You are on page 1of 8

 

ISO 13485:2003

ISO 9001:2008
No. 8090055

No. 225850/1
 

Ultima SE Ultrasound Scanner

Clinical application:

abdominal cavity organs;


obstetrics and gynecology;
small organs;
cerebrovascular system;
cardiology;
peripheric vessels;
urology;
pediatry;
locomotor system.

Complete package of measurements and calculations


in:

В (2D) mode;
М mode;
Dopplergraphy.

Modes:

1 B, M modes (black-and-white imaging)


   
1.1 Multifrequency formation of transmitted ultrasound beam;
1.2 Broadband formation of received ultrasound beam – change of bandpass ratio that changes
image parameters resolution – penetration;
1.3 Tissue (second) harmonic;
1.4 Inverse harmonic;
1.5 Multi-angle compound imaging;
1.6 Intellectual architecture filter;
1.7 Multiparameter filter;
1.8 Color maps;
1.9 Ultrasound velocity variation;
1.10 Dynamic noise rejection filter;
1.11 Time-averaged maximum velocity;
   
2 СF, РF and TD modes (color mapping)
   
2.1 Parallel reception of up to 4 ultrasound beams forming in one probing for increase in color
frame frequency;
2.2 Adaptive rejection wall filter, individual in each point of an ultrasound image for quality
monitoring of low-velocity flow at moving tissue background;
2.3 Interframe filter with separate filtration of blood flow increase and decrease for temporal
smoothing of color image;
2.4 Multiparameter filter of movement artefacts and aliasing, ensuring high sensitivity and
image dynamism;
2.5 Adaptive threshold of grey-scale image (8 shades), forming the blood flow image within a
vessel;
2.6 Multiparameter spatial filter for effective smoothing of flow image;
2.7 Semi-translucent image formation for simultaneous observation of tissues and blood flow
velocity (or simultaneous observation of tissues and tissue velocity);
2.8 Multiparameter adaptive filter of pulsating blood flows for arterial vessels mapping.
   
3 PW (pulse-wave) and CW (continuous-wave) spectral Doppler modes
   
3.1 Pulse-wave (PW) and continuous-wave (CW) spectral Doppler modes;
3.2 НРRF with frequency of up to 25 kHz in PW mode;
3.3 Duplex and triplex scanning modes;
3.4 Saving raw data in cineloop that enables controlling most of processing parameters and
repeated measurements in postprocessing;
3.5 Automatic routing of mean and maximum velocities;
3.6 Three types of Doppler measurements available - manual, semi-automatic and automatic;
3.7 Automatic computation of blood flow parameters (20 parameters) in real time and freeze
mode.

Beam forming:

digital;
multibeam parallel;
multiangle*;
multifrequency;
broadband.
* - ULTIMA SE EXPERT option

Configuration:

Configuration of ULTIMA series digital ultrasound diagnostic Doppler devices can be


modified with further improvement to meet your requirements.

The basic delivery set has a complete package of special measurement programs for all
investigation types.

High density probes (192 elements) can be supplied.


 
 
Price: 36 700$
Warranty period - up to 24 months.

Madis X-ray Digital Mammographic System


Madis X-ray Digital
Mammographic System is a modern tool
for diagnosing breast diseases. It enables
conducting all kinds of screening and
diagnostic breast examinations provided
in mammology. The system utilizes the
digital technology of obtaining
mammograms with image visualization
on the monitor screen, paper and film
media.

NO NEED in photolaboratory, X-ray


film, chemical agents

The system consists of an X-ray


stand device and workstations: X-ray
technician’s workstation and
radiotherapist’s diagnostic workstation.
The system is powered from a single-
phase AC network, 220 V, 50 Hz.

MADIS System provides:

Automatic or manual setting of exposure modes;


Higher diagnostic value of pictures due to digital processing of X-ray image (brightness
and contrast correction, filtering, zoom, determination of geometric parameters, positive
and negative images, rotation etc.);
Sending pictures over Internet (DICOM 3.0 format);
Recording and archiving pictures and medical opinions on paper, floppy disks, CD/DVD, in
computer memory;
Examinations in diagnostic mode — up to 20 patients per shift, in screening mode — up to
40 patients per shift.

Performance Specification:
Operational field, mm 240х180
Spatial resolution, line pairs/mm 8,0
X-ray tube voltage, kV 28…40
X-ray tube current, µA, max 200
Exposure time, s 0,1 to 9,0
Medium effective dose per picture, mSv 0,1
Threshold contrast at surface exposure dose of 1mR, %, max 2,0
Dynamic range 100
Gray gradations on the monitor screen 256
Archiving system On CD/DVD
Power consumption, W, max 500
 

 
MADIS Digital Mammographic System allows prompt and reliable diagnosing

Warranty period - up to 18 months.


