Professional Documents
Culture Documents
4. Characteristics
Characteristics shall be complied with Table 1.
1|Page
Table 1
Characteristics
Item
Test method
construction
5 in JIS C 3005
Conductor resistance
6 in JIS C 3005
Withstand voltage
Insulation resistance
Surface leakage
resistance
Tensile
Unaged
strength
Elongation
100%
modulus
After aging Tensile
strength
Elongation
After
immersion
in hot oil
Tensile
strength
Elongation
Flame retardance
18 in JIS C 3005
19 in JIS C 3005
Aging Temp: 1502OC
Aging Time : 96h
20 in JIS C 3005
Temp. of oil immersion: 70
2OC
28.2(1) in JIS C 3005
Table 2
A
0
1
2
3
4
5
6
7
8
9
0.10
0.12
0.13
0.14
0.16
0.18
0.20
0.22
0.25
0.28
10
11
12
13
14
15
16
17
18
19
0.32
0.36
0.40
0.45
0.51
0.57
0.63
0.70
0.79
0.90
20
21
22
23
24
25
26
27
28
29
1.00
1.20
1.30
1.40
1.60
1.80
2.00
2.20
2.50
2.80
30
31
32
33
34
35
36
37
38
39
3.20
3.60
4.00
4.50
5.10
5.70
6.30
7.00
7.90
9.00
2|Page
Thick.
Of
Insulation
Overall Diameter
Tolerance
of
Overall
Diameter
Conductor
Resistance
O
(20 C)
Test
Voltage
Insulation
Resistance
O
(20 C)
Surface
Leakage
Resistance
Approx.
Mass
Reference
standard
length
(mm)
(mm)
(mm)
(mm)
(mm)
(/km)
(V)
(M km)
(M)
(kg/km)
(m)
125
100
80
60
19/42/0.45
19/34/0.45
19/27/0.45
19/20/0.45
16.9
15.2
13.5
11.6
2.0
2.0
1.5
1.5
21.1
19.4
16.7
14.8
1.1
0.9
0.9
0.8
0.149
0.183
0.230
0.311
3000
3000
2500
2500
20
20
20
20
70
80
90
100
1330
1070
835
645
300
300
300
300
Drum
Drum
Drum
Drum
50
38
22
14
19/16/0.45
7/34/0.45
7/20/0/45
88/0.45
10.4
9.1
7.0
4.9
1.5
1.2
1.2
1.0
13.5
11.7
9.6
7.0
0.8
0.7
0.7
0.6
0.389
0.496
0.844
1.32
2500
2200
2200
2200
20
20
25
30
100
100
100
200
510
395
245
150
300
100
100
200
Drum
Coil
Coil
Coil
8
5.5
3.5
2
50/0.45
35/0.45
45/0.32
37/0.45
50/0.18
3.7
3.1
2.5
1.8
1.0
1.0
1.0
1.0
5.8
5.2
4.6
3.9
0.6
0.6
0.6
0.5
2.32
3.31
5.38
9.91
2200
2200
2200
2200
35
40
45
60
200
200
300
300
90
65
45
30
200
400
400
400
Coil
Coil
Coil
Coil
1.5
1.0
3.6
0.5
15.5
2200
70
300
20
400
Coil
Nominal
Sectional
Area
Conductor
Construction
No./Dia
Of
Wire
(mm )
1.25
Packing
3|Page
(mm )
Conductor
Constructio
n
No./Dia
Of
Wire
(mm)
250
200
150
125
37/42/0.45
37/34/0.45
27/34/0.45
19/42/0.45
23.6
21.2
18.7
16.9
3.0
3.0
2.5
2.5
29.8
27.4
23.8
22.1
1.2
1.1
1.0
1.0
0.0760
0.0939
0.129
0.149
5400
5400
5400
5400
20
20
20
20
50
50
60
60
2570
2110
1540
1420
300
300
300
300
Drum
Drum
Drum
Drum
100
80
60
50
19/34/0.45
19/27/0.45
19/20/0.45
19/16/0.45
15.2
13.5
11.6
10.4
2.5
2.5
2.5
2.5
20.4
18.7
16.8
15.6
1.0
0.9
0.8
0.8
0.183
0.230
0.311
0.389
5400
5400
5400
5400
25
25
30
30
70
80
90
90
1120
905
710
575
300
300
300
300
Drum
Drum
Drum
Drum
38
22
14
8
7/34/0.45
7/20/0.45
88/0.45
50/0.45
9.1
7.0
4.9
3.7
2.0
2.0
2.0
2.0
13.3
11.2
9.0
7.8
0.8
0.7
0.7
0.6
0.496
0.844
1.32
2.32
5400
5400
5400
5400
30
45
50
60
100
100
100
100
435
275
180
115
100
100
200
200
Coil
Coil
Coil
Coil
5.5
3.5
2
35/0.45
45/0.32
37/0.26
3.1
2.5
1.8
2.0
2.0
2.0
7.2
6.6
5.9
0.6
0.6
0.6
3.31
5.38
9.91
5400
5400
5400
65
75
95
200
200
200
90
70
60
200
400
400
Coil
Coil
Coil
Nominal
Sectional
Area
2
Reference
standar Packing
d
length
Diameter
of
Conductor
Thick.
