LEGEND
(A): (B): (C): (D): (E): (F), (G): (H): Internal Diameter (L*I) in meters Revision Index (I): Height between tangent lines in meters Item (J): Material: CS or LTCS + CA mm (Corrosion Allowance), Designation of the Item Number of items SS, 316L, 304L, TI (Titanium), AL (Aluminum) Total number of equipment (K): Design pressure (Barg) Suction / Discharge for pumps Main and Second Criteria per piece Shell / Tube for exchangers If necessary, value will be given as follow: x*value per piece 3 In / Bottom or Out / Top Design Flowrate (m /h) Rated Installed Power (kw) (L): Design temperature Exchanger Surface Area (m 2) Same as point (k) Duty (kw) (M): Type 3 Volume (m ) H: Horizontal or V: Vertical T: Turbine, M: Motor or D: Diesel, P: Pneumatic Bare tube area (m2); only for areorefrigerant Centrifugal Pump Head at rated capacity (m) Centrifugal (C), Dosing (Dos) for dosing pumps Reciprocating / Dosing Pump Differential Pressure (bar) Exchanger Type(TEMA) Others: trays type (valve, random) (N): Design case for exchangers S: summer case W: winter case PW: winter-packed sealine case Power Pe: estimated absorbed
shaft power
Pi: installed power
NOTES
1) Steam out to be considered:150C/ATM 2) Full Vacuum to be considered at the temperature of 5C 3) By mechanical department 4) To be finalized during detail engineering. 5) Flow rate to be confirmed based on corrosion inhibitor requirement.
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 3 of 6
ITEM LIST
Phase 15 Phase 16
100-A-101 100-D-101 100-D-102 100-D-103 100-D-104 100-DH-103 100-E-101 100-P-101 100-P-102 A/B 100-P-103 A/B 100-P-104 A/B/C 100-X-101 100-U-101
100-D-105 100-P-105
LP Steam Condenser High Pressure Separator High Pressure Separator Sump Drum Steam Condensate Surge Drum Sump Drum Heater Gas Heater Sump Pump Steam Condensate Pumps Slug Catcher MEG Injection Pumps HP Separator MEG Injection Pumps Slug Catcher Methanol Injection Package
Methanol Storage Drum Methanol Injection Pump
100-A-201 100-D-201 100-D-202 100-D-203 100-D-204 100-DH-203 100-E-201 100-P-201 100-P-202 A/B 100-P-203 A/B 100-P-204 A/B/C 100-X-201 100-U-201
100-D-205 100-P-205
LP Steam Condenser High Pressure Separator High Pressure Separator Sump Drum Steam Condensate Surge Drum Sump Drum Heater Gas Heater Sump Pump Steam Condensate Pumps Slug Catcher MEG Injection Pumps HP Separator MEG Injection Pumps Slug Catcher Methanol Injection Package
Methanol Storage Drum Methanol Injection Pump
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 4 of 6
Class: 1
REV.
ITEM
(A) 1
(B) 100-A-101
( C) LP Steam Condenser
(D) 1
(E) 2
(F) 2141kW
( G) 68.6 m
1 1 1 1 1
High Pressure Separator High Pressure Separator Sump Drum Steam Condensate Surge Drum Methanol Storage Drum
1 1 1 1 1
2 2 2 2 2
LTCS + SS clad (TP 321) LTCS + SS clad (TP 321) SS (AISI 304 L) CS+3 mm CS+3 mm
V V H H V Included in 100-U-101
100-DH-103
Electric Heater
Included in 100-D-103
100-E-101
Gas Heater
19900 kW
201.6 m
CS + 3 mm
SS 304L
8 (2)
82 (2)
270
-46/85 (1)
BEM
Design case: PW - W
100-P-101
Sump Pump Steam Condensate Pumps Slug Catcher MEG Injection Pumps HP Separator MEG Injection Pumps Methanol Injection Pump
15 m/h
96 m
(3)
(3)
25
55
Centr. Vertical Submerged Centri. Hrizontal Reciprocatin g / Dosing Reciprocatin g / Dosing Reciprocatin g / Dosing
Pe=6.1 kW
1 1
2 2
4 4
(3) (3)
(3) (3)
11.5 136
135 85
1 m/h
(3)
(3)
102.3
85
Pe: by vendor
1.5 m/h
90
85
included in 100-U-101
100-X-101
Slug Catcher
2000 m
646"
CS+3 mm
139
-29/85
Finger
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 5 of 6
Class: 1
REV.
