You are on page 1of 30

Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Agenda
Page Introduction and Install of DIALux Import IES files of OSRAM LEDs Quick Street Planning Wizard with DIALux Step by Step Design with OSRAM LEDs in DIALux 3 8 12 20

Event / Title | December 17, 2008 | Page 2


SSL | Application Design Center Asia | V.Chen

What is special about DIALux?


DIALux - a planning software for your project presentation. Calculation: latest radiosity procedures, fast and always correct. Results: Results can be printed out or transmitted as a pdf file. Each view and each rendering can be saved as a .jpg file. Interactive 3-D visualization: Simply move around the room. Visualization: Use of textures and furniture for realistic rendering. Photo realism: with integrated raytracing module. False colours: False colours provide quantitative analysis of complex geometries at a glance. Movies: Walk through the photo realistic visualization of your light planning and send the film to your customer via email. Interaction: Import and export: .dwg and .dxf files can be imported and exported with results after completion of the planning process. DIALux Light: Easy to use, step-by-step lighting design.

Event / Title | December 17, 2008 | Page 3


SSL | Application Design Center Asia | V.Chen

Free Download DIALux from website


Download the DIALux Setup (version DIALux 4.5.0.1 ) from homepage (www.DIAL.de or www.dialux.com) on your hard-disk. Language available deutsch english franais italiano espaol Download file size: about 250MB
www.DIAL.de or www.dialux.com

Event / Title | December 17, 2008 | Page 4


SSL | Application Design Center Asia | V.Chen

Online Update
If you have already installed old version of DIALux, you could use online update to newest version. In DIALux you will find a new menu named Online. After selecting Online Update DIALux automatically checks for newer versions of the software and for new online PlugIns. But it will take some time to finish update.

Event / Title | December 17, 2008 | Page 5


SSL | Application Design Center Asia | V.Chen

The DIALux User Interface


These three work areas enable effective and clearly arranged planning of lighting installation with DIALux.
CAD-Window Task Pane

Project manager with Inspector

Event / Title | December 17, 2008 | Page 6


SSL | Application Design Center Asia | V.Chen

Agenda
Page Introduction and Install of DIALux Import IES files of OSRAM LEDs Quick Street Planning Wizard with DIALux Step by Step Design with OSRAM LEDs in DIALux 3 8 12 20

Event / Title | December 17, 2008 | Page 7


SSL | Application Design Center Asia | V.Chen

.IES or .Idt files


.IES or .Idt file describe the information of light distribution, luminous flux, and power. .IES or .Idt file are very small ( only about 10K) compared to ray data (about 200M). OSRAM OS provide both .IES (or .Idt) file and ray data of our LED products on website.

Event / Title | December 17, 2008 | Page 8


SSL | Application Design Center Asia | V.Chen

Download .IES file of OSRAM LED from website


http://www.ledlightforyou.com
Tools & Downloads >> Optical Tools

Event / Title | December 17, 2008 | Page 9


SSL | Application Design Center Asia | V.Chen

Import .IES file to DIALux

Event / Title | December 17, 2008 | Page 10


SSL | Application Design Center Asia | V.Chen

Agenda
Page Introduction and Install of DIALux Import IES files of OSRAM LEDs Quick Street Planning Wizard with DIALux Step by Step Design with OSRAM LEDs in DIALux 3 8 12 20

Event / Title | December 17, 2008 | Page 11


SSL | Application Design Center Asia | V.Chen

Quick Street Planning Wizard

This wizard guides you through the quick planning for streets.

you will find the wizards in the menu File >> Wizard

Event / Title | December 17, 2008 | Page 12


SSL | Application Design Center Asia | V.Chen

Street profile and illumination class

Street profile Street name and maintenance factor are likewise inserted on this page. In the following window you can fix the individual or combined valuation fields for the street. In order to define photometric requirements for the street, select an illumination class for every valuation field.
Event / Title | December 17, 2008 | Page 13
SSL | Application Design Center Asia | V.Chen

Luminaire arrangement

In the window Luminaire arrangement you can select a luminaire and place this in an arrangement. (You need to import the IES file of OSRAM LEDs first, otherwise you can only select the existing traditional luminaire in DIALux) You can optimize the arrangement parameters depending on the predefined photometric requirements.
Event / Title | December 17, 2008 | Page 14
SSL | Application Design Center Asia | V.Chen

Start Calculation

Afterwards a final dialogue will appear automatically. If you activate the checkbox, the generated street will be calculated immediately. Click on the Finish button and your street project will be displayed.