Of
Insulation
Overall Diameter
Tolerance
of
Overall
Diameter
Conductor
Resistance
O
(20 C)
Test
Voltage
Insulation
Resistance
O
(20 C)
Surface
Leakage
Resistance
Approx.
Mass
(mm)
(mm)
(mm)
(mm)
(/km)
(V)
(M km)
(M)
(kg/km)
(m)
4|Page
Conductor
Construction
No./Dia
Of
Wire
Diameter
of
Conductor
Thick.
Of
Insulation
Overall Diameter
Tolerance
of
Overall
Diameter
Conductor
Resistance
(20OC)
Test
Voltage
Insulation
Resistance
(20OC)
Surface
Leakage
Resistance
Approx.
Mass
(mm )
(mm)
(mm)
(mm)
(mm)
(mm)
(/km)
(V)
(M km)
(M)
(kg/km)
(m)
250
200
150
125
61/77/0.26
37/102/0.26
37/51/0.26
47/64/0.26
22.6
20.2
17.5
16.0
3.0
3.0
2.5
2.5
28.8
26.4
22.7
21.2
1.2
1.1
1.0
0.9
0.0771
0.0950
0.128
0.155
5400
5400
5400
5400
20
20
20
20
50
50
60
70
2590
2110
1570
1380
300
300
300
300
Drum
Drum
Drum
Drum
100
80
60
50
37/51/0.26
19/79/0.26
19/60/0.26
19/50/0.26
14.4
12.7
11.2
10.2
2.5
2.5
2.5
2.5
19.6
17.9
16.4
15.4
0.9
0.9
0.8
0.8
0.190
0.239
0.328
0.377
5400
5400
5400
5400
25
25
30
30
70
80
90
90
1090
885
720
590
300
300
300
300
Drum
Drum
Drum
Drum
38
22
14
8
19/38/0.26
19/22/0.26
7/38/0.26
7/22/0.26
9.2
7.0
5.5
4.2
2.0
2.0
2.0
2.0
13.4
11.2
9.7
8.4
0.8
0.7
0.7
0.7
0.518
0.894
1.41
2.43
5400
5400
5400
5400
30
45
50
60
100
100
100
100
450
285
195
130
100
100
200
200
Coil
Coil
Coil
Coil
5.5
3.5
7/15/0.26
7/10/0.26
3.5
2.8
2.0
2.0
7.7
7.0
0.6
0.6
3.56
5.34
5400
5400
65
65
200
200
100
75
200
400
Coil
Coil
Nominal
Sectional
Area
2
Reference
standar Packing
d
length
5|Page
Separator
Insulation
Cross Section of Wire (WL2)
Conduktor
Separator
Insulation
Cross Section of Wire (WML2)
Conduktor
Separator
Insulation
6|Page
GSC
WIRE FOR ELECTRIC APPARATUS
Current Carrying Capacity
Conductor Size (mm2)
Ampere
250
200
150
125
100
80
60
50
38
30
22
14
8
5.5
3.5
2.0
1.25
0.75
0.5
850
717
604
526
455
393
332
290
247
212
175
134
93
74
56
41
29
22
18
(Note)
- Ambient Temperature: 40oC
- Conductor temperature: 105oC
- Details are shown in GSC Cat. No. PKV-401.
7|Page