ITEM
DESIGNATION OF ITEM
No of ITEM
No of Equi. Total
Main CRITERIA
Second CRITERIA
(A) 1
(B) 100-U-101
(D) 1
(E) 2
(F)
( G)
(M)
(N)
-one Methanol Storage Drum (100-D-105) -one Methanol Injection Pump (100-P-105)
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 6 of 6
LP Steam Condenser MEG Sump Drum Rich MEG Flash Drums Steam Condensate Surge Drum Lean MEG Filters Lean MEG Feed Filter MEG Injection Pumps Lean MEG Booster Pumps MEG Sump Pump Rich MEG Pumps Steam Condensate Pumps Lean MEG Feed Pump Lean MEG Storage Tanks Rich MEG Storage Tanks
PH Control Package Storage tank Injection pumps
102-U-101
102-A-101 102-C-101 102-D-101 102-D-102 102-D-103 102-E-101 102-F-101 A/B 102-F-102 102-P-101 102-P-107
102-U-201
102-A-201 102-C-201 102-D-201 102-D-202 102-D-203 102-E-201 102-F-201 A/B 102-F-202 102-P-201 102-P-207
102-U-103
102-T-104 102-P-111 A/B/C/D/E/F
102-U-104
102-T-105 102-P-112 A/B/C/D/E/F
Antifoam Package
Storage tank Injection pumps
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 4 of 8
ITEM LIST
102-U-301
102-A-301 102-C-301 102-D-301 102-D-302 102-D-303 102-E-301 102-F-301 A/B 102-F-302 102-P-301 102-P-307
102-U-501
102-A-501 102-C-501 102-D-501 102-D-502 102-D-503 102-E-501 102-F-501 A/B 102-F-502 102-P-501 102-P-507
102-U-401
102-A-401 102-C-401 102-D-401 102-D-402 102-D-403 102-E-401 102-F-401 A/B 102-F-402 102-P-401 102-P-407
102-U-601
102-A-601 102-C-601 102-D-601 102-D-602 102-D-603 102-E-601 102-F-601 A/B 102-F-602 102-P-601 102-P-607
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 5 of 8
Class: 1
REV.
ITEM
(A) 0
(B) 102-A-101
(D) 1
(E) 6
(F)
( G)
(M)
102-A-102
4090 kW
CS + 3 mm
2 (2)
135 (1)
Air Cooler
102-C-101
Still column
102-D-101
Included in 102-U-101 - 601 Included in 102-U-101 - 601 Included in 102-U-101 - 601 28.1 m 2.25 6.3 CS + Coating + 3 mm 3.5 (2) 155 (1) H
102-D-102
Glycol reboiler
102-D-103
Reflux drum
102-D-105
102-D-106 A/B
13.6 m
1.85
4.45
CS + 3 mm
3.5 (2)
85 (1)
102-D-107
19.1 m
5.4
CS + 3 mm
2 (2)
135 (1)
102-E-101
0 0 0
2 1 2
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 6 of 8
Class: 1
REV.
ITEM
(A) 0
(B) 102-F-104
(D) 1
(E) 1
(F) 5 m/h
( G)
(M) Cartridge
(N)
Reflux pump
6 22 m/h DP= 210.3 bar 41.6 m 234 85 Reciprocating / Dosing Centrifugal Centr. Vertical Submerged Centrifugal Centrifugal
MEG Injection Pumps Lean MEG Booster Pumps MEG Sump Pump
44 m/h
(3)
(3)
6.5
85
Pe= 9.1 kW
102-P-104
15 m/h
54.2 m
(3)
(3)
9.2
155
Pe= 3.9 kW
0 0
2 2
2 2
80 m/h 70 m/h
187 m 48.4 m
(3) (3)
(3) (3)
24.8 7.93
85 135
102-P-107
102-P-109 A/B
Injection pumps
102-T-101 A/B
12
11
CS + 1.5 mm
85
Fixed roof
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 7 of 8
Class: 1
REV.
ITEM
(A) 0
(D) 2
(E) 2
( G)
(N)
102-T-103
Included in 102-U-102
102-T-104
Storage tank
Included in 102-U-103
102-T-105
Storage tank
Included in 102-U-104
102-U-101
MEG Regeneration Package PH Control Package Corrosion Inhibitor Package Antifoam Package
Total capacity: 73047 Kg/h. MEG: 27758 Kg/h, water: 45289 Kg/h. 6 identical MEG regeneration packages are provided: 4x25% packages normally operating and 2 stand-by packages. Total capacity: 3.0 m3 /h.This package contains: one storage tank (102-T-103), two Injection pumps (102-P-109 A/B).
