Professional Documents
Culture Documents
CF RELAYS
Normally Normally Open Closed
22.5 .886
16.5 .650
FEATURES
7 Amp Steady/30 Amp Inrush current capability Simple footprint enables ease of PC board layout
mm inch
Common
16.5 .650
SPECIFICATIONS
Contact
Arrangement Contact material Initial contact resistance (Initial) (By voltage drop 6 V DC 1 A) Initial contact voltage drop Nominal switching capacity 1 Form C2 (H bridge) Ag alloy (Cadmium free) Typ. 6 m (N.O.) Typ. 9 m (N.C.) Max. 0.2 V (at 20 A) N.O.: 20A 14 V DC N.C.: 10A 14 V DC 30 A (2 minutes), 20 A (1 hour) (coil applied voltage: 12 V, at 20C) 25 A (2 minutes), 15 A (1 hour) (coil applied voltage: 12 V, at 85C) 1 A 12 V DC 106 Min.105 2105 Min.5104
Characteristics
Max. operating speed (at rated load) Initial insulation resistance*1 Initial Between open contacts breakdown Between contacts and coil voltage*2 Operate time*3 (at nominal voltage) Release time*3 (at nominal voltage) Functional*4 Shock resistance Destructive*5 Functional*6 Vibration resistance Destructive*7 Conditions for operation, transport and storage*8 Ambient temp. (Not freezing and condensing at low Humidity temperature) Mass Standard type Remarks
*1 Measurement at same location as Initial breakdown voltage section *2 Detection current: 10mA *3 Excluding contact bounce time *4 Half-wave pulse of sine wave: 11ms; detection time: 10s *5 Half-wave pulse of sine wave: 6ms *6 Detection time: 10s *7 Time of vibration for each direction; X, Y, direction: 2 hours Y X Z direction: 4 hours
Z
120 cpm Min. 100 M (at 500 V DC) 1,000 Vrms for 1 min. 1,000 Vrms for 1 min. Max. 10 ms (initial) Max. 10 ms (initial) Min. 100 m/s2 {10 G} Min. 1,000 m/s2 {100 G} Approx. 44.1 m/s2 {4.5 G}, 10 Hz to 100 Hz Approx. 44.1 m/s2 {4.5 G}, 10 Hz to 500 Hz 40C to + 85C 40F to +185F 5%R.H. to 85%R.H. Approx. 15 g .529 oz
Rating
Min. switching capacity#1 Mechanical (at 120 cpm) resistive load Expected 7 A 14 V DC, life (min. Inrush 30 A Electrical ope.) (Motor load) 20 A 14 V DC (Motor lock)
Coil
Nominal operating power 640 mW
#1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*8 Refer to Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT. Please inquire if you will be using the relay in a high temperature atmosphere (110C 230F).
TYPICAL APPLICATIONS
Power windows Auto door lock Electrically powered sunroof Electrically powered mirrors Powered seats Lift gates Slide door closers, etc. (for DC motor forward/ reverse control circuits)
ORDERING INFORMATION
Ex. CF Contact arrangement 1 Form C 2
Standard packing: Carton: 35pcs.; Case: 700pcs.
12 V Coil voltage(DC) 12 V
* Other pick-up voltage types are also available. Please contact us for details.
CF
DIMENSIONS
16.5 .650 Max. 1.2 .047 (6-4 dia.) (6-.157 dia.) Land diameter
3.5 .138 0.25 .010 0.25 0.2 .010 .008 1.0 .039 *A 1.0 .039 0.3 Pre-soldering .012 1.0 .039 1.0 .039 0.3 .012
1.0 .039
12.7 .500
3.810.1 4-1.3 dia.0.1 4-.052 dia..004 .150.004 4-1.5 dia.0.1 4-.059 dia..004 7.620.1 10.160.1 .300.004 .400.004
7.62 .300
10.16 .400
Dimension: General tolerance Max. 1mm .039 inch: 0.1 .004 1 to 3mm .039 to .118 inch: 0.2 .008 Min. 3mm .118 inch: 0.3 .012
Schematic
NO COM1 NC COM2
* Dimensions (thickness and width) of terminal specied in this catalog is measured before pre-soldering. Intervals between terminals is measured at A surface level.
EXAMPLE OF CIRCUITS
Forward/reverse control circuits of DC motor for power window
NO 12 V DC NC
COM
COM
NO NC
SW A
SW A OFF ON OFF
SW B OFF OFF ON
REFERENCE DATA
1-(1). Coil temperature rise (at room temperature)
Sample: CF2-12V, 6pcs. Measured potion: Inside the coil Contact carrying current: 10A, 15A, 20A Ambient temperature: Room temperature
100 20A Switching voltage, VDC Temperature rise, C 80 Temperature rise, C 15A 10A 60 80 20A 15A 60 10A 50 40 30 20 10 0
60
40
40
20
20
12
12
10
20 30 40 Switching current, A
50
20 10 0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 Voltage, V
CF
6-(1). Electrical life test (Motor free)
Sample: CF2-12V, 3pcs. Load: Inrush current: 30A, Steady current: 7A, Power window motor actual load (free condition) Switching frequency: (ON:OFF = 1s:5s) Ambient temperature: Room temperature
Circuit
Relay 1 Relay 2 1s 1s 3s 6s (1 cycle)
40
30
20
10
Resistive load
10
15
4
20
No. of operations, 10
Circuit
Relay 1 Relay 2 1s 1s 3s 6s (1 cycle)
40
30
20
10
M
Power window motor (lock)
0 No. of operations, 10
4