You are on page 1of 7

LV 2C AL

DESCRIPTION
1 2 3 4 5 6 7 8 Name of Manufacturer Manufacturing Process Cable Type No. of Conductors Applicable Indian Standard Voltage Grade Permissible Voltage &Frequency Variation for Satisfactory operation Max.rated conductor temp for cont. operation

UNIT

REFERENCE
# CCV/VCV A2XWy / A2XFy 2 # 1.1 10%, 5% 90C 250C # # # Aluminium Stranded Circular or sector shaped

2C X 16

2C X 25

2C X 35

2C X 50

2C X 70

2C X 95

2C X 120

2C X 150

2C X 185

kV C C A A A

9 Max.allowable conductor temp.during short circuit 10 Continuous current carrying capacity When Laid in a) In air b) In Ground c) In duct 11 CONDUCTOR i) Material -ii) Shape -iii) Cross Sectional area a) Main conductor b) Neutral conductor iv) Number & Dia of wires 12 INSULATION i) Material ii) Nominal Thickness of insulation a) Main core b) Neutral core iii) Calculated dia over Insulation 13 Calculated laid up diameter 14 INNER SHEATH i) Material ii) Extruded or wrapped iii) Min. Thickness iv) Calculated dia over Inner Sheath 15 ARMOUR i) Material ii) Type of Armouring iii) Nom.Strip iv) Minimum thickness v) Calculated dia over armour vi)Short Ckt. Withstand Capacity 16 OUTER SHEATH i) Material ii) Nom.Thickness 17 Appr.Overall Dia. Of Cable 18 Appr.Weight of Cable 19 I)Drum Material II)Max. Length of cable per drum (Tolerance of +3% M) NO NEGATIVE TOLERANCE 20 Recommended min.Bending radious 21 Recommended temp. below which installation of cable should not be carried out 22 Marking on cables and cable drums as per MR 23 Design Life 24 Loss Tangent at 20 C 25 Max. Tensile strength i) for Cables pulled with stocking ii) for Cables pulled with pulling eyes Electrical Parameters 26 Short ckt. Current for 1 Sec 27 Max. DC Resistance at 20 C a) Main Conductor b) Neutral Conductor 28 Max.AC Resistance at 90 C 29 Calculated Star Reactance 30 Calculated Impedence 31 Appr.Capacitance 32 Insulation Resistance at 20 C 33 FR Propetrties on outer sheath Critical Oxygen Index Temparature Index

mm2 mm2 mm

# # # XLPE

mm mm mm mm

# # # # PVC Extruded # # Galvanised Steel Round Wires or strips

mm mm

mm mm kA/Sec

# # # PVC FR # # # Steel # # # # # # # # # # # # # # # # # Min. 29% Min. 250 C

mm mm kg/km m mm

Kg Kg kA Ohm/km Ohm/km Ohm/km Ohm/km Ohm/km mfd/km k

NOTE: " # " - Vendor to furnish as per IS

Page 1 of 7

LV 3C AL

DESCRIPTION
1 2 3 4 5 6 7 8 Name of Manufacturer Manufacturing Process Cable Type No. of Conductors Applicable Indian Standard Voltage Grade Permissible Voltage &Frequency Variation for Satisfactory operation Max.rated conductor temp for cont. operation

UNIT

REFERENCE
# CCV/VCV A2XWy / A2XFy 3 # 1.1 10%, 5% 90C 250C # # # Aluminium Stranded Circular or sector shaped

3C X 16

3C X 25

3C X 35

3C X 50

3C X 70

3C X 95

3C X 120

3C X 150

3C X 185

3C X 240

3C X 300

kV C C A A A

9 Max.allowable conductor temp.during short circuit 10 Continuous current carrying capacity When Laid in a) In air b) In Ground c) In duct 11 CONDUCTOR i) Material -ii) Shape --

