VLT AutomationDrive

F4
F3

VLT AutomationDrives are available in


numerous enclosure frame sizes illustrated
at right and in several power ranges shown
in the charts on the following pages.

F2
F1

E1

D2

E2
D4

D1
D3

C2
C1
C4
A5
A1

HP
1/3
1/2
3/4
1
1-1/2
2
3
4
5
7-1/2
10
15
20
25
30
40
50
(1)

% Torque
Overload (1)
160%
160%
160%
160%
160%
160%
160%
160%
160%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%

Output
Cont.
Int.
1.8
2.9
2.4
3.8
3.5
5.6
4.6
7.4
6.6
10.6
7.5
12.0
10.6
17.0
12.5
20.0
16.7
26.7
24.2
38.7
30.8
33.9
30.8
49.3
46.2
50.8
46.2
73.9
59.4
65.3
59.4
89.1
74.8
82.3
74.8
112
88
96.8
88
132
115
127
115
173
143
157
143
215
170
187

Cont.
1.6
2.2
3.2
4.1
5.9
6.8
9.5
11.3
15.0
22
28
28
42
42
54
54
68
68
80
80
104
104
130
130
154

B4

B1
B3

A2 A3

200 240 VAC 3 (FC 301 & FC 302)


Current [A]

C3

B2

Input

Int.
2.6
3.5
5.1
6.6
9.4
10.9
15.2
18.1
24.0
35.2
30.8
44.8
46.2
67.2
59.4
81
74.8
102
88
120
114
156
143
195
169

Enclosure Rating/Frame Size (2)


Est. Power
Protected
Loss @
NEMA 1 NEMA 12
Rated Max. Chassis
IP20
IP21
IP55
IP66
Load (W)
21
29
42
A1(3), A2
A2
A5
A5
54
63
82
116
A2
A2
A5
A5
155
A3
A3
A5
A5
185
239
310
B3
B1
B1
B1
371
514
463
602
B4
B2
B2
B2
624
737
740
845
C3
C1
C1
C1
874
1140
1143
1353
C4
C2
C2
C2
1400
1636

% Torque Overload is rated for 60 seconds. All 110% overload units provide one power size greater HP output. For example, a drive rated at 10 HP for160%
overload is rated at 15 HP for 110% overload.

See pages 5697 for frame size dimensions and weights.

(2)
(3)

A1 frame size is available for FC 301 models only.

www.danfossdrives.com

For variable torque applications, contact Danfoss


1.800.432.6367

Performance Data
380 480 VAC 3 (FC 301); 380 500 VAC 3: (FC 302)
HP
1/2
3/4
1
1-1/2
2
3
4
5
7-1/2
10
15

20

25

30

40

50

60

75

100
(1)

Voltage
Range % Torque
VAC (1) Overload (2)
380440
160%
441500
380440
160%
441500
380440
160%
441500
380440
160%
441500
380440
160%
441500
380440
160%
441500
380440
160%
441500
380440
160%
441500
380440
160%
441500
380440
160%
441500
160%
380440
110%
160%
441500
110%
160%
380440
110%
160%
441500
110%
160%
380440
110%
160%
441500
110%
160%
380440
110%
160%
441500
110%
160%
380440
110%
160%
441500
110%
160%
380440
110%
160%
441500
110%
160%
380440
110%
160%
441500
110%
160%
380440
110%
160%
441500
110%
160%
380440
110%
160%
441500
110%

Current [A]

Output
Cont.
Int.
1.3
2.1
1.2
1.9
1.8
2.9
1.6
2.6
2.4
3.8
2.1
3.4
3
4.8
2.7
4.3
4.1
6.6
3.4
5.4
5.6
9.0
4.8
7.7
7.2
11.5
6.3
10.1
10
16
8.2
13.1
13
20.8
11
17.6
16
25.6
14.5
23.2
24
38.4
32
35.2
21
33.6
27
29.7
32
51.2
37.5
41.3
27
43.2
34
37.4
37.5
60
44
48.4
34
54.4
40
44
44
70.4
61
67.1
40
64
52
57.2
61
91.5
73
80.3
52
78
65
71.5
73
110
90
99
65
97.5
80
88
90
135
106
117
80
120
105
116
106
159
147
162
105
158
130
143
147
221
177
195
130
195
160
176

35
42
46

A1(3), A2

A2

A5

A5

A2

A2

A5

A5

A3

A3

A5

A5

B3

B1

B1

B1

B4

B2

B2

B2

C3

C1

C1

C1

C4

C2

C2

C2

58
62
88
116
124
187
255
291
392
291
392
379
465
379
465
444
525
444
525
547
739
547
739
570
698
570
698
697
843
697
843
891
1083
891
1083
1022
1384
1022
1384
1232
1474
1232
1474

% Torque Overload is rated for 60 seconds. All 110% overload units provide one power size greater HP output. For example, a drive rated at 75 HP for160%
overload, is rated at 100 HP for 110% overload.

See pages 5697 for frame size dimensions and weights.

