You are on page 1of 1

06 Electrical power supply and utilization (scientific, technical)

many advantages, such as excellent performance and enhanced safety. a cogeneration plant is operating in parallel. In this paper, a sample
The performance improvement is achieved because of strong mechan- distribution feeder with a cogeneration plant connected at its end was
ical integrity (cycle life) and absence of binder (shelf life) in C-C simulated. The effects of the cogeneration plant on the voltage
composite. The enhancement in safety comes from high thermal imbalances, current imbalances, and system loss of the specific
conductivity, fire retardant characteristics and an acceptable ability to distribution feeder were evaluated based on the simulation results.
overcharge and overdischarge. The simulation results and conclusion are of value to distribution
engineers for planning and operating such a system.
02/01485 Coal utilization and dust collection technology.
(Part 2). High temperature duet collection technology on new 02/01491 Electric power units operating on solid oxide
type high efficiency power generation fuels cells. Results and prospects
Makino, H. Funtai Kogaku Kaishi, 2001, 38, (9), 652-658. (In Japanese) Dudnik, O.M. et al. Energy. Elektrif. (Kiev), 2001, 4, 27--44. (In
A review on power generation by combustion of coals using gas Ukrainian)
turbines, fuel cells. High dust collection technology is an important A review with refs. on the world-wide achievements in developing new
factor in promoting these methods. hybrid cogeneration power plants operating on solid oxide fuels cells
(SOFCs) with 1 MW electric power. A brief description of the main
02/01486 Contingency rankingfor voltage collapse using structural and operating characteristics of contemporary SOFCs and
parallel self-organizing hierarchical neural network their advantages is given along with measures for a further increase of
Pandit, M. et al. Electrical Power and Energy Systems, 2001, 23, (5), their electricity efficiency. The effectiveness of integrating of high-rpm
369-379. gas turbine units in the SOFC-based power plants in Germany and
On-line monitoring of the power system voltage security has become a USA for increasing the electricity efficiency is demonstrated. The
vital factor electric utilities. This paper proposes a voltage contingency method of the calculation of the hybrid SOFC-based power plants is
ranking approach based on parallel self-organizing hierarchical neural introduced. The design of a new ecologically pure SOFC-based plant
network (PSHNN). Loadability margin to voltage collapse following a employing the technology of gasification of Ukrainian high-ash coal in
contingency has been used to rank the contingencies. PSHNN is a a circulating fluidized bed under pressure is developed with the
multi-stage neural network where the stages operate in parallel rather prospect of 500 kW power under appropriate conditions.
than in series during testing. The number of ANNs required is
drastically reduced by adopting a clustering technique to group
contingencies of similar severity into one cluster. Entropy based 02/01492 Electrochemical power sources for unmanned
feature selection has been employed to reduce the dimensionality of underwater vehicles used in deep sea survey operations
the ANN. Once trained, the proposed ANN model is capable of Hasvold, ~. and Stcrkersen, N. Journal o[Power Sources, 2001, 96, (1),
ranking the voltage contingencies under varying load conditions, on 252-258.
line. The effectiveness of the proposed method has been demonstrated A comparison of available energy from different power sources for
by applying it for contingency ranking of IEEE 30-bus system and a unmanned underwater vehicles, discharged at atmospheric pressure or
practical 75-bus Indian system. at ambient pressure, has been undertaken. The basis for the
comparison has been a neutrally buoyant power source with a total
volume of 300 lires. For deep diving vehicles, the use of batteries that
02/01487 CO2 conversion system and economic evaluation can operate at ambient pressure is advantageous. This advantage
Niwa, S. C02 Koteika, Kakuri no Saishin Gijutsu, 2000, 247-259. (In increases as the mean density of the battery decreases and as the mean
Japanese) Edited by Inui T. density of the pressure hull increases. A fuel cell using spherical gas
Conceptual design of natural-energy-based power generation systems is containers is also an attractive power source for deep diving survey
described, in which CO2 from coal-fired power plants is liquefied and underwater vehicles.
hydrogenated to form MeOH for power generation systems. H2 needed
for the above MeOH synthesis process is produced by water electrolysis
