You are on page 1of 11

Exam Title

: IBM 000-867 : IBM Eserver Iseries Technical Solutions Implementation V5R3

Version : R6.1

www.Prepking.com

Prepking - King of Computer Certification Important Information, Please Read Carefully


Other Prepking products A) Offline Testing engine Use the offline Testing engine product to practice the questions in an exam environment. B) Study Guide (not available for all exams) Build a foundation of knowledge which will be useful also after passing the exam. Latest Version We are constantly reviewing our products. New material is added and old material is updated. Free updates are available for 90 days after the purchase. You should check your member zone at Prepking and update 3-4 days before the scheduled exam date. Here is the procedure to get the latest version: 1.Go towww.Prepking.com 2.Click on Member zone/Log in (right side) 3. Then click My Account 4.The latest versions of all purchased products are downloadable from here. Just click the links. For most updates,it is enough just to print the new questions at the end of the new version, not the whole document. Feedback If you spot a possible improvement then please let us know. We always interested in improving product quality. Feedback should be send to feedback@Prepking.com. You should include the following: Exam number, version, page number, question number, and your login ID. Our experts will answer your mail promptly. Copyright Each PDF file contains a unique serial number associated with your particular name and contact information for security purposes. So if we find out that a particular PDF file is being distributed by you, Prepking reserves the right to take legal action against you according to the International Copyright Laws. Explanations This product does not include explanations at the moment. If you are interested in providing explanations for this exam, please contact feedback@Prepking.com.

www.Prepking.com

1. A customer has an HMC hardware problem. How should the customer obtain service for the HMC?

A. Report the problem as an iSeries hardware problem. B. Report the problem as an HMC hardware machine problem. C. Report the problem as an xSeries hardware problem. D. Report the problem as a pSeries hardware problem. Answer: B 2. An iSeries customer is creating a partition to support Linux applications. They have a 3580-H11 and

need to maintain file level backups of the Linux data. Which of the following will accomplish this? A. Add an LVD type LTO for Linux backups. B. Switch the tape IOP to the Linux partition. C. Use the SAV command with the FILELVL(*YES) parameter to save the storage spaces. D. Use an NFS device share to the Linux partition to save the data to the OS/400 tape device. Answer: A 3. An eServer i5 system has a Fibre Channel attached LTO-2 tape, which uses an LTO "2U" drive. Which of the following describes the required service considerations for the tape drive? A. The drive microcode updates are in the MHxxxx PTFs. B. The RMU for the tape drive must be the same subnet as the service processor so that drive microcode updates can be installed by the i5. C. Tape drive firmware updates must be enabled in SST/DST of the i5/OS partition designated as the "Service Partition." D. A PC must be available to update the tape drive microcode, which is downloaded from IBM Total Storage division's Web site. Answer: D 4. An AS/400 customer is migrating to a new iSeries machine. The software cannot experience more than five minutes of down time a month due to operational constraints. Which of the following is the most reliable way to implement the new machine without possibility of data loss? A. Implement Virtual OptiConnect's SQL feature between the AS/400 and iSeries. B. Put remote journals on the iSeries machines to update the database with roll forward. C. Utilize high availability software on both machines to synchronize the data prior to implementation of the iSeries. D. Use SAVRSTOBJ to back up the journals on the AS/400 and restore them on the iSeries, then roll the journals forward on the iSeries. Answer: C 5. An iSeries customer is consolidating to an eServer i5 570 from an i810 and an i825, each with two partitions and one expansion tower. Which of the following must be considered in order to provide a

www.Prepking.com

successful consolidation? A. The bus numbers in the towers will change. B. iSeries Navigator Management Central will combine the partition information for both systems and restore it. C. The Hypervisor must be slip-installed to accommodate the consolidated systems. D. The disk units must be write-enabled after the migration. Answer: A 6. Which two group PTFs are shipped along with a cumulative PTF package? A. Database and Java groups B. Database and HIPER groups C. Java and HTTP Server groups D. HTTP Server and HIPER groups Answer: B 7. A customer wants to implement the WebSM HMC client on a laptop running Windows XP. The HMC is

