You are on page 1of 26

Industrial lighting

Eurobay 82

Compak 84

Versabeam 85

Filterglow 86

Lowmount 88 OMBS Omnibeam 97

Conserva 90 Hiper 99

OMG Omniglow 92 VSG Versaglow 101

GHPB 95 GGD Garage Gard 103

GE Consumer & Industrial 81 GE Consumer & Industrial 81


Lighting Lighting
EUROBAY

Eurobay luminaires for interior application feature a low-profile design and


can be equipped with high pressure mercury vapour, sodium or metal halide
lamps of up to 400 W. Version “CD” is also available, where an additional
halogen lamp will light up and operate as long as the main discharge lamp
can reach its rated power at switch on.Ideal for industrial and commercial
environments, with medium-high installation heights.
Main body: die-cast aluminium body with slide-adjustable steel suspension
hook for
balancing the fitting.
Wiring box: connected to the main body and made from fibreglass-reinforced
engineering polymer thermoplastic. The wiring box contains the lamp
operating
components, which are mounted on a removable galvanised steel plate.
Accessed by way of a hinged door fitted with a neoprene gasket and secured
by four stainless steel screws.
Cable inlet: The wiring box is fitted with a nylon PG13.5 cable gland for cable
diameters of 9 to 12.5 mm.
Reflector: 99.85% anodised, mirror-finish aluminium reflector ideal for clear
bulbs.
The reflector is fitted with a silicone gasket and secured to the main body by
four screws. Designed to fit a wire guard and protective glass.
Lampholder: plastic E40 version. The lampholder can be adjusted in 4
different positions to optimise light distribution in relation to the type of lamp
used and the installation height.

ACCESSORIES
Protective glass EBV: tempered glass fixed to the reflector by three stainless
steel clips; supplied with safety chain attached to the main body.
Wire guard EBG: galvanised steel wire guard used in conjunction with the
protective glass, and supplied complete with safety chain.
Diffuser EBD: UV-stabilized, self-extinguishing V0 polycarbonate, fixed by 6
clips to the body.

GE Consumer & Industrial 82


Lighting
EUROBAY
Weight Pack Qty. Product
Type Lamp (kg) Box Pallet Code

200 Body complete with lamp.


EUROBAY Class: With protective front glass IP 65
230V 50Hz For open luminaires or

CEI 34.21 / EN 60598-1, IEC 598 luminaires with wire guard IP 23


EB 250 H H250/40 5,2 1 30 90346
EB 400 H H400/40 6,3 1 30 90344
EB 250 M ARC250/T/VBU/960/40 5,4 1 30 90343
EB 400 M KRC400/T/VBU/960/40 6,6 1 30 90342
EB 150 S LU150/100/40 4,2 130 90338
EB 250 S LU250/T/40 5,4 1 30 90337
EB 400 S LU400/T/40 7,0 1 30 90339

Weight Pack Qty. Product


Type Lamp (kg) Box Pallet Code

Body complete with principal lamp and an auxiliary 150W halogen lamp.
EUROBAY Class: With protective front glass IP 65
230V 50Hz For open luminaires or

CEI 34.21 / EN 60598-1, IEC 598 luminaires with wire guard IP 23


EB 250 H CD H250/40 5,4 1 30 90335
EB 400 H CD H400/40 6,5 1 30 90334
EB 250 M CD ARC250/T/VBU/960/40 5,6 1 30 90333
EB 400 M CD KRC400/T/VBU/960/40 6,8 1 30 90332
EB 150 S CD LU150/100/40 4,4 1 30 90331
EB 250 S CD LU250/T/40 5,6 1 30 90330
EB 400 S CD LU400/T/40 7,2 1 30 90329

Weight Pack Qty. Product


Type Lamp (kg) Box Pallet Code

Reflector
EUROBAY
EBR Reflector 1,20 4 32 33686
EBRD Reflector 0,85 4 16 92305

Accessories
EUROBAY
EBV Protective glass for EBR 2,00 4 112 33687
EBG Wire guard for EBR 0,40 4 112 33688
EBG Diffusor for EBRD 1,15 4 40 92304

GE Consumer & Industrial 83


Lighting
COMPAK

Indoor ceiling luminaires for clear bulb high pressure sodium and metal halide
lamps of up to 400W.
Body: cold-pressed bonderised sheet steel with white stoved polyester powder
paint finish.
The two side clamps for mounting on the ceiling are fixed on top. Power supply
unit with power factor correction, terminal block and cable clamp are mounted
on a removable
galvanised sheet steel located in a compartment. Cover on power supply
compartment fixed by two screws with knurled nuts.
One side hinged, easily removable white sheet steel frame with expanding
rubber gasket holds the tempered front glass (enclosed as a standard
accessory) protecting the optics. The other side of the frame is fixed to the body
by two M5x60 stainless steel screws for protection against fall.
Reflector: anodised and polished 99.85% pure hammered aluminium.
Lampholder: porcelain E40.
Cable entry: through grommet on the top of the luminaire.

Tot. Absorbed Weight Pack Product


340 Type Lamp Power (W) (kg) Qty. Code

COMPAK Class: I IP 42
30 200
600 230V 50Hz CEI 34.21 / EN 60598-1
CPC 250 LU250/T/40 275 13,3 1 30939
ARC250/T/H/960/E40
CPC 400 KRC400/T/H/960/E40 440 13,5 1 30941
CPS 400 LU400/T/40 436 14,9 1 30943
HPF = with power factor correction - Without lamp.

Pack Product
Type Description Qty. Code
Accessories

CPG Ø 3mm electric welded galvanised 5 31340


steel wire guard.
Dimensions: 39mm x 36mm.
Fixed through 4 threaded bores in front
frame by 4 screws (enclosed).

CPL Aluminium louvre with white paint finish. 1 31341


Dimensions of the grid: 50mm x 50mm.
Fitted in the frame, it is mounted by 4
screws fixing the protective glass.

Pack Product
Type Description Qty. Code
Spare parts

CPV 4mm thick tempered glass sheet 5 31342


(enclosed) fixed by 2 screws to the
front frame.
PTL E40 Lampholder 1 31372

GE Consumer & Industrial 84


Lighting
VERSABEAM
Indoor luminaires in new “bowl shaped” form for 250W and 400W clear bulb
high-pressure sodium and metal halide lamps. Especially useful for
installation of 5-11 m height, in complicated assembly and machinery
layouts and on sites with obstructions.
Body: die-cast aluminium ballast housing with electrocoat grey paint finish.
It contains 230V 50Hz power supply unit with power factor correction,
prepared for quick electronic and mechanic connection to the reflector
containing also the lampholder.
Threaded hub on top allows quick and safe installation with matching hook
(not included). Safety chain provisions available.
Optical assembly: basically a die-cast UV stabilised metacrylate refractor
with prismatic finish for optimum light output. Hinged to a circular high
purity aluminium reflector with ALGLAS coating (see page 144) and fastened
to it through gasket by 4 stainless steel latches preventing fall. The l
ampholder fastened to the reflector, surrounded by a small prismatic
parabolic refractor for the maximum optical performances. On the outside,
the reflector is provided with positioning element for the quick connecting to
the body. Built-in carbon filter guarantees the optics to remain clean for a
long time.
Safety chain against fall is also available.
Lampholder: E40 porcelain.
Power supply: 230V 50Hz, with power factor correction, cos j ≥ 0,9.
Maximum ambient temperature: 55°C.
Installation height: 5 -11 m.
Installation: with die-cast aluminium hook and safety fixing bolts.

Tot. Absorbed Weight Pack Product


229 Type Lamp Power (W) (kg) Qty. Code

IP 52 gearbox Class: I
230V 50Hz IEC - CEI
FGS25S LU250/T/40 275 8,80 1 30771
FGS40S LU400/T/40 436 9,90 1 30776
FGS25MBF MVR250/U/40 275 8,80 1 30788
787 FGS40MBF MVR400/U/40 430 8,80 1 30825
HPF = with power factor correction - Without lamp.

Tot. Absorbed Weight Pack Product


Type Lamp Power (W) (kg) Qty. Code

610
IP 54 reflector - diffuser
VBDGEA LU250/400/T/40 610 6,30 1 31337
VBDVEA MVR250/U/40 610 6,30 1 31338
VBDAEA MVR400/U/40 610 6,30 1 31339
Warning: VERSABEAM is not suitable for high-pressure mercury vapour lamps.
13

Weight Pack Product


117
Type Description (kg) Qty. Code
105

Suspension hook
HOOKM With seal IP52 0,15 1 31232
HOOKMG With seal IP54 0,16 1 31269
SFC3-B SFC-O

Accessories

Safety chain
SFC3-B For the body, of. 0,9 m length 0,25 1 31273
SFC-O For the reflector 0,10 1 31277

GE Consumer & Industrial 85


Lighting
FILTERGLOW

Indoor luminaires for max. 1000W clear bulb high-pressure sodium and metal
halide lamps.
Gearbox: die-cast aluminium ballast housing with electrocoat grey paint finish.
It contains 230V 50Hz power supply unit with power factor correction,
prepared for quick electronic and mechanic connection to the reflector
containing also the lampholder.
Threaded hub on the top allows quick and safe installation with matching hook
(not included).
Safety chain provisions.
Reflector: pure aluminium, internally “ALGLAS” covered, clip-fit fastened to the
gearbox; tempered cover glass with rubber gasket, suspension hinge and three
safety stainless steel latches for fixing to the reflector. It can be equipped with
safety chain.
The E7 version of 448 mm diameter is suitable for discharge lamps of max.
400W; the E2 version of 587 mm diameter is suitable for discharge lamp of
1000W and can be attached either to the FGL or FGS type gearboxes. Carbon
filter in the upper part preserves the optics from gaseous or vaporous
contamination.
Lampholder: E40 from porcelain, adjustable in 11 positions according to the
type of lamp used and the desired optical parameters.
Power supply: 230V 50Hz, with power factor correction, cos j ≥ 0,9.
Maximum working ambient temperature: 55°C.
Wire guard: available on special request, can be attached to the protective
glass and is available in the WGNH-17E and WGNH-22E versions for the E7
and E2 reflectors, respectively.
It is a concentric ring mesh in dia 3 mm zinc-plated steel wire.
Installation height: ≥ 6 m.
Installation: with die-cast aluminium hook and safety fixing bolts.