Event / Title | December 17, 2008 | Page 15


SSL | Application Design Center Asia | V.Chen

Rotate 3D View

Rotate 3D View; left-click and move the mouse while holding the mouse button pressed.

Event / Title | December 17, 2008 | Page 16


SSL | Application Design Center Asia | V.Chen

3D light distribution Display


Help Rays for Luminaires / 3D light distribution Display / Show false colors in CAD

Event / Title | December 17, 2008 | Page 17


SSL | Application Design Center Asia | V.Chen

Show false colors in CAD

Display the 3D rendering in a false colour rendering Easy to check the illuminance uniformity Freely scaleable value ranges and definable colour gradients

Event / Title | December 17, 2008 | Page 18


SSL | Application Design Center Asia | V.Chen

Agenda
Page Introduction and Install of DIALux Import IES files of OSRAM LEDs Quick Street Planning Wizard with DIALux Step by Step Design with OSRAM LEDs in DIALux 3 8 12 20

Event / Title | December 17, 2008 | Page 19


SSL | Application Design Center Asia | V.Chen

Step 1: Collecting road information


Street profile, width, N of lanes, coating
Information list before design: 1. Street location and photos 2. Width of street 3. N of lanes 4. Coating material
Decide the road classification and required Eav and Uo according to street lighting standards

5. Existing mounting height or pole distance?

Information needed for lighting simulation


Event / Title | December 17, 2008 | Page 20
SSL | Application Design Center Asia | V.Chen

Step 2: Edit street in DIALux

Arrangement of street component according to the road information.

Event / Title | December 17, 2008 | Page 21


SSL | Application Design Center Asia | V.Chen

Step 3: Decide which LED (color bin and brightness group)


CCT: from 5000K-6500K (LW, LUW) If need CCT from 4000K-5000K, can be mixed by LUW and LY.
Golden DRAGON with Oval Lens Golden DRAGON Plus

No need of secondary optical design

Need lens or reflector Higher brightness

Event / Title | December 17, 2008 | Page 22


SSL | Application Design Center Asia | V.Chen

Step 4: Change luminous flux

You can change the luminous flux and power here. Its related to how many LEDs in one lamp.

Event / Title | December 17, 2008 | Page 23


SSL | Application Design Center Asia | V.Chen

Step 5: luminaire arrangement


Normal methods of luminaire arrangement Single row Double row, opposing Double row, with offset
Uniformity Lighting Class

Single row
W 6m N 2

Double row, with offset


W 8m N 2

Double row, opposing


W 16m N 4

Road information

0.4~0.5

0.5~0.8

0.5~0.8

Rules of thumb

Luminaire arrangement will be decided based on street profile requirements


Figure

For LUW W5JM, Double row, opposing was recommended.

Event / Title | December 17, 2008 | Page 24


SSL | Application Design Center Asia | V.Chen

Step 6: Optimize arrangement parameters


Optimize arrangement parameters
(1) Mounting Height: 6m~10m (2) Overhang: 1m~2m (3) Boom Angle: 10~15 (4) Boom Length: 1m~3m (5) Pole Distance
Boom Angle Boom Length

Mounting Height

These parameter will be optimized according to street profile to achieve best performance: Eav and Uo.
Overhang

If a certain Uo was required, the most economic mounting height and pole distance could be optimized. Lower distance, longer pole distance could save energy and pole cost.

(5)Pole Distance

Lamp

Event / Title | December 17, 2008 | Page 25


SSL | Application Design Center Asia | V.Chen

Step 7: calculation and simulation


Eav(lx) 17 Emin(lx) 8.6 Emax(lx) 24 Uo 0.52 Emin/Emax 0.36 1 Change to double row, offset 2 Double row, opposing

Not so uniform, need to be improved

Optimized results

Eav(lx) 19

Emin(lx) 16

Emax(lx) 22

Uo 0.83

Emin/Emax 0.72

Event / Title | December 17, 2008 | Page 26


SSL | Application Design Center Asia | V.Chen

Step 8: Save the selected output as PDF file

Event / Title | December 17, 2008 | Page 27


SSL | Application Design Center Asia | V.Chen

Step 9: output design plan


Luminaire arrangement

Event / Title | December 17, 2008 | Page 28


SSL | Application Design Center Asia | V.Chen

Step 10: output simulation results


Isolines (E)

Table (E)

Eav(lx) 19

Emin(lx) 16

Emax(lx) 22

Uo 0.83

Emin/Emax 0.72

Main results

Event / Title | December 17, 2008 | Page 29


SSL | Application Design Center Asia | V.Chen

Thank you for your attention.

You might also like