b Compact CVS Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . 1 b Compact CVS MCCBs for Distribution Network . . . . . . . . . . . . . 2 b Compact CVS Unique Modular Ground Fault Protection . . . . . . 3 b Compact CVS Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 b Compact NSX Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . 6 b Compact NSX MCCBs for Distribution Network . . . . . . . . . . . . . 9 b Compact NSX MCCBs for Motor Protection . . . . . . . . . . . . . . . 13 b Compact NSX Earth Leakage Protection . . . . . . . . . . . . . . . . . 15 b Compact NSX Automatic Source Changeover System . . . . . . . 16 b Compact NS MCCBs for DC Network Protection . . . . . . . . . . . 18 b Compact NS MCCBs above 630A Manual Fixed . . . . . . . . . . . 19 b Compact NS MCCBs above 630A Electrical Fixed . . . . . . . . . . 20 b Compact NSX/NS Accessories . . . . . . . . . . . . . . . . . . . . . . . . . 21 b Easypact MCCBs for Distribution Network . . . . . . . . . . . . . . . . 24 b Easypact Accessories and Main Busbar . . . . . . . . . . . . . . . . . . 25 b Simpact NKS MCCBs for Distribution Network . . . . . . . . . . . . . 26 b Simpact NKS Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 b Simpact NKF 400/630A MCCB for Distribution Network . . . . . . 28 b Simpact NKF Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 b Masterpact NT/NW ACBs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 b Masterpact MVS Draw-out type ACBs . . . . . . . . . . . . . . . . . . . 33 b Masterpact MVS Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . 34 b Enerpact ACBs - NH Series . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 b Enerpact ACBs - Accessories & Spares . . . . . . . . . . . . . . . . . . . 36 b Interpact Switch Disconnectors . . . . . . . . . . . . . . . . . . . . . . . . 39 b Fupact Switch Disconnector and Accessories . . . . . . . . . . . . . 40

Compact CVS Range Overview

 2 3 4 5 6
16A - 800A, 3P & 4P Only three frame sizes Complete Range Ics=100% Icu Isolation with Positive Break Indication* Class II Front Face* Unique Double Break Contacts* CVS00 CVS60 CVS250 CVS400 CVS630 CVS800**

Breaking Capacity @380/45V

N 50kA F 36kA B 25kA


* 00 - 630A ** 35kA for Compact CVS 800A

Type of Trip Units

Thermal Magnetic Trip Unit


Available from 6A - 250A Overload Setting (Ir) 0.7 -  x In (New)

Electronic Trip Unit


Available from 400 - 630A Overload Setting (Ir) 0.5 -  x In Short Circuit Setting (Isd) 2 - 0 x Ir Adjustable neutral for 4 Pole MCCBs


Compact CVS
With Thermal Magnetic Trip Unit (TMD)

Moulded Case Circuit Breakers for Distribution Network


Ics = 100% Icu as per IS/IEC 60947-2 Suitable for Isolation Class II front face Adjustable thermal setting 0 .7 - 1 x In Single frame size up to 250A


Unit MRP [`]
LV510310N n LV510311N n LV510312N n LV510313N n LV510314N n LV510315N n LV510316N n LV510317N n

Breaking Capacity Icu as per IS/IEC 60947-2

Rated Current
16A 25A 32A 40A 50A 63A 80A 100A 125A 160A 200A 250A 16A 25A 32A 40A 50A 63A 80A 100A 125A 160A 200A 250A

Three Pole Reference


LV510300N n LV510301N n LV510302N n LV510303N n LV510304N n LV510305N n LV510306N n LV510307N n LV516308N n LV516309N n LV525310N n LV525311N n LV510330N n LV510331N n LV510332N n LV510333N n LV510334N n LV510335N n LV510336N n LV510337N n LV516338N n LV516339N n LV525340N n LV525341N n

Unit MRP Four Pole [`] Reference

2
6800

4900

25 kA

7450 10100 12600 15900

LV516318N n LV516319N n LV525320N n LV525321N n LV510340N n LV510341N n LV510342N n LV510343N n LV510344N n LV510345N n LV510346N n LV510347N n

8700 11700 16500 19000

3 4

6500

8600

36 kA

7700 10300 14500 16600

LV516348N n LV516349N n LV525350N n LV525351N n

9100 12100 17900 19800

5 6

With Electronic Trip Units (P Based)


Ics = 100% Icu as per IS/IEC 60947-2 Suitable for Isolation Class II front face Adjustable overload from 0 .5 - 1 x In Adjustable short circuit from 2 - 10 x Ir Adjustable neutral protection - N, N/2, OFF for 4 pole MCCB

Breaking Capacity Icu as per IS/IEC 60947-2


36 kA 50 kA

Rated Current
400A 630A 400A 630A

Three Pole Reference


LV540505N n LV563505N n LV540510N n LV563510N n

Unit MRP Four Pole [`] Reference


22500 24500 23500 26000 LV540506N n LV563506N n LV540511N n LV563511N n

Unit MRP [`]


26500 30700 29500 33900

With Thermal Magnetic Trip Unit (TMD)

Ics = 100% Icu as per IS/IEC 60947-2 Adjustable overload from 0 .8 - 1 x In Adjustable short circuit for each phase from 3 .5 - 10 x Ir