defined in the customer's network as HMCONE; an i5/OS partition on the eServer i5 system is on the network as PARTITION1. The laptop is able to ping both HMCONE and PARTITION1. Which of the

following describes from where the WebSM client is obtained for installation on the laptop? A. WebSM plug-in from iSeries Navigator on PARTITION1 B. http://PARTITION1:2000/WebSM C. http://HMCONE/Remote_Client.html D. HMC CDs shipped with HMCONE Answer: C 8. When installing an eServer i5 520 and FC #0595 in a customer supplied rack with cable management, what is the shortest length HSL-2/RIO-G cable that can be used? A. 1.75m B. 2.5m C. 3.5m D. 6.0m Answer: B 9. User management has decided to track average and maximum interactive response times in a partition dedicated to order entry transactions. Management wants immediate notification when response times reach a specific threshold. What method will accomplish this task?

A. Use the CRTPFRMON command to create a performance monitor with the interactive threshold limit set. B. Create a performance monitor in Management Central to monitor response times in the order entry partition.

www.Prepking.com

C. Create a command definition in Management Central to monitor all the partitions on the machine and put an event alert in the order entry partition. D. Use Performance Tools management feature to set an interactive response time threshold on the order entry partition and send a break message to the system operator. Answer: B 10. A new iSeries has been installed and the customer has chosen not to allow automatic performance adjustment. The system is experiencing performance problems affecting all jobs (batch and interactive). CPU utilization is under 60%, and the disk arms are all under 10% busy. What is the most likely cause of this performance problem? A. Batch and interactive jobs are running at the same priority level. B. The machine pool has insufficient main storage. C. There are too many interactive jobs active at once. D. There are too many activity levels assigned to the base pool. Answer: B 11. A customer has implemented three independent ASPs, one each for production, QA, and development. The users have been unable to access the QA environment. Which of the following is a probable cause? A. The users do not have authority to the iASP device description. B. The initial program for each user did not add both the production and QA environments to the user's library list. C. A library in the QA environment is not enabled to be used in the iASP environment. D. The job descriptions used for the QA environment are stored in *SYSBAS pool. Answer: A 12. In addition to *SECADM, which special authority is needed to ensure the ability to create, maintain, and delete all user profiles? A. *USRADM B. *ALLOBJ C. *SERVICE D. *IOSYSCFG Answer: B 13. An i825 customer running V5R2 wants to access iSeries Navigator functions using a browser. Which of the following must be done to enable this capability? A. Upgrade to V5R3. B. Install iSeries Access for the Web on the client PC. C. Install IBM WebSphere Host Access Transformation Server (HATS) on the client PC. D. Install IBM Personal Communications on the client PC.

www.Prepking.com

Answer: A 14. An eServer i5 520 configuration includes the system unit, two FC #5095 towers, and two IXA attached xSeries servers. When cabling this system, what is the recommended placement for the units in the HSL loop? A. 520 -> IXA -> FC #5095 -> FC #5095 -> IXA -> 520 B. 520 -> IXA -> FC #5095 -> IXA -> FC #5095 -> 520 C. 520 -> FC #5095 -> IXA -> IXA -> FC #5095 -> 520 D. 520 -> FC #5095 -> FC #5095 -> IXA -> IXA -> 520 Answer: C 15. Which of the following must be available to install AIX 5L V5.3 on an eServer i5? A. A dedicated processor B. At least .10 Shared Processing Units C. At least .25 Shared Processing Units D. At least .50 Shared Processing Units Answer: B 16. An eServer i5 550 has two internal xSeries servers (IXS). Each IXS will communicate with i5/OS over the virtual LAN. What is the minimum number of IP addresses needed for all of the interfaces for both the

iSeries and IXS servers? A. 3 B. 5 C. 6 D. 7 Answer: C 17. A customer has an i820 and a FC #5074 PCI Expansion Tower with 27 17GB 10K RPM drives supported by two FC #4748 RAID controllers. The system is being migrated into an LPAR of an eServer i5

system by migrating the disk units into a FC #5094 tower with FC #2780 RAID controllers. The i820 is running V5R3 with current PTFs. Which of the following is required to ensure a successful migration? A. Perform a Save 21 of the i820. Move the drives into cages of the FC #5094. Bring up the partition. B. Stop RAID on the i820. Move the drives into cages of the FC #5094. Bring up the partition. Restart RAID on the drives to enable the new RAID striping. C. Perform a SAVLIB *ALLUSR. Move the drives to cages in the FC #5094. Bring up the partition.

