The Introducing of 1.

The drawing of principle is as following:

Grid Tie

Controller

2. Introducing: A. The control system compose by the PWM controller, PWM dump load and the AC dump load. B. Normally the PWM dump load and the AC dump load do not work. C. We can set up the voltage of the PWM dump load and the AC dump load. D. Now we can description the process of controller working a. For example we set up the PWM dump load voltage is 430v and the AC dump load voltage is 450V, these two voltage is different and the AC dump load voltage must higher the PWM dump load voltage. b. Normally the controller output to the grid tie inverter, when the output voltage of controller is higher 430V , then the redundant power is dumped by PWM dump load, but in this time the output voltage of controller still exist, that mean the grid tie inverter can still working. Like these, the output controller is stable at 430v. c. When the PWM dump load is working, in fact there two load for the wind turbine, one is the inverter and the other is the dump load. d. During the inverter and PWM controller is working, the voltage is still high 430V, Then switch to the AC dump load by the relay. e. After 20 minutes (called by the relay time), the controller check the voltage and regain restart the controller according the normal working state. f. And there is a switch, that you can restart the controller at anytime. g. When the grid power turn off , the AC dump load working, there are not output of controller. h. When you need to stop wind turbine, you can use the manual mechanical brake i. In the other way, The above description is without the furl tail function, When the wind speed is more, the tail can furl and then the blade deflexion a angle with the wind direction, the blade do not face the wind direction vertical. j. Last testing, the PWM dump laod is 5KW and the AC load is also 5kw, Next time we will change to 7.5KW and 10KW There are three parameter can setup according your requipment: 1. The PWM dump load voltage 2. The AC dump load voltage(Usully higher 15-20V than the PWM dump load voltage) 3. The relay time

The Description of the switch of Grid tie controller

1WIND TURBINE SWITCH A ON The wind turbine controller is working state, this is the normal state; B OFF, The AC dump load working 2: Grid Power Switch: A: ON, The Normal working state; B: OFF, Turn off the Grid power, the AC dump load working. 3: Cancel the time relaying: When the controller is time relaying, you can push this button so that cancel the time relaying. NOTICE: 1. The PWM dump load use the two cable wire to connect to the controller terminal with the PWM dump load terminal; 2. The AC dump load use the three cable wire to connect to the controller terminal with the AC dump load terminal;

The Picture Of the Grid Tie Controller

You might also like