102-U-102
102-U-103
Total capacity: 6.0 l/h. (6) This package contains: one storage tank (102-T-104), six identical Injection pumps (102-P-111 A/B/C/D/E/F).
102-U-104
Total capacity: 60 l/h. (7) This package contains: one storage tank (102-T-105), six identical Injection pumps (102-P-112 A/B/C/D/E/F).
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 8 of 8
ITEM LIST
Phase 15
103-A-101 103-A-102 103-A-103 103-A-104 103-C-101 103-D-101 103-D-102 103-D-103 103-D-105 103-D-106 103-D-107 103-D-108 103-D-109 103-D-110 103-DH-108 103-E-101 A/B 103-E-102 103-E-103 103-E-104
Stabilized Condensate Air Cooler First Stage Offgas Compressor Aftercooler Second Stage Offgas Compressor Aftercooler Stabilizer Reflux Condenser Condensate Stabiliser Preflash Drum First Stage Offgas Compressor Suction Drum Second Stage Offgas Compressor Suction Condensate Desalter Condensate Degassing Drum Stabiliser Reflux Drum Sump Drum HP Steam Condensate Flash Drum First Stage Offgas Compressor Discharge Sump Drum Heater Condensate Preflash Heaters Condensate Desalter Preheater Stabilizer Reboiler Stabilizer Side Reboiler
103-F-101A/B 103-K-101 103-P-101 A/B 103-P-102 A/B 103-P-103 A/B 103-P-104 103-P-105 A/B 103-P-108 103-U-101
103-P-106 A/B 103-T-101
Glycolated Water Filters First Stage & Second Stage Offgas Compressor Desalter Feed Pumps Stabilizer Reflux Pumps Stabilized Condensate Export Pumps Sump Drum Pump Steam Condensate Pumps Condensate Recycle Pump Demulsifier Package
Demulsifier Injection pumps Demulsifier Storage tank
103-U-102
103-P-107 A/B/C/D/E 103-T-102
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 4 of 8
ITEM LIST
Phase 16
103-A-201 103-A-202 103-A-203 103-A-204 103-C-201 103-D-201 103-D-202 103-D-203 103-D-205 103-D-206 103-D-207 103-D-208 103-D-209 103-D-210 103-DH-208 103-E-201 A/B 103-E-202 103-E-203 103-E-204
Stabilized Condensate Air Cooler First Stage Offgas Compressor Aftercooler Second Stage Offgas Compressor Aftercooler Stabilizer Reflux Condenser Condensate Stabiliser Preflash Drum First Stage Offgas Compressor Suction Drum Second Stage Offgas Compressor Suction Drum Condensate Desalter Condensate Degassing Drum Stabiliser Reflux Drum Sump Drum HP Steam Condensate Flash Drum First Stage Offgas Compressor Discharge Drum Sump Drum Heater Condensate Preflash Heaters Condensate Desalter Preheater Stabilizer Reboiler Stabilizer Side Reboiler
103-F-201 103-K-201 103-P-201 A/B 103-P-202 A/B 103-P-203 A/B 103-P-204 103-P-205 A/B 103-P-208 103-U-201
103-P-206 A/B 103-T-201
Glycolated Water Filters First Stage & Second Stage Offgas Compressor Desalter Feed Pumps Stabilizer Reflux Pumps Stabilized Condensate Export Pumps Sump Drum Pump Steam Condensate Pumps Condensate Recycle Pump Demulsifier Package
Demulsifier Injection pumps Demulsifier Storage tank
103-U-202
103-P-207 A/B/C/D/E 103-T-202
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 5 of 8
Class: 1
REV.
