Current Transformers
Safe, Reliable High-Voltage Current Transformers That Never Need Maintenance
Current transformers are used in electrical grids for measurement and protective applications to provide signals to equipment such as meters and protective relays by stepping down the current of that system to measurable values. Their role in electrical systems is of primary importance because the data sent by current transformers represent the heartbeat of the entire system. RHM Internationals proprietary dry type Current Transformers are unique as they provide a rugged, reliable option for high voltage metering and protection operations up to 550 kV. Our high quality Current Transformers are based on a unique U-shaped bushing design for the primary winding. The bushing is a very fine capacitance graded insulator. In a new approach to dry designs, our advanced proprietary HV DryShieldTM composite insulation system uses reliable materials like PTFE (Polytetrafluoroethylene) and silicon rubber to provide a low stress, uniform field distribution between the conductor and the outside structure. The primary and secondary windings are independently sealed resulting in a totally weather resistant design. Oil or gas is not required for insulation. Therefore, our environmentally friendly Current Transformers completely eliminate the risk of explosion and toxic leaks. Considering the difficulty for our customers to schedule circuit outages for routine upgrades and maintenance, the high cost of maintenance, and environmental issues, RHM Internationals Current Transformers provide exceptionally low cost of ownership and offer you peace of mind as they are truly maintenance free. Customer benefits:
Dielectric Dissipation Factor (Tan) Flashover Risk Manufacture Time

LRGBJZHD 110 kV

LRGBJ110 kV

Totally safe no risk of explosion Totally maintenance free exceptional low cost of ownership Environmentally friendly no risk of toxic leak and recyclable insulation materials 2 to 3 times lighter than conventional oil or gas based products Mature and Innovative with unmatched quality records not a single failure in 20 000 HV DryShieldTM equipped products in the field A new approach to dry design without the limitations of conventional dry Current Transformers All products are developed and manufactured in an ISO 9001 certified plant and compliant to IEC and IEEE international standards.

Partial Discharge

Maintenance Required

Actual Failure Rate


Oil SF6 RHM

Component Weight

Comparison of conventional current transformer technologies with RHM Internationals

A TR Electric Partner
RHM International LLC 81 Glen Road, Brookline, MA 02445 USA Tel/Fax: +1 617 608 0274 info@rhmintl.com www.rhmintl.com

Main Characteristics 1.Performance Highest voltage for equipment: 40.5-550 kV Rated primary current: Rated secondary current: Rated output: Rated frequency: 50, 60 Hz 5-5000 A (up to 8000 A under specific conditions please contact us) 5 A, 1 A 10-50 VA 0.2S, 0.2, 0.5S and 0.5 class

Accuracy class for measuring current transformer: Instrument security factor: 5, 10

Accuracy limit factor for protective current transformer: 5,10, 15, 20, 30, 40 Secondary cores: 1-8

All products comply with IEC-44-1-1996 Current Transformers and IEEE C57.13 standards Protective class current transformers comply with IEC-44-6: 1992 Requirements for Protective Current Transformers for Transient Performance 2. Environmental Condition Places of operation: Environmental temperature: Altitude: Pollution level: Indoors and outdoors -45 [-49F] / +45 [113F] c c <1000m above sea level (when higher than 1000m, specific design available. Please contact us) fully compliant to Class IV environments (IEC category very heavy pollution level)

3. Type tests and special tests include: Measurement of capacitance and Dielectric Dissipation under Um/3 and 10kV, the Dielectric dissipation factor (tan) is less than 0.004 Short-time current tests: Thermal short-time current (Ith): Rated dynamic current (Idyn): Temperature-rise test: Mechanical tests (see table 2) Determination of errors 50 kA, 3s 125 kA (peak value) 75 K 40.5 72.5 126 252 550
Highest voltage for equipment Um kV (r.m.s.) Rated power Rated frequency switching withstand impulse voltage withstand 1 min50/60 Hz. voltage kV kV (r.m.s.) (peak) Rated lightning impulse withstand voltage kV (peak) Rated chopped lightening impulse withstand voltage kV Partial discharge pC

95* 140* 230* 460* 680

1175*

185 325 550 1050 1550

632 1207 1783

<5 = <5 = <5 = <5 = < 10 =

Insulation and thermal stability test (36h according to standard but tested 72h for 550kV)

* a wet test is added for outdoor use

4. Routine tests: Before leaving the factory the following routine tests are carried out: on primary winding: Power-frequency withstand test Power-frequency withstand test between sections of primary Partial discharge measurement Capacitance and dielectric dissipation factor measurement Verification of terminal markings 5.Maintenance: Maintenance is not needed on secondary windings: Power-frequency withstand test Power-frequency withstand test between sections of secondary windings Inter-turn over-voltage test Determination of errors Highest voltage Um (kV) 5.72.5 126 252 550 Table 2 Static forces (N) 1250 2000 4000 4000

Maintenance-free

Accuracy class for protective current transformer:

5P, 10P and TPY (TPS, TPX and TPZ on demand)