Breaking Capacity Icu as per IS/IEC 60947-2


35 kA 50 kA n NORMAL STOCK ITEMS

Rated Current
800A 800A

Three Pole Reference


LV580300 n LV580302 n

Unit MRP Four Pole [`] Reference


35000 36700 LV580301 n LV580303 n

Unit MRP [`]


37800 42500
W.E.F. January 20, 20

Compact CVS

Unique Modular Ground Fault Protection

Earth Fault Protection for Compact Series (CVS/NSX/NS) MCCBs


Modular Device for Compact NSX/CVS/NS Range Moulded Case Circuit Breakers Adjustable earth fault sensitivity selection 10 to 60% Adjustable time delay Inst / 0 .5 - 3 Sec . System healthiness check through LED indication Individual fault indication for OL,SC, EF when used with Compact NSX (Optional) Individual fault indication for OL/SC, EF when used with Compact CVS (Optional) Test facility to check healthiness of earth fault protection system without tripping MCCB Suitable for 3P3W & 3P4W electrical distribution network CVS 32,40,50,63,80,00 Reference
GFP11CT13P n GFP11CT14P n

 2 3 4 5 6

Ground Fault Protection


Description
3 Phase 3 Wire 3 Phase 4 Wire

Unit MRP CVS 25,60,200,250 [`] Reference


3960 4410 GFP12CT23P n GFP12CT24P n

Unit MRP [`]


4570 5120

Description
3 Phase 3 Wire 3 Phase 4 Wire

CVS 400,630 Reference


GFP13CT33P n GFP13CT34P n

Unit MRP CVS 800 [`] Reference


6825 7560 GFP14CT43P n GFP14CT44P n

Unit MRP [`]


8470 9500

Note: Kindly order one no . Shunt trip coil along with one Ground Fault Protection Module for CVS100 to 630 . (For price of shunt coil refer page 4) Order one auxiliary contact alongwith shunt coil for CVS800 (For price of CVS800 accessories refer page 5) .

Earth Fault Protection Selection Guide


Range
Compact CVS 100 Compact CVS 100 Compact CVS 160 Compact CVS 160 Compact CVS 250 Compact CVS 250 Compact CVS 400 Compact CVS 400 Compact CVS 630 Compact CVS 630 Compact CVS 800 Compact CVS 800

Poles
3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P

Relay Module Rated current


32, 40, 50, 63, 80, 100

Ground Fault Relay + CT Ref.


GFP11CT13P GFP11CT14P GFP12CT23P GFP12CT24P GFP12CT23P GFP12CT24P GFP13CT33P GFP13CT34P GFP13CT33P GFP13CT34P GFP14CT43P GFP14CT44P

125, 160, 200, 250

400, 630

800

Note: Can also be used with Compact NSX and Compact NS >=800A MCCB .

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

Compact CVS

Accessories for Compact CVS 00 - 630A


Auxiliary Contacts (Changeover) Multifunction
Description
OF or SD

Reference
29450 n

Unit MRP [`]


680

2 3 4 5 6

Voltage Releases
Description AC
110-130 V 50/60 Hz 220-240 V 50/60 Hz 380-415 V 50/60 Hz LV429386 n LV429387 n LV429388 n LV429390 n LV429392 n LV429393 n LV429394 n 1510 1510 LV429406 n LV429407 n LV429408 n LV429410 n LV429412 n LV429413 n LV429414 n 1900 1900

Shunt Release Reference

Unit MRP Undervoltage [`] Reference

Unit MRP [`]

DC
24 V 48 V 125 V 250 V

Rotary Handles
Description
Standard direct rotary handle Standard extended rotary handle

CVS 00/60/250 Reference


29337 n 29338 n

Unit MRP CVS 400/630 [`] Reference


950 1325 32597 n 32598 n

Unit MRP [`]


1270 1980

Locks & Interlocking Devices


Description CVS 00 - 630 Reference
29370 n 29371 n

Unit MRP [`]


350 500

Toggle Locking Device for  to 3 Padlocks (CVS 00 to 630)


By removable device By fixed device

Description

CVS 00/60/250 Reference


LV429344 n 41940 n 41950 n 31563SEI n 31564SEI n LV429329 n

Unit MRP CVS 400/630 [`] Reference


370 950 1410 420 550 375 LV432604 n 41940 n 41950 n 32492 n 32493 n LV432570 n

Unit MRP [`]


465 950 1410 1040 1385 500

Key Locking of Rotary Handles


Locking Device Ronis Keylocks (1 Lock + 1 Key set) Ronis Keylocks (2 Lock + 1 Key set)

Spreaders
3P (Set of 3) 4P (Set of 4)

Phase Barriers
3P/4P (Set of 6)

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

Compact CVS
Auxiliary/Alarms contacts
Description
Auxiliary Switch 1 C/O

Accessories for Compact CVS 800A

Reference
LV580075 n LV580076 n LV580077 n LV580078 LV580079 n

Unit MRP [`]


900 795 1040 1210

 2 3 4 5 6

Auxiliary Switch 2 C/O Alarm Switch 1 C/O Alarm Switch 2 C/O Alarm + Auxiliary Switch 1 C/O each

Voltage Releases
Description AC
110-130 V 50/60 Hz 220-240 V 50/60 Hz 380-415 V 50/60 Hz 440 V 50/60 Hz LV580060 LV580061 n LV580062 n LV580063 LV580064 LV580065 LV580066 LV580067 1200 1200 LV580070 LV580071 n LV580072 n 1420

