You are on page 1of 9

CR5-29 (415V,4kW,95-190m)

Contents:
CR 5-29 (96513392) ...................................................................................................................... Quotation text ................................................................................................................................ Quotation text incl. photo ............................................................................................................... Data sheet incl. curve .................................................................................................................... Pump curve ................................................................................................................................... Dimensional drawing ..................................................................................................................... Wiring diagram .............................................................................................................................. 2 2 4 6 7 8 9

Printed from Grundfos CAPS

1/9

Position

Qty.

Description

Single Price

CR 5-29 A-FGJ-A-E HQQE Product No.: 96513392 Vertical, non-self-priming, multistage, in-line, centrifugal pump for installation in pipe systems and mounting on a foundation. The pump has the following characteristics: - Impellers and intermediate chambers are made of Stainless steel DIN W.-Nr. 1.4301 DIN W.-Nr.. - Pump head and base are made of Cast iron. - The shaft seal has assembly length according to EN 12756. - Power transmission is via cast iron split coupling. - Pipework connection is via DIN flanges. The motor is a 3-phase AC motor. Liquid: Liquid temperature range: Technical: Speed for pump data: Rated flow: Rated head: Shaft seal: Approvals on nameplate: Curve tolerance: Materials: Pump housing:

Price on request

-20 .. 120 C

2917 rpm 5.7 m/h 150 m HQQE CE ISO 9906 Annex A

Impeller:

Cast iron EN-JL1030 DIN W.-Nr. A48-30 B ASTM Stainless steel 1.4301 DIN W.-Nr. 304 AISI

Installation: Maximum ambient temperature: 60 C Max pressure at stated temp: 25 / 120 bar / C 25 / -20 bar / C Flange standard: DIN Pipe connection: DN 25 / DN 32 Pressure stage: PN 16 / PN 25 Flange size for motor: FT130 Electrical data: Motor type: Efficiency class: Number of poles: Rated power - P2: Power (P2) required by pump: Mains frequency: Rated voltage: Rated current: Starting current: Cos phi - power factor: Rated speed: Motor efficiency at full load: Motor efficiency at 3/4 load: Motor efficiency at 1/2 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): Others: Net weight: Gross weight:
Printed from Grundfos CAPS

112MC 1 2 4 kW 4 kW 50 Hz 3 x 380-415 D V 8A 1120-1230 % 0,88-0,84 2910-2930 rpm 89 % 89-88 % 87-86 % IP55 F

65.9 kg 86.5 kg

2/9

Position

Qty.

Description

Single Price

Shipping volume:

0.2 m

Printed from Grundfos CAPS

3/9

Position

Qty.

Description

Single Price

CR 5-29 A-FGJ-A-E HQQE

Price on request

Note! Product picture may differ from actual product

Product No.: 96513392 Vertical, non-self-priming, multistage, in-line, centrifugal pump for installation in pipe systems and mounting on a foundation. The pump has the following characteristics: - Impellers and intermediate chambers are made of Stainless steel DIN W.-Nr. 1.4301 DIN W.-Nr.. - Pump head and base are made of Cast iron. - The shaft seal has assembly length according to EN 12756. - Power transmission is via cast iron split coupling. - Pipework connection is via DIN flanges. The motor is a 3-phase AC motor. Liquid: Liquid temperature range: Technical: Speed for pump data: Rated flow: Rated head: Shaft seal: Approvals on nameplate: Curve tolerance: Materials: Pump housing:

-20 .. 120 C

2917 rpm 5.7 m/h 150 m HQQE CE ISO 9906 Annex A

Impeller:

Cast iron EN-JL1030 DIN W.-Nr. A48-30 B ASTM Stainless steel 1.4301 DIN W.-Nr. 304 AISI

Installation: Maximum ambient temperature: 60 C Max pressure at stated temp: 25 / 120 bar / C 25 / -20 bar / C Flange standard: DIN Pipe connection: DN 25 / DN 32 Pressure stage: PN 16 / PN 25 Flange size for motor: FT130 Electrical data: Motor type: Efficiency class: Number of poles: Rated power - P2: Power (P2) required by pump: Mains frequency: Rated voltage: Rated current:
Printed from Grundfos CAPS

112MC 1 2 4 kW 4 kW 50 Hz 3 x 380-415 D V 8A

4/9

Position

Qty.