D. Perform a Save 21 of the i820. Re-kit the drives for the FC #5094. Install the drives into cages of the FC #5094. Bring up the partition. Answer: A 18. The customer has an i830 with the following logical partitions:

www.Prepking.com

Partition 0 is V5R2 Partition 1 is V5R1 Partition 2 is LINUX Partition 3 is V5R3. Which partitions support dynamic movement of memory? A. 0,3 B. 0,1,2 C. 0,1,3 D. 0,1,2,3 Answer: C 19. What is the general rule for support of multiple OS/400 releases with Management Central? A. n+2 release from the central system B. n-2 release from the central system C. All systems must be at the same release of the central system. D. Either n+2 or n-2 release from the central system Answer: D 20. An iSeries machine shows the following output after issuing the DSPPTF command: IPL source ##MACH#A ##SERV#A MF12345 MF12344 Temp Applied Perm Applied

PTF MF12346 needs to be installed temporarily and supersedes MF12345. The cover letter states that an IPL is required to activate the PTF. What are the appropriate actions to install PTF MF12346? A. Load and Apply PTF MF12346, IPL from B B. Load and Apply PTF MF12346, IPL from A C. IPL from B, Load and Apply PTF MF12346, IPL from B D. Permanently Apply MF12345, IPL from B side, Load and Apply MF12346, IPL from A Answer: C 21. Which of the following special authorities will allow the output queue of a spooled file to be changed? A. *ALLOBJ B. *JOBCTL C. *SERVICE D. *IOSYSCFG Answer: B 22. An iSeries customer is running a system with three tape drives. They would like the tape drive names How can they accomplish

to indicate the media supported (e.g., TAPREEL, TAP8MM, TAPQIC, etc.).

www.Prepking.com

this? A. Set the QTAPNAMING system value to *TYPE. B. Change the device names with the RNMOBJ command. C. Change the device names with the CHGDEVTAP command. D. Delete current devices and allow AUTOCFG to recreate the devices. Answer: B 23. A customer has a 3590 Model E11 installed using a PCI tape adapter in an existing AS/400e Model 740. A processor upgrade to an i840 is being planned. What changes are needed to ensure the highest possible tape performance? A. Install an HSL loop and install an HSL adapter on the 3590. B. Migrate the existing tape adapter to Bus 0 of the i840 system unit. C. Install an HSL loop and include the existing tape adapter for the 3590 in the Migration Tower on the i840. D. Install a PCI Fibre Channel tape controller in the i840 and install a Fibre Channel feature conversion on the 3590. Answer: D 24. A customer wants to automate their backup process without requiring additional software, programming, or operator intervention. Which of the following could be recommended as a solution for this customer? A. Use Operational Assistant. B. Use the SAVCHGLIB command. C. Use the CHGBKPA command to enable automatic backups. D. Use the SAVE Menu - Option 21 to save the entire system. Answer: A 25. A new iSeries system has just been powered up for the first time. configuration, which device(s) will allow a user to sign on? A. All devices B. Any twinax terminal C. The system console only D. The system console and any virtual devices Answer: C 26. A customer is migrating a new third-party application software package to the iSeries server. In which of the following areas would conflicts negatively impact coexistence with existing applications? A. Shared pools B. User classes C. Output queues D. User profiles With the default security

www.Prepking.com

Answer: D 27. A customer is upgrading the HMC microcode. They downloaded the upgrade zip from IBM's Web site to a PC with a CD burner. The HMC upgrade process is posting an error that the update CD image has