Shunt Release Reference

Unit MRP Undervoltage [`] Reference

Unit MRP [`]

DC
24 V 48 V 110 V 220 V

Rotary Handles
Description
Standard direct rotary handle Standard extended rotary handle

Reference
LV580080 n LV580081 n

Unit MRP [`]


880 1320

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

Compact NSX Range Overview

 2
16A - 630A, 3P, 4P & 2P (3P Frame) Two frame size Voltage Rating upto 690V Isolation with Positive Break Indication

3 4

Breaking Capacity Ics=00% Icu @380/45V

NSX00

NSX60

NSX250

NSX400

NSX630

L 50kA S 00kA H 70kA N 50kA F 36kA B 25kA


NEW NEW

5 6

Type of Trip Units

Thermal Magnetic Trip Unit


Available from 6A - 250A Overload Setting (Ir) 0.7 -  x In (New) Short Circuit Setting (Im)
Fixed upto 60A Adjustable 5 - 0 x Ir (for 200A - 250A)

W.E.F. January 20, 20

Micrologic Trip Units (ASIC based)


(ASIC-Application Specific Integrated Circuit) Two different Microprocessors for Protection & Metering

 2 3 4 5 6
1I 2 LS0I 5 LSI 6 LSIG
Example

Identification of Micrologic Trip Unit


Protection Cases Measurement Application

2 NSX100-250 3 NSX400-630

A Ammeter E Energy Meter

---

G AB M Z

Distribution Generator Subsciber Motor 16Hz 2/3

Micrologic 1 .3 M Micrologic 2 .2 G Micrologic 2 .3 Micrologic 2 .3 M Micrologic 5 .2 A Micrologic 5 .3 E

400 or 630 A 100, 160 or 250 A 400 or 630 A 400 or 630 A 100, 160 or 250 A 400 or 630 A 400 or 630 A Ammerter Energy Energy

Motor Generator Distribution Motor Distribution Distribution Motor

LS0I LS0I LS0I LSI LSI

Micrologic 6 .3 E-M LSIG

I S0 S G

Instantaneous Short Time with Fixed Time Delay Short Time with Adjustable Time Delay Ground Fault

ULP Modules
FDM2 - Front Display Module
The front display module FDM121 is a panel mounted unit dedicated to display measurements (Current, Voltage, Power, Energy, Power Factor, THD etc .), operating assistance data (Contact wear indication, Load Profile, ON/OFF/Trip counter) and Last 17 fault trip/Alarm history with date and time stamping data received from MCCB .

 2 3 4 5

IFM - Interface Module


Interface module allows intelligent modular units (IMUs) in the ULP system to communicate using the Modbus protocol .These are DIN rail mounted modules .

The Compact NSX circuit breaker connects to the ULP system by means of the NSX Cord .The Compact NSX circuit breaker must be equipped with a BSCM and/or a Micrologic 5/6 Trip Unit .
NSX cord ULP cables

ULP cables are used to interconnect ULP modules within a single IMU . They have male RJ45 connectors at both ends and are available in several lengths .

ULP modules are interconnected by simple plug and play connection using ULP cables, without prior set-up .
W.E.F. January 20, 20

Compact NSX
With Thermal Magnetic Trip Unit (TMD)
Breaking Capacity Icu as per IEC 60947-2 Rated Current
16A 25A 32A 40A 25kA 50A 63A 80A 100A 125A 160A 16A 25A 32A 40A 36kA 50A 63A 80A 100A 125A

Moulded Case Circuit Breakers for Distribution Network


Ics = 100% Icu as per IEC 60947-2 Suitable for Isolation Adjustable thermal setting 0 .7 - 1 x In Transparent cover for trip unit as standard Single frame size up to 250A Breaking Capacity enhancement upto 150kA with a higher capacity upstream (Cascading) Exceptional current limiting < 6 x 105 A2S Three Pole Reference
LV429557 LV429556 n LV429555 n LV429554 n LV429553 LV429552 n LV429551 n LV429550 n LV430311 n LV430310 n LV429637 n LV429636 n LV429635 n LV429634 n LV429633 LV429632 n LV429631 n LV429630 n LV430631 n LV430630 n LV429847 LV429846 LV429845 n LV429844 n LV429843 LV429842 n LV429841 n LV429840 n LV430841 n LV430840 n LV429677 LV429676 LV429675 LV429674 LV429673 LV429672 n LV429671 LV429670 n LV430671 n LV430670 n 19500 21900 11700 13300 15700 9400 10000 12400 6800 9000 11400 6000

 2 3 4 5 6
50kA

Unit MRP Four Pole [`] Reference


LV429567 LV429566 LV429565 LV429564 LV429563 LV429562 n LV429561 LV429560 n LV430321 n LV430320 n LV429647 LV429646 LV429645 n LV429644 n LV429643 LV429642 n LV429641 n LV429640 n LV430641 n LV430640 n LV429857 LV429856 LV429855 LV429854 LV429853 LV429852 n LV429851 LV429850 n LV430851 LV430850 n LV429687 LV429686 LV429685 LV429684 LV429683 LV429682 LV429681 LV429680 LV430681 LV430680

Unit MRP [`]

