Table of Contents
Training Program Offered Key Personnel Major Projects List of Major Customer List Of Equipment
Our History
August 1983 by Rolando R. Ortaez, the first field engineer and former Vice-President Operations of Asiatic Corrosion Control Co., Inc. (ACCCO). But, it was only in September 1985 when the company started its operations. In the first job contract, Mr. Ortaez worked together with his promising colleague at ACCCO Mr. Walter B. Samsaman.
ACSI is more than 20 years in operation and has gained extensive experience in Non-Destructive Testing, Industrial Inspection Services and Cathodic Protection System. Because of dependability on and quality of jobs, the services of ACSI had been tapped by no less than the major petroleum companies, power utility and industrial firms in the country. It has rendered services to the following companies: Shell Refinery, Caltex (Phils.) Inc., Petron Corporation, National PNOC-Energy Power Development Philippine Corporation, Corporation,
Petroleum, Corporation, Bataan Refinery, Sembawang, and Procter & Gamble Corporation. ACSI is the subcontractor in Non-Destructive Examination Services of Fluor Daniels Pacific, the Project Manager of Shell Refinery during the expansion of its plant in Batangas. Another milestone in our experience is when we did the NDT works for Sembawang (Philippines) Inc. during the construction of the First Gas Power Corporation Sta. Rita 1000MW CCPS Project. The people behind ACSI promise to live up to its name as CORROSION and INSPECTION SPECIALIST. It is determined to grow up as a reputable company, if not a giant in the field of corrosion and industrial inspection industry. It intends to serve the oil and gas, petrochemical, refining, and co-generation industries with utmost efficiency and reliability.
Cathodic Protection
NonDestructive Testing
Training
Cathodic Protection with Impressed Current It is a CP system which has a Rectifier that provides sufficient direct current to protect the entire surface of the structure. The current and voltage output of the Transformer Rectifier are variable to provide efficient protection of the structure. Installation Deep Anode Drilling Complete Installation System Repair Grounding System Instrument and Accessories Groundbed Relocation welding Supplies Thermit Test Stations Maintenance Services Di-electric Insulating Material Cathodic Protection Review Routine and Non-routine CP Surveys
Design Economic Feasibility Studies Plans and Drawings oSpecifications Research and Developments Field Testing Current Requirements Soil Corrosivity Potential Profile Close Interval Stray Current and Interference Direct Current Voltage Gradient Rectifier Trouble Shooting
Radiographic Testing Technique in examination of internal defects through the use of X-rays or Gamma Rays
Ultrasonic Testing
Type of testing that introduces high frequency sound waves into the material to obtain information such as thickness, defects and other material properties
Angle Probe
Magnetic Particle Testing Non-Destructive testing technique that utilizes a permanent magnet or magnetizing prod on magnetic particles.
Maintenance Inspection
General and Close Visual Paint and Corrosion Surveys Non-Destructive Testing Internal Inspections API 653 Oil Storage Tank Inspection Painting Internal Vessel work Cutting and Welding Sandblasting Fire Safety Systems Mastic repairs Roofing and Flashing
Equipment Supply
Full Body Harness Safety Helmet Positioning Lanyards Energy Saving Lanyards Carabiners and Connectors Anchors Pylon Hooks Stuff Bag
Training Programs