GE Consumer & Industrial 86


Lighting
FILTERGLOW

Tot. Absorbed Weight Pack Product


Type Lamp Power (W) (kg) Qty. Code

IP 52 gearbox Class: I
230V 50Hz IEC - CEI
FGS25S LU250/T/40 275 8,80 1 30771
FGS40S LU400/T/40 436 9,90 1 30776
229 267 FGS25MBF MVR250/U/40 275 8,80 1 30788
FGS40MBF MVR400/U/40 430 8,80 1 30825
FGL01S LU1000/110/T/40 1050 18,20 1 30823
FGL01MBF MVR1000/U/40 1050 17,50 1 32254
HPF = with power factor correction - Without lamp.

756
IP 54 gearbox Class: I
762
230V 50Hz IEC - CEI
FGS25SW LU250/T/40 275 8,80 1 30772
FGS40SW LU400/T/40 436 9,90 1 30785
FGS25MBFW MVR250/U/40 275 8,80 1 30800
FGS40MBFW MVR400/U/40 430 8,80 1 30832
FGL01SW LU1000/110/T/40 1050 18,20 1 30816
448 587
FGS with E7 reflector FGL FGL01MBFW MVR1000/U/40 1050 17,50 1 32253
FGS con riflettore E7 FGL conwith E2 E2
riflettore reflector
HPF = with power factor correction - Without lamp.

Diameter Weight Pack Product


Type Lamp (mm) (kg) Qty. Code

IP 54 reflector (complete with tempered cover glass)


FG05E7 LU250/T/40 448 2,40 1 31305
MVR400/U/40
FG03E7 LU400/T/40 448 2,40 1 31307
FG01E7 MVR250/U/40 448 2,40 1 31309
FG07E2 LU1000/110/T/40 587 3,20 1 31322
MVR 1000/U/40

Weight Pack Product


Type Description (kg) Qty. Code

Suspension hook
HOOKM With seal IP52 0,15 1 31232
HOOKMG With seal IP54 0,16 1 31269
13

Accessories
117
105 Safety chain
SFC3-B For the body, 0,9 m length 0,25 1 31273
SFC-O For the reflector 0,10 1 31277

SFC3-B SFC-O Diameter Weight Pack Product


Type Lamp (mm) (kg) Qty. Code
Accessories
Wire guard concentric rings of Ø 3mm zinc-plated steel wire..
It can be installed on the protective glass.

Wire guard
WGNH-17E 432 0,34 1 31293
WGNH-22E 559 0,45 1 31290

GE Consumer & Industrial 87


Lighting
LOWMOUNT 400

Indoor luminaires for 250W and 400W clear bulb high-pressure sodium and
metal halide lamps. Very versatile for low mounting in either commercial or
industrial applications with installation height of 3-8 m.
Gearbox: die-cast aluminium ballast housing with electrocoat grey paint finish.
It contains 230V 50Hz power supply unit with power factor correction,
prepared for quick electronic and mechanic connection to the reflector
containing also the lampholder.
Threaded hub on the top allows quick and safe installation with matching hook
(not included).
Safety chain provisions available.
Reflector: anodised polished “ALZAK” aluminium covered from the bottom by
die-cast UV-stabilised polycarbonate low luminance prismatic refractor.
Carbon filter in the body preserves the optics from the external contaminating
agents.
The hinged reflector is fastened to the body through gasket by 2 strong
stainless steel latches protecting the lamp against fall.
Safety chain provisions available.
Lampholder: E40 porcelain.
Power supply: 230V 50Hz, with power factor correction, cos j ≥ 0,9.
Maximum working ambient temperature: 55°C.
Installation height: 3 - 8 m.
Installation: with die-cast aluminium suspension hook and safety fixing bolts.

GE Consumer & Industrial 88


Lighting
LOWMOUNT

Tot. Absorbed Weight Pack Product


Type Lamp Power (W) (kg) Qty. Code

IP 52 gearbox Class: I
381 230V 50Hz IEC - CEI
L4MD25S LU250/T/40 275 7,50 1 30878
L4MD40S LU400/T/40 436 8,60 1 30913
L4MD25MBF MVR250/U/40 275 7,50 1 30923
L4MD40MBF MVR400/U/40 430 7,60 1 30936
HPF = with power factor correction - Without lamp.
540

IP 54 gearbox Class: I
230V 50Hz IEC - CEI
L4MD25SW LU250/T/40 275 7,50 1 30879
L4MD40SW LU400/T/40 436 8,60 1 30892
773 L4MD25MBFW MVR250/U/40 275 7,50 1 30922
L4MD40MBFW MVR400/U/40 430 7,60 1 30930
HPF = with power factor correction - Without lamp.

Diameter Weight Pack Product


Type Lamp (mm) (kg) Qty. Code

IP 52 reflector – diffuser
L4MDLE MVR250/U/40 773 4,00 1 31335
L4MDLD other types 773 4,00 1 31333

IP 54 reflector – diffuser
L4MDLEW MVR250/U/40 773 4,00 1 31336
L4MDLDW other types 773 4,00 1 31334
13

Weight Pack Product


Type Description (kg) Qty. Code
117
105
Suspension hook
HOOKM With seal IP52 0,15 1 31232
HOOKMG With seal IP54 0,16 1 31269

SFC3-B SFC-O

Accessories
Safety chain
SFC3-B For the body, of 0,9 m length 0,25 1 31273
SFC-O For the reflector 0,10 1 31277

GE Consumer & Industrial 89


Lighting
CONSERVA 250
Indoor luminaires for 70W, 100W and 250W clear bulb high-pressure sodium
and 250W metal halide lamps.
Intended for use in either commercial or industrial applications with installation
heights of 2-6 m.
Gearbox: die-cast aluminium ballast housing with electrocoat grey paint finish,
with 230V 50Hz power supply unit with power factor correction, lampholder
and hinge for fastening the reflector.
Hub on the top allows quick and safe electrical and mechanical connection of
the die-cast aluminium power supply unit box by using a slide. The suspending
hook should be screwed to the power supply unit box.
Safety chain provisions available.
Reflector: anodised polished “ALZAK” aluminium covered from the bottom by
die-cast UV-stabilised polycarbonate low luminance prismatic refractor
fastened by insulating ring to the reflector.
The hinged reflector is fastened to the body through gasket by 2 stainless steel
latches protecting the lamp against fall.
Lampholder: E40 porcelain.
Power supply: 230V 50Hz, with power factor correction, cos j ≥ 0,9.
Maximum working ambient temperature: 55°C for 70 and 100W versions; 40°C
for other versions.
Installation heights: 2 - 6 m.
Installation: through the power supply unit box by using of die-cast aluminium
suspending hook.

318

Tot. Absorbed Weight Pack Product


Type Lamp Power (W) (kg) Qty. Code

417
IP 52 gearbox Clase: I
230V 50Hz IEC - CEI
MPB79S LU70/90/T12/27 81 2,00 1 30851
MPB11S LU100/100/T/40 112 2,30 1 30863
572
MPB25S LU250/T/40 275 3,20 1 30864
MPB25MBF MVR250/U/40 268 2,30 1 30865
HPF = with power factor correction - Without lamp.

Diameter Weight Pack Product


Type (mm) (kg) Qty. Code

IP 54 reflector – diffuser
C1SEL 572 2,80 1 31323

Weight Pack Product


Type Description (kg) Qty. Code

Suspension hook
13

HOOKM With seal IP52 0,15 1 31232


86
117
105

56 93
Power supply box
MPM-3PF With seal IP52 0,33 1 31332

SFC3-B

Weight Pack Product


Type Description (kg) Qty. Code
Accessories
Safety chain
SFC3-B For the body, of 0,9 m length 0,25 1 31273

GE Consumer & Industrial 90


Lighting
CONSERVA 400
Indoor luminaires for 250W and 400W clear bulb high-pressure sodium and
metal halide lamps. Intended for use in either commercial or industrial
applications with installation heights of 3-8 m.
Gearbox: die-cast aluminium ballast housing with electrocoat grey paint finish.
It contains 230V 50Hz power supply unit with power factor correction,
prepared for quick electronic and mechanic connection to the reflector
containing also the lampholder.
Threaded hub on the top allows quick and safe installation with matching hook
(not included).
Safety chain provisions available.
Reflector: anodised polished “ALZAK” aluminium covered from the bottom by
die-cast UV-stabilised polycarbonate low luminance prismatic refractor
containing the”base down” lampholder.
Carbon filter in the body preserves the optics from the external contaminating
agents. The hinged reflector is fastened to the body through gasket by 2 strong
stainless steel latches protecting the lamp against fall.
Lampholder: E40 porcelain.
Power supply: 230V 50Hz, with power factor correction, cos j ≥ 0,9.
Maximum working ambient temperature: 40°C.
Installation height: 3 - 8 m.
Installation: through the power supply unit box by using of die-cast aluminium
suspending hook.

318

Tot. Absorbed Weight Pack Product


Type Lamp Power (W) (kg) Qty. Code
515
IP 52 gearbox Class: I
230V 50Hz IEC - CEI
C4S25S LU250/T/40 275 5,40 1 30824
773 C4S40S LU400/T/40 436 6,50 1 30836
C4S25MBF MVR250/U/40 275 5,40 1 30849
C4S40MBF MVR400/U/40 430 5,50 1 30850
HPF = with power factor correction - Without lamp.