ITEM
(A) 0
(B) 103-A-101
( C) Stabilized Condensate Air Cooler First Stage Offgas Compressor Aftercooler Second Stage Offgas Compressor Aftercooler Stabilizer Reflux Condenser
(D) 1
(E) 2
(F) 5960 kW
( G)
(N) Design case: S - PW 103-A-102 in one common bay with 103-A-103 sharing fans. Design case: W Design case: S - W
103-A-102
1750 kW
SS 321
32 (2)
150 (1)
Air Cooler
103-A-103
1920 kW
SS 321
82 (2)
150 (1)
Air Cooler
103-A-104
251 kW
SS 321
11.5 (2)
115 (1)
Air Cooler
103-C-101
Condensate Stabiliser
130.4 m
2.6
23.7
CS + 3 mm
11.8 (2)
11.5 (2)
-29/225 (1)
-29/110 (1)
103-D-101
Preflash Drum First Stage Offgas Compressor Suction Drum Second Stage Offgas Compressor Suction Drum Condensate Desalter Condensate Degassing Drum Stabiliser Reflux Drum Sump Drum HP Steam Condensate Flash Drum First Stage Offgas Compressor Discharge Drum
137.2 m
3.55
11.5
LTCS + 3 mm
32 (2)
103-D-102
3.2 m
1.15
2.65
CS + 3 mm
11.5 (2)
105 (1)
103-D-103
11.2 m
1.6
4.5
SS 321
32 (2)
133 (1)
103-D-105
CS + 3 mm
46.5
85
Electrostatic desalter H
103-D-106
CS + 3 mm
3.5 (2)
102 (1)
103-D-107
6.1 m
1.3
4.15
11.5 (2)
85 (1)
103-D-108
36.4 m
2.4
7.2
3.5 (2)
103-D-109
6.9 m
1.4
8 (2)
270 (1)
103-D-110
6.4 m
1.25
4.36
SS 321
32 (2)
133 (1)
103-DH-108
2
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
Electric Heater
Included in 103-D-108
NARGAN
Page 6 of 8
Class: 1
REV.
ITEM
(A) 0
(B)
( C)
(D) 2
(E) 4
(F) 11020 kW
( G)
(M) NEN
Condensate Preflash 103-E-101 A/B Heaters 103-E-102 Condensate Desalter Preheater Stabilizer Reboiler Stabilizer Side Reboiler
3260 kW
12 (2)
46.5 (2)
210 (1)
95 (1)
AES
103-E-103
12030 kW
CS + 3 mm
12 (2)
55 (2)
225 (1)
330 (1)
BKU
103-E-104
6710 kW
CS + 3 mm
11.8 (2)
12 (2)
175 (1)
225 (1)
BXU
103-F-101A/B
51 m/h
LTCS + 3 mm
33 (2)
-46/85 (1)
Cartidge or Basket
103-K-101
DP = 19.1 bar
(3)
(3)
11.5
32.0
105
132
Reciprocating
Pe = 920 KW
DP = 43.9 bar
(3)
(3)
32.0
82.0
132
150
Reciprocating
Pe = 1883 KW
103-P-101 A/B Desalter Feed Pumps Stabilizer Reflux Pumps Stabilized Condensate Export Pumps Sump Drum Pump
344.2 m/h
146 m
(3)
(3)
44.1
85
Centrifugal
Pe = 153 KW
103-P-102 A/B
2.5 m/h
72 m
(3)
(3)
17.3
85
Centrifugal
Pe = 4.9 KW
103-P-103 A/B
290 m/h
151 m
(3)
(3)
18.4
102
Centrifugal
Pe = 139.4 KW
103-P-104
15 m/h
79.1 m
(3)
(3)
13.5
-46 / 175
Pe = 9.5 KW
103-P-105 A/B
Steam Condensate Pumps Demulsifier Injection pumps Corrosion Inhibitor Injection pumps Condensate Recycle Pump
29.5 m/h
150.45 m
(3)
(3)
25.4
270
Centrifugal
Pe = 25.1 KW
Includeed In 103-U-101
10
Included In 103-U-102
160 m/h
626.4 m
(3)
(3)
48.5
102
Centrifugal
Pe = 304 KW
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 7 of 8
Class: 1
REV.
ITEM
(A) 0
(B) 103-T-101
(D) 1
(E) 2
(F)
( G)
(M)
103-T-102
Included In 103-U-102
103-U-101
Each of the two packages contains:- one Storage Tank (103-T-101);- two Injection Pumps (103-P-106 A/B), one in service and one in stand-by. Each of the two packages contains:- one Storage Tank (103-T-102);- five Injection Pumps (103-P-107 A/B/C/D/E);-spare pumps in warehouse.