12

13 14

15

iii) Cross Sectional area a) Main conductor b) Neutral conductor iv) Number & Dia of wires INSULATION i) Material ii) Nominal Thickness of insulation a) Main core b) Neutral core iii) Calculated dia over Insulation Calculated laid up diameter INNER SHEATH i) Material ii) Extruded or wrapped iii) Min. Thickness iv) Calculated dia over Inner Sheath ARMOUR i) Material ii) Type of Armouring iii) Nom.Strip iv) Minimum thickness v) Calculated dia over armour vi)Short Ckt. Withstand Capacity OUTER SHEATH i) Material ii) Nom.Thickness Appr.Overall Dia. Of Cable Appr.Weight of Cable I)Drum Material II)Max. Length of cable per drum (Tolerance of +3% M) NO NEGATIVE TOLERANCE Recommended min.Bending radious Recommended temp. below which installation of cable should not be carried out Marking on cables and cable drums as per MR Design Life Loss Tangent at 20 C Max. Tensile strength i) for Cables pulled with stocking ii) for Cables pulled with pulling eyes Electrical Parameters Short ckt. Current for 1 Sec Max. DC Resistance at 20 C a) Main Conductor b) Neutral Conductor Max.AC Resistance at 90 C Calculated Star Reactance Calculated Impedence Appr.Capacitance Insulation Resistance at 20 C FR Propetrties on outer sheath Critical Oxygen Index Temparature Index

mm2 mm2 mm

# # # XLPE

mm mm mm mm

# # # # PVC Extruded # # Galvanised Steel Single Layer/Double Layer, Round Wires/ strips

mm mm

mm mm kA/Sec

# # # PVC FR # # # Steel # # # # # # # # # # # # # # # # # Min. 29% Min. 250 C

16

17 18 19

mm mm kg/km m mm

20 21 22 23 24 25

Kg Kg kA Ohm/km Ohm/km Ohm/km Ohm/km Ohm/km mfd/km k

26 27

28 29 30 31 32 33

NOTE: " # " - Vendor to furnish as per IS

Page 2 of 7

LV 3C AL

DESCRIPTION
1 2 3 4 5 6 7 8 Name of Manufacturer Manufacturing Process Cable Type No. of Conductors Applicable Indian Standard Voltage Grade Permissible Voltage &Frequency Variation for Satisfactory operation Max.rated conductor temp for cont. operation

3C X 400

9 Max.allowable conductor temp.during short circuit 10 Continuous current carrying capacity When Laid in a) In air b) In Ground c) In duct 11 CONDUCTOR i) Material -ii) Shape --

12

13 14

15

iii) Cross Sectional area a) Main conductor b) Neutral conductor iv) Number & Dia of wires INSULATION i) Material ii) Nominal Thickness of insulation a) Main core b) Neutral core iii) Calculated dia over Insulation Calculated laid up diameter INNER SHEATH i) Material ii) Extruded or wrapped iii) Min. Thickness iv) Calculated dia over Inner Sheath ARMOUR i) Material ii) Type of Armouring iii) Nom.Strip iv) Minimum thickness v) Calculated dia over armour vi)Short Ckt. Withstand Capacity OUTER SHEATH i) Material ii) Nom.Thickness Appr.Overall Dia. Of Cable Appr.Weight of Cable I)Drum Material II)Max. Length of cable per drum (Tolerance of +3% M) NO NEGATIVE TOLERANCE Recommended min.Bending radious Recommended temp. below which installation of cable should not be carried out Marking on cables and cable drums as per MR Design Life Loss Tangent at 20 C Max. Tensile strength i) for Cables pulled with stocking ii) for Cables pulled with pulling eyes Electrical Parameters Short ckt. Current for 1 Sec Max. DC Resistance at 20 C a) Main Conductor b) Neutral Conductor Max.AC Resistance at 90 C Calculated Star Reactance Calculated Impedence Appr.Capacitance Insulation Resistance at 20 C FR Propetrties on outer sheath Critical Oxygen Index Temparature Index