Diameter Weight Pack Product


Type (mm) (kg) Qty. Code

IP 54 reflector - diffuser
C4SEL 773 3,70 1 31330

Weight Pack Product


Type Description (kg) Qty. Code

Suspension hook
13

HOOKM With seal IP52 0,15 1 31232


86
117
105

56 93
Power supply box
MPM-3PF With seal IP52 0,33 1 31332

SFC3-B

Weight Pack Product


Type Description (kg) Qty. Code
Accessories
Safety chain
SFC3-B For the body, of 0,9 m length 0,25 1 31273

GE Consumer & Industrial 91


Lighting
OMG OMNIGLOW

Luminaire available in two versions, open and ventilated (OMG) or enclosed


suitable for use in damp environments (OMGC), both for discharge lamps up
to 1000 W. Optical assembly available in two sizes: 14” and 18”.

APPLICATIONS
Particularly suitable for commercial and industrial lighting
applications with a mounting height over 4 meters.

Incident light Reflected light


Rayo incidente Rayo reflejado

Total reflection prisms.


The light hits both surfaces of the prism at 45°, so that the ray is
reflected.

GE Consumer & Industrial 92


Lighting
OMG OMNIGLOW

TECHNICAL CHARACTERISTICS • características técnicas

Ballast housing
Standard Optional
Ballast housing • Caja de equipo
IIPP 5522 IIPP 5544
• Available in two sizes: AG5 • The socket holder, joined to • Easy installation using a 3/4”
up to 1000 W and AP5 up to the ballast housing, enables NPSC threaded hub, located
Optical assembly
400 W. Die-cast aluminium photometric distribution to in the housing and resistant Opened Standard enclosed Optional enclosed
ballast housing, with white be set in 8 different positions to vibration.
polyester powder paint fi- using an ordinary screwdri- II PP 2200 IIPP 5544 IIPP 6655
nish applied electrostatically ver. Porcelain E40 or E27
and cured at 180°C over an lamp socket according to
anti-corrosion layer. the type of lamp used.
Class:
Clase: I

MH/HAL 175W 1000W


Metal Halide Lamps

HPS/SAP 70W 1000W


High Pressure Sodium Lamps

MV/VM 250W 1000W


Mercury Vapor Lamps

Net weight from approx. 14 to 24 Kg.

A mm B mm C mm

OMG-14 588 350 608


OMGC-14 609 350 629
OMG-18 604 470 624
OMGC-18 625 470 645
Optical assembly

• Borosilicate glass reflector Reflector support frame, • Tempered protection glass • EPDM or silicon gasket ,
with total reflection prisms made of three steel rods (closed version only) resis- according to the lamp wat-
in the outer part, available in and a lower zinc plated ring tant to thermal and mecha- tage, between the reflector
two sizes: small (model 14) supporting the glass; the nical stress. Fixed in a metal and the metal parts.
for lamps up to 400 W and rods hold the glass in positi- ring with gasket it is fitted Optionally, lamps up to 400
large (model 18) for lamps on, fixing the ring to the with a hinge and two latches W can be supplied with a
up to 1000 W. top reflector cap. to guarantee easy removal. large ballast housing AG5
White spun aluminium cover • capable of supporting a ro-
connecting the reflector to om temperature up to 65°C.
the ballast housing. The • For higher temperatures
open version has three rec- please request further
tangular windows, whereas information.
the closed version has a
gasket to adjust the position
of the ballast housing.

GE Consumer & Industrial 93


Lighting
OMG OMNIGLOW

COMPONENTS

1 Ballast housing AG5.


2 Ballast housing AP5.
3 3/4” NPSC threaded hub (*).
4 Socket holder allowing the lamp to
be adjusted to 8 different positions.
5 Lamp socket.
6 Gasket between top cap and housing
(OMGC version only).
7 Aluminium reflector cap with
windows only in the opened versions
(OMG).
8 Borosilicate glass reflector.
9 Three steel rods.
10 Zinc plated steel support ring.
11 Gaskets supporting glass reflector.
12 Flat tempered glass door (OMGC
version only).

ORDERING INFORMATION

Luminaire Optical assembly Housing Lamp type Voltage Frequency Power factor Options

OMG: 14: 350 mm AP5: MH175W 208 V 50 Hz HPF: E: Electronic emergency device
Opened (max 400 W) (max 400 MH250W 220 V 60 Hz High power
W) 230 V factor
MH400W
18: 470 mm 240 V IP 65: Optical assembly IP 65
OMGC: (max 1000 AG5: MH1000W 277 V (enclosed version)
Enlosed W) (max 1000 HPS70W
W) HPS100W
IP 54: Ballast housing IP 54
HPS150W
(enclosed version)
HPS250W
HPS400W
HPS600W *R: Ballast reactor type
HPS750W
HPS1000W **S: Magnetic regulator
MV250W
MV400W
MV1000W
OMG 18C AP5 MH400W 220 V 50 Hz HPF R IP 65 IP 54
The standard ballasts are of the following types:
MV250W up to 1000W Reactor
HPS250W up to 600W Reactor
HPS750W, 1000W CWA
MH175W up to 1000W CWA

*The following types are also available on request:


MH250W, 400W Reactor (Mercury type+Ignitor)
**Only for Super High Output long life, MH400W lamp (uses AG5)

NOTES

• Always use the large ballast housing (AG5) for 600 W to 1000 W lamps.
• When using the large optical assembly (18) with lamps up to 400W, a narrower photometric distribution is achieved.
• The MH 1000 W lamps used in the enclosed versions must be of reduced jacket BT 37 type. Optional IP65 (for optical assembly) and
IP54 (for ballast housing) available for enclosed versions only.
• For electronic emergency devices, fuses, suspension accessories (i.e., HOOKM), etc., please see pages 64-65. They must be ordered
separately.

GE Consumer & Industrial 94


Lighting
GHPB

Open and ventilated unit, for discharge lamps up to 250 W


(GHBP-16) and up to 400 W (GHBP-22).

Ballast housing MH/HAL 250W 400W


Metal Halide Lamps

II PP 5522 APPLICATIONS
HPS/SAP 150W 400W Particularly suitable for industrial and commercial lighting
High Pressure Sodium Lamps
Optical assembly applications; mounting height over 4 meters (medium-high).

IIPP 2200 MV/VM 250W


Mercury Vapor Lamps
400W

Class:
Clase: I Net weight from approx. 9 to 16 Kg.

TECHNICAL CHARACTERISTICS

Die-cast aluminium ballast • The socket holder, joined to • Easy installation using a 3/4” The optical assembly com-
housing, with grey polyester the ballast housing, enables NPSC threaded hub, located prises an injection moulded,
powder paint finish applied on-site adjustment of photo- in the housing and resistant UV stabilised acrylic reflec-
electrostatically and cured metric distribution to 5 diffe- to vibrations. tor with total reflection pri-
at 180°C over an anti-corro- rent positions using an ordi- sms, available in two sizes
sion layer. nary screwdriver. Porcelain (diameter 413 mm for GHBP-
E40 or E27 lamp socket ac- 16 and 571 mm for GHBP-
cording to the type of lamp 22).
used.

GE Consumer & Industrial 95


Lighting
GHPB
ORDERING INFORMATION

Luminaire Optical assembly Lamp type Voltage Frequency Power factor


Options

GHBP 16: 413 mm (max 250 W) MH250W 208 V 50 Hz HPF: E: Electronic emergency device
MH400W 220 V 60 Hz High power
22: 571 mm (max 400 W) HPS70W 230 V factor
HPS100W 240 V *R: Ballast reactor type
HPS150W 277 V
HPS250W
HPS400W
MV250W
MV400W
GHBP 22 MH400W 220 V 50 Hz HPF

The standard ballasts are of the following types:


MV250W, 400W Reactor
HPS70W up to 400W Reactor
MH250W, 400W CWA

*The following types are also available on request:


MH250W, 400W Reactor (Mercury type+Ignitor)

NOTES

• In case a bottom enclosure is needed, contact factory.


• For electronic emergency devices, fuses, suspension accesories (i.e., HOOKM), etc.,
They must be ordered separately.

Dimensions in mm

PHOTOMETRIC DATA

GHBP-16; Lampholder position / 4; Lamps ST 70/150 GHBP-16; Lampholder position / 5; Lamps ST 250
POLAR DIAGRAM NORMAL EFFICIENCY POLAR DIAGRAM NORMAL EFFICIENCY
ULOR 0.048 DLOR 0.850 LOR 0.898 ULOR 0.133 DLOR 0.778 LOR 0.911

(cd/1000 lm) CIE FLUX CODE (cd/1000 lm) CIE FLUX CODE
CIE FLUX CODE 74 93 97 95 90 CIE FLUX CODE 50 88 94 85 91

SPACING HEIGHT RATIO SPACING HEIGHT RATIO


SHR NOM 1.50 SHR NOM 1.90

UTILISATION FACTOR - UF (Floor) UTILISATION FACTOR - UF (Floor)


REFLECTION FACTOR ROOM INDEX REFLECTION FACTOR ROOM INDEX
Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00 Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.610 0.670 0.750 0.800 0.850 0.880 0.890 0.70 0.50 0.10 0.490 0.560 0.670 0.730 0.790 0.820 0.840
0.30 0.560 0.620 0.710 0.770 0.830 0.860 0.870 0.30 0.420 0.500 0.610 0.680 0.760 0.790 0.810
0.10 0.530 0.590 0.680 0.740 0.810 0.840 0.860 0.10 0.370 0.450 0.570 0.650 0.730 0.760 0.790
0.50 0.50 0.10 0.600 0.650 0.730 0.780 0.830 0.850 0.860 0.50 0.50 0.10 0.460 0.530 0.630 0.690 0.750 0.780 0.790
0.30 0.560 0.610 0.700 0.750 0.810 0.830 0.850 0.30 0.400 0.470 0.590 0.650 0.720 0.750 0.770
0.10 0.520 0.580 0.670 0.730 0.790 0.820 0.840 0.10 0.360 0.430 0.550 0.620 0.700 0.730 0.750
0.30 0.50 0.10 0.580 0.640 0.710 0.760 0.810 0.830 0.840 0.30 0.50 0.10 0.440 0.500 0.600 0.660 0.710 0.740 0.750
0.30 0.550 0.600 0.680 0.740 0.790 0.810 0.830 0.30 0.390 0.460 0.560 0.620 0.690 0.720 0.730
0.10 0.520 0.570 0.660 0.720 0.770 0.800 0.820 0.10 0.350 0.420 0.530 0.600 0.670 0.700 0.720
0.70 0.70 0.30 0.750 0.810 0.900 0.950 1.010 1.030 1.050 0.70 0.70 0.30 0.630 0.710 0.820 0.880 0.950 0.980 1.000
0.50 0.650 0.720 0.820 0.890 0.960 0.990 1.010 0.50 0.510 0.600 0.730 0.800 0.890 0.930 0.960
0.50 0.70 0.30 0.710 0.760 0.840 0.890 0.940 0.960 0.970 0.50 0.70 0.30 0.580 0.650 0.750 0.810 0.860 0.890 0.900
0.70 0.10 0.660 0.710 0.770 0.810 0.850 0.870 0.880 0.70 0.10 0.540 0.600 0.690 0.740 0.780 0.800 0.820