8700

11300 13500

9800

14000 16200

160A 16A 25A 32A 40A 50A 63A 80A 100A 125A 160A 16A 25A 32A 40A 70kA 50A 63A 80A 100A 125A 160A

11900

15400 17600

14600

21500 23700

Adjustable Thermal/Magnetic
Trip Unit TMD Adjustable thermal 0 .7 - 1 x In Adjustable short-circuit 5 - 10 x Ir

Breaking Capacity Icu as per IEC 60947-2


25kA 36kA 50kA 70kA

Rated Current
200A 250A 200A 250A 200A 250A 200A 250A

Three Pole Reference


LV431111 LV431110 n LV431631 n LV431630 n LV431831 n LV431830 n LV431671 LV431670 n

Unit MRP Four Pole [`] Reference


14800 16800 16300 18300 18400 20400 23400 25400 LV431121 n LV431120 n LV431641 n LV431640 n LV431841 LV431840 n LV431681 LV431680

Unit MRP [`]


18300 19900 22000 23600 23900 25500 30300 31900
W.E.F. January 20, 20

Note: For higher Breaking Capacities (100kA and 150kA); for Generator Protection MCCB and other special application MCCB, contact our nearest Sales Office . n NORMAL STOCK ITEMS

Compact NSX

Moulded Case Circuit Breakers for Distribution Network

With Electronic Trip Units (P Based) Micrologic 2


Breaking Capacity Icu as per IEC 60947-2
25kA

Ics = 100% Icu as per IEC 60947-2 Suitable for Isolation Adjustable overload from 0 .36 - 1 x In Adjustable short circuit from 1 .5 - 10 x Ir Innovative front indication LED`s (Ready, Overload pre-alarm & Overload) Two frame sizes up to 630A Breaking Capacity enhancement upto 150kA with a higher capacity upstream (Cascading) Adjustable neutral protection - N, N/2,OFF for 4 Pole MCCB Three Pole Reference
LV429777 n LV429775 n LV430745 n LV431140 n LV429772 n LV429770 n LV430770 n LV431770 n LV432676 n LV432876 n LV429797 n LV429795 n LV430775 n LV431870 n LV432693 n LV432893 n LV429792 LV429790 LV430790 LV431790 LV432695 n LV432895 n

 2 3 4 5 6

Rated Current
40A 100A 160A 250A 40A 100A 160A 250A 400A 630A 40A 100A 160A 250A 400A 630A 40A 100A 160A 250A 400A 630A

Unit MRP Four Pole [`] Reference


10700 14100 17200 11500 15100 18700 22500 25100 14100 18400 20800 26000 27850 16400 24600 25800 31750 33000 LV429787 n LV429785 n LV430750 n LV431150 n LV429782 n LV429780 n LV430780 n LV431780 n LV432677 n LV432877 n LV429807 n LV429805 n LV430785 n LV431875 n LV432694 n LV432894 n LV429802 LV429800 LV430800 LV431800 LV432696 LV432896

Unit MRP [`]


14400 18100 24100 15500 20800 27800 28170 37590 17600 22200 29700 33800 41000 20300 28300 36100 42710 51550

36kA

50kA

70kA

Note: For higher Breaking Capacities (100kA and 150kA); for Generator Protection MCCB and other special application MCCB, contact our nearest Sales Office .

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

0

Compact NSX

Moulded Case Circuit Breakers for Distribution Network


Ics = 100% Icu as per IEC 60947-2 Suitable for Isolation Current measurements (Phase & neutral, Average, Highest of phases, Ground fault current, Maximeter / Minimeter, Current unbalance between phases) Adjustable overload from Ir 0 .36 to 1 x In and tr = 0 .5 - 16 s Adjustable short circuit from Isd 1 .5 - 10 x Ir and tsd I2tON/OFF 0 .1 - 0 .4s Adjustable earth fault 0 .4 - 1 x In (for In=40A) & 0 .2 - 1 x In (for In>40A) and tg I2tON/OFF 0 .1 - 0 .4s Instantaneous protection Ii 1 .5 x In - 15 x In (40 - 160A), 12 x In (250 - 400A) and 11 x In (630A) Innovative front indication LED`s (Ready, Overload pre-alarm & Overload) Fault distinction on the display of trip unit (type of fault, interrupted fault current and faulty phase) Zone Selective Interlocking (ZSI) as standard Breaking Capacity enhancement upto 150kA with a higher capacity upstream (Cascading) Adjustable neutral protection - N, N/2,OFF and oversized neutral (standard feature) for 4 Pole MCCB . Three Pole Reference
LV429014X62A40 LV429014X62A100 n LV430390X62A160 n LV431390X62A250 n LV429003X62A40 LV429003X62A100 n LV430403X62A160 n LV431403X62A250 n LV432413X63A400 n LV432813X63A630 n LV429006X62A40 LV429006X62A100 n LV430406X62A160 n LV431406X62A250 n LV432403X63A400 n LV432803X63A630 n LV429004X62A40 n LV429004X62A100 n LV430404X62A160 n LV431404X62A250 LV432404X63A400 LV432804X63A630

With Electronic Trip Units(P Based) Micrologic 6A

 2 3 4 5 6
Breaking Capacity Icu as per IEC 60947-2
25kA

Rated Current
40A 100A 160A 250A 40A 100A 160A 250A 400A 630A 40A 100A 160A 250A 400A 630A 40A 100A 160A 250A 400A 630A

