You are on page 1of 2

Proeject:- CSPGCL Korba West

Customer:- Tecpro
Application:- Conveyor drives

Annexure-A

Head
pulley
speed in
rpm

Full load
Rated
torque in
Nm

Max./
Roll Back
Starting Torque at
torque in
pulley
Nm
Shaft, Nm

Sr. No.

Conv. No.

Consumed
power in Kw on
pulley shaft

1
2
3
4
5
6

BCN-31A
BCN-31B
BCN-32A
BCN-32B
BCN-33A
BCN-33B

61.60
61.60
55.50
55.50
107.70
107.70

93
93
93
93
93
93

6325
6325
5730
5730
11118
11118

7590
7590
6876
6876
13342
13342

1616
1616
1705
1705
1504
1504

BCN-34A

174.60

93

18025

21630

10842

8
9
10
11
12
13
14
15

BCN-34B
BCN-35A
BCN-35B
BCN-36A
BCN-36B
BCN-37A
BCN-37B
BCN-7B

174.60
143.80
143.80
68.50
68.50
68.50
68.50
118.20

93
93
93
93
93
93
93
93

18025
14845
14845
7072
7072
7072
7072
12202

21630
17814
17814
8486
8486
8486
8486
14642

10842
5750
5750
2094
2094
2094
2094
NA

Date:-24.12.2010
Rev 2

Hydraulic motor

Pump

Installed
Kw.
( E motor
excluded)

CA50-32
CA50-32
CA50-32
CA50-32
CA50
CA50
CA100-80
CA100-80
CA100-80
CA100-80
CA50-32
CA50-32
CA50-32
CA50-32
CA70

SP180
SP180
SP180
SP180
SP250
SP250
2XSP180
2XSP180
2XSP180
2XSP180
SP180
SP180
SP180
SP180
SP355

90
90
75
75
160
160
2X132
2X132
2X110
2X110
90
90
90
90
160

PEC Model

Price in SEK
(Ex works
Sweden)

PEC403-180/180-90/90

1,075,000

PEC403-180/180-75/75

1,065,000

PEC603-250/250-160/160

1,150,000

PEC403-180/180-132/132
PEC403-180/180-132/132
PEC403-180/180-110/110
PEC403-180/180-110/110

985,000
985,000
975,000
975,000

PEC403-180/180-90/90

1,075,000

PEC403-180/180-90/90

1,075,000

302-355-160
Total value in SEK

725,000
10,085,000

Important Notes and deviations:1. Air oil cooler are designed on the basis of consumed power of conveyor drive and suitable for 50deg ambient.
2. Electric motors of power unit are excluded from scope of supply, designing of power unit is done on basis of ABB India electric motors only.
3.No standby pump and electric motor is considered.
4. While designing the drive system, hydraulic motor and power unit are considered on the same floor level and at disctance of 10-15m.
5. Duplex filter is not considered in system.
6. Hydraulic piping is excluded from scope.
7. Parking lock unit is considered to restrict the roll back of conveyor where ever applicable.
8. Conv No. 31AB, 32AB, 33AB,36AB,37AB have common power unit, with dedicated hydraulic pump and electric motor for each coneyor.Spider controller is common.
9. Cooler electric motors will be as per our standard supply from Europe.

Annexure-B

Proeject:- CSPGCL Korba West


Customer:- Tecpro
Application:- Conveyor drives, External CHP
Roll
Consumed
Head Full load Max./
Back
power in
Sr.
pulley
Rated
Starting Torque
Conv. No.
Kw on
No.
speed torque in torque in at pulley
pulley
Nm
Nm
Shaft,
in rpm
shaft
Nm

Hydraulic
motor

Pump

2
2
2
2
1
2
2
1

1
2
3
4
5
6
7
8

BCN-4C
BCN-5C
BCN-6C
BCN-7C
BCN-8C
BCN-9C
BCN-10C
BCN-11C1

221
210
142
200
54
155
165
127

93
93
93
93
93
93
93
93

22763
21679
14659
20596
5585
15950
16982
13059

27316
26015
17591
24715
6702
19140
20379
15671

N/A
N/A
N/A
N/A
334
N/A
N/A
721

CA 100
CA 100
CA 100-80
CA 100
CA 50-32
CA 100-80
CA 100-80
CA 100-80

BCN-12C

178

93

18324

21989

N/A

10

PC

2X330

120

2X26261

2X31513

N/A

Important Notes and deviations:-

Date:-15.2.2011
Rev: 2

x
x
x
x
x
x
x
x

Installed
Kw.
( E motor
excluded)

PEC Model

Price in SEK (Ex


works Sweden)

250
250
180
250
180
180
180
355

2X160
2X132
2X110
2X132
1X90
2X110
2X110
1X160

PEC
PEC
PEC
PEC

603-250/250-160/160
603-250/250-132/132
403-180/180-110/110
603-250/250-132/132
PEC 402-180-90
PEC 403-180/180-110/110
PEC 403-180/180-110/110
PEC 402-355-160

965,000
947,000
915,000
947,000
633,000
915,000
915,000
773,000

CA 100

2 x 250

2X132

PEC 603-250/250-132/132

947,000

2 XCBP 140120

4 x 355

2X400

PEC 1203355+355/355+355-400/400
Total price in SEK

1. Air oil cooler are designed on the basis of consumed power of conveyor drive and suitable for 50deg ambient.
2. Electric motors of power unit are excluded from scope of supply, designing of power unit is done on basis of ABB India electric motors only.
3.No standby pump and electric motor is considered.
4. While designing the drive system, hydraulic motor and power unit are considered on the same floor level and at disctance of 10-15m.
5. Duplex filter is not considered in system.
6. Hydraulic piping is excluded from scope.
7. Parking lock unit is considered to restrict the roll back of conveyor where ever applicable.
8. Pipe conveypr PC will be driven by two nos. of hydraulic motor with common power unit.
9. Cooler electric motors will be as per our standard supply from Europe.