GHBP-22; Lampholder position / 5; Lamps ST 400 GHBP-22; Lampholder position / 3; Lamps QE/ME 400
POLAR DIAGRAM NORMAL EFFICIENCY POLAR DIAGRAM NORMAL EFFICIENCY
ULOR 0.106 DLOR 0.763 LOR 0.869 ULOR 0.158 DLOR 0.720 LOR 0.878

(cd/1000 lm) CIE FLUX CODE (cd/1000 lm) CIE FLUX CODE
CIE FLUX CODE 68 89 95 88 87 CIE FLUX CODE 62 85 92 82 88

SPACING HEIGHT RATIO SPACING HEIGHT RATIO


SHR NOM 1.60 SHR NOM 1.50

UTILISATION FACTOR - UF (Floor) UTILISATION FACTOR - UF (Floor)


REFLECTION FACTOR ROOM INDEX REFLECTION FACTOR ROOM INDEX
Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00 Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.550 0.600 0.680 0.740 0.790 0.810 0.830 0.70 0.50 0.10 0.510 0.570 0.650 0.700 0.760 0.790 0.800
0.30 0.490 0.550 0.640 0.700 0.760 0.790 0.810 0.30 0.450 0.510 0.600 0.660 0.730 0.760 0.780
0.10 0.460 0.520 0.610 0.670 0.740 0.770 0.790 0.10 0.410 0.470 0.570 0.630 0.700 0.740 0.760
0.50 0.50 0.10 0.530 0.580 0.660 0.700 0.750 0.780 0.790 0.50 0.50 0.10 0.480 0.540 0.620 0.660 0.720 0.740 0.760
0.30 0.480 0.540 0.620 0.670 0.730 0.760 0.770 0.30 0.440 0.490 0.580 0.630 0.690 0.720 0.740
0.10 0.450 0.500 0.590 0.650 0.710 0.740 0.760 0.10 0.400 0.450 0.540 0.600 0.670 0.700 0.720
0.30 0.50 0.10 0.510 0.560 0.630 0.670 0.720 0.740 0.750 0.30 0.50 0.10 0.460 0.510 0.580 0.630 0.670 0.700 0.710
0.30 0.470 0.520 0.600 0.650 0.700 0.730 0.740 0.30 0.420 0.470 0.550 0.600 0.650 0.680 0.700
0.10 0.440 0.490 0.570 0.630 0.690 0.710 0.730 0.10 0.390 0.440 0.520 0.570 0.630 0.660 0.680
0.70 0.70 0.30 0.680 0.740 0.830 0.880 0.940 0.960 0.980 0.70 0.70 0.30 0.640 0.700 0.800 0.850 0.910 0.940 0.960
0.50 0.580 0.640 0.750 0.810 0.880 0.920 0.940 0.50 0.540 0.600 0.7100 0.780 0.850 0.890 0.920
0.50 0.70 0.30 0.630 0.680 0.760 0.810 0.860 0.880 0.890 0.50 0.70 0.30 0.590 0.640 0.720 0.770 0.820 0.850 0.860
0.70 0.10 0.590 0.630 0.700 0.740 0.780 0.800 0.810 0.70 0.10 0.550 0.600 0.660 0.700 0.750 0.770 0.780

GE Consumer & Industrial 96


Lighting
OMBS OMNIBEAM

Luminaire with an open and ventilated acrylic reflector, for APPLICATIONS


discharge lamps up to 400 W. The unit can be supplied enclosed Suitable for the lighting of commercial areas, as well as applications
under request. such as assembly lines, inspection areas, production bays, storage
areas, hangars and railway stations, with mounting height over
5 meters.

TECHNICAL CHARACTERISTICS

Die-cast aluminium ballast Eight-position mounting Ballast housing


housing, with white polyes- bracket , allowing different
ter powder paint finish appli- light distributions. Porcelain IP 52
ed electrostatically and cu- E40 lamp socket.
red at 180°C over an anti- Optical assembly
corrosion layer. UV stabilized acrylic prisma-
tic reflector.
Easy installation using a 3/4” IP 20
NPSC threaded hub, located
in the housing and resistant
to vibrations.
Class: I

MH/HAL 250W 400W


Metal Halide Lamps

HPS/SAP 250W 400W


High Pressure Sodium Lamps

MV/VM 250W 400W


Mercury Vapor Lamps

Net weight from approx. 14 to 21 Kg.

GE Consumer & Industrial 97


Lighting
OMG OMNIBEAM
ORDERING INFORMATION

Luminaire Lamp type Voltage Frequency Power factor Options

OMBS MH250W 208 V 50 Hz HPF: E: Electronic emergency device


MH400W 220 V 60 Hz High power factor *R: Ballast reactor type
HPS250W 230 V
HPS400W 240 V
MV250W 277 V
MV400W

OMBS MH400W 220V 50Hz HPF

The standard ballasts are of the following types:


MV250W, 400W Reactor
HPS250W, 400W Reactor
MH250W, 400W CWA

* The following types are also available on request:


MH250W, 400W Reactor (Mercury type+Ignitor)

PHOTOMETRIC DATA
OMBS; Lampholder position G; Lamps ST 250/400
POLAR DIAGRAM NORMAL EFFICIENCY
ULOR 0.080 DLOR 0.866 LOR 0.947

(cd/1000 lm) CIE FLUX CODE


CIE FLUX CODE 57 88 94 92 95

SPACING HEIGHT RATIO


SHR NOM 1.7

UTILISATION FACTOR - UF (Floor)


REFLECTION FACTOR ROOM INDEX
Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.70 0.30 0.700 0.770 0.890 0.950 1.020 1.050 1.070
0.50 0.30 0.580 0.660 0.790 0.870 0.950 0.990 1.020
0.10 0.550 0.620 0.730 0.790 0.850 0.880 0.890
0.30 0.10 0.490 0.560 0.670 0.740 0.810 0.850 0.870
0.50 0.50 0.30 0.560 0.630 0.750 0.820 0.890 0.920 0.940
0.10 0.530 0.600 0.700 0.760 0.820 0.840 0.860
0.30 0.30 0.490 0.570 0.690 0.760 0.850 0.890 0.910
0.10 0.480 0.550 0.650 0.720 0.790 0.820 0.840
0.30 0.30 0.10 0.460 0.530 0.630 0.700 0.760 0.790 0.810
0.10 0.10 0.430 0.490 0.600 0.670 0.740 0.770 0.790
0.00 0.00 0.00 0.400 0.470 0.570 0.640 0.700 0.730 0.750

GE Consumer & Industrial 98


Lighting
HIPER

Compact luminaire for discharge lamps up to 400 W with open, ventila-


ted optical assembly (can be enclosed on request) which guarantees
extremely effective, low glare lighting thanks to its faceted reflector.

APPLICATIONS
Particularly suitable for large areas as supermarkets and shopping malls;
mounting height over 4 meters.

TECHNICAL CHARACTERISTICS
Open and ventilated Aluminium faceted reflector.
luminaire with flat glass The faceted design reduces IP 20
door on request. and controls the glare of the
lamp.
Housing in heavy duty steel
plate, with polyester powder E40 porcelain lamp socket. Class: I
paint finish applied
electrostatically and cured
at 180°C over an
MH 250W 400W
Metal Halide Lamps
anti-corrosion layer.
HPS 250W 400W
High Pressure Sodium Lamps

MV 400W
Mercury Vapor Lamps

Net weight from approx. 15 to 18 Kg.

Dimensions in mm

GE Consumer & Industrial 99


Lighting
HIPER
ORDERING INFORMATION

Luminaire Lamp type Voltage Frequency Power factor Options

HIPER MH250W 208 V 50 Hz HPF: E: Electronic emergency device


MH400W 220 V 60 Hz High power
HPS250W 230 V factor V: With glass door enclosure
HPS400W 240 V
MV400W 277 V *R: Ballast reactor type

**S: Magnetic regulator

HIPER MH250W 220 V 50 Hz HPF E

The standard ballasts are of the following types:


MV400W Reactor
HPS250W, 400W Reactor
MH250W, 400W CWA

*The following types are also available on request:


MH250W, 400W Reactor (Mercury type+Ignitor)
**Only for Super High Output, long life, MH400W lamp

PHOTOMETRIC DATA
HIPER; Lampholder position: FIXED; Lamps QE 400 - ME 250/400
POLAR DIAGRAM NORMAL EFFICIENCY
ULOR 0.000 DLOR 0.758 LOR 0.758

(cd/1000 lm) CIE FLUX CODE


CIE FLUX CODE 62 97 100 100 76

SPACING HEIGHT RATIO


SHR NOM 1.90

UTILISATION FACTOR - UF (Floor)


