You are on page 1of 2

Product Data Sheet

RM35TF30
3 PHASE RELAY 250V 5AMP RM35
List Price $273.00 USD

Availability Stock Item: This item is normally stocked in our distribution facility.

Technical Characteristics
Vibration Resistance - Operational Shock Resistance Degree of Protection Wiring range: Solid Cable without Cable End Application Function Supply Voltage Voltage Limits Adjustment of Voltage Threshold Frequency of Measured Signal Current Rating Contact Type Electrical Life (UL508) Operations at Rated Current (Resistive) Contact Configuration Frequency Hysteresis Output Type Operating Range Minimum Breaking Current Insulation Test Voltage: Shock Wave Maximum Measuring Cycle Maximum Response In The Event of A Fault Measurement Range Phase-Phase Voltage Selection Setting Accuracy Utilization Categories Delay on Pick-up Time Delay on Crossing The Threshold Tt Ambient Air Temperature around the Device - Operation Ambient Air Temperature around the Device - Storage Permissible Relative Humidity Wiring Range: Flexible Cable with Cable End 0.035 mm from 10 to 150 Hz 5 IP30 (Casing) - IP20 (Terminal Block) Two: 16 to 20 AWG (1.5 to 0.5 mm2) - One: 14 to 20 AWG (2.5 to 0.5 mm2) Control of 3-phase supplies Phase failure - Asymmetry - Overvoltage or undervoltage - Phase sequence 220 to 480 VAC -15% to +10% 2 to 20 % of Un selected 50 to 60 Hz 10% 5 A (1 A at 24 VDC, 5 A at 24 VAC, 3 A at 250 VAC) Cadmium-free 10,000 operations DPDT 50/60 Hz 10% 2% of Un, Fixed 1904-01-01 05:00:00 194 to 528 VAC 10 V at 5 VDC 4 kV 140 ms per measurement as true rms value < 200 ms 194 to 528 VAC 220V - 380V - 480V - 400V - 415 - 440V 10% of the full scale value AC-12 - AC-14 - AC-13 - DC-13 - DC-12 - AC-15 500 ms 0.1 to 10 sec, 0 + 10% -20 to 50 -40 to 70 2 x 24 hrs. to +95% RH at +131 8F (55 8C) without condensation Two: 16 to 20 AWG (1.5 to 0.5 mm2) - One: 14 to 20 AWG (2.5 to 0.5 mm2)

Generated: 11/30/2011 10:48:33

2011 Schneider Electric. All rights reserved.

Tightening Torque Type Indication (LED) Mounting Style Weight Approvals Mechanical Life Unpowered Maximum Switching Requirement Maximum Consumption AC Maximum Consumption DC Insulation Test Voltage: Dielectric Test

0.6 to 1 N.m / 5.3 to 8.8 lb-in 35mm width 3 Din Rail 129.69999999999999 UL - CSA - CE - RoHS - GL - C-Tick - IEC - GOST - NF - EEC - EN - EMC 30,000,000 operations 250 VAC/VDC 1.8 0 2 kV at 50 Hz for 1 min. on VAC

Shipping and Ordering


Category Discount Schedule GTIN Package Quantity Weight Availability Code Returnability Country of Origin 22380 CP2 00785901596745 1 0.28 lbs. Stock Item: This item is normally stocked in our distribution facility. Y ID

As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document.

Generated: 11/30/2011 10:48:33

2011 Schneider Electric. All rights reserved.