103-U-102
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 8 of 8
ITEM LIST
Common to phases 15 & 16
109-A-101 109-A-102 109-A-103 109-A-104 109-A-105 109-A-106 109-C-101 109-C-102 109-D-101 109-D-102 109-D-103 109-D-104 109-D-105 109-D-106 109-D-107 109-DH-101 109-E-101 109-E-102 109-F-101 A/B 109-F-102 A/B
First Sour Water Stripper Bottom Cooler First Sour Water Stripper Condenser Second Sour Water Stripper Bottom Cooler Second Sour Water Stripper Condenser First Steam Condensate Surge Drum Condenser Second Steam Condensate Surge Drum Condenser First Sour Water Stripper Second Sour Water Stripper First Sour Water Stripper Feed Drum Second Sour Water Stripper Feed Drum First Sour Water Stripper Reflux Drum Second Sour Water Stripper Reflux Drum First Steam Condensate Surge Drum Second Steam Condensate Surge Drum Sour Water Sump Drum Sour Water Sump Drum Heater First Sour Water Stripper Reboiler Second Sour Water Stripper Reboiler First Sour Water Filters Second Sour Water Filters
109-P-101 A/B/C/D 109-P-102 A/B 109-P-103 A/B 109-P-104 A/B 109-P-105 A/B 109-P-106 A/B 109-P-107 A/B 109-P-108 A/B 109-P-109
Sour Water Stripper Feed Pumps Slop Oil Pumps First Sour Water Stripper Bottom Pumps First Sour Water Stripper Reflux Pumps
Second Sour Water Stripper Bottom Pumps Second Sour Water Stripper Reflux Pumps
First Steam Condensate Pumps Second Steam Condensate Pumps Sour Water Sump Pump
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 4 of 7
Class: 1
REV.
ITEM
(A) 1
(B)
st
( C)
1 SOUR WATER STRIPPER BOTTOM COOLER 1st SOUR WATER STRIPPER CONDENSER 2nd SOUR WATER STRIPPER BOTTOM COOLER 2nd SOUR WATER STRIPPER CONDENSER 1st STEAM COND. SURGE DRUM CONDENSER 2nd STEAM COND. SURGE DRUM CONDENSER
(D) 1
(E) 1
(F)
3320x1.1 Kw
( G) 176.3 m2
(N) Pi=2x55 kW common for 109A-101 and 109-A-103 Pi=2x45 kW common for 109A-102/104/105/106 Pi=2x55 kW common for 109A-101 and 109-A-103 Pi=2x45 kW common for 109A-102/104/105/106 Pi=2x45 kW common for 109A-102/104/105/106 Pi=2x45 kW common for 109A-102/104/105/106
109-A-101
109-A-102
3970 Kw
116.3 m2
SS 321
3.5 (2)
148 (1)
Air cooler
109-A-103
3320x1.1 Kw
176.3 m2
SS 304L
13 (2)
150 (1)
Air cooler
109-A-104
3970 Kw
116.3 m2
SS 321
3.5 (2)
148 (1)
Air cooler
109-A-105
406x1.1 Kw
14.3 m2
CS+3mm
2 (2)
135
Air cooler
109-A-106
406x1.1 Kw
14.3 m2
CS+3mm
2 (2)
135
Air cooler
1 1
109-C-101 109-C-102
1 1
1 1
29.6 m3 29.6 m3
1.35 1.35
20.7 20.7
Bottom up to 12.5m: CS Top: CS (SS316L clad) Bottom up to 12.5m: CS Top: CS (SS316L clad)
Packing Packing
109-D-101
1st SOUR WATER STRIPPER FEED DRUM 2nd SOUR WATER STRIPPER FEED DRUM 1st SOUR WATER STRIPPER REFLUX DRUM 2nd SOUR WATER STRIPPER REFLUX DRUM
44.9 m3
2.4
9.12
CS (SS321 cladding)
3.5 (2)
131 (1)
109-D-102
44.9 m3
2.4
9.12
CS (SS321 cladding)
3.5 (2)
131 (1)
109-D-103
2.4 m3
1.1
2.39
SS 316L
3.5 (2)
148 (1)
109-D-104
2.4 m3
1.1
2.39
SS 316L
3.5 (2)
148 (1)
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 5 of 7
Class: 1
REV.