REFLECTION FACTOR ROOM INDEX
Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.480 0.540 0.630 0.680 0.730 0.750 0.760
0.30 0.430 0.500 0.590 0.650 0.710 0.730 0.740
0.10 0.390 0.460 0.570 0.630 0.690 0.720 0.730
0.50 0.50 0.10 0.470 0.530 0.620 0.670 0.710 0.730 0.740
0.30 0.430 0.490 0.590 0.640 0.700 0.720 0.730
0.10 0.390 0.460 0.560 0.620 0.680 0.710 0.720
0.30 0.50 0.10 0.460 0.520 0.610 0.660 0.700 0.720 0.730
0.30 0.420 0.480 0.580 0.630 0.690 0.710 0.720
0.10 0.390 0.460 0.560 0.620 0.670 0.700 0.710
0.70 0.70 0.30 0.600 0.660 0.760 0.810 0.860 0.880 0.900
0.50 0.510 0.580 0.690 0.750 0.820 0.850 0.870
0.50 0.70 0.30 0.570 0.630 0.720 0.760 0.810 0.830 0.840
0.70 0.10 0.530 0.580 0.660 0.700 0.740 0.750 0.760

HIPER; Lampholder position / FIXED; Lamps ST 250/400 HIPER; Lampholder position / FIXED; Lamps MC 250/400
POLAR DIAGRAM NORMAL EFFICIENCY POLAR DIAGRAM NORMAL EFFICIENCY
ULOR 0.000 DLOR 0.823 LOR 0.823 ULOR 0.000 DLOR 0.796 LOR 0.796

(cd/1000 lm) CIE FLUX CODE (cd/1000 lm) CIE FLUX CODE
CIE FLUX CODE 67 99 100 100 82 CIE FLUX CODE 60 99 100 100 80

SPACING HEIGHT RATIO SPACING HEIGHT RATIO


SHR NOM 1.40 SHR NOM 1.60

UTILISATION FACTOR - UF (Floor) UTILISATION FACTOR - UF (Floor)


REFLECTION FACTOR ROOM INDEX REFLECTION FACTOR ROOM INDEX
Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00 Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.540 0.610 0.700 0.750 0.800 0.820 0.830 0.70 0.50 0.10 0.500 0.560 0.660 0.720 0.760 0.780 0.790
0.30 0.500 0.560 0.670 0.730 0.780 0.800 0.820 0.30 0.440 0.520 0.620 0.690 0.740 0.770 0.780
0.10 0.460 0.530 0.640 0.700 0.760 0.790 0.800 0.10 0.410 0.480 0.590 0.660 0.720 0.750 0.760
0.50 0.50 0.10 0.540 0.600 0.690 0.740 0.790 0.810 0.820 0.50 0.50 0.10 0.490 0.550 0.650 0.700 0.750 0.770 0.780
0.30 0.490 0.560 0.660 0.720 0.770 0.790 0.800 0.30 0.440 0.510 0.620 0.680 0.730 0.750 0.760
0.10 0.460 0.530 0.630 0.690 0.750 0.780 0.790 0.10 0.400 0.480 0.590 0.650 0.710 0.740 0.750
0.30 0.50 0.10 0.530 0.590 0.680 0.730 0.770 0.790 0.800 0.30 0.50 0.10 0.480 0.540 0.640 0.690 0.740 0.750 0.760
0.30 0.490 0.550 0.650 0.710 0.760 0.780 0.790 0.30 0.430 0.500 0.610 0.670 0.720 0.740 0.750
0.10 0.460 0.520 0.630 0.690 0.750 0.770 0.780 0.10 0.400 0.470 0.580 0.650 0.700 0.730 0.740
0.70 0.70 0.30 0.670 0.740 0.840 0.890 0.940 0.970 0.980 0.70 0.70 0.30 0.620 0.690 0.790 0.850 0.900 0.930 0.940
0.50 0.580 0.650 0.770 0.830 0.900 0.930 0.950 0.50 0.520 0.600 0.720 0.790 0.860 0.890 0.910
0.50 0.70 0.30 0.640 0.700 0.790 0.840 0.890 0.910 0.920 0.50 0.70 0.30 0.590 0.660 0.750 0.800 0.850 0.870 0.880
0.70 0.10 0.600 0.650 0.730 0.770 0.810 0.820 0.830 0.70 0.10 0.550 0.610 0.690 0.730 0.770 0.790 0.790

GE Consumer & Industrial 100


Lighting
VSG VERSAGLOW

Enclosed luminaires suitable for damp environments, for discharge lamps up


APPLICATIONS to 250 W (VSG-250) or up to 150 W (VSG-150). The prismatic refractor
Suitable for the lighting of classrooms, offices, cafeterias and commercial provides high level of visual comfort in installations with direct-indirect
areas, with mounting heights between 2.2 and 7 meters. lighting.

TECHNICAL CHARACTERISTICS
Die-cast aluminium ballast Porcelain E40 or E27 lamp
housing, with grey polyester socket, according to the IP 42
powder paint finish applied lamp used.
electrostatically and cured
at 180°C over an UV stabilised acrylic
anti-corrosion layer. prismatic refractor (in Class: I
LEXAN®1 polycarbonate on
Sliding disconnect, request) offering high visual
guarantees safe and easy comfort thanks to uniform MH 70W 250W
electrical and mechanical light distribution over the Metal Halide Lamps
assembling with the optical. whole surface.
Please request information HPS 70W 250W
on the possibility of High Pressure Sodium Lamps
installation using a 3/4”
threaded hub. MV 125W 250W
Mercury Vapor Lamps

ØB Net weight from approx. 10 to 16Kg.

A mm ØB mm
VSG-150 311 567
VSG-250 352 768

GE Consumer & Industrial 101


Lighting
VSG VERSAGLOW
ORDERING INFORMATION

Luminaire Optional refractor Lamp type Voltage Frequency Power factor Options

VSG-150 P: MH70W 208 V 50 Hz HPF: E: Electronic emergency device


VSG-250 Polycarbonate LEXAN MH100W 220 V 60 Hz High power
MH150W 230 V factor
MH175W 240 V *R: Ballast reactor type
MH250W 277 V
HPS70W
HPS100W
HPS150W
HPS250W
MV125W
MV250W

VSG-150 MH100W 220 V 50 Hz HPF

The standard ballasts are of the following types:


MV125W, 250W Reactor
HPS70W up to 250W Reactor
MH70W up to 150W Reactor (HPS ballast+Ignitor)
MH175W, 250W CWA

* The following type is also available on request:


MH250W Reactor (Mercury type+Ignitor)

NOTES
• For electronic emergency devices, fuses, suspension accesories, etc. must be ordered separately.

PHOTOMETRIC DATA
VSG-150; Lampholder position: Fixed; Lamps ST 70/150 VSG-250; Lampholder position: Fixed; Lamps ST 250
POLAR DIAGRAM NORMAL EFFICIENCY POLAR DIAGRAM NORMAL EFFICIENCY
ULOR 0.265 DLOR 0.539 LOR 0.804 ULOR 0.304 DLOR 0.525 LOR 0.828

(cd/1000 lm) CIE FLUX CODE (cd/1000 lm) CIE FLUX CODE
CIE FLUX CODE 35 66 88 67 80 CIE FLUX CODE 34 65 87 63 83

SPACING HEIGHT RATIO SPACING HEIGHT RATIO


SHR NOM 1.5 SHR NOM 1.6

UTILISATION FACTOR - UF (Floor) UTILISATION FACTOR - UF (Floor)


REFLECTION FACTOR ROOM INDEX REFLECTION FACTOR ROOM INDEX
Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00 Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.70 0.30 0.480 0.530 0.630 0.690 0.750 0.790 0.810 0.70 0.70 0.30 0.480 0.540 0.640 0.700 0.760 0.800 0.820
0.50 0.30 0.370 0.430 0.540 0.610 0.690 0.740 0.760 0.50 0.30 0.370 0.440 0.540 0.610 0.700 0.750 0.780
0.10 0.350 0.400 0.490 0.550 0.610 0.650 0.670 0.10 0.350 0.410 0.500 0.560 0.620 0.660 0.680
0.30 0.10 0.290 0.340 0.440 0.500 0.570 0.620 0.640 0.30 0.10 0.290 0.340 0.440 0.510 0.580 0.620 0.650
0.50 0.50 0.30 0.330 0.380 0.470 0.530 0.600 0.640 0.660 0.50 0.50 0.30 0.330 0.380 0.470 0.530 0.600 0.640 0.670
0.10 0.310 0.360 0.440 0.490 0.550 0.580 0.600 0.10 0.310 0.360 0.440 0.490 0.550 0.590 0.610
0.30 0.30 0.270 0.320 0.410 0.480 0.560 0.600 0.630 0.30 0.30 0.270 0.320 0.410 0.480 0.560 0.600 0.630
0.10 0.260 0.310 0.390 0.450 0.520 0.560 0.580 0.10 0.260 0.310 0.390 0.450 0.520 0.560 0.580
0.30 0.30 0.10 0.230 0.280 0.350 0.410 0.470 0.500 0.520 0.30 0.30 0.10 0.230 0.270 0.350 0.400 0.460 0.500 0.520
0.10 0.10 0.200 0.240 0.320 0.380 0.440 0.480 0.510 0.10 0.10 0.200 0.240 0.320 0.370 0.440 0.480 0.500
0.00 0.00 0.00 0.160 0.200 0.260 0.310 0.370 0.400 0.420 0.00 0.00 0.00 0.150 0.190 0.250 0.300 0.350 0.390 0.410

GE Consumer & Industrial 102


Lighting
GGD GARAGE GARD
Luminaire, suitable for use in damp environments 70-100-150W high
pressure sodium and metal halide lamps. The special distribution of light throu-
gh the prismatic refractor, enables it to be used in area with reduced mounting
heights giving excellent illumination on vertical surfaces.
Applications
Particularly suitable for underground car parks and garages for warehouses,
service stations, stairways, working areas and task lighting. Mounting high
above 2.2 meter.
Key Features
• Body, in die cast aluminium with grey polyester powder paint finish, applied
electrostaticaly and cured at 180 (C, over an anti-corrotion layer.
• Easy installation through a ceiling mounting plate
• Ballast housing fitted with an oven-cured white aluminium reflector.