 
Price: 105 000$

ALMHP-01 Apparatus for Microwave Local


Hyperthermy of Prostate
Apparatus for Microwave Local
Hyperthermy of Prostate:
– quick relief from men's problems;
– urinologist’s support;
– outpatient treatment of prostate
adenoma during single session.

ALMHP-01 apparatus is intended


for:
– treatment of benign hyperplasia of
prostate gland by the method of
transurethral microwave therapy;
– treatment of chronic nonspecific
prostatitis by the methods of transrectal
microwave hyperthermy and transrectal
vibratory massage.

Treatment of benign hyperplasia


(adenoma) of prostate gland by the
minimum invasive method of
transurethral microwave thermotherapy.

Guarantee of success in treatment


of prostatitis by the methods of transrectal
microwave hyperthermia and transrectal
vibratory massage.

The treatment session is carried


out automatically according to a program.

TREATMENT OF ADENOMA
Transurethral Microwave Thermotherapy
The applied method of transurethral microwave thermotherapy enables conducting the
treatment of prostate adenoma in an outpatient manner, during a single one-hour session.

This method is indicated for treatment of patients denied of surgical treatment because of
contraindications to anaesthesia, and patients willing to escape surgical interference in case of no
positive effect from pharmacotherapy.

The therapeutic effect is conditioned by adenomatous tissue modification after its heating
to 45…55 °С.

The action is applied locally by a microwave transducer inserted in the prostate gland
area with an urethral catheter that cools urethra during the treatment session.

The treatment session is conducted automatically according to a program. The physician


can make corrections during the session. The current values of temperature and power are
displayed on the screen.
The temperature is continuously monitored by an optical thermometric system. The
temperature is monitored in the center of the prostate gland in the area of the maximum
microwave action at the level of the urethral wall. To ensure the patient’s safety, the rectal wall
temperature is also monitored with three temperature sensors.

TREATMENT OF PROSTATITIS
Transrectal Microwave Hyperthermia
At transrectal microwave hyperthermia, the rectum wall and the area of posterolateral
surface of prostate gland is heated up to 41 to 43 °С.The effective heating layer depth is 1 to 2
cm.

The local action is applied by a miniature transducer of microwave energy. A special


temperature sensor placed in the maximum emission area provides for continuous monitoring of
the heating temperature and its maintaining at a set level. A special rectal catheter provides for
cooling of the rectum wall and protects it from overheating.

The elevated, as compared to diathermy, temperature and the cyclic heating mode
provide for higher therapeutic efficiency of the action.

As a result of microwave heating, the arterial and capillary blood flow is enhanced, the
number of actively functioning rectum wall and prostate gland capillars is increased, the lymph
flow is enhanced. The conducted treatment course results in normalization of the gland blood
circulation, the local tissue resistance is increased, and the inflammatory process is terminated.

To increase the efficiency of the action, thermotherapy by means of heating the fluid
circulating in this catheter is conducted simultaneously with vibratory massage.

The fluid temperature can be adjusted within 37 to 42 °С.

Unlike diathermy, darsonvalization, laser therapy, this method provides for stronger
action on the patient and his safety.

Transrectal Vibratory Massage


At transrectal vibration massage, the action, being a mechanical oscillation at a frequency
of 1 to 5 Hz and amplitude of 1 to 5 mm is transferred through the rectal wall to the area of
posterolateral surface of prostate gland and the urinary bladder fundus.

Such action results in improvement of the drainage function of acinuses, the increase of
the muscle tone of the prostate gland and rectum wall, enhancement of venous drainage, increase
in the number of active capillars.

Vibratory stimulant activates the adrenal pituitary-cortex system and increases the blood
content of glucocorticoid hormones of cortisone and hydrocortisone type with pronounced anti-
inflammatory effect. The vibratory massage is done using a special rectal catheter.
 

Performance Specifications:
Operating frequency, МHz 915±15
Output power adjusted with a step of 5 W in the range of, W 0...80
Absolute error of temperature measurement, °С, max 0,2
Vibration amplitude, mm 1...5
Vibration frequency, Hz 1...5
Overall dimensions, mm 565 х 940 х 425
Mass, kg, max 70
50 Hz, 220 V mains power consumption, VА, max 950
 

Delivery set:
basic device;
notebook (PC);
re-usable rectal catheter for treatment of adenoma;
set of single-use urethral catheters;
set of re-usable rectal catheters for treatment of prostatitis.
 
Single-use urethral catheter:  
 working part diameter, mm 6,5

 working part length, mm 500

Re-usable rectal catheters:  

 working part diameter, mm 20

 working part length, mm 120


 

ALMHP-01 - 
quick relief from men's problems,
urinologists’ support..

Price: 84 000$