16

17 18 19

20 21 22 23 24 25

26 27

28 29 30 31 32 33

NOTE: " # " - Vendor to furnish as per IS

Page 3 of 7

LV 3.5C AL

DESCRIPTION
1 2 3 4 5 6 7 8 Name of Manufacturer Manufacturing Process Cable Type No. of Conductors Applicable Indian Standard Voltage Grade Permissible Voltage &Frequency Variation for Satisfactory operation Max.rated conductor temp for cont. operation

UNIT

REFERENCE
# CCV/VCV A2XWy / A2XFy 3.5 # 1.1 10%, 5% 90C 250C # # # Aluminium Stranded Circular or sector shaped

3.5C X 25 3.5C X 35 3.5C X 50 3.5C X 70 3.5C X 95 3.5C X 120 3.5C X 150 3.5C X 185 3.5C X 240 3.5C X 300 3.5C X 400

kV C C A A A

9 Max.allowable conductor temp.during short circuit 10 Continuous current carrying capacity When Laid in a) In air b) In Ground c) In duct 11 CONDUCTOR i) Material -ii) Shape --

12

13 14

15

iii) Cross Sectional area a) Main conductor b) Neutral conductor iv) Number & Dia of wires INSULATION i) Material ii) Nominal Thickness of insulation a) Main core b) Neutral core iii) Calculated dia over Insulation Calculated laid up diameter INNER SHEATH i) Material ii) Extruded or wrapped iii) Min. Thickness iv) Calculated dia over Inner Sheath ARMOUR i) Material ii) Type of Armouring iii) Nom.Strip iv) Minimum thickness v) Calculated dia over armour vi)Short Ckt. Withstand Capacity OUTER SHEATH i) Material ii) Nom.Thickness Appr.Overall Dia. Of Cable Appr.Weight of Cable I)Drum Material II)Max. Length of cable per drum (Tolerance of +3% M) NO NEGATIVE TOLERANCE Recommended min.Bending radious Recommended temp. below which installation of cable should not be carried out Marking on cables and cable drums as per MR Design Life Loss Tangent at 20 C Max. Tensile strength i) for Cables pulled with stocking ii) for Cables pulled with pulling eyes Electrical Parameters Short ckt. Current for 1 Sec Max. DC Resistance at 20 C a) Main Conductor b) Neutral Conductor Max.AC Resistance at 90 C Calculated Star Reactance Calculated Impedence Appr.Capacitance Insulation Resistance at 20 C FR Propetrties on outer sheath Critical Oxygen Index Temparature Index

mm2 mm2 mm

# # # XLPE

mm mm mm mm

# # # # PVC Extruded # # Galvanised Steel Single Layer/Double Layer, Round Wires/ strips

mm mm

mm mm kA/Sec

# # # PVC FR # # # Steel # # # # # # # # # # # # # # # # # Min. 29% Min. 250 C

16

17 18 19

mm mm kg/km m mm

20 21 22 23 24 25

Kg Kg kA Ohm/km Ohm/km Ohm/km Ohm/km Ohm/km mfd/km k

26 27

28 29 30 31 32 33

NOTE: " # " - Vendor to furnish as per IS

Page 4 of 7

LV 4C AL

DESCRIPTION
1 2 3 4 5 6 7 8 Name of Manufacturer Manufacturing Process Cable Type No. of Conductors Applicable Indian Standard Voltage Grade Permissible Voltage &Frequency Variation for Satisfactory operation Max.rated conductor temp for cont. operation

UNIT

REFERENCE
# CCV/VCV A2XWy / A2XFy 4 # 1.1 10%, 5% 90C 250C # # # Aluminium Stranded Circular or sector shaped

4C X 16

4C X 25

4C X 35

4C X 50

4C X 70

4C X 95

4C X 120

4C X 150

kV C C A A A

9 Max.allowable conductor temp.during short circuit 10 Continuous current carrying capacity When Laid in a) In air b) In Ground c) In duct 11 CONDUCTOR i) Material -ii) Shape --