Lamp Weight Pack Qty Product


Type Type (Kg) Box Code

GGD Class: I IP 20
230V 50Hz IEC - CEI
GGD15SA LU150/T/40 7,00 1 17274
GGD15HAL MH150 7,00 1 17275

GE Consumer & Industrial 103


Lighting
Photometric data
CPC 400 EB250M1
POLAR DIAGRAM NORMAL EFFICIENCY POLAR DIAGRAM NORMAL EFFICIENCY
OF OUTPUT ULOR 0.000 DLOR 0.573 LOR 0.573 OF OUTPUT ULOR 0.000 DLOR 0.785 LOR 0.785

(cd/1000 lm) 90°


CIE FLUX CODE (cd/1000 lm) CIE FLUX CODE
90°
CIE FLUX CODE 57 91 98 100 57 CIE FLUX CODE 94 99 99 100 78
Semipiani C 180°
180.0° 0.0° Semipiani C 180°

90.0° 270.0°

§SPACING – HEIGHT RATIO
180.0° 0.0°
0° SPACING – HEIGHT RATIO
SHR NOM 0.75 SHR MAX 0.93
270° SHR NOM 2.00 SHR MAX 2.03 SHR MAX TR 2.27
270°
Angoli Gamma UTILISATION FACTOR – UF (Floor) UTILISATION FACTOR – UF (Floor)
Angoli Gamma
120 135 150 180 REFLECTION FACTOR ROOM INDEX REFLECTION FACTOR ROOM INDEX
120 135 150 180
105
Ceiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00 Ceiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.379 0.472 0.511 0.536 0.561 0.574 0.582 105 0.70 0.50 0.10 0.679 0.731 0.759 0.787 0.801 0.809
0.30 0.346 0.447 0.490 0.518 0.547 0.562 0.572 0.30 0.651 0.708 0.739 0.772 0.789 0.799
90
0.10 0.322 0.428 0.473 0.503 0.535 0.552 0.563 0.10 0.629 0.690 0.723 0.759 0.778 0.790
90
0.50 0.50 0.10 0.372 0.465 0.503 0.527 0.550 0.562 0.570 0.50 0.50 0.10 0.671 0.722 0.747 0.773 0.786 0.794
75 0.30 0.343 0.443 0.485 0.512 0.538 0.553 0.562 0.30 0.646 0.701 0.731 0.761 0.777 0.786
200
75 0.10 0.321 0.427 0.470 0.498 0.528 0.544 0.555 0.10 0.627 0.685 0.716 0.750 0.768 0.779
75
150 0.30 0.50 0.10 0.367 0.459 0.495 0.518 0.541 0.552 0.559 0.30 0.50 0.10 0.663 0.711 0.736 0.761 0.773 0.780
400
0.30 0.340 0.440 0.479 0.505 0.531 0.544 0.553 0.30 0.641 0.694 0.722 0.751 0.765 0.774
0.10 0.319 0.424 0.466 0.494 0.522 0.537 0.546 0.10 0.624 0.680 0.709 0.741 0.758 0.767
60 225
0.70 0.50 0.20 0.389 0.487 0.533 0.563 0.593 0.609 0.620 60 600 0.70 0.50 0.20 0.702 0.763 0.796 0.833 0.851 0.863
0.30 0.352 0.458 0.506 0.539 0.574 0.594 0.607 0.30 0.666 0.732 0.769 0.810 0.833 0.848
300
0.10 0.325 0.435 0.485 0.520 0.558 0.580 0.595 800 0.10 0.639 0.708 0.747 0.792 0.818 0.834
0.50 0.50 0.20 0.381 0.477 0.519 0.546 0.573 0.588 0.597 0.50 0.50 0.20 0.688 0.745 0.774 0.805 0.822 0.831
cd/klm 0.30 0.658 0.718 0.752 0.788 0.807 0.819
0.30 0.347 0.451 0.497 0.527 0.558 0.575 0.586 cd/klm
30 15 0
0.10 0.323 0.432 0.478 0.510 0.544 0.564 0.576 30 15 0 0.10 0.634 0.697 0.733 0.773 0.795 0.809

CPC 400 + CPG EB250M4


POLAR DIAGRAM NORMAL EFFICIENCY POLAR DIAGRAM NORMAL EFFICIENCY
OF OUTPUT ULOR 0.000 DLOR 0.480 LOR 0.480 OF OUTPUT ULOR 0.000 DLOR 0.799 LOR 0.799

(cd/1000 lm) CIE FLUX CODE (cd/1000 lm) CIE FLUX CODE
90° 90°
CIE FLUX CODE 94 99 99 100 78 CIE FLUX CODE 72 98 99 100 79
Semipiani C 180° Semipiani C 180°
180.0° 0.0° 180.0° 0.0°
0° SPACING – HEIGHT RATIO 0° SPACING – HEIGHT RATIO
90.0° 270.0°
SHR NOM 2.00 SHR MAX 2.02 SHR MAX TR 2.27 SHR NOM 0.50 SHR MAX 0.73
270° 270°
UTILISATION FACTOR – UF (Floor) Angoli Gamma
UTILISATION FACTOR – UF (Floor)
Angoli Gamma
REFLECTION FACTOR ROOM INDEX REFLECTION FACTOR ROOM INDEX
120 135 150 180 120 135 150 180
Ceiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00 Ceiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00
105 105
0.70 0.50 0.10 0.315 0.353 0.402 0.428 0.456 0.470 0.479 0.70 0.50 0.10 0.588 0.675 0.720 0.766 0.789 0.804
0.30 0.287 0.326 0.380 0.409 0.440 0.457 0.468 0.30 0.543 0.638 0.690 0.743 0.771 0.788
0.10 0.266 0.306 0.362 0.393 0.427 0.446 0.459 0.10 0.509 0.609 0.664 0.723 0.754 0.774
90 90
0.50 0.50 0.10 0.309 0.347 0.395 0.420 0.446 0.460 0.468 0.50 0.50 0.10 0.577 0.662 0.706 0.751 0.773 0.787
0.30 0.284 0.323 0.375 0.403 0.433 0.449 0.460 100
0.30 0.538 0.630 0.680 0.731 0.758 0.775
50
0.10 0.265 0.304 0.359 0.389 0.422 0.440 0.452 0.10 0.507 0.604 0.657 0.714 0.744 0.762
75 75
0.30 0.50 0.10 0.305 0.341 0.387 0.412 0.437 0.451 0.459 0.30 0.50 0.10 0.567 0.650 0.693 0.737 0.758 0.772
100 200
0.30 0.282 0.319 0.370 0.397 0.426 0.442 0.452 0.30 0.532 0.622 0.671 0.720 0.746 0.761
0.10 0.264 0.303 0.356 0.385 0.417 0.434 0.445 0.10 0.504 0.599 0.651 0.705 0.734 0.751
150 60 300
60 0.70 0.50 0.20 0.323 0.365 0.420 0.449 0.482 0.499 0.510 0.70 0.50 0.20 0.607 0.704 0.756 0.811 0.839 0.856
0.30 0.292 0.334 0.393 0.425 0.462 0.483 0.497 0.30 0.556 0.659 0.717 0.780 0.814 0.836
200 0.10 0.269 0.311 0.371 0.406 0.446 0.469 0.484 400 0.10 0.517 0.625 0.686 0.754 0.792 0.817
0.50 0.50 0.20 0.316 0.356 0.408 0.435 0.464 0.480 0.490 0.50 0.50 0.20 0.592 0.683 0.732 0.782 0.808 0.824
cd/klm 0.30 0.288 0.329 0.384 0.415 0.449 0.467 0.479 cd/klm 0.30 0.547 0.646 0.700 0.757 0.788 0.807
30 15 0 30 15 0
0.10 0.267 0.308 0.365 0.398 0.435 0.456 0.469 0.10 0.512 0.615 0.673 0.736 0.770 0.792

CPC 400 + CPL EB400M1


POLAR DIAGRAM NORMAL EFFICIENCY POLAR DIAGRAM NORMAL EFFICIENCY
OF OUTPUT ULOR 0.000 DLOR 0.402 LOR 0.402 OF OUTPUT ULOR 0.000 DLOR 0.825 LOR 0.825

(cd/1000 lm) CIE FLUX CODE (cd/1000 lm) CIE FLUX CODE
90° 90°
CIE FLUX CODE 62 89 97 100 40 CIE FLUX CODE 79 98 99 100 82
Semipiani C 180° Semipiani C 180°
180.0° 0.0°
0° SPACING – HEIGHT RATIO 180.0° 0.0°
0° SPACING – HEIGHT RATIO
90.0° 270.0° SHR NOM 1.50 SHR MAX 1.67 SHR MAX TR 1.86 SHR NOM 1.00 SHR MAX 1.25
270° 270°
UTILISATION FACTOR – UF (Floor) UTILISATION FACTOR – UF (Floor)
Angoli Gamma Angoli Gamma
REFLECTION FACTOR ROOM INDEX REFLECTION FACTOR ROOM INDEX
120 135 150 180 120 135 150 180
Ceiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00 Ceiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00
105 0.70 0.50 0.10 0.283 0.310 0.346 0.365 0.386 0.397 0.404 105 0.70 0.50 0.10 0.664 0.735 0.772 0.810 0.829 0.841
0.30 0.262 0.290 0.329 0.350 0.374 0.387 0.396 0.30 0.627 0.705 0.747 0.791 0.814 0.828
0.10 0.247 0.274 0.315 0.338 0.364 0.379 0.388 0.10 0.599 0.681 0.726 0.774 0.800 0.816
90 0.50 0.50 0.10 0.279 0.305 0.340 0.358 0.378 0.388 0.395 90 0.50 0.50 0.10 0.654 0.724 0.759 0.795 0.813 0.824
0.30 0.260 0.287 0.325 0.346 0.368 0.381 0.389 0.30 0.622 0.697 0.738 0.779 0.800 0.814
50 125
0.10 0.246 0.273 0.313 0.335 0.360 0.373 0.382 0.10 0.596 0.676 0.719 0.765 0.789 0.804
75 75
0.30 0.50 0.10 0.275 0.300 0.334 0.352 0.371 0.381 0.388 0.30 0.50 0.10 0.645 0.712 0.747 0.781 0.799 0.809
100 250
0.30 0.258 0.284 0.321 0.341 0.363 0.374 0.382 0.30 0.616 0.689 0.728 0.768 0.788 0.800
0.10 0.245 0.272 0.310 0.331 0.355 0.368 0.377 0.10 0.593 0.670 0.712 0.755 0.778 0.792
60 150 0.70 0.50 0.20 0.291 0.320 0.361 0.383 0.408 0.421 0.430 60 375 0.70 0.50 0.20 0.686 0.767 0.811 0.857 0.881 0.896
0.30 0.267 0.297 0.340 0.365 0.393 0.409 0.420 0.30 0.642 0.728 0.777 0.830 0.859 0.878
200 0.10 0.250 0.279 0.323 0.349 0.380 0.398 0.410 500 0.10 0.608 0.698 0.750 0.808 0.840 0.861
0.50 0.50 0.20 0.285 0.313 0.351 0.371 0.394 0.406 0.414 0.50 0.50 0.20 0.672 0.747 0.787 0.828 0.850 0.863
cd/klm 0.30 0.264 0.292 0.333 0.356 0.381 0.396 0.405 cd/klm 0.30 0.633 0.714 0.759 0.807 0.832 0.848
30 15 0 0.10 0.248 0.276 0.318 0.342 0.371 0.387 0.397 30 15 0 0.10 0.603 0.687 0.735 0.788 0.817 0.835