ITEM
(A) 1
(B) 109-D-105
( C)
1st STEAM CONDENSATE SURGE DRUM 2nd STEAM CONDENSATE SURGE DRUM SOUR WATER SUMP DRUM
(D) 1
(E) 1
(F) 2.4 m3
( G)
(M) H
(N)
109-D-106
2.4 m3
1.1
2.2
CS + 3mm
2 (2)
135 (1)
109-D-107
22.2 m3
2.2
5.1
CS+coating+3mm
3.5(2)
148 (1)
109-DH-101
Electric Heater
Included in 109-D-107
109-E-101
109-E-102
1st SOUR WATER STRIPPER REBOILER 2nd SOUR WATER STRIPPER REBOILER
4.7x103kW
309.3 m2
CS+ 3mm
SS 304L
5.4 (2)
8 (2)
162
270
BKU
4.7x103kW
309.3 m3
CS+ 3mm
SS 304L
5.4 (2)
8 (2)
162
270
BKU
109-F-101
62 m3/h
CS+3mm
11.4 (2)
131 (1)
109-F-102
62 m3/h
CS+3mm
11.4 (2)
131 (1)
31 m3/h
63.2 m
(3)
(3)
11.3
131
Centrifugal
Pe=13.3 kW
5 m3/h
25.2 m
(3)
(3)
6.1
131
Centrifugal
Pe=0.8 kW
42.5 m3/h
26.1 m
(3)
(3)
7.5
150
Centrifugal
Pe=5.2 Kw
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 6 of 7
Class: 1
REV.
ITEM
DESIGNATION OF ITEM
No of ITEM
No of Equi. Total
Main CRITERIA
Second CRITERIA
(A) 1
( C) 1st SOUR WATER STRIPPER REFLUX PUMPS 2nd SOUR WATER STRIPPER BTTOM PUMPS 2nd SOUR WATER STRIPPER REFLUX PUMPS 1st STEAM CONDENSATE PUMPS 2nd STEAM CONDENSATE PUMPS SOUR WATER SUMP PUMP
(D) 1
(E) 2
( G) 46.9 m
(M) Centrifugal
(N) Pe=3.5 kW
109-P-105 A/B
42.5 m3/h
26.1 m
(3)
(3)
7.5
150
Centrifugal
Pe=5.2 kW
109-P-106 A/B
6.4 m3/h
46.9 m
(3)
(3)
9.3
148
Centrifugal
Pe=3.5 kW
109-P-107 A/B
8.4 m3/h
105.2 m
(3)
(3)
14.4
135
Centrifugal
Pe=8.4 kW
109-P-108 A/B
8.4 m3/h
105.2 m
(3)
(3)
14.4
135
Centrifugal
Centr. Vertical Submerged
Pe=8.4 kW
109-P-109
15 m3/h
55.8 m
(3)
(3)
10.3
148
Pe=3.4 kW
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 7 of 7
ITEM LIST
Phase 15 &16
110-D-101 110-D-102 110-D-103 110-D-104 110-D-105 110-DH-105 110-E-101 A/B 110-E-102 110-E-103 110-F-101 A/B 110-P-101 110-P-102 110-P-103
Sump Drum Sump Drum Heater Condensate Preflash Heater Condensate Second Heater Condensate Final Heater Glycolated Water Filter Stabilized Condensate Pump Steam Condensate Pump Sump Drum Pump
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 4 of 5
Class: 1
REV.
ITEM
(A) 1 1 1 1
( C) PREFLASH DRUM FLASH DRUM DEGASSING DRUM STEAM CONDENSATE FLASH DRUM SUMP DRUM
(D) 1 1 1 1
(E) 1 1 1 1
( G)
(M) H H H V
110-D-105
29.8 m3
2.25
6.75
3.5 (2)
-46/205 (1)
(*) Internals
110-DH-105
45 kW (3)
Included in 110-D-105
110-E-101A/B
CONDENSATE PREFLASH HEATER CONDENSATE SECOND HEATER CONDENSATE FINAL HEATER GLYCOLED WATER FILTERS STABILISED CONDENSATE PUMP STEAM CONDENSATE PUMP SUMP DRUM PUMP
11021x1.1 kW
5 (2)
139 (2)
165 (1)
-46/85 (1)
NEN
Design case: WD
110-E-102
4301x1.1 kW
5 (2)
18 (2)
205 (1)
105 (1)
AES
Design case: S
110-E-103
17344x1.1 kW
18 (2)
55 (2)
205 (1)
330
BEU
Design case: WD
110-F-101 A/B
50.6 m3/h
LTCS+3mm (3)
18 (2)
-46/85 (1)
Cartridge or basket
110-P-101
204m3/h
90.5 m
(3)
12.5
135
Centrifugal
Pe= 55.5 kW
110-P-102
35.7 m3/h
117.3 m
(3)
21.5
270
Centrifugal
Centr. Vertical Submerged
Pe= 20.9 kW
110-P-103
12.9 m3/h
158.7 m
(3)
(3)
17.6
205
Pe= 7.2 kW
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 5 of 5
ITEM LIST
Phase 15 &16
110-D-101 110-D-102 110-D-103 110-D-104 110-D-105 110-DH-105 110-E-101 A/B 110-E-102 110-E-103 110-F-101 A/B 110-P-101 110-P-102 110-P-103
Sump Drum Sump Drum Heater Condensate Preflash Heater Condensate Second Heater Condensate Final Heater Glycolated Water Filter Stabilized Condensate Pump Steam Condensate Pump Sump Drum Pump
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 4 of 5
Class: 1
REV.