Description

Single Price

Starting current: Cos phi - power factor: Rated speed: Motor efficiency at full load: Motor efficiency at 3/4 load: Motor efficiency at 1/2 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): Others: Net weight: Gross weight: Shipping volume:

1120-1230 % 0,88-0,84 2910-2930 rpm 89 % 89-88 % 87-86 % IP55 F

65.9 kg 86.5 kg 0.2 m

Printed from Grundfos CAPS

5/9

Description Product name: Product No: EAN number: Technical: Speed for pump data: Rated flow: Rated head: Head max: Impellers: Shaft seal: Approvals on nameplate: Curve tolerance: Stages: Pump version: Model: Materials: Pump housing:

Value CR 5-29 A-FGJ-A-E HQQE 96513392 5700396639567

H (m) 180 160 140

CR 5-29 Q = 7.91 m/h H = 107 m

2917 rpm 5.7 m/h 150 m 198 m 29 HQQE CE ISO 9906 Annex A 29 A A

120 100 80 60 40 20 0 0 P (kW) 3 2 1 0


134 220

Eta pump = 59.7 % Eta pump+motor = 53.1 % 5 6 7 Q(m/h) P1 P2

Impeller:

Material code: Code for rubber: Installation: Maximum ambient temperature: Max pressure at stated temp: Flange standard: Connect code: Pipe connection: Pressure stage: Flange size for motor: Liquid: Liquid temperature range: Electrical data: Motor type: Efficiency class: Number of poles: Rated power - P2: Power (P2) required by pump: Mains frequency: Rated voltage: Rated current: Starting current: Cos phi - power factor: Rated speed: Motor efficiency at full load: Motor efficiency at 3/4 load: Motor efficiency at 1/2 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): Motor protec: Motor No: Others: Net weight: Gross weight: Shipping volume:

Cast iron EN-JL1030 DIN W.-Nr. A48-30 B ASTM Stainless steel 1.4301 DIN W.-Nr. 304 AISI A E

P2 = 3.88 kW P1 = 4.36 kW

60 C 25 / 120 bar / C 25 / -20 bar / C DIN FGJ DN 25 / DN 32 PN 16 / PN 25 FT130

-20 .. 120 C
1034

112MC 1 2 4 kW 4 kW 50 Hz 3 x 380-415 D V 8A 1120-1230 % 0,88-0,84 2910-2930 rpm 89 % 89-88 % 87-86 % IP55 F PTC 85D15413

372

G 1/2

19 X 24.5

100

75

20

100 141 250

35 180 220

4 X 13.5

+T

+T

+T

65.9 kg 86.5 kg 0.2 m

TO AMPLIFIER RELAY

L1

L2

L3

+T

+T

+T

TO AMPLIFIER RELAY

L1

L2

L3

Printed from Grundfos CAPS

IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 44082

140

89

6/9

96513392 CR 5-29
H (m) 200 CR 5-29 Q = 7.91 m/h H = 107 m

180

160

140

120

100

80

60

40

20 Eta pump = 59.7 % Eta pump+motor = 53.1 % 7 8 Q(m/h)

0 0 P (kW)

P1 4 P2

1 P2 = 3.88 kW P1 = 4.36 kW 7/9

0
Printed from Grundfos CAPS

96513392 CR 5-29
134 220

1034

372

G 1/2

19 X 24.5

100

75

20

100 141 250

35 180 220

4 X 13.5

Note! All units are in [mm] unless others are stated. Printed from Grundfos CAPS

140
8/9

89

96513392 CR 5-29

+T

+T

+T

TO AMPLIFIER RELAY

L1

L2

L3

+T

+T

+T

TO AMPLIFIER RELAY

L1

L2

L3

Note! All units are in [mm] unless others are stated. Printed from Grundfos CAPS

IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 44082

9/9

You might also like