(2)
(3)

Input
Cont.
Int.
1.2
1.9
1.0
1.6
1.6
2.6
1.4
2.2
2.2
3.5
1.9
3.0
2.7
4.3
2.7
4.3
3.7
5.9
3.1
5.0
5.0
8.0
4.3
6.9
6.5
10.4
5.7
9.1
9.0
14.4
7.4
11.8
11.7
18.7
9.9
15.8
14.4
23.0
13.0
20.8
22
35.2
29
31.9
19
30.4
25
27.5
29
46.4
34
37.4
25
40
31
34.1
34
54.4
40
44
31
49.6
36
39.6
40
64
55
60.5
36
57.6
47
51.7
55
82.5
66
72.6
47
70.5
59
64.9
66
99
82
90.2
59
88.5
73
80.3
82
123
96
106
73
110
95
105
96
144
133
146
95
143
118
130
133
200
161
177
118
177
145
160

Est. Power
Enclosure Rating/Frame Size (2)
Loss @ Protected
Rated Max. Chassis NEMA 1 NEMA 12
IP20
IP21
IP55
IP66
Load (W)

A1 frame size is available for FC 301 models only.

1.800.432.6367

For variable torque applications, contact Danfoss


www.danfossdrives.com

VLT AutomationDrive
380 500 VAC 3: (FC 302)

HP

Voltage
Range
VAC (1)
380440

125
441500
380440
150
441500
380440
200
441500
380440
250
441500
380440
300
441500
380440
350
441500
380440
450
441500
380440
500
441500
380440
550
441500
(1)

% Torque
Overload (2)
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%

Current [A]
Output
Cont.
Int.
177
266
212
233
160
240
190
209
212
318
260
286
190
285
240
264
260
390
315
347
240
360
302
332
315
473
395
435
302
453
361
397
395
593
480
528
361
542
443
487
480
720
600
660
443
665
540
594
600
900
658
724
540
810
590
649
658
987
745
820
590
885
678
746
695
1043
800
880
678
1017
730
803

Input
Cont.
174
208
158
185
204
251
183
231
251
304
231
291
304
381
291
348
381
463
348
427
472
590
436
531
590
647
531
580
647
733
580
667
684
787
667
718

Est. Power
Loss @
Rated Max.
Load (W)
2641
3234
2641
3234
2995
3782
2995
3782
3425
4213
3425
4213
3910
5119
3910
5119
4625
5893
4625
5893
6005
7630
6005
7630
6960
7701
6960
7701
7691
8879
7691
8879
7964
9428
7964
9428

Enclosure Rating/Frame Size (2)


Chassis
IP00

NEMA 1
IP21

NEMA 12
IP54

D3

D1

D1

D4

D2

D2

E2

E1

E1

% Torque Overload is rated for 60 seconds. All 110% overload units provide one power size greater HP output. For example, a drive rated at 125 HP
for160% overload, is rated at 150 HP for 110% overload.

See pages 5697 for frame size dimensions and weights.

(2)

For variable torque applications, contact Danfoss


www.danfossdrives.com

1.800.432.6367

Performance Data
380 500 VAC 3: (FC 302)
Enclosure Rating/Frame Size (2)

HP

Voltage
Range
VAC (1)
380440

600
441500
380440
650
441500
380440
750
441500
380440
900
441500
380440
1,000
441500
380440
1,200
441500
(1)

% Torque
Overload (2)
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%

Cont.
800
880
730
780
880
990
780
890
990
1120
890
1050
1120
1260
1050
1160
1260
1460
1160
1380
1460
1720
1380
1530

Current [A]
Output
Int.
1200
968
1095
858
1320
1089
1170
979
1485
1232
1335
1155
1680
1386
1575
1276
1890
1606
1740
1518
2190
1892
2070
1683

Input
Cont.
779
857
711
759
857
964
759
867
964
1090
867
1022
1090
1227
1022
1129
1227
1422
1129
1344
1422
1675
1344
1490

NEMA 1
IP21

NEMA 12
IP54

F1 or F3

F1 or F3

F2 or F4

F2 or F4

% Torque Overload is rated for 60 seconds. All 110% overload units provide one power size greater HP output. For example, a drive rated at 1,200 HP
for160% overload, is rated at 1,350 HP for 110% overload.

See pages 5697 for frame size dimensions and weights.

(2)

For variable torque applications, contact Danfoss


1.800.432.6367

www.danfossdrives.com

VLT AutomationDrive
525 600 VAC 3 (FC 302)
HP
1
1-1/2
2
3
4
5
7-1/2
10

15

20

25

30

40

50

60

75

100

(1)
(2)

Voltage
Range % Torque
VAC (1) Overload (1)
525-550
160%
551-600
525-550
160%
551-600
525-550
160%
551-600
525-550
160%
551-600
525-550
160%
551-600
525-550
160%
551-600
525-550
160%
551-600
525-550
160%
551-600
160%
525-550
110%
160%
551-600
110%
160%
525-550
110%
160%
551-600
110%
160%
525-550
110%
160%
551-600
110%
160%
525-550
110%
160%
551-600
110%
160%
525-550
110%
160%
551-600
110%
160%
525-550
110%
160%
551-600
110%
160%
525-550
110%
160%
551-600
110%
160%
525-550
110%
160%
551-600
110%
160%
525-550
110%
160%
551-600
110%