ITEM
(A) 2 2 3 2
( C) PREFLASH DRUM FLASH DRUM DEGASSING DRUM STEAM CONDENSATE FLASH DRUM SUMP DRUM
(D) 1 1 1 1
(E) 1 1 1 1
( G)
(M) H H H V
110-D-105
29.8 m3
2.25
6.75
3.5 (2)
-46/205 (1)
(*) Internals
110-DH-105
45 kW (3)
Included in 110-D-105
110-E-101A/B
CONDENSATE PREFLASH HEATER CONDENSATE SECOND HEATER CONDENSATE FINAL HEATER GLYCOLED WATER FILTERS STABILISED CONDENSATE PUMP STEAM CONDENSATE PUMP SUMP DRUM PUMP
11021x1.1 kW
5 (2)
139 (2)
165 (1)
-46/85 (1)
NEN
Design case: WD
110-E-102
4301x1.1 kW
5 (2)
18 (2)
205 (1)
105 (1)
AES
Design case: S
110-E-103
17344x1.1 kW
18 (2)
55 (2)
205 (1)
330
BEU
Design case: WD
110-F-101 A/B
50.6 m3/h
LTCS+3mm (3)
18 (2)
-46/85 (1)
Cartridge or basket
110-P-101
204m3/h
90.5 m
(3)
12.5
135
Centrifugal
Pe= 55.5 kW
110-P-102
35.7 m3/h
117.3 m
(3)
21.5
270
Centrifugal
Centr. Vertical Submerged
Pe= 20.9 kW
110-P-103
12.9 m3/h
158.7 m
(3)
(3)
17.6
205
Pe= 7.2 kW
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 5 of 5
ITEM LIST
Phases 15&16 -Train 1 Phases 15&16 -Train 2
122-D-101 A 122-D-102 A
122-D-101 B 122-D-102 B
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 4 of 5
Class: 1
REV.
ITEM
(A) 0 0
(B)
( C)
(D) 2 2
(E) 2 2
(F) 7.1 m
3
( G)
(M) V V
122-D-101 A/B HP Fuel Gas Drums 122-D-101 A/B HP Fuel Gas Drums
3.7 m3
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 5 of 5
Onshore
ITEM LIST
Common to Phasees 15 &16 147-A-101 147-D-101 A/B 147-D-102 A/B 147-D-103 A/B 147-D-104 147-D-105 147-D-106 147-D-107 147-D-108 147-D-109 147-E-101 147-E-102 147-E-103 147-E-104 147-K-101 A/B 147-K-102 A/B 147-P-101 A/B 147-P-102 147-P-103 A/B/C 147-P-104 147-P-106 147-P-107 147-P-108 147-P-109
Refrigerant Condenser Low Pressure Suction Drums Medium Pressure Suction Drums High Pressure Suction Drums Refrigerant Surge Drum Propane BOG Compressor Suction Drum Recovered Propane Drum LPG Flare KO Drum Refrigeration Area Drain Drum Tank Area Drain Drum Low Pressure Propane Chiller Medium Pressure Propane Chiller High Pressure Propane Chiller Propane Boil Off Gas Condenser Refrigerant Compressor Propane Boil Off Gas Compressor Propane Loading Pumps Propane Circulation Pump Propane Loading Pumps Propane Circulating Pump Propane Recovery Pump Refrigeration Area Drain Drum Pump Tank Area Drain Drum Pump Recovered Propane Transfer Pump
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Propane Storage Tank Propane Storage Tank LPG Tank Flare Package
Page 4 of 6
Page 5 of 5
(A) 0
(B) 147-A-101
( C) REFRIGERANT CONDENSER
(D) 1
(E) 1
(F) 19.3 MW
( G) HOLD m2
(H)
(I)
(N) Pi=19276.6 KW
LTCS + 3mm
0 0 0 0 0 0 0 0 0
147-D-101 A/B 147-D-102 A/B 147-D-103 A/B 147-D-104 147-D-105 147-D-106 147-D-107 147-D-108 147-D-109
