You are on page 1of 10

BENTEL USER MANUAL GLOSSARY Alarm Memory Arm This is the history of the most recent violations that

occurred the last time when an alarm was triggered. To set the system into the ARMED mode. In this mode, a zone violation will activate an alarm condition. If the system is programmed accordingly, it will cause a reporting code to be sent to the central monitoring station. To deactivate zone. When the panel is ARMED, violation of a bypassed zone will be ignored. A short beep sound from the keypad to indicate a zone is violated. To deactivate the system. FIRE, PANIC and MEDICAL remain active while the system is disarmed. A zone with programmable delay time will allow user to exit the premises after arming the system and disarm by using the keypad after entering the armed premises. This zone is generally the last exit point and the first entry point of the building, i.e. the front door of a house. When the system is armed, any violation of an instant zone will immediately cause an alarm condition to be registered. A specific area of your premises guarded by sensors, which detect violations of that area.

Bypass

Chime Disarm Entry/Exit Zone

Instant Zone Zone

BENTEL USER MANUAL

UNDERSTAND YOUR KEYPAD INDICATORS

ARMED INDICATOR (Red) The indicator is illuminated when the system is armed

LCD Panel Show Date and Time / Zone Status

LCD Panel Show Partition Status Away ARM ( A ) Instant ARM ( I ) Saty Arm ( S ) DisArm ( D )

LCD Panel Show System Status,Example Teleserveice, Keypad Fault.

Buzzer

MEMORY INDICATOR (Red) The indicator will slow flash when the alarm is triggered

Up

SERVICE INDICATOR (Orange) The indicator is illuminated when the system is in trouble condition

B Mode / Left A Mode / Right

Down

ESC / Exit Program / Hold 5 sec to adjust buzzer volume Away Arm / Enable Command Function Disarm / Disable Command Function Enter / View System Troubleshoot

BENTEL USER MANUAL

SUMMARY OF OPERATION

Default User Code 1 [ 1234 ]


[User Code 1] + [On] [User Code 1] + [Off] [User Code 1] + [A] [User Code 1] + [B] [User Code 1] + [ [ ] [ ]+[C/D] ]+[ Clear Alarm Memory ]+ [ ]+[ View Logger ]+ [ ] ] ]+[ Zone Status ]+ [ OFF / ON ] +

Automatic Arm Automatic Disarm Away Arm Instant Arm Bypass Zone View Trouble Clear Alarm Memory View Alarm Memory Turn On/Off Keypad Buzzer Siren Test Program Date / Time Enter User Programming Mode Exit User Programming Mode

[User Code 1] + [ [User Code 1] + [

Hold down [ESC] for 2 seconds [User Code 1] + [ [User Code 1] + [ [User Code 1] + [ [ESC] ] + [Test Siren]+ [ ] ]

] + [Program Date/Time]+ [ ]

BENTEL USER MANUAL

USER PROGRAMMING SUMMARY TABLE [User Code 1] + [ [ESC] [Program Code ] + [Code 1] + [ New User Code ]+ [ ] [Program Code ] + [Code 2] + [ New User Code ]+ [ ] (DTMF Mode) ]

Enter User Programming Mode Exit User Programming Mode Program New or Change Existing Master Code * ( New User Code Could Be 4 digit or 6 digit ) Program New or Change Existing User Code 2 * ( For Phone Arm / Disarm Use )

Remark: All user codes must be unique from each other. Duplicate code will be rejected during user programming mode. [User Code 1] + [ Enter User Programming Mode [Program Tel. Num. ] + [Telephone Numb. 1 ] + [ User Telephone Number ] + [ ] [Program Tel. Num. ] + [Telephone Numb. 2 ] + [ User Telephone Number ] + [ ] [Program Tel. Num. ] + [Telephone Numb. 3 ] + [ User Telephone Number ] + [ ] [Program Tel. Num. ] + [Telephone Numb. 4 ] + [ User Telephone Number ] + [ ] [Program Tel. Num. ] + [Telephone Numb. 5 ] + [ User Telephone Number ] + [ ] ] Following below

Program Personal Telephone Number 1

Program Personal Telephone Number 2

Program Personal Telephone Number 3

Program Personal Telephone Number 4

Program Personal Telephone Number 5

ARMING THE SYSTEM There are various options for arming the system a. b. c. Away Arming Instant Arming Remote Control Away Arming

BENTEL USER MANUAL AWAY ARMING

[USER CODE 1] + [ON]


(Leave via ENTRY/EXIT Zone)

1. Ensure that all zone indicators are distinguished; if not, check that all protected premises are closed. 2. Enter a valid 4-6 digit [USER CODE 1]. If you enter any mistakes, press [ESC] key and reenter the code followed by [ON] key to confirm you command. 3. The ARMED indicator will illuminate and the keypad audible indicator will sound on and off for the duration of the EXIT delay. 4. Leave the premises only via the EXIT/ENTRY zone. 5. User will be given an ENTRY delay time to disarm the system when enter the protected premises via ENTRY/EXIT zone.