Unit MRP Four Pole [`] Reference


28200 31350 34300 29000 32350 35800 40900 43500 31600 35650 37900 44400 46200 33900 41850 42900 50150 51400 LV429015X62A40 LV429015X62A100 LV430395X62A160 LV431395X62A250 LV429008X62A40 LV429008X62A100 n LV430408X62A160 n LV431408X62A250 n LV432415X63A400 n LV432815X63A630 LV429011X62A40 LV429011X62A100 LV430411X62A160 LV431411X62A250 LV432408X63A400 n LV432808X63A630 n LV429009X62A40 LV429009X62A100 LV430409X62A160 LV431409X62A250 LV432409X63A400 LV432809X63A630

Unit MRP [`]


31530 34870 40300 32630 37570 44000 46570 55990 34730 38970 45900 52200 59400 37430 45070 52300 61110 69950

36kA

50kA

70kA

Addition for High End Trip Units (From 00 to 630A)


Trip Units
Micrologic 6 .E

To be added to Prices of Micrologic 6A [`]


8600

Note: For arriving at the Reference of the MCCB with Micrologic 6E, please replace A with E in the above references .

Micrologic 6 E (Embedded Metering)

1 . 2 . 3 . 4 . 5 . 6 . 7 . 8 . 9 . 10 .

Current Measurements (Phase & neutral, Average, Highest of Phases, Ground Fault current, Maximeter/Minimeter, Current Unbalance between Phases) Voltage Measurements (Phase-Phase & Phase-neutral, Average, Ph-Ph & Ph-N voltage unbalance) Frequency Measurements Power Quality Indicator (Total Harmonic Distortion for Current and Voltage) Power Measurements (Active, Reactive and Apparent Power, total and per phase and Power Factor and cos (phi)) Demand Currents and Power Measurements (Demand Values, total & per phase, Maximum Demand) Energy Metering (Active, Reactive and Apparent energy, total and per phase) Indications, Alarms and Histories (Indication of fault types, Alarms for high/low threshold, operating histories & time stamped tables) Maintenance Indicators (Operation, trip and alarm counters; Operating Hours Counter; Contact wear; Load profile and thermal image) Communication (Modbus with add on module)

Note: For higher Breaking Capacities (100kA and 150kA), contact our nearest Sales Office. n NORMAL STOCK ITEMS
W.E.F. January 20, 20



Compact NSX
Type NA Switch Disconnector Unit

Moulded Case Circuit Breakers for Distribution Network


Ics = 100% Icu as per IEC 60947-2 Suitable for Isolation AC22A / AC23A Utilisation Categories Two frame sizes up to 630A Switch Disconnector are self-protected due to high set magnetic release .


Unit MRP [`]
8600 14600 22200 29500 38200

Rated Current
100A 160A 250A 400A 630A

Three Pole Reference


LV429629 LV430629 LV431629 LV432756 LV432956

Unit MRP Four Pole [`] Reference


6200 12100 18100 21000 21800 LV429639 LV430639 LV431639 LV432757 LV432957

2 3 4 5 6

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

2

Compact NSX
With Magnetic Trip Unit MA type

Moulded Case Circuit Breakers for Motor Protection

 2 3 4 5

Breaking Capacity Icu as per IEC 60947-2

Ics = 100% Icu as per IEC 60947-2 Suitable for Isolation Adjustable magnetic setting Im 6 -14 x In (2 .5 - 100A) & 9 - 14 x In (150 - 200A) Type - 2 Co-ordination charts upto 110 kW at 400V Breaking Capacity enhancement upto 150kA with a higher capacity upstream (Cascading) Adjustable neutral protection - N, N/2,OFF for 4 Pole MCCB Rated at 650C as per motor standards Three Pole Reference
LV429745 LV429744 LV429743 LV429742 LV429741 LV429740 n LV430830 n LV431748 LV429755 LV429754 LV429753 LV429752 LV429751 LV429750 n LV430832 n LV431752 LV429765 LV429764 LV429763 LV429762 LV429761 LV429760 LV430834 LV431756 20400 25300 12190 14200 20300 9890 10900 18200 7290

Rated Current
2 .5A 6 .3A 12 .5A 25A 50A 100A 150A 220A 2 .5A 6 .3A 12 .5A 25A 50A 100A 150A 220A 2 .5A 6 .3A 12 .5A 25A 50A 100A 150A 220A

Unit MRP [`]

36kA

50kA

70kA

6
With Micrologic .3M

Ics = 100% Icu as per IEC 60947-2 Suitable for Isolation Adjustable short circuit Isd = 5 -13 x In Front indication LED (Ready LED) Type - 2 Co-ordination charts upto 250 kW at 400V Rated at 650C as per motor standards

Breaking Capacity Icu as per IEC 60947-2


36kA 50kA 70kA

Rated Current
320A 500A 320A 500A 320A 500A

Three Pole Reference


LV432748 LV432948 LV432749 LV432949 LV432750 LV432950

Unit MRP [`]


20970 26150 24470 28850 30220 34050

Note: For higher Breaking Capacities (100kA and 150kA), contact our nearest Sales Office