Standard LRGBJ CTs


Model & Specification
LRGBJ - 40.5 / 600 LRGBJ - 40.5 / 1000 LRGBJ - 40.5 / 1200 LRGBJ - 40.5 / 1600 LRGBJ - 40.5 / 2500 LRGBJ - 72.5 / 600 LRGBJ - 72.5 / 1000 LRGBJ - 72.5 / 1200 LRGBJ - 126 / 600 LRGBJ - 126 / 1000 LRGBJ - 126 / 1200 LRGBJ - 126 / 1600 LRGBJ - 126 / 2500 LRGBJ - 252 / 600 LRGBJ - 252 / 1000 LRGBJ - 252 / 1200 LRGBJ - 252 / 1600 LRGBJ - 252 / 2500 LRGBJ - 550 / 2500 TPY

Highest voltage for equipment (kV)


40.5 40.5 40.5 40.5 40.5 72.5 72.5 72.5 126 126 126 126 126 252 252 252 252 252 550

Rated current (A)


100~600 800~ 1000 1200 1600 2000~2500 100~600 800~ 1000 1200 100~600 800~ 1000 1200 1600 2000~2500 100~600 800~ 1000 1200 1600 2000~2500 2500 L 1015 1015 1015 1030 1060 1550 1550 1550 1785 1785 1785 1800 1830 2670 2670 2670 2710 2740 5900 L1 80 80 80 100 120 80 80 80 80 80 80 100 120 80 80 80 100 120 L2 20 20 20 25 30 20 20 20 20 20 20 25 30 20 20 20 25 30 L3 40 40 40 50 60 40 40 40 40 40 40 50 60 40 40 40 50 60 see figure

Dimensions (mm)
L4 400 400 400 400 400 580 580 580 580 580 580 580 580 860 860 860 860 860 L5 360 360 360 360 360 200 200 200 200 200 200 200 200 350 350 350 350 350 L6 350 350 350 350 551 551 551 551 551 551 551 551 551 715 715 715 715 715 1260 L7 320 320 320 320 320 400 400 400 400 400 400 400 400 500 500 500 500 500 700 a b 15 14 15 14 15 14 15 14 15 18 15 14 15 14 15 14 15 14 15 14 15 14 15 14 19 18 19 14 19 14 19 14 19 14 19 18 see figure t 12 12 14 14 14 12 12 14 12 12 14 14 14 12 12 14 14 14

Creepage distance (mm)


1015 1015 1015 1015 1015 1925 1925 1925 3200 3200 3200 3200 3200 6300 6300 6300 6300 6300 13750

Weight (kg/lb)

90/198 90/198 90/198 90/198 90/198 200/441 200/441 200/441 240/529 240/529 240/529 240/529 240/529 440/970 440/970 440/970 440/970 440/970 3000/6614

All dimensions are indicative of typical designs - actual dimensions are confirmed with orders. Special sizes available upon request.

LRGBJ CT
A L7

LRGBJ 550/2500 TPY


L7

20 40

L +/- 30

40 125

22.5

6-14

525

L4 L1 L2 L3 +/- 0.5 t
L3 +/- 0.5

L6 +/- 10

L5 4-a

590015

L1

4-b

740 1100 1250 1520

1260

d20

4-50

8-26 700 820 855

High Current CT
Model & Specification
LRGBJ - ZHD - 72.5 / 4000 LRGBJ - ZHD - 72.5 / 6000 LRGBJ - ZHD - 126 / 4000 LRGBJ - ZHD - 126 / 6000 LRGBJ - ZHD - 252 / 4000 LRGBJ - ZHD - 252 / 6000

Highest voltage for equipment (kV)


72.5 72.5 126 126 252 252

Rated current (A)


2500 ~ 4000 5000 ~ 6000 2500 ~ 4000 5000 ~ 8000 2500 ~ 4000 5000 ~ 6000 L 1650 1650 1880 1880 2950 2950 L1 160 125 160 125 160 125 L2 80 180 80 180 80 180 L3 50 60 50 60 50 60

Dimensions (mm)
L4 30 32.5 30 32.5 30 32.5 L5 580 580 580 580 860 860 L6 200 200 200 200 350 350 L7 531 531 531 531 715 715 L8 400 400 400 400 500 500 a 15 15 15 15 19 19 D 18 18 18 18 18 18

Creepage distance (mm)


1925 1925 3200 3200 6300 6300

Weight (kg/lb)

250/551 250/551 290/639 290/639 490/1080 490/1080

All dimensions are indicative of typical designs - actual dimensions are confirmed with orders. Special sizes available upon request.

High Current LRGBJ ZHD Inquiry check list

When placing an order, customers specification needs to include: Highest voltage Um Rated current Rated frequency Rated transformation ratio Number of secondary windings Rated output (20~50VA) Accuracy class: 0.2s, 0.2, 0.5s, 0.5or 5P, 10P, TPY Accuracy limit factor (5\10\15\20\25\30) Instrument security factor: 5,10 If users have specific requirements, custom designs can be jointly defined.

RHM International LLC 81 Glen Road Brookline, MA 02445 USA Tel/Fax: +1 617 608 0274 info@rhmintl.com www.rhmintl.com