You are on page 1of 3

CF

TWIN POWER AUTOMOTIVE RELAY

CF RELAYS
Normally Normally Open Closed

22.5 .886

16.5 .650

FEATURES
7 Amp Steady/30 Amp Inrush current capability Simple footprint enables ease of PC board layout
mm inch
Common

16.5 .650

Coil 1 Open Space Coil 2

SPECIFICATIONS
Contact
Arrangement Contact material Initial contact resistance (Initial) (By voltage drop 6 V DC 1 A) Initial contact voltage drop Nominal switching capacity 1 Form C2 (H bridge) Ag alloy (Cadmium free) Typ. 6 m (N.O.) Typ. 9 m (N.C.) Max. 0.2 V (at 20 A) N.O.: 20A 14 V DC N.C.: 10A 14 V DC 30 A (2 minutes), 20 A (1 hour) (coil applied voltage: 12 V, at 20C) 25 A (2 minutes), 15 A (1 hour) (coil applied voltage: 12 V, at 85C) 1 A 12 V DC 106 Min.105 2105 Min.5104

Characteristics
Max. operating speed (at rated load) Initial insulation resistance*1 Initial Between open contacts breakdown Between contacts and coil voltage*2 Operate time*3 (at nominal voltage) Release time*3 (at nominal voltage) Functional*4 Shock resistance Destructive*5 Functional*6 Vibration resistance Destructive*7 Conditions for operation, transport and storage*8 Ambient temp. (Not freezing and condensing at low Humidity temperature) Mass Standard type Remarks
*1 Measurement at same location as Initial breakdown voltage section *2 Detection current: 10mA *3 Excluding contact bounce time *4 Half-wave pulse of sine wave: 11ms; detection time: 10s *5 Half-wave pulse of sine wave: 6ms *6 Detection time: 10s *7 Time of vibration for each direction; X, Y, direction: 2 hours Y X Z direction: 4 hours
Z

120 cpm Min. 100 M (at 500 V DC) 1,000 Vrms for 1 min. 1,000 Vrms for 1 min. Max. 10 ms (initial) Max. 10 ms (initial) Min. 100 m/s2 {10 G} Min. 1,000 m/s2 {100 G} Approx. 44.1 m/s2 {4.5 G}, 10 Hz to 100 Hz Approx. 44.1 m/s2 {4.5 G}, 10 Hz to 500 Hz 40C to + 85C 40F to +185F 5%R.H. to 85%R.H. Approx. 15 g .529 oz

Rating

Max. carrying current

Min. switching capacity#1 Mechanical (at 120 cpm) resistive load Expected 7 A 14 V DC, life (min. Inrush 30 A Electrical ope.) (Motor load) 20 A 14 V DC (Motor lock)

Coil
Nominal operating power 640 mW
#1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.

*8 Refer to Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT. Please inquire if you will be using the relay in a high temperature atmosphere (110C 230F).

TYPICAL APPLICATIONS
Power windows Auto door lock Electrically powered sunroof Electrically powered mirrors Powered seats Lift gates Slide door closers, etc. (for DC motor forward/ reverse control circuits)

ORDERING INFORMATION
Ex. CF Contact arrangement 1 Form C 2
Standard packing: Carton: 35pcs.; Case: 700pcs.

12 V Coil voltage(DC) 12 V

TYPES AND COIL DATA (at 20C 68F)


Part No. CF2-12V Nominal voltage, V DC 12 Pick-up voltage, V DC (Initial) Max. 7.2 Drop-out voltage, V DC (Initial) Min. 1.0 Coil resistance, 22510% Nominal operating Nominal current, operating Power, mA mW 53.310% 640 Usable voltage range, VDC 10 to 16

* Other pick-up voltage types are also available. Please contact us for details.