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

3

Compact NSX

Moulded Case Circuit Breakers for Motor Protection


Ics = 100% Icu as per IEC 60947-2 Suitable for Isolation Adjustable overload Ir 0 .45 - 1 x In Adjustable short circuit Isd 5 - 13 x Ir Trip class selection: Class 5, Class 10 & Class 20 Phase unbalance or Phase Loss Type - 2 Co-ordination charts upto 315 kW at 400V Front indication LED`s (Ready & temperature rise alarm) Breaking Capacity enhancement upto 150kA with a higher capacity upstream (Cascading) Adjustable neutral protection - N, N/2,OFF for 4 Pole MCCB Rated at 650C as per motor standards Rated Current
25A 50A 100A

With Electronic Trip Units(P Based) Micrologic 2M

 2 3 4 5 6

Breaking Capacity Icu as per IEC 60947-2

Three Pole Reference


LV429828 LV429827 LV429825 LV430985 LV431160 LV432775 LV432975 LV429833 LV429832 LV429830 LV430988 LV431165 LV432776 LV432976 LV429838 LV429837 LV429835 LV430991 LV431170 LV432777 LV432977

Unit MRP [`]


10320 14430 20410 27670 30900 12920 17730 22510 31170 33600 15220 23930 27510 36920 38800

36kA

150A 220A 320A 500A 25A 50A 100A

50kA

150A 220A 320A 500A 25A 50A 100A

70kA

150A 220A 320A 500A

Note: For higher Breaking Capacities (100kA and 150kA), contact our nearest Sales Office

Addition for High End Trip Units (From 00 to 630A)


Trip Units
Micrologic 6 .E-M

To be added to Micrologic 2M [`]


27000

Note: For arriving at the Reference of the MCCB with Micrologic 6E-M, please replace A with EM for the references of MCCB with Micrologic 6A on page 11 .

Micrologic 6 E-M

In addition to Embedded Metering features of Micrologic 6E, the below Motor Application parameters are present in Micrologic 6E-M 1 . Overload protection: Ir 0 .45 - 1 x In 2 . Short circuit protection: Isd 5 - 13 x Ir 3 . Ground fault protection: Ig 0 .4 - 1 x In (for In=40A) & 0 .2 - 1 x In (for In>40A) and tg I2tON/OFF 0 .1 - 0 .4s 4 . Phase unbalance or Phase loss 5 . Trip class selection: Class 5, Class10, Class20 & Class30 6 . Cooling fan selection: self cooled or fan cooled motors 7 . Iunbalance: 10 - 40% of average current and time delay 0 .7s (starting) & 1 - 10s (normal operation) 8 . Locked Rotor: Ijam 1 - 8 x Ir or Ijam can be made OFF and tjam 1 - 30s 9 . Under-Load (under-current): Iund 0 .3 - 0 .9 x Ir or Iund can be made OFF and tund 1 - 200s 10 . Long Starts Ilong 1 - 8 x Ir or Ilong can be made OFF and tlong 1 - 200s 11 . Neutral: OFF or 0 .5 x Ir or oversized neutral standard 12 . Front indication LED`s (Ready & temperature rise alarm) 13 . Zone Selective Interlocking (ZSI) as standard 14 . Fault distinction on the display of trip unit (type of fault, interrupted fault current and faulty phase) n NORMAL STOCK ITEMS
W.E.F. January 20, 20

4

Compact NSX

Earth Leakage Protection

Earth Leakage Protection is obtained by: Fitting a VIGI Module on the Circuit Breakers Installing a Micrologic 7 .0 .A control unit (Compact NS800 - 3200A/ Masterpact NT/NW ACB) Using Vigirex Relays and separate Toroids or Rectangular Sensors

 2 3 4 5 6

VIGI Module Earth Leakage Device for Compact NSX Range Moulded Case Circuit Breakers

Compliance with Standards - IEC60947-2 appendix B, IEC 60255-4 and IEC60801-2 to 5 covering protection against nuisance tripping due to: Transient overvoltages, lightning strikes Switching of devices on the distribution system Electrostatic discharges and radio frequency disturbances Device can be equipped with multifunction aux contact of MCCB to remotely signal tripping due to earth fault Self powered - no aux supply required Direct acting device - no shunt/UV release required in MCCB MCCB Frame
NSX100/160 NSX100/160 NSX250 NSX400/630

Type
ME MH MH MB

Three Pole() Reference


LV429212 LV429210 n LV431535 LV432455

Unit MRP Four Pole [`] Reference


9450 13125 15225 39375 LV429213 LV429211 LV431536 LV432456

Unit MRP [`]


10080 13650 16275 40950

ME Type (NSX00/60)
Sensitivity - 300mA (fixed) Instantaneous time delay Fixed <40ms

MH Type (NSX00/60/250)
Sensitivity - adjustable 30mA - 300mA-1A-3A-10A Instantaneous time delay(ms) 0 - 60 (2) - 150 (2) - 310( 2)

MB Type (NSX400/630)
Sensitivity - adjustable 300mA-1A-3A-10A -30A Instantaneous time delay (ms) 0 - 60 - 150 - 310

(1) Vigi 3P modules may also be used on 3P circuit breaker used for single phase or two phase protection (2) If the sensitivity is set to 30mA, there is no time delay, whatever the time delay setting

Micrologic 7.0.A with NS800 - 3200 MCCBs Prices for the MCCBs with Micrologic 7 .0 .A available on request. Vigirex Relays

Vigirex Relays may be used to add external Earth Leakage Protection to Compact NS Circuit Breakers Sensitivity Adjustments from 30mA to 30A and time delay settings from (0-4 .5 seconds) Closed Toroid up to 630A (30 to 300mm in diameter), Split Toroid up to 250A (46 to 110mm in diameter) or Rectangular sensor up to 3200A 400Hz Distribution System Note: For further details, please contact our nearest Sales Office.