CPC 250M EB400M4


POLAR DIAGRAM NORMAL EFFICIENCY POLAR DIAGRAM NORMAL EFFICIENCY
OF OUTPUT ULOR 0.000 DLOR 0.635 LOR 0.635 OF OUTPUT ULOR 0.000 DLOR 0.821 LOR 0.821

(cd/1000 lm) CIE FLUX CODE (cd/1000 lm) CIE FLUX CODE
90° 90°
CIE FLUX CODE 55 91 98 100 63 CIE FLUX CODE 48 95 99 100 82
Semipiani C Semipiani C 180°
180°
180.0° 0.0°
180.0° 0.0°
0° SPACING – HEIGHT RATIO 0° SPACING – HEIGHT RATIO
90.0° 270.0°
SHR NOM 2.00 SHR MAX 2.10 SHR MAX TR 2.31 SHR NOM 1.75 SHR MAX 1.81
270° 270°
UTILISATION FACTOR – UF (Floor) Angoli Gamma
UTILISATION FACTOR – UF (Floor)
Angoli Gamma
REFLECTION FACTOR ROOM INDEX REFLECTION FACTOR ROOM INDEX
120 135 150 180 120 135 150 180
Ceiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00 Ceiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00
105 105
0.70 0.50 0.10 0.514 0.561 0.590 0.619 0.634 0.643 0.70 0.50 0.10 0.612 0.700 0.746 0.792 0.814 0.828
0.30 0.486 0.537 0.570 0.603 0.621 0.632 0.30 0.568 0.665 0.717 0.769 0.796 0.813
0.10 0.464 0.517 0.552 0.589 0.609 0.622 0.10 0.534 0.636 0.691 0.749 0.780 0.799
90 90
0.50 0.50 0.10 0.506 0.552 0.580 0.607 0.621 0.630 0.50 0.50 0.10 0.601 0.688 0.732 0.776 0.798 0.811
0.30 0.482 0.530 0.562 0.593 0.611 0.621 75
0.30 0.562 0.656 0.707 0.756 0.783 0.799
75
0.10 0.462 0.513 0.547 0.582 0.601 0.613 0.10 0.531 0.630 0.685 0.740 0.769 0.787
75 75
0.30 0.50 0.10 0.499 0.543 0.570 0.596 0.610 0.619 0.30 0.50 0.10 0.591 0.675 0.719 0.761 0.783 0.796
150 150
0.30 0.477 0.524 0.555 0.585 0.601 0.611 0.30 0.556 0.648 0.697 0.745 0.770 0.785
0.10 0.459 0.509 0.542 0.575 0.593 0.603 0.10 0.528 0.625 0.678 0.730 0.759 0.775
225 60 225
60 0.70 0.50 0.20 0.531 0.585 0.619 0.655 0.674 0.686 0.70 0.50 0.20 0.633 0.731 0.783 0.837 0.865 0.883
0.30 0.497 0.554 0.593 0.633 0.656 0.670 0.30 0.581 0.686 0.746 0.807 0.841 0.862
300 0.10 0.471 0.530 0.570 0.614 0.640 0.657 300 0.10 0.542 0.652 0.714 0.781 0.819 0.843
0.50 0.50 0.20 0.520 0.570 0.601 0.633 0.649 0.660 0.50 0.50 0.20 0.617 0.710 0.759 0.808 0.834 0.849
cd/klm 0.30 0.490 0.543 0.579 0.615 0.635 0.647 cd/klm 0.30 0.572 0.672 0.728 0.783 0.814 0.832
30 15 0 30 15 0
0.10 0.467 0.522 0.560 0.599 0.622 0.636 0.10 0.537 0.642 0.701 0.762 0.796 0.817

GE Consumer & Industrial 104


Lighting
Photometric data
EB400H1 FGS40S P3
POLAR DIAGRAM NORMAL EFFICIENCY POLAR DIAGRAM NORMAL EFFICIENCY
OF OUTPUT ULOR 0.000 DLOR 0.737 LOR 0.737 OF OUTPUT ULOR 0.000 DLOR 0.726 LOR 0.726

(cd/1000 lm) CIE FLUX CODE (cd/1000 lm) CIE FLUX CODE
90° 90°
CIE FLUX CODE 65 96 99 100 73 CIE FLUX CODE 69 98 99 100 72
Semipiani C 180° Semipiani C 180°
180.0° 0.0°
0° SPACING – HEIGHT RATIO 180.0° 0.0°
0° SPACING – HEIGHT RATIO
SHR NOM 1.25 SHR MAX 1.36 SHR NOM 1.25 SHR MAX 1.47
270° 270°
UTILISATION FACTOR – UF (Floor) UTILISATION FACTOR – UF (Floor)
Angoli Gamma Angoli Gamma
REFLECTION FACTOR ROOM INDEX REFLECTION FACTOR ROOM INDEX
120 135 150 180 120 135 150 180
Ceiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00 Ceiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00
105 105
0.70 0.50 0.10 0.564 0.636 0.674 0.713 0.733 0.745 0.70 0.50 0.10 0.497 0.566 0.636 0.671 0.708 0.726 0.737
0.30 0.526 0.606 0.648 0.693 0.717 0.732 0.30 0.457 0.531 0.607 0.647 0.689 0.711 0.725
0.10 0.497 0.581 0.626 0.676 0.703 0.719 0.10 0.428 0.503 0.584 0.627 0.673 0.698 0.713
90 90
0.50 0.50 0.10 0.554 0.626 0.662 0.699 0.718 0.730 0.50 0.50 0.10 0.489 0.557 0.626 0.659 0.694 0.712 0.722
0.30 0.520 0.598 0.639 0.682 0.705 0.719 0.30 0.453 0.525 0.600 0.639 0.678 0.700 0.712
100 100
0.10 0.494 0.576 0.620 0.668 0.693 0.709 0.10 0.427 0.501 0.580 0.621 0.665 0.688 0.703
75 75
0.30 0.50 0.10 0.545 0.614 0.650 0.686 0.705 0.716 0.30 0.50 0.10 0.482 0.549 0.615 0.648 0.682 0.699 0.709
200 200
0.30 0.515 0.591 0.631 0.672 0.694 0.707 0.30 0.450 0.520 0.593 0.630 0.669 0.689 0.700
0.10 0.491 0.571 0.614 0.659 0.684 0.698 0.10 0.425 0.498 0.575 0.615 0.657 0.679 0.692
60 300 0.70 0.50 0.20 0.582 0.664 0.707 0.755 0.779 0.794 60 300 0.70 0.50 0.20 0.510 0.585 0.664 0.704 0.749 0.771 0.785
0.30 0.538 0.625 0.674 0.728 0.757 0.776 0.30 0.465 0.543 0.627 0.673 0.724 0.751 0.769
400 0.10 0.504 0.596 0.647 0.705 0.738 0.760 400 0.10 0.432 0.511 0.599 0.647 0.703 0.733 0.753
0.50 0.50 0.20 0.568 0.646 0.686 0.728 0.750 0.764 0.50 0.50 0.20 0.500 0.572 0.646 0.683 0.723 0.744 0.756
cd/klm 0.30 0.530 0.613 0.658 0.707 0.733 0.749 cd/klm 0.30 0.459 0.535 0.615 0.657 0.703 0.727 0.742
30 15 0 0.10 0.500 0.586 0.634 0.688 0.718 0.736 30 15 0 0.10 0.430 0.507 0.590 0.635 0.685 0.713 0.730

EB400H4 VBSD40S
POLAR DIAGRAM NORMAL EFFICIENCY POLAR DIAGRAM NORMAL EFFICIENCY
OF OUTPUT ULOR 0.000 DLOR 0.761 LOR 0.761 OF OUTPUT ULOR 0.000 DLOR 0.835 LOR 0.835