CF
DIMENSIONS
16.5 .650 Max. 1.2 .047 (6-4 dia.) (6-.157 dia.) Land diameter

mm inch Recommended PC board pattern


(R1.5) 1.270.1 .050.004 5.080.1 .200.004 2.540.1 .100.004 (3) 5.080.1 (.118) .200.004

3.5 .138 0.25 .010 0.25 0.2 .010 .008 1.0 .039 *A 1.0 .039 0.3 Pre-soldering .012 1.0 .039 1.0 .039 0.3 .012

12.70.1 .500.004 6.350.1 .250.004 (0.8) (.031)

1.0 .039

12.7 .500

5.08 .200 JAPAN 2.54 5.08 .100 .200 3.81 .150

3.810.1 4-1.3 dia.0.1 4-.052 dia..004 .150.004 4-1.5 dia.0.1 4-.059 dia..004 7.620.1 10.160.1 .300.004 .400.004

7.62 .300

10.16 .400

Dimension: General tolerance Max. 1mm .039 inch: 0.1 .004 1 to 3mm .039 to .118 inch: 0.2 .008 Min. 3mm .118 inch: 0.3 .012

Schematic
NO COM1 NC COM2

* Dimensions (thickness and width) of terminal specied in this catalog is measured before pre-soldering. Intervals between terminals is measured at A surface level.

EXAMPLE OF CIRCUITS
Forward/reverse control circuits of DC motor for power window

NO 12 V DC NC

COM

COM

NO NC

SW A

SW B M : Power window motor

SW A OFF ON OFF

SW B OFF OFF ON

Motor Stop Forward Reverse

REFERENCE DATA
1-(1). Coil temperature rise (at room temperature)
Sample: CF2-12V, 6pcs. Measured potion: Inside the coil Contact carrying current: 10A, 15A, 20A Ambient temperature: Room temperature
100 20A Switching voltage, VDC Temperature rise, C 80 Temperature rise, C 15A 10A 60 80 20A 15A 60 10A 50 40 30 20 10 0

1-(2). Coil temperature rise (at 85C 185F)


Sample: CF2-12V, 6pcs. Measured potion: Inside the coil Contact carrying current: 10A, 15A, 20A Ambient temperature: 85C 185F
100

2. Max. switching capability (Resistive load, initial)

60

(N.O. side Room temperature)

40

40

20

20

12

14 16 Coil applied voltage, V

12

14 16 Coil applied voltage, V

10

20 30 40 Switching current, A

50

3. Ambient temperature and operating temperature range


40 Coil applied voltage, VDC 35 30

4. Distribution of pick-up and drop-out voltage


Sample: CF2-12V, 100pcs.
70 60 Frequency 50 40 30 Pick-up voltage Drop-out voltage

5. Distribution of operate and release time


Sample: CF2-12V, 100pcs. * With diode
60 50 Frequency 40 30 20 10 0 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 Operate and release time, ms Operate time Release time

25 20 15 10 5 0 40 20 Pick-up voltage (Cold start) 0 20 40 60 8085 100 120 Ambient temperature, C

20 10 0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 Voltage, V

CF
6-(1). Electrical life test (Motor free)
Sample: CF2-12V, 3pcs. Load: Inrush current: 30A, Steady current: 7A, Power window motor actual load (free condition) Switching frequency: (ON:OFF = 1s:5s) Ambient temperature: Room temperature

Change of pick-up and drop-out voltage


10 Pick-up and drop-out voltage, V 9

Change of contact resistance


50 Contact resistance, m

Circuit
Relay 1 Relay 2 1s 1s 3s 6s (1 cycle)

8 7 6 5 4 3 2 1 0 Drop-out voltage Max. X Min. Pick-up voltage Max. X Min.

40

30

20

10

Max. X Min. 0 10 No. of operations, 104 20

Resistive load

10

15
4

20

No. of operations, 10

Power window motor (free)

Load current waveform


Inrush current: 27A, Steady current: 8.4A Brake current: 15A 10A
200ms

6-(2). Electrical life test (Motor lock)


Sample: CF2-12V, 3pcs. Load: 20A 14V DC, Power window motor actual load (lock condition) Switching frequency: (ON:OFF = 1s:5s) Ambient temperature: Room temperature

Change of pick-up and drop-out voltage


10 Pick-up and drop-out voltage, V 9

Change of contact resistance


50 Contact resistance, m

Circuit
Relay 1 Relay 2 1s 1s 3s 6s (1 cycle)

8 7 6 5 4 3 2 1 0 Drop-out voltage Max. X Min. Pick-up voltage Max. X Min.

40

30

20

10

Max. X Min. 0 2.5 No. of operations, 104 5

M
Power window motor (lock)

0 No. of operations, 10
4

Load current waveform


5A 200ms

For Cautions for Use, see Relay Technical Information.