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

5

Compact NSX

Automatic Source Changeover System


BA controller (basic) Monitoring of Normal source & Automatic transfer Circuit breaker status indication on front of controller: ON, OFF & fault trip Voluntary transfer to Replacement source (e .g . energy management commands) UA controller (advanced) Monitoring of Normal source & Automatic transfer Circuit breaker status indication on front of controller: ON, OFF & fault trip Voluntary transfer to Replacement source (e .g . energy management commands) Delayed (adjustable) shutdown of generator set Load shedding & reconnection of non-priority loads Transfer to Replacement source if one of the phases of the Normal phase is absent During peak tariff period (energy management commands) forced operation on Normal source if Replacement source not operational

 2 3 4 5 6

With NSX00F - NSX630F 36kA 3P MCCB


Breaker for Normal Supply
NSX100F NSX160F NSX160F NSX250F NSX250F NSX250F NSX400F NSX400F NSX400F NSX400F NSX630F NSX630F NSX630F NSX630F

Breaker for Replacement Supply


NSX100F NSX100F NSX160F NSX100F NSX160F NSX250F NSX100F NSX160F NSX250F NSX400F NSX160F NSX250F NSX400F NSX630F

3P BA Controller Reference
LV4A3F100100B4 LV4A3F160100B4 LV4A3F160160B4 LV4A3F250100B4 LV4A3F250160B4 LV4A3F250250B4 LV4A3F400100B4* LV4A3F400160B4* LV4A3F400250B4* LV4A3F400400B4 LV4A3F630160B4* LV4A3F630250B4* LV4A3F630400B4 LV4A3F630630B4

Unit MRP 3P UA Controller [`] Reference


119480 123210 127580 134000 138480 144240 150620 156060 162710 177990 158940 166330 180770 183550 LV4A3F100100U4 LV4A3F160100U4 LV4A3F160160U4 LV4A3F250100U4 LV4A3F250160U4 LV4A3F250250U4 LV4A3F400100U4* LV4A3F400160U4* LV4A3F400250U4* LV4A3F400400U4 LV4A3F630160U4* LV4A3F630250U4* LV4A3F630400U4 LV4A3F630630U4

Unit MRP [`]


127070 130800 133570 141380 144470 151200 155970 161410 169340 183340 164290 171680 186120 188900

With NSX00F - NSX630F 36kA 4P MCCB


Breaker for Normal Supply
NSX100F NSX160F NSX160F NSX250F NSX250F NSX250F NSX400F NSX400F NSX400F NSX400F NSX630F NSX630F NSX630F NSX630F

Breaker for Replacement Supply


NSX100F NSX100F NSX160F NSX100F NSX160F NSX250F NSX100F NSX160F NSX250F NSX400F NSX160F NSX250F NSX400F NSX630F

4P BA Controller Reference
LV4A4F100100B4 LV4A4F160100B4 LV4A4F160160B4 LV4A4F250100B4 LV4A4F250160B4 LV4A4F250250B4 LV4A4F400100B4* LV4A4F400160B4* LV4A4F400250B4* LV4A4F400400B4 LV4A4F630160B4* LV4A4F630250B4* LV4A4F630400B4 LV4A4F630630B4

Unit MRP 4P UA Controller [`] Reference


129020 133330 139680 144570 148240 158240 156560 162540 170120 190130 172620 180200 200210 210290 LV4A4F100100U4 LV4A4F160100U4 LV4A4F160160U4 LV4A4F250100U4 LV4A4F250160U4 LV4A4F250250U4 LV4A4F400100U4* LV4A4F400160U4* LV4A4F400250U4* LV4A4F400400U4 LV4A4F630160U4* LV4A4F630250U4* LV4A4F630400U4 LV4A4F630630U4

Unit MRP [`]


136620 140820 147170 152060 155830 163590 161910 167890 175470 195480 177970 185550 205560 215640

* Downstream coupling accessories are not available . Notes: 1 . 2 MCCBs with Motor mechanism & Standard Trip Units . 2 . 4 Auxiliary contacts 2OF + 2SDE 3 . 1 Base Plate with IVE unit for mechanical & electrical interlocking 4 . 1 Downstream coupling accessory is supplied only when both the MCCB are of same Frame size . 5 . Control Unit UA or BA ATS upto 250A are provided with TMD type trip unit & for 400/630A with Micrologic 2 trip unit as standard . ATS with MCCBs of other breaking capacities & other versions of trip units can also be supplied . Prices available on request . Above given references with BA/UA controller are suitable for 415VAC control supply . UA controller with 220/240V AC is not available Replace suffix 4 by 2 for BA controller with 220/240V AC control supply. n NORMAL STOCK ITEMS
W.E.F. January 20, 20

6

Compact NSX

Automatic Source Changeover System


BA controller (basic) Monitoring of Normal source & Automatic transfer Circuit breaker status indication on front of controller: ON, OFF & fault trip Voluntary transfer to Replacement source (e .g . energy management commands)