Non-Destructive Testing CWSIP, PCN, ACCP & ASNT CERTIFICATION : Levels 1, 2, & 3 Welding Inspection AWS Welders Certification AWS Cathodic Protection Inspection - CSWIP Certification : Levels 1, 2, 3
Pressure Vessel API 510 Tank Inspection API 653 Pipings API 570 Painting and Coating Inspection SSPC Rope Access Safety Code of Practice ISO 9000/1400 OHSAS 1800 Power Plant Mechanical Maintenance
Key Personnel
Name
Rolando R. Ortanez
Position
President
Specialization
NACE Trained In Cathodic Protection, API 653 Certified Storage Tank Inspector (Expired), AWS Certified CWI Inspector (Expired) , NDT Level 2, ISO 9001:2000 Lead Auditor NACE Trained In Cathodic Protection and Basic Corrosion, AWS Certified CWI Inspector, PWS Certified CWI Inspector ASNT Certified Level 3 In RT, PT, RT, MT (Certificate No. 25565) / NACE CP 4 Cathodic Protection Specialist (Certificate No. 5082) / NACE CP 4 Cathodic Protection Specialist
Rodrigo B. Ortanez
Vice-President
Aquilino T. Barboza William G. Ramos Robert Bob Walker Thomas M. Magbanua Santos R. Pedrigal
NDT Examiner / NDT, Welding Inspection, Third Party In House Level 3 Inspection, Welders Prequalification Assesor for Welders TESDA Accredited Assessor / Trainor of Welders
Highlighted Projects
ITEM 1 CUSTOMER PNOC Project - EDC WORK DESCRIPTION Provision of NDT Teams to do RT, MT and PT of welds during the PNOC EDC piping installation at : Palinpinon Geothermal Dumaguete Bacon / Manito Sorsogon Geothermal Mahanagdong / Upper Mahiao Southern Leyte Malitbog Geothermal Project Fluor Daniels Pacific, Provision of NDT Teams to do Inc. RT, UT, PT and MT, Welding Inspectors and QC Inspectors during the expansion of Pilipinas Shell Refinery (STAR Project) at Tabangao, Batangas Pilipinas Shell Rehabilitation of Impressed Petroleum Corp. Current Cathodic Protection Of Jetty Loading Facilities Subic Shipyard Inc. Supply of NDT Team to Subic Zambales conduct UT, RT, MPT Keppel Shipyard Inc. Supply of NDT Team to Batangas conduct RT, UT, MPI Petron Bataan Refinery Supply of NDT Team to Limay Bataan conduct Turn Around Inspection Supply of NDT Team and Tank Inspector for the 2002 General Tankage Inspection On Stream and Out of Service Inspection of Bulk Storage Tanks at various Stoc Point 1985 1988 1997 1998 Year
1993-1995
3 4 5 6
2002 1995-2000
Contact Person
POWER PLANTS
Covanta Phils Kephilco
Mirant Phils. Corporation
Mauban, Quezon Pililla, Rizal Pagbilao, Power Plant, Pagbilao, Quezon Sual Power Station, Sual Pangasinan Sta. Rita, Batangas SBMA, Subic
Mr. Earl Dy Mr. Ed de Leon Mr. Marlon Palomar Mr. Rainier Atienza
BF Corporation Brown & Roots Industrial Srvcs., Inc. CBI Philippines EEI Corporation Federal Builders Fluor Daniel Pacific, Inc. Grandspan Development Corporation Jits Construction K Star Metallite Builders Metaphil Corporation Inc. Miescor Incorporated MVS Builders Sempec
Asia Corrosion Services, Inc.
Cainta, Rizal Bauan, Batangas Cainta, Rizal Tabangao, Batangas Paranaque Ugong, Pasig City Manggahan, Pasig City Makati City Tabangao, Batangas Binangonan, Rizal Antipolo City Binan, Laguna Obando, Bulacan Tipolo, Mandaue City Pasig City Antipolo City / Cainta, Rizal Sta.Rita, Batangas
Mr. Antonio Vasquez Mr. Alain Daya Mr. Roman Robleza Mr. Mike Ferrer Mr. Nelson Marquez Mr. Romy Manalo Mr. Bobby Ibanez Mr. Esteban Veloria Mr. Poy Lacsamana Mr. Andy Ang Mr. Edwin Baydo Mr. Danny Castro Mr. Ariel Dumalaog Mr. Augusat Dacanay Mr. Adrian Moncada Mr. Joe Zaratan Mr. Chiong Lim
INDUSTRIAL
ALC Realty
Specialized Trading
Mr. Manny Salazar Mr. Oscar Abella Mr. Tony Calayag Ms. Lorna Preclaro
GEOTHERMAL
Philippine Geothermal Inc.