12

13 14

15

16

17 18 19

20 21 22 23 24 25

26 27

28 29 30 31 32 33

iii) Cross Sectional area a) Main conductor b) Neutral conductor iv) Number & Dia of wires INSULATION i) Material ii) Nominal Thickness of insulation a) Main core b) Neutral core iii) Calculated dia over Insulation Calculated laid up diameter INNER SHEATH i) Material ii) Extruded or wrapped iii) Min. Thickness iv) Calculated dia over Inner Sheath ARMOUR i) Material ii) Type of Armouring iii) Nom.Strip iv) Minimum thickness v) Calculated dia over armour vi)Short Ckt. Withstand Capacity OUTER SHEATH i) Material ii) Nom.Thickness Appr.Overall Dia. Of Cable Appr.Weight of Cable I)Drum Material II)Max. Length of cable per drum (Tolerance of +3% M) NO NEGATIVE TOLERANCE Recommended min.Bending radious Recommended temp. below which installation of cable should not be carried out Marking on cables and cable drums as per MR Design Life Loss Tangent at 20 C Max. Tensile strength i) for Cables pulled with stocking ii) for Cables pulled with pulling eyes Electrical Parameters Short ckt. Current for 1 Sec Max. DC Resistance at 20 C a) Main Conductor b) Neutral Conductor Max.AC Resistance at 90 C Calculated Star Reactance Calculated Impedence Appr.Capacitance Insulation Resistance at 20 C FR Propetrties on outer sheath Critical Oxygen Index Temparature Index

mm2 mm2 mm

# # # XLPE

mm mm mm mm

# # # # PVC Extruded # # Galvanised Steel Round Wires or strips

mm mm

mm mm kA/Sec

# # # PVC FR # # # Steel # # # # # # # # # # # # # # # # # Min. 29% Min. 250 C

mm mm kg/km m mm

Kg Kg kA Ohm/km Ohm/km Ohm/km Ohm/km Ohm/km mfd/km k

NOTE: " # " - Vendor to furnish as per IS

Page 5 of 7

LV 1C AL AMOURED

DESCRIPTION
1 2 3 4 5 6 7 8 Name of Manufacturer Manufacturing Process Cable Type No. of Conductors Applicable Indian Standard Voltage Grade Permissible Voltage &Frequency Variation for Satisfactory operation Max.rated conductor temp for cont. operation

UNIT

REFERENCE
# CCV/VCV A2XWay/A2XWaWay/A 2XFay/A2XFay 1 # 0.66 10%, 5% 90C 250C # # # Aluminium Stranded Circular or sector shaped

1C X 240

1C X 300

1C X 400

1C X 630

1C X 1000

kV C C A A A

9 Max.allowable conductor temp.during short circuit 10 Continuous current carrying capacity When Laid in a) In air b) In Ground c) In duct 11 CONDUCTOR i) Material -ii) Shape --

12

13 14

15

iii) Cross Sectional area a) Main conductor b) Neutral conductor iv) Number & Dia of wires INSULATION i) Material ii) Nominal Thickness of insulation a) Main core b) Neutral core iii) Calculated dia over Insulation Calculated laid up diameter INNER SHEATH i) Material ii) Extruded or wrapped iii) Min. Thickness iv) Calculated dia over Inner Sheath ARMOUR i) Material ii) Type of Armouring iii) Nom.Strip iv) Minimum thickness v) Calculated dia over armour vi)Short Ckt. Withstand Capacity OUTER SHEATH i) Material ii) Nom.Thickness Appr.Overall Dia. Of Cable Appr.Weight of Cable I)Drum Material II)Max. Length of cable per drum (Tolerance of +3% M) NO NEGATIVE TOLERANCE Recommended min.Bending radious Recommended temp. below which installation of cable should not be carried out Marking on cables and cable drums as per MR Design Life Loss Tangent at 20 C Max. Tensile strength i) for Cables pulled with stocking ii) for Cables pulled with pulling eyes Electrical Parameters Short ckt. Current for 1 Sec Max. DC Resistance at 20 C a) Main Conductor b) Neutral Conductor Max.AC Resistance at 90 C Calculated Star Reactance Calculated Impedence Appr.Capacitance Insulation Resistance at 20 C FR Propetrties on outer sheath Critical Oxygen Index Temparature Index