[USER CODE 1] + [A]


6. It is also possible to AWAY arm by [ USER CODE 1 ] + [A] INSTANT ARMING

[USER CODE 1] + [B]


1. This arming mode is ideal for NIGHT time arming with user still remains in the protected premises. 2. Ensure that all zone indicators are distinguished; if not, check that all protected premises are closed. 3. DO NOT open the ENTRY/EXIT zone. 4. Enter the [USER CODE 1] and following [B] 5. The ARMED indicator will illuminate. 6. There is no ENTRY delay in this arming mode. Any violation on the active zones will trigger the system instantly. REMOTE CONTROL ARMING 1. This arming mode is ideal for remote control unit. 2. The system will arm in AWAY arming mode. 3. The system will be armed with EXIT delay time which allows certain violated zones to be bypassed temporary. When the violated zones resume, the zone will be protected again. 4. Press the remote control button. 5. The system will be armed instantly. Leave the premises via ENTRY/EXIT zone. 6. The ARMED indicator will illuminate the keypad audible indicator will sound on and off for the duration of the EXIT delay. 7. If programmed to do so, the siren will sound briefly for this remote control arming. 8. User will be given an ENTRY delay time to DISARM the system when enter the protected premises via ENTRY/EXIT zone.

BENTEL USER MANUAL TELEPHONE REMOTE ARMING / DISARM 1. Your system can be remotely ARM from outside the house through any normal DTMF telephone or GSM hand phone. 2. Please refer to Telephone Control Program below.

DTMF Program Telephone On/Off


Enter user password 0001, press ENTER. Select (En./Dis.Ans.Func), press ENTER. Press the ON key to enable. Note: Once the Telephone Access Code has been recognized, enter the command (0002), same as [user code 2], there will be a beep sound. Then press:(i) Press 4 Will Beep Twice And Press 0 To Disarm. Then press # (ii) Press 4 Will Beep Twice And Press 2 To Disarm. Then press # (iii) Press 4 Will Beep Twice And Press 5 To Hear Status. Beep One Time Is Off,Beep twice is On B mode.Then press #,Last press * To End The Call. DISARMING THE SYSTEM There are various options for disarming the system: a. Keypad Disarming b. Remote Control Disarming c. Telephone Remote Disarm

KEYPAD DISARMING [USER CODE 1] + [OFF] 1. 2. To disarm the system, enter a valid 4-6 digit [USER CODE 1] followed by [OFF] key before expiry of the entry delay time. Enter the premises through a designated ENTRY/EXIT zone; entering via other zones will trigger an alarm instantly. 3. 4. 5. The ENTRY delay begins once the ENTRY zone is violated. The keypad audible indicator will sound for the duration of the ENTRY delay to indicate that a valid user code is required. If the ARMED indicator remains illuminated, an error has been made while entering the user code, please re-enter the user code 1 and press off button. 6. 7. Once the system is disarmed, the ARMED indicator will extinguish and the keypad audible indicator will stop. If no valid user code has been entered by the end of the ENTRY delay period, an ALARM condition will be registered and stored into the system MEMORY. 8. If the ENTRY delay is too short, have your installer to change the ENTRY delay period.

BENTEL USER MANUAL

BYPASS / UN-BYPASS ZONE

[User Code 1] + [

]+[ Zone Status ]+ [ OFF / ON ]+[

1. Enter the [User Code 1] and press enter. 2. Then using up / down ( Refer Keypad Indicators Page 2 ),and [ Zone Status ],press enter. 3. Select the zone that needs to be bypassed ( using A or B Buton ), then press [ ON ] to bypass,or press [ OFF ] to Unbypass. 4. Repeat step 3 to bypass other zones. 5. Press [ESC] key to exit the bypass mode. VIEW SYSTEM TROUBLE Press [ ] ] to view the

1. When the service indicator light on,that means got troubleshoot,press [ System fault on LCD Screen. 2. Press [ESC] key to exit. The Mains power supply to the Control Panel has failed.If it is not a general Black-Out A BPI device has failed to respond ( Mising ) - Keypad Fault Blown fuse

Mains Fault BPI Fault Fuse Fault Battery Fault

The Control panel battery is not recharging properly or is faulty The Battery of a Wireless Zone Device has not been charged properly or it is down completely or fault Contact your Installer.The Zone concerned will be indicated after the Z (E.g Battery Fault Z03) Telephone Line trouble This Trouble condition will be present until a User Code is programmed For Wireless systems, the Wireless Receiver is not functioning properly Wireless interference has been detected One or more of the Wireless Zone Devices is not responding Contact your Installer.The Zone concerned will be indicated after Z ( E.g Missing Z03

Battery Fault Z.. Tel. Line Fault Default Codes WLS Fault Wireless Jam

Missing Device Z..