Philippine National Oil Co. EDC
List of Equipments
CATHODIC PROTECTION
Quantity
2 unit 3 unit 4 pcs. 1 unit 1 unit 2 unit 3 sets 2 units
Item Description
MCM Current Interrupter Soil Resistance Meter (Model 400) Cooper Copper Sulfate 8A Half Cell Electrode MCM Electronic DC Voltmeter Model 372-M MCM MC Miller Co. DC Clamp Meter Clamp Ag-AgCl Reference Electrode Fluke Multimeter
RADIOGRAPHIC TESTING
Quantity
8 units 14 units 8 sets 14 pcs. 3 units 4 units 1 unit 1 unit 4 units 1 lot 1 lot 2 pcs. 1 pc. 12 pcs. 4 sets 2 pcs. 1 pc. 1 pc.
Item Description
Techops Model 660 w/ IR 192 Sealed Source Survey Meters Cranking Cable w/ Source Guide and Extension Pendosimeter Dosimeter Charger Densitometer Agfa Automatic Film Processor Agfa Automatic Film Dryer Film Viewer Assorted Size Film Cassettes w/ Lead Screen Stainless Steel Hanger and Processing Tanks Tungsten Collimator Lead Collimator Lead Pot Metal Puncher Letters and Numbers Exposure Scrata Lead Vest Lead Gloves
ULTRASONIC TESTING
Quantity
1 set 2 sets 1 set 1 set 1 set 2 sets 1 set 1 set 5 pcs. 3 pc. 5 pcs. 4 pcs.
Item Description
Epoch III With B-Scan USK6 Krautkramer Ultrasonic Flaw Detector USK7 Krautkramer Ultrasonic Flaw Detector SM90 Tokyo Keiki Ultrasonic Flaw Detector Model 220 Acoustical Ultrasonic Flaw Detector AD & D Digital Ultrasonic Flaw Detector DMS Krautkramer Branson Digital Thickness Gauge 26 DL Plus Panametrics Digital Thickness Gauge IIW Calibration Block V2 Calibration Block Stepwedge Calibration Block Profile Gauge
List of Equipments
MAGNETIC PARTICLE TESTING
Quantity
3 pcs. 2 pcs. 3 sets 2 pcs. 1 pc.
Item Description
Electromagnetic Yoke Permanent Magnet Magnaflux Magnetic Fluorescent Blacklight MPI Sprayer (wet) Sprayer Bulb (dry)
STRESS RELIEVING
Quantity
1 set
Item Description
70KW PDS-Mannings Post Weld Heat Treatment Machine
COATING INSPECTION
Quantity
2 units 2 units 2 units 3 units 2 units 2 units 2 units 2 units 2 units 2 units 1 unit 1 unit 1 unit 2 units
Item Description
Elcometer Magnetic Coating Thickness Gauge Magnetic Coating Thickness Gauge The Inspector Magnetic Coating Thickness Gauge Pipe Gauge Surface Profile Gauge Surface Profile Comparator Whirling Hygrometer Magnetic Steel Thermometer Dew Point Calculator Wet Film Thickness Gauge Pinhole Detector (9 volts) DC Holiday Detector (6 to AC KV) Cross Hatch Cutter and Adhesive Tape for Hatch Test Adhesion Test Inspection Mirror
Associates
NAME BUSINESS
SAFETY TRAINING, SAFETY AUDIT, SAFETY OFFICERS, SAFETY PROCEDURES MANUFACTURER OF CORROSION SOLUTION
ESCONADVANCED NDT (MFL, TIME OF FLIGHT DIFFRACTION, TUBE INSPECTION, ETC.) AQUATRADE AND INDUSTRIAL DEVELOPMENT CORP. PRECISION SANDBLASTING INC. UNDERWATER WELDING AND INSPECTION SANDBLASTING & APPLICATION OF SPECIAL PURPOSE COATINGS, TANK LININGS, EPOXY FLOORINGS, WATERPROOFING, EPOXY PRESSURE INJECTION, ETC.