Sao, formerly Blackbird, is located on Block 12W and 12E in 377 feet (115
meters) of water, around 248 miles (400 kilometers) southeast of Ho Chi Minh City, offshore Vietnam.
The Chim Sao wellhead platform (WHP) jacket has been loaded out and in place in July 2010 and to
commence production on July 1, 2011.

Viet My (Swagelok Vietnam) was supplying Fittings (SS316), Tubing (SS316/316L) and Valves (SS316)
for this project.

Background Information - Corrosion Issue

We were told after Chim Sao wellhead platform was put in place 4 -5 months later external corrosion
stain occurs on Instrument tray, Bracket, Bolts and Nuts, Fitting, Tubing and Valves, sizes ¼” , 3/8”, ½”
and 1” in instrumentation system:

We were contacted to help provide feedback on the corrosion and suggestion to address this issue.

Our team consists of Mr. Prapas Lamphuoc- Sales Account Manager, Mr. Nguyen Duc Thien-Sales
Engineer visited the platform on February, 15th 2011.

Upon arrival at the Offshore Platform we were met by Mr. Gerry and was brief about what we can do and
what he need from us regarding visual inspection. He assigned Mr. Dat -Mechanical Engineer, PTSC
M&C and Mr. Viet - Technical Engineer, PV Trans (Premier Oil’s sub-contractor) to go with us around the
platform.

1
VIET MY TRADING SERVICES CONSTRUCTION CO., LTD

We spent a total of half a day onboard Chim Sao WHP and we inspected the following areas:

1. Chemical Injection line


2. Water injection line
3. Hydraulic line

Customer comment and request

The comment and question customer asked us is:

1. All tubing system are SS316.

2. Fittings and tubing are SS316, why did green color stain appear on surface. They understand
green color stain only appear on copper material.

3. Is there some solution that we can recommend to them to prevent reoccurrence, or at least inhibit
reoccurrence to some degree?

Investigation Methods

Visual inspection of the corrosion component at Chim Sao wellhead platform. Photos were taken on for
component before and after wiping with clean cloth. Our focuses are on Tubing, Tube Fitting and Valves

Observation

• The system is currently not in operation.


• The systems were located in an open area and exposed to high humidity (Water droplets and salt
stain appear at all surface of components)
• What we see:
o “Brown color stain” or “Green color stain” on all uncoated component surfaces.
o When we wipe some of the stain came off but the external surface still revealed some
corrosion attack.
o The surrounding parts which were painted or coated (Grease), were found to be without
stain.
o Temperature in the surrounding area is normal but with strong wind.
o Water droplets and salt stain appear on uncoated component surface.

Summary

Visual Inspection reveal 2 kind of stains existing on component surfaces:

1. Brown color stain were found on fittings, tubing and valves surface which are located at
the Chemical Injection line and Hydraulic line. To determine whether the stains are actual
corrosion wipe the stains. Some component surface stain disappear, but some stain remain
(reduce).

2
VIET MY TRADING SERVICES CONSTRUCTION CO., LTD

Location - Chemical Injection Line (first level above sea water)

Picture 1. Chemical injection Line – SS316 material. Before wipe

Picture 2. Chemical injection Line – SS316 material. After wipe

3
VIET MY TRADING SERVICES CONSTRUCTION CO., LTD

Picture 3. Chemical injection Line – SS316 material fitting and fitting ½” & 1” Before wipe

Picture 4. Chemical injection Line – SS316 material fitting and fitting ½” & 1” After wipe

4
VIET MY TRADING SERVICES CONSTRUCTION CO., LTD

Picture 5. Before wipe, water droplet on tubing ½” OD surface

Picture 6. Chemical injection Line – SS316 material tubing ½ ” OD After wipe

5
VIET MY TRADING SERVICES CONSTRUCTION CO., LTD

Picture 7. Chemical injection Line – SS316 material tubing ½ ” OD Before wipe

Picture 8. Chemical injection Line – SS316 material tubing ½ ” OD After wipe

6
VIET MY TRADING SERVICES CONSTRUCTION CO., LTD

Location – Hydraulic Line (second level above sea water)

Picture 9. Hydraulic Line

Picture 10. Hydraulic Line

Hydraulic lines are located at high levels which are difficult access without ladder or scaffolding. As
such we were not able to clean the component and show the differences.

7
VIET MY TRADING SERVICES CONSTRUCTION CO., LTD

2. Green color stain were found on fittings and tubing surfaces of the Water Injection line only.
We wipe the stain with clean cloth. We found the stain to be more difficult to remove.
However those stain that was remove show dark gray surface.