mm2 mm2 mm

# # # XLPE

mm mm mm mm

# # # # NA NA NA NA Aluminum Single Layer or Double Layer Round Wires

mm mm

mm mm kA/Sec

# # # PVC FR black colored # # # Steel # # # # # # # # # # # # # # # # # Min. 29% Min. 250 C

16

17 18 19

mm mm kg/km m mm

20 21 22 23 24 25

Kg Kg kA Ohm/km Ohm/km Ohm/km Ohm/km Ohm/km mfd/km k

26 27

28 29 30 31 32 33

NOTE: " # " - Vendor to furnish as per IS

Page 6 of 7

LV 1C AL UNARMOURD

DESCRIPTION
1 2 3 4 5 6 7 8 Name of Manufacturer Manufacturing Process Cable Type No. of Conductors Applicable Indian Standard Voltage Grade Permissible Voltage &Frequency Variation for Satisfactory operation Max.rated conductor temp for cont. operation

UNIT

REFERENCE
# CCV/VCV AYy 1 # 0.66 10%, 5% 90C 250C # # # Aluminium Stranded Circular or sector shaped

1C X 16

1C X 25

1C X 35

1C X 50

1C X 70

1C X 95

1C X 150

1C X 185

1C X 240

kV C C A A A

9 Max.allowable conductor temp.during short circuit 10 Continuous current carrying capacity When Laid in a) In air b) In Ground c) In duct 11 CONDUCTOR i) Material -ii) Shape --

12

13 14

15

16

iii) Cross Sectional area a) Main conductor b) Neutral conductor iv) Number & Dia of wires INSULATION i) Material ii) Nominal Thickness of insulation a) Main core b) Neutral core iii) Calculated dia over Insulation Calculated laid up diameter INNER SHEATH i) Material ii) Extruded or wrapped iii) Min. Thickness iv) Calculated dia over Inner Sheath ARMOUR i) Material ii) Type of Armouring iii) Nom.Strip iv) Minimum thickness v) Calculated dia over armour vi)Short Ckt. Withstand Capacity OUTER SHEATH i) Material

mm2 mm2 mm

# # # XLPE

mm mm mm mm

# # # # NA NA NA NA NA NA NA NA NA NA NA PVC FR Green Colored with Yellow Strip # # # Steel # # # # # # # # # # # # # # # # # Min. 29% Min. 250 C

mm mm

mm mm kA/Sec

ii) Nom.Thickness 17 Appr.Overall Dia. Of Cable 18 Appr.Weight of Cable 19 I)Drum Material II)Max. Length of cable per drum (Tolerance of +3% M) NO NEGATIVE TOLERANCE 20 Recommended min.Bending radious 21 Recommended temp. below which installation of cable should not be carried out 22 Marking on cables and cable drums as per MR 23 Design Life 24 Loss Tangent at 20 C 25 Max. Tensile strength i) for Cables pulled with stocking ii) for Cables pulled with pulling eyes Electrical Parameters 26 Short ckt. Current for 1 Sec 27 Max. DC Resistance at 20 C a) Main Conductor b) Neutral Conductor 28 Max.AC Resistance at 90 C 29 Calculated Star Reactance 30 Calculated Impedence 31 Appr.Capacitance 32 Insulation Resistance at 20 C 33 FR Propetrties on outer sheath Critical Oxygen Index Temparature Index

mm mm kg/km m mm

Kg Kg kA Ohm/km Ohm/km Ohm/km Ohm/km Ohm/km mfd/km k

NOTE: " # " - Vendor to furnish as per IS

Page 7 of 7