LOW PRESSURE SUCTION DRUMS MEDIUM PRESSURE SUCTION DRUMS HIGH PRESSURE SUCTION DRUMS REFRIGERANT SURGE DRUM PROPANE BOG COMPRESSOR SUCTION DRUM RECOVERED PROPANE DRUM LPG FLARE K.O. DRUM REFRIGERANT AREA DRAIN DRUM TANK AREA DRAIN DRUM
2 2 2 1 1 1 1 1 1
2 2 2 1 1 1 1 1 1
LTCS + 3mm LTCS + 3mm LTCS + 3mm LTCS + 3mm LTCS + 3mm LTCS + 3mm LTCS + 3mm LTCS + 3mm LTCS + 3mm
V V V H V H H H H
Internals: SS (4) Internals: SS (4)
0 0 0 0
LOW PRESSURE PROPANE CHILLER MEDUIM PRESSURE PROPANE CHILLER HIGH PRESSURE PROPANE CHILLER PROPANE BOIL OFF GAS CONDENSER
1 1 1 1
1 1 1 1
LTCS + 3mm LTCS + 3mm LTCS + 3mm LTCS + 3mm LTCS + 3mm LTCS + 3mm LTCS + 3mm LTCS + 3mm
18 18 18 18
Design case : Holding Design case : Holding Design case : Holding Design case : Holding
147-K-101 A/B
REFRIGERANT COMPRESSOR
18 18 18 3.5
28 28 28 3.5
147-K-102 A/B
28965 kg/hr
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 5 of 6
Page 5 of 5
(A) 0 0 0 0 0 0 0 0
(B)
( C)
(D) 3 1 3 1 1 1 1 2
(E) 3 1 3 1 1 1 1 2
(F) 1250 m3/hr 339 m3/hr 1250 m3/hr 339 m3/hr 2 m3/hr 21 m3/hr 15 m3/hr 52.2 m3/hr
( G) 19.74 bar 21.3 bar 19.74 bar 21.3 bar 21.6 bar 9.24 bar 7.6 bar 4.2 bar
(H)
(I)
(M) Cent. Vertical Submerged Cent. Vertical Submerged Cent. Vertical Submerged Cent. Vertical Submerged Reciprocating Cent. Vertical Submerged Cent. Vertical Submerged Centrifugal
147-P-103 A/B/C PROPANE LOADING PUMPS 147-P-104 147-P-106 147-P-107 147-P-108 147-P-109 A/B PROPANE CIRCULATION PUMP PROPANE RECOVERY PUMP REFRIGERATION AREA DRAIN DRUM PUMP TANK AREA DRAIN DRUM PUMP RECOVERED PROPANE TRANSFER PUMP
0 0 0
PROPANE STORAGE TANKS PROPANE STORAGE TANKS LPG TANK FLARE PACKAGE
1 1 1
1 1 1
working capacity
45000m3
working capacity
by vendor by vendor
by vendor by vendor
by vendor by vendor
-50 / 55 -50 / 56
45000m4 HOLD
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 6 of 6
Onshore
ITEM LIST
Common to Phasees 15 &16 148-E-101 148-E-102 148-E-103 148-P-101 A/B/C 148-P-102 148-P-103 A/B/C 148-P-104 148-T-101 148-T-102
High Pressure Butane Chiller Medium Pressure Butane Chiller Butane Circulation Subcooler Butane Loading Pumps Butane Circulating Pump Butane Loading Pumps Butane Circulating Pump Butane Storage Tank Butane Storage Tank
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 4 of 5
Page 5 of 5
(A) 0 0 0
( C) High Pressure Butane Chiller Medium Pressure Butane Chiller Butane Circulation Subcooler
(D) 1 1 1
(E) 1 1 1
(H)
(I)
(N) Design case : HOLDING Design case : HOLDING Design case : HOLDING
0 0 0 0
3 1 3 1
3 1 3 1
Centr, Vertical Submerged Centr, Vertical Submerged Centr, Vertical Submerged Centr, Vertical Submerged
0 0
148-T-101 148-T-102
1 1
1 1
by vendor by vendor
by vendor by vendor
by vendor by vendor
-15 / 55 -15 / 55
This document is the property of N.I.O.C.. Any unauthorized attempt to reproduce it, in any form, is strictly prohibited.
NARGAN
Page 5 of 5