been corrupted. Which of the following is the most likely cause of the problem? A. The option to retain the zip file's directory structure was not selected when the zip file was unpacked. B. The zip file from IBM's Web site should have been copied directly to the CD. C. The CD should have been created with the Linux dd command in order to be used for the upgrade. D. The PC's anti-virus software was active while the zip file was being unpacked. Answer: A 28. An iSeries customer's central site system administrator requires the ability to control system consoles in remote datacenters. enable this activity? A. Set the QCSLCTL system value in each partition to allow remote control of the partition console. B. Use the "Configure LAN Adapter" option in SST/DST to enable the Administrator's IP address on the LAN console. C. Configure each remote system's LAN Console workstation as a Remote Controlling System (RCS). D. In DST/SST, create a device profile for the Administrator's workstation. Answer: D 29. An eServer i5 520 customer has 140 GB of unprotected disk storage at 60% utilization, using 35 GB disk units. The customer would like to implement mirroring in the system unit. features will be required? A. FC# 5709 RAID Enabler Card and the FC# 6574 4-Disk Slot Expansion-Base Controller and four additional 35 GB disk units B. FC# 5709 RAID Enabler Card and four additional 35 GB disk units C. FC# 6574 4-Disk Slot Expansion-Base Controller and four additional 35 GB disk units D. Four additional 35 GB disk units Answer: C 30. When recovering to a different system, which restore parameters must be used to ensure object security is restored to the original state for libraries? A. MBROPT(*ALL) and OPTION(*ALL) B. MBROPT(*ALL) and ALWOBJDIF(*ALL) C. ALWOBJDIF(*ALL) and OPTION(*ALL) D. ALWOBJDIF(*ALL) and MBROPT(*ALL) and OPTION(*ALL) Answer: B 31. Which of the following methods is used to move a disk unit from the System Auxiliary Storage Pool What eServer i5 hardware All systems are using LAN Console. Which of the following should be done first to

www.Prepking.com

(ASP) to an Independent Auxiliary Storage Pool? A. Start SST and Work with disk units. B. Start DST and Work with disk units. C. Move the disk with the WRKDSKPOOL command. D. Use the HMC disk configuration tool to move the disk unit. Answer: B 32. A customer is migrating from a Model 720 to an eServer i5 520. They want to validate the performance

improvement after migrating to the new system. Which statement defines the correct method of verifying the application's performance on the 520? A. Run STRPFRMON on both systems and compare CPU utilization on both systems. B. Run WRKSYSSTS on both systems and compare the CPU utilization on both machines. C. Have users manually measure response time of the applications on both systems and document the results. D. Run the Management Central system monitor on both systems with the same users and job mix to produce system reports for analysis. Answer: D 33. What can be done to keep critical QSYSOPR messages such as hardware failures and critical storage conditions from being overlooked? A. Put QHST log in break mode. B. Use DSPLOG to find the critical messages of concern. C. Change the QSYSOPR message queue to break mode at severity 90. D. Create the QSYSMSG message queue in library QSYS and monitor that queue. Answer: D 34. A program which ran correctly during the previous hour has now halted with the following error: CPF4131 - Level check on file ABC in library XYZ. Library XYZ and all files in it were created via SQL; the program with the error is an RPG IV program. Which of the following will help determine why the file no longer matches the description the program expects? A. Use DSPLOG starting at the time the program last ran successfully looking for entries describing changes made to the file description. B. Use DSPMSG QSYSOPR starting at the time the program last ran successfully looking for entries describing changes made to the file description. C. Use DSPJRN on XYZ/QSQJRN starting at the time the program last ran successfully looking for entries describing changes made to the file description. D. Use DSPJRN on QSYS/QDBJRN starting at the time the program last ran successfully looking for

www.Prepking.com

100% Pass Guaranteed or Full Refund Word to Word Real Exam Questions from Real Test Buy full version of exam from this link below http://www.prepking.com/000-867.htm

You might also like