Bulletin A-351A

Bell & Gossett

Designed for Closed Hydronic Heating and Cooling Systems

ASME Expansion Tanks


Series B-LA Bladder Tanks
Increases System Performance Reduces Oxygen Corrosion Prevents Waterlogging Replaceable Bladder Meets ASME Section VIII, Division 1 Standards 125 PSI Working Pressure Standard High Maximum Operating Temperature 240F Seismic Restraints Available Sight Glass Available

Series B-LA Bladder Tanks


DESCRIPTION
Series B-LA expansion tanks are ASME rated pre-charged bladder-type pressure vessels. The Series B-LA tank is designed to absorb the expansion forces of heating/cooling system water while maintaining proper system pressurization under varying operating conditions. The heavy duty bladder contains system water thereby eliminating tank corrosion and waterlogging problems. Dimensions: Gallons (Ltrs.), Inches (mm), Weights: LBS. (KG) PART MODEL NUMBER NUMBER 116782 116783 116784 116785 116786 116787 116788 116789 116790 116791 116792 B-35LA B-50LA B-85LA B-100LA B-130LA B-165LA B-200LA B-300LA B-400LA B-500LA B-600LA TANK VOLUME 10 (38) 13 (50) 22 (85) 26 (100) 34 (130) 44 (165) 53 (200) 80 (300) 106 (400) 132 (500) 158 (600) ACCEPTANCE VOLUME 10 (38) 11 (40) A 10 (254) 12 (305) 16 (406) 20 (508) 27 (100) 24 (610) 53 (200) 30 (762) B 375/16 (948) 371/16 (941) 345/16 (872) 39 (991) 3411/16 (881) 3911/16 (1008) 407/8 (1039) 56 (1423) 685/8 (1743) 821/2 (2096) 67 (1702) C D APPROX. SHPG. WT. 65 (29) 72 (33) 88 (40) 94 (43) 130 (59) 140 (63) 192 (87) 230 (104) 274 (124) 308 (140) 442 (200) APPROX. WT. 100% FULL* 144 (67) 164 (74) 270 (122) 308 (140) 410 (186) 503 (228) 629 (285) 890 (404) 1148 (521) 1397 (634) 1745 (791)

OPERATING DATA
Maximum working pressure . . . . . . . . . . . . . 125 PSI (862kPa) Maximum operating temperature . . . . . . . . . 240F (115C)

MATERIALS OF CONSTRUCTION
System Connection: Forged Steel Shell: Carbon Steel Bladder: Heavy Duty Butyl Rubber Designed and Constructed per ASME Section VIII, Division 1

3/4

Dimensions subject to change. Not to be used for construction purposes Refer to submittals for optional seismic restraints.

*Approximate weight 100% full occurs if bag fails or if air charge is lost.

TYPICAL HYDRONIC HEATING/COOLING APPLICATION


B&G Model107 A High Capacity Air Vent B & G Pressure Reducing Valve with Check

Cold Water Fill

A
From Boiler or HX B & G Triple Duty Valve B & G Rolairtrol Air Separator B & G #7 Pressure or #87 Gage Air Vent

CHARGING VALVE .302" 32NC

LIFTING RING MODELS B-35P TO B-600P

e at rn te Al

To System

B&G Suction Diffuser Pre-Charging Air Connection Lock-Shield Valve

B & G System Pump

B & G Pressured Expansion Tank (Series B or Series D-Vertical) See Table A for Pipe Sizing

SYSTEM CONNECTION (C)

DRAIN (D)

NOTE: Tanks are factory pre-charged at 12 PSI (83kPa).

Drain Valve

Figure A B&G Model 107A High Capacity Air Vent with Rolairtrol Air Separator and Series B or D Vertical Pressurized Expansion Tank

COPYRIGHT 2007 BY ITT CORPORATION PRINTED IN U.S.A. 6-07


THE ITT ENGINEERED BLOCKS SYMBOL AND ENGINEERED FOR LIFE ARE REGISTERED TRADEMARKS OF ITT CORPORATION

ITT 8200 N. Austin Avenue Morton Grove, IL 60053 Phone: (847) 966-3700 Fax: (847) 966-9052 www.bellgossett.com