Location- Water Injection Line (first and second level above sea wa

Picture 11. Water Injection system, Green Color stain on Tubing and Fitting

Picture 12. Water Injection system, Green Color stain on Tubing and Fitting

8
VIET MY TRADING SERVICES CONSTRUCTION CO., LTD

Picture 13. Green Color Stain on tubing (Material?) and fitting (Monel) 3/8” OD

Picture 14. Water Injection line tubing (Material?) ½” OD Before wipe

Picture 15. Water Injection line tubing (Material?) ½” OD After wipe

9
VIET MY TRADING SERVICES CONSTRUCTION CO., LTD

Picture 16. Water Injection line tubing (material?) and fitting (Monel) ½” OD Before wipe

Picture 17. Water Injection line tubing (material?) and fitting (Monel) ½” OD After wipe

10
VIET MY TRADING SERVICES CONSTRUCTION CO., LTD

Picture 18. Green Color Stain on tubing (Material?) and fitting (Monel) ½” OD Before wipe

Picture 19. Green Color Stain tubing (Material?) and fitting (Monel) ½” OD Before wipe

11
VIET MY TRADING SERVICES CONSTRUCTION CO., LTD

Picture 20. Green Color Stain on tubing (Material?) fitting (Monel) ½” OD After wipe

Our comment and Suggestion:

1. We confirm that both Chemical Injection line and Hydraulic Line are of SS316/SS316L (Sandvik
print on the tubing surface and Swagelok marking on Tube Fittings). However, the Water Injection
line tubing cannot be confirmed as we cannot see any printing on the tubing surface. We suspect
the fittings are Monel material, an alloy of nickel and copper. You can tell from the marking of the
parts, for example, the nuts marked Swagelok-MSNA are nuts made from Monel and have heat
code SNA. It is typical for Monel to develop a greenish scale.

Monel does not necessarily have the best resistance to pitting and crevice corrosion resistance.

Since we are not sure what materials were used for the tubing, we suggest you check your record
to identify the material used. Cleaning is recommended, please see suggestion below.

Alternatively, you may want to look at Alloys 6Mo and 2507 which are better corrosion resistant to
seawater environment.

2. The "Brown Color rusted" on Chemical Injection line and Hydraulic line (SS316 parts) were most
likely contaminated with iron that may have come from different sources, for example, cutting,
grinding, and blasting of structural parts of the platform. As soon as "free iron" accumulates on a
stainless steel surface, it will oxidizes to form a brownish deposit, giving the stainless steel a
rusted appearance.

From our visit we suggest the following step:


• Clean – To identify extend of the corrosion and prevent the spread of corrosion.
• Protect - Prevent the spread of corrosion.
• Change to compatible material.

12
VIET MY TRADING SERVICES CONSTRUCTION CO., LTD

Cleaning

It is very important that stainless steel be kept clean. Regular cleansing with water is important,
and if the cleansing is done with seawater than a fresh water rinse is recommended. The
customer should consider cleaning the tubing and fittings. There are many cleaning products in
the market . Please refer to British Stainless Steel Association recommendation for Stainless
Steel as below:

Mild staining or surface 'bloom' Mild-non scratching domestic cleaning creams or


polishes can be used.
These usually contain calcium carbonate, with
surfactant additions. 'Jif' kitchen cream cleaner
(Lever Brothers Ltd) is an example of such a
product.
Domestic stainless steel cleaners, which may
contain citric acid can also be used. Shiny Sinks -
(Home Products Ltd) is an example of such a
product.

Moderate rust staining Phosphoric acid cleaners can be effective if


sufficient time and care is taken, with minimal risk
of etching the surface.
Alternatively, dilute nitric acid should remove small
amounts of embedded iron and will help
repassivate the cleaned surface.

More severe rust staining Nitric / hydrofluoric acid pickling preparations


should remove more embedded iron than nitric acid
alone.
Surface etching is likely and so complete
restoration to the original finish and surface texture
may not be possible.
If these preparations are left on stainless steel
surface too long, pitting can be caused. There is a
limit to what can be achieved.
Although contamination may be removed, these
treatments will not remove any pitting associated
with severe staining.
In such cases mechanical grinding may have to be
considered to 'bottom-out' the pits which means
that a complete restoration of the surface will then
be needed.

13
VIET MY TRADING SERVICES CONSTRUCTION CO., LTD

Protect

Picture 21. Cover with Plastic to protect from sea water

Picture 22. Cover with Grease on Valve handle

This report is written by Prapas Lamphuoc, Nguyen Duc Thien, Andrew BT Wong