BENTEL USER MANUAL

VIEW ALARM MEMORY [User Code 1] + [ ]+[ View Logger ]+ [ ]

1. The system alarm memory will be store up to 256 events circular ( 128 on Kyo 4/8/8G Models). An alarm condition will cause the MEMORY indicator to slow flash. 2. The MEMORY indicator will extinguish once the user clear the alarm memory. 3. Press [ESC] key to exit. USER PROGRAMMING MODE CHANGE USER CODE 1 [User Code 1] + [ 1. Ensure that the system is not ARMED. 2. Press [User Code 1] and press [ ] into USER Menu mode. ]

3. Using up / down go to [ Program Code ],then press enter. 4. Thats LCD will display code 1,so you just key in your new 4-6 digit user code,and press enter. 5. Press [ ESC ] to exit. EXIT USER PROGRAMMING MODE [ESC] 1. Once all setting is programmed, press [ESC] key to exit. PROGRAM SYSTEM TIMER [User Code 1] + [ ] + [Program Date/Time]+ [ ]

1. Enter [Program Date / Time] for system timer setting. 2. Change the system time using (A,B,C,D) key to adjust the time. 3. Enter [ ] key to confirm the time. 4. To exit user programming mode, press [ESC] key.

BENTEL USER MANUAL

PROGRAM PERSONAL TELEPHONE NUMBER 1 [User Code 1] + [ Program Tel. Num. ] + [Telephone Numb. 1 ] + [01X-XXXXXXX ] + [ 1. Enter the [User Code 1] ,and press enter. [ ] ] ]

2. Using Up / Down go to [ Program Tel. Num. ] and press enter again. [ 3. Choice which number you want to change. (E.g [Telephone Numb 1], then press enter. [ ] ] 4. Key in your phone number direct.Press enter. [ 5. Enter [ESC] key to exit. TO ERASE PERSONAL TELEPHONE NUMBER 1

[User Code 1] + [ Program Tel. Num. ] + [Telephone Numb. 1 ] + [OFF] + [OFF] + [OFF] +[ ] 1. Enter the [User Code 1] ,and press enter. [ ] ]

2. Using Up / Down go to [ Program Tel. Num. ] and press enter again. [ 3. Choice which number you want to change. (E.g [Telephone Numb 1], then press enter. [ 5. Enter [ESC] key to exit. PROGRAM PERSONAL TELEPHONE NUMBER 2 (DTMF Mode) ]

4. Then press the [OFF] button on keypad 3 times.And press enter.

[User Code 1] + [ Program Tel. Num. ] + [Telephone Numb. 2 ] + [01X-XXXXXXX ] + [ 1. Enter the [User Code 1] ,and press enter. [ ] ]

2. Using Up / Down go to [ Program Tel. Num. ] and press enter again. [ 3. Choice which number you want to change. (E.g [Telephone Numb 2], then press enter. [ ] ] 4. Key in your phone number direct.Press enter. [ 5. Enter [ESC] key to exit.

TO ERASE PERSONAL TELEPHONE NUMBER 2 [User Code 1] + [ Program Tel. Num. ] + [Telephone Numb. 2 ] + [OFF] + [OFF] + [OFF] +[ ] 1. Enter the [User Code 1] ,and press enter. [ ] ]

2. Using Up / Down go to [ Program Tel. Num. ] and press enter again. [ 3. Choice which number you want to change. (E.g [Telephone Numb 2], then press enter. [ ] 4. Then press the [OFF] button on keypad 3 times.And press enter. 5. Enter [ESC] key to exit.

BENTEL USER MANUAL

SYSTEM INFORMATION SECURITY ZONE INFORMATION Zone Zone Type No. e.g. Entry/Exit Delay

Location e.g. Main door

SYSTEM SETTING INFORMATION Timer Entry Time Exit Time Siren Cut-Off Time Telephone Reporting Telephone Number 1 Telephone Number 2 Dialing Attempt Sevicing Installer company Contact person Contact number Installation Date : : : : ______ / ______ / ______ : _____________________________________________ : _____________________________________________ : _____________________________ times : ______________________ seconds ( Default 30 Sec ) : ______________________ seconds ( Default 30 Sec ) : ______________________ minutes ( Default 5 Min )