(cd/1000 lm) CIE FLUX CODE (cd/1000 lm) CIE FLUX CODE
90° 90°
CIE FLUX CODE 46 88 99 100 76 CIE FLUX CODE 51 85 95 100 83
Semipiani C 180° Semipiani C 180°
180.0° 0.0°
0° SPACING – HEIGHT RATIO 180.0° 0.0°
0° SPACING – HEIGHT RATIO
SHR NOM 1.75 SHR MAX 1.84 SHR NOM 1.50 SHR MAX 1.64
270° 270°
UTILISATION FACTOR – UF (Floor) UTILISATION FACTOR – UF (Floor)
Angoli Gamma Angoli Gamma
REFLECTION FACTOR ROOM INDEX REFLECTION FACTOR ROOM INDEX
120 135 150 180 120 135 150 180
Ceiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00 Ceiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00
105 0.70 0.50 0.10 0.537 0.625 0.672 0.719 0.744 0.759 105 0.70 0.50 0.10 0.512 0.580 0.673 0.721 0.774 0.801 0.818
0.30 0.491 0.587 0.640 0.695 0.724 0.742 0.30 0.459 0.528 0.629 0.683 0.743 0.776 0.797
0.10 0.455 0.556 0.613 0.674 0.707 0.727 0.10 0.420 0.489 0.593 0.651 0.717 0.753 0.777
90 90
0.50 0.50 0.10 0.526 0.612 0.658 0.704 0.728 0.742 0.50 0.50 0.10 0.502 0.568 0.659 0.706 0.756 0.783 0.800
0.30 0.485 0.579 0.631 0.683 0.712 0.729 0.30 0.454 0.522 0.620 0.673 0.730 0.762 0.783
50 75
0.10 0.453 0.552 0.607 0.665 0.697 0.716 0.10 0.419 0.486 0.588 0.644 0.708 0.743 0.766
75 75
0.30 0.50 0.10 0.516 0.600 0.645 0.690 0.714 0.728 0.30 0.50 0.10 0.493 0.557 0.645 0.691 0.740 0.766 0.783
100 150
0.30 0.479 0.571 0.622 0.673 0.700 0.716 0.30 0.450 0.516 0.611 0.663 0.718 0.749 0.768
0.10 0.450 0.547 0.601 0.657 0.688 0.705 0.10 0.417 0.483 0.583 0.638 0.698 0.732 0.754
60 150 0.70 0.50 0.20 0.554 0.652 0.705 0.761 0.790 0.809 60 225 0.70 0.50 0.20 0.526 0.599 0.702 0.757 0.818 0.851 0.872
0.30 0.502 0.606 0.666 0.730 0.765 0.787 0.30 0.467 0.541 0.649 0.711 0.780 0.819 0.845
200 0.10 0.463 0.570 0.634 0.703 0.743 0.768 300 0.10 0.424 0.496 0.609 0.673 0.748 0.792 0.821
0.50 0.50 0.20 0.540 0.632 0.682 0.733 0.761 0.777 0.50 0.50 0.20 0.514 0.583 0.680 0.731 0.788 0.818 0.838
cd/klm 0.30 0.493 0.593 0.649 0.708 0.740 0.759 cd/klm 0.30 0.460 0.531 0.635 0.693 0.756 0.792 0.815
30 15 0 0.10 0.458 0.561 0.621 0.685 0.722 0.744 30 15 0 0.10 0.421 0.492 0.599 0.659 0.729 0.769 0.795

EB400S1 L4MD40S
POLAR DIAGRAM NORMAL EFFICIENCY POLAR DIAGRAM NORMAL EFFICIENCY
OF OUTPUT ULOR 0.000 DLOR 0.825 LOR 0.825 OF OUTPUT ULOR 0.000 DLOR 0.689 LOR 0.689

(cd/1000 lm) CIE FLUX CODE (cd/1000 lm) CIE FLUX CODE
90° 90°
CIE FLUX CODE 79 98 99 100 82 CIE FLUX CODE 38 77 94 100 68
Semipiani C 180° Semipiani C 180°
180.0° 0.0° 180.0° 0.0°
0° SPACING – HEIGHT RATIO 0° SPACING – HEIGHT RATIO
SHR NOM 1.00 SHR MAX 1.25 SHR NOM 2.00 SHR MAX 2.06
270° 270°

Angoli Gamma
UTILISATION FACTOR – UF (Floor) Angoli Gamma
UTILISATION FACTOR – UF (Floor)
REFLECTION FACTOR ROOM INDEX REFLECTION FACTOR ROOM INDEX
120 135 150 180 120 135 150 180
Ceiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00 Ceiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00
105 105
0.70 0.50 0.10 0.664 0.735 0.772 0.810 0.829 0.841 0.70 0.50 0.10 0.358 0.420 0.511 0.560 0.614 0.642 0.660
0.30 0.627 0.705 0.747 0.791 0.814 0.828 0.30 0.305 0.368 0.466 0.521 0.583 0.617 0.639
0.10 0.599 0.681 0.726 0.774 0.800 0.816 0.10 0.267 0.328 0.430 0.488 0.556 0.594 0.619
90 90
0.50 0.50 0.10 0.654 0.724 0.759 0.795 0.813 0.824 0.50 0.50 0.10 0.348 0.408 0.498 0.545 0.598 0.626 0.644
125 0.30 0.622 0.697 0.738 0.779 0.800 0.814 40
0.30 0.301 0.362 0.458 0.512 0.572 0.605 0.627
0.10 0.596 0.676 0.719 0.765 0.789 0.804 0.10 0.265 0.326 0.426 0.482 0.548 0.585 0.609
75 75
0.30 0.50 0.10 0.645 0.712 0.747 0.781 0.799 0.809 0.30 0.50 0.10 0.340 0.398 0.485 0.532 0.584 0.612 0.630
250 80
0.30 0.616 0.689 0.728 0.768 0.788 0.800 0.30 0.297 0.356 0.450 0.503 0.561 0.594 0.614
0.10 0.593 0.670 0.712 0.755 0.778 0.792 0.10 0.264 0.324 0.422 0.477 0.541 0.577 0.600
60 375 60 120
0.70 0.50 0.20 0.686 0.767 0.811 0.857 0.881 0.896 0.70 0.50 0.20 0.367 0.434 0.533 0.587 0.649 0.682 0.704
0.30 0.642 0.728 0.777 0.830 0.859 0.878 0.30 0.310 0.376 0.481 0.542 0.612 0.651 0.678
500 0.10 0.608 0.698 0.750 0.808 0.840 0.861 160 0.10 0.269 0.333 0.441 0.504 0.580 0.624 0.654
0.50 0.50 0.20 0.672 0.747 0.787 0.828 0.850 0.863 0.50 0.50 0.20 0.356 0.419 0.513 0.565 0.623 0.654 0.675
cd/klm 0.30 0.633 0.714 0.759 0.807 0.832 0.848 cd/klm 0.30 0.305 0.368 0.469 0.527 0.592 0.629 0.653
30 15 0 30 15 0
0.10 0.603 0.687 0.735 0.788 0.817 0.835 0.10 0.267 0.330 0.434 0.494 0.565 0.606 0.633

EB400S4 C4S40S
POLAR DIAGRAM NORMAL EFFICIENCY POLAR DIAGRAM NORMAL EFFICIENCY
OF OUTPUT ULOR 0.000 DLOR 0.821 LOR 0.821 OF OUTPUT ULOR 0.000 DLOR 0.750 LOR 0.750

(cd/1000 lm) CIE FLUX CODE (cd/1000 lm) CIE FLUX CODE
90° 90°
CIE FLUX CODE 48 95 99 100 82 CIE FLUX CODE 36 77 95 100 75
Semipiani C 180° Semipiani C 180°
180.0° 0.0°
0° SPACING – HEIGHT RATIO 180.0° 0.0°
0° SPACING – HEIGHT RATIO
SHR NOM 1.75 SHR MAX 1.81 SHR NOM 2.25 SHR MAX 2.38
270° 270°

Angoli Gamma
UTILISATION FACTOR – UF (Floor) UTILISATION FACTOR – UF (Floor)
Angoli Gamma
REFLECTION FACTOR ROOM INDEX REFLECTION FACTOR ROOM INDEX
120 135 150 180 120 135 150 180
Ceiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00 Ceiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00
105 105
0.70 0.50 0.10 0.612 0.700 0.746 0.792 0.814 0.828 0.70 0.50 0.10 0.376 0.446 0.550 0.606 0.667 0.699 0.719
0.30 0.568 0.665 0.717 0.769 0.796 0.813 0.30 0.317 0.388 0.501 0.563 0.634 0.672 0.696
0.10 0.534 0.636 0.691 0.749 0.780 0.799 0.10 0.274 0.343 0.461 0.528 0.604 0.647 0.675
90 90
0.50 0.50 0.10 0.601 0.688 0.732 0.776 0.798 0.811 0.50 0.50 0.10 0.365 0.434 0.536 0.591 0.651 0.682 0.702
75 0.30 0.562 0.656 0.707 0.756 0.783 0.799 0.30 0.312 0.382 0.493 0.554 0.621 0.659 0.683
40
0.10 0.531 0.630 0.685 0.740 0.769 0.787 0.10 0.272 0.341 0.457 0.522 0.596 0.638 0.665
75 75
0.30 0.50 0.10 0.591 0.675 0.719 0.761 0.783 0.796 0.30 0.50 0.10 0.356 0.422 0.522 0.576 0.635 0.666 0.686
150 80
0.30 0.556 0.648 0.697 0.745 0.770 0.785 0.30 0.307 0.375 0.484 0.544 0.610 0.647 0.670
0.10 0.528 0.625 0.678 0.730 0.759 0.775 0.10 0.271 0.339 0.452 0.516 0.588 0.629 0.654
60 225 120 0.70 0.50 0.20 0.386 0.461 0.574 0.636 0.706 0.743 0.767
0.70 0.50 0.20 0.633 0.731 0.783 0.837 0.865 0.883 60
0.30 0.581 0.686 0.746 0.807 0.841 0.862 0.30 0.322 0.397 0.517 0.586 0.665 0.709 0.739
300 0.10 0.542 0.652 0.714 0.781 0.819 0.843 160 0.10 0.276 0.349 0.473 0.545 0.631 0.680 0.713
0.50 0.50 0.20 0.617 0.710 0.759 0.808 0.834 0.849 0.50 0.50 0.20 0.373 0.445 0.553 0.612 0.677 0.713 0.735
cd/klm 0.30 0.572 0.672 0.728 0.783 0.814 0.832 cd/klm 0.30 0.316 0.388 0.505 0.570 0.644 0.685 0.711
30 15 0 30 15 0
0.10 0.537 0.642 0.701 0.762 0.796 0.817 0.10 0.274 0.345 0.465 0.534 0.614 0.660 0.690

GE Consumer & Industrial 105