with power supply from natural energy power generation systems using 02/01493 Evolution of power sources for implantable
hydraulic or solar power. The system's economic feasibility is cardioverter defibrillators
evaluated. Crespi, A.M. et al. Journal of Power Sources, 2001, 96, (1), 33-38.
The evolution of seven generations of power sources for implantable
cardioverter defibrillators (ICD) is presented. The packaging efficiency
02/01488 Direct methanol-air fuel cells with membranes of the power sources has steadily increased, resulting in smaller, lighter
plus circulating electrolyte batteries while maintaining the required electrical characteristics. The
Kordesch, K. et al. Journal of Power Sources, 2001, 96, (1), 200-203.
A new approach for direct methanol-air fuel cells (DMFC), with the main areas for improvement were reduction of headspace volume,
advantage of reduced crossover is discussed in this paper. Methanol reduction of separator volume, and a change from a two-cell battery to
a single cell.
traces in the circulated electrolyte are recovered and COz bubbles in
the cells are removed due to the forced methanol-electrolyte stream
through the cell. Degradation of the catalyst is reduced since fuel cell 02/01494 Experimental study on the dynamic
electrodes degrade on activated stand without load to a higher extent characteristics of kW-scale molten carbonate fuel cell
than under load because high voltage on open circuit promotes carbon systems
oxidation, catalyst changes, etc. Therefore, life expectancy increases Kang, B.S. et al. Journal of Power Sources, 2001, 94, (1), 51-62.
with circulating electrolyte by removing the electrolyte from the cells The aim of this work is to develop dynamic models for two types of kW-
between operating periods. scale molten carbonate fuel cell (MCFC) systems of the basis of
experimental data. the dynamic models are represented as a 3 x 3
02/01489 Distributed generation: a definition transfer function matrix for a multi-input and multi-output (MIMO)
Ackermann, T. et al. Electric Power Systems Research, 2001, 57, (3), system with three inputs and three outputs. The three controlled
195-204. variables which severely affect the stack performance and lifetime are
Distributed generation (DG) is expected to become more important in the temperature difference in the stack and the pressure drop at the
the future g.eneration system. The current literature, however, does not anode and the cathode. Three manipulated variables, namely, current
use a cons:stent definition of DG. This paper discusses the relevant load, fuel and oxidant utilization, are selected to keep the three
issues and aims at providing a general definition for distributed power controlled variables within their safety limits for the reliable operation
generation in competitive electricity markets. In general, DG can be and protection of the system in case of emergency. Each element in the
defined as electric power generation within distribution networks or on transfer function matrix is in the form of a first-order model using a
the customer side of the network. In addition, the terms distributed simple, unit step, response test during operation. The non-zero off-
resources, distributed capacity and distributed utility are discussed. diagonal elements in the transfer function matrix show that some
Network and connection issues of distributed generation are presented, interactions exist among the operating variables, and two zeros show no
tOO. interaction between fuel and oxidant flow without gas cross-over. The
stability of both dynamic models is analysed using the relative gain
array (RGA) method. Large diagonal elements in the RGA matrix
02/01490 Effects of a cogeneration plant on the system show that the pairing between the manipulated and controlled variable
imbalance of a distribution feeder connected with It is appropriate. Proper pairing is also proven by the singular value
Chen, T. and Yang, W. Electrical Power and Energy Systems, 2001, 23, analysis (SVA) method with a smaller singular value in each system.
(5), 381-388.
This paper has evaluated the effects of a cogeneration plant on the
system imbalances of a radial three-phase four-wire distribution feeder 02/01495 Highly efficient electricity generation through a
connected with it. A three-phase four-wire distribution feeder is often hybrid molten carbonate fuel cell-closed loop gas turbine
operated under unbalanced circumstances by reason of unequal plant
individual phase loads. The degree of voltage and current imbalances Lunghi, P. et al. Energy Conversion and Management, 2001, 42, (14),
in a three-phase four-wire feeder might be significantly enlarged while 1657-1672.

Fuel and Energy Abstracts May 2002 191

You might also like