Current [A]
Output
Input
Cont.
Int.
Cont.
Int.
1.8
2.9
1.7
2.7
1.7
2.7
2.6
4.2
2.4
3.8
2.4
3.8
2.9
4.6
2.7
4.3
2.7
4.3
4.1
6.6
4.1
6.6
3.9
6.2
5.2
8.3
5.2
8.3
4.9
7.8
6.4
10.2
5.8
9.3
6.1
9.8
9.5
15.2
8.6
13.8
9.0
14.4
11.5
18.4
10.4
16.6
11.0
17.6
19.0
30.0
17.2
28.0
23.0
25.0
20.9
23.0
18.0
29.0
16.0
26.0
22.0
24.0
20.0
22.0
23.0
37.0
20.9
33.0
28.0
31.0
25.4
28.0
22.0
35.0
20.0
32.0
27.0
30.0
24.0
27.0
28.0
45.0
25.4
41.0
36.0
40.0
32.7
36.0
27.0
43.0
24.0
39.0
34.0
37.0
31.0
34.0
36.0
58.0
32.7
52.0
43.0
47.0
39.0
43.0
34.0
54.0
31.0
50.0
41.0
45.0
37.0
41.0
43.0
65.0
39.0
59.0
54.0
59.0
49.0
54.0
41.0
62.0
37.0
56.0
52.0
57.0
47.0
52.0
81.0
49.0
74.0
54.0
65.0
72.0
59.0
65.0
52.0
78.0
47.0
70.0
62.0
68.0
56.0
62.0
65.0
98.0
59.0
89.0
87.0
96.0
78.9
87.0
62.0
93.0
56.0
85.0
83.0
91.0
75.0
83.0
87.0
131.0
78.9
118.0
105.0
116.0
95.3
105.0
83.0
125.0
75.0
113.0
100.0
110.0
91.0
100.0
105.0
158.0
95.3
143.0
137.0
151.0
124.3
137.0
100.0
150.0
91.0
137.0
131.0
144.0
119.0
131.0

% Torque Overload is rated for 60 seconds.


See pages 5697 for frame size dimensions and weights.

www.danfossdrives.com

Enclosure Rating/Frame Size (2)


Est. Power
Loss @ Rated Protected
Max. Load
Chassis
NEMA 1 NEMA 12
(W)
IP20
IP21
IP55
IP66
35
50
65
A3

A3

A5

A5

A3

A3

A5

A5

B3

B1

B1

B1

B4

B2

B2

B2

B4

C1

C1

C1

C3

C1

C1

C1

C4

C2

C2

C2

92
122
145
195
261

225

285

329

700

700

850

1100

1400

1500

For variable torque applications, contact Danfoss


1.800.432.6367

Performance Data
525 690 VAC 3 (FC 302)

HP

kW

40

30

50

37

60

45

75

55

100

75

125

90

150

110

200

132

250

160

300

200

350

250

400

300

450

315

500

400

600

450

650

500

750

560

950

670

1050

750

1150

850

% Torque
Overload (1)
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%
160%
110%

Cont.
46
54
54
73
73
86
86
108
108
131
131
155
155
192
192
242
242
290
290
344
344
400
380
450
410
500
500
570
570
630
630
730
730
850
850
945
945
1060
1060
1260

Current [A]
(@ 575V Nominal)
Output
Int.
74
59
86
80
117
95
129
119
162
144
197
171
233
211
288
266
363
319
435
378
516
440
570
495
615
550
750
627
855
693
945
803
1095
935
1275
1040
1418
1166
1590
1386

Input
Cont.
51
58
58
74
74
85
85
106
106
124
124
151
151
189
189
234
234
286
286
339
339
390
366
434
395
482
482
549
549
607
613
711
711
828
828
920
920
1032
1032
1227

Est. Power
Loss @
Rated Max.
Load (W)
1355
1458
1459
1717
1721
1913
1913
2262
2264
2262
2664
3114
2953
3612
3451
4292
4275
5156
4875
5821
5185
6149
5383
6449
5818
7249
7671
8727
8715
9673

Enclosure Rating/Frame Size (2)


Chassis
IP00

NEMA 1
IP21

NEMA 12
IP54

D3

D1

D1

D4

D2

D2

E2

E1

E1

F1 or F3

F1 or F3

F1 or F3

F2 or F4

F2 or F4

F2 or F4

(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)

% Torque Overload is rated for 60 seconds. All 110% overload units provide one power size greater HP output. For example, a drive rated at 75 HP for160%
overload, is rated at 100 HP for 110% overload. The 1150 HP unit is rated for 1350 HP for 110% overload.
(2)
See pages 5697 for frame size dimensions and weights.
(3)
Contact Danfoss.
(1)

For variable torque applications, contact Danfoss


1.800.432.6367