 2 3 4 5 6

UA controller (advanced) Monitoring of Normal source & Automatic transfer . Circuit breaker status indication on front of controller: ON, OFF & fault trip Voluntary transfer to Replacement source (e .g . energy management commands) Delayed (adjustable) shutdown of generator set . Load shedding & reconnection of non-priority loads . Transfer to Replacement source if one of the phases of the Normal phase is absent During peak tariff period (energy management commands) forced operation on Normal source if Replacement source not operational

With NSX00N - NSX630N 50kA 3P MCCB


Breaker for Normal Supply
NSX100N NSX160N NSX160N NSX250N NSX250N NSX250N NSX400N NSX400N NSX400N NSX400N NSX630N NSX630N NSX630N NSX630N

Breaker for Replacement Supply


NSX100N NSX100N NSX160N NSX100N NSX160N NSX250N NSX100N NSX160N NSX250N NSX400N NSX160N NSX250N NSX400N NSX630N

3P BA Controller Reference
LV4A3N100100B4 LV4A3N160100B4 LV4A3N160160B4 LV4A3N250100B4 LV4A3N250160B4 LV4A3N250250B4 LV4A3N400100B4* LV4A3N400160B4* LV4A3N400250B4* LV4A3N400400B4 LV4A3N630160B4* LV4A3N630250B4* LV4A3N630400B4 LV4A3N630630B4

Unit MRP 3P UA Controller [`] Reference


125100 129590 134720 139140 144370 148890 157180 163380 170060 185490 165400 171550 187410 189340 LV4A3N100100U4 LV4A3N160100U4 LV4A3N160160U4 LV4A3N250100U4 LV4A3N250160U4 LV4A3N250250U4 LV4A3N400100U4* LV4A3N400160U4* LV4A3N400250U4* LV4A3N400400U4 LV4A3N630160U4* LV4A3N630250U4* LV4A3N630400U4 LV4A3N630630U4

Unit MRP [`]


132700 137190 140720 146520 150370 155840 162530 168730 175410 190840 170750 176900 192760 194690

With NSX00N - NSX630N 50kA 4P MCCB


Breaker for Normal Supply
NSX100N NSX160N NSX160N NSX250N NSX250N NSX250N NSX400N NSX400N NSX400N NSX400N NSX630N NSX630N NSX630N NSX630N

Breaker for Replacement Supply


NSX100N NSX100N NSX160N NSX100N NSX160N NSX250N NSX100N NSX160N NSX250N NSX400N NSX160N NSX250N NSX400N NSX630N

4P BA Controller Reference
LV4A4N100100B4 LV4A4N160100B4 LV4A4N160160B4 LV4A4N250100B4 LV4A4N250160B4 LV4A4N250250B4 LV4A4N400100B4* LV4A4N400160B4* LV4A4N400250B4* LV4A4N400400B4 LV4A4N630160B4* LV4A4N630250B4* LV4A4N630400B4 LV4A4N630630B4

Unit MRP 4P UA Controller [`] Reference


133610 137190 142810 149000 151940 161230 164880 170130 178280 202180 177840 185980 209880 217580 LV4A4N100100U4 LV4A4N160100U4 LV4A4N160160U4 LV4A4N250100U4 LV4A4N250160U4 LV4A4N250250U4 LV4A4N400100U4* LV4A4N400160U4* LV4A4N400250U4* LV4A4N400400U4 LV4A4N630160U4* LV4A4N630250U4* LV4A4N630400U4 LV4A4N630630U4

Unit MRP [`]


141210 144680 150300 156490 159540 166580 170230 175480 183630 207530 183190 191330 215230 222930

* Downstream coupling accessories are not available . Notes: 1) 2 MCCBs with Motor mechanism & Standard Trip Units . 2) 4 Auxiliary contacts 2OF + 2SDE 3) 1 Base Plate with IVE unit for mechanical & electrical interlocking 4) 1 Downstream coupling accessory is supplied only when both the MCCB are of same Frame size . 5) Control Unit UA or BA ATS upto 250A are provided with TMD type trip unit & for 400/630A with Micrologic 2 trip unit as standard . ATS with MCCBs of other breaking capacities & other versions of trip units can also be supplied . Prices available on request . Above given references with BA/UA controller are suitable for 415V AC control supply . UA controller with 220/240V AC is not available Replace suffix 4 by 2 for BA controller with 220/240V AC control supply.

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

7

Compact NS

MCCB for DC Network Protection

Compact NS Range Moulded Case Circuit Breakers for DC Network Protection


Available from 16 - 630A in 1P, 2P, 3P & 4P Range Protection for 750V DC Networks**, 100kA - Icu Level

Breaking Capacity [Icu] as per IEC 60947-2

[In] Rated Current


100 A 160 A 250 A 400 A 400 A 630 A 630 A 630 A

Type Of Trip Unit


TM100DC TM160DC TM250DC MP1 MP2 MP1 MP2 MP3

Reference
INA_DC90640 INA_DC91640 INA_DC92640 32742 32743 32942 32943 32944

Unit MRP [`]


9900 17800 26000 32000

 2 3 4 5 6

100kA

36000

** 250VDC Per Pole . 750VDC with 3 Pole MCCBs Prices for 1P, 2P & 4P on request Note: A detailed selection chart for MCCB selection for DC Network is available . Please contact our local Sales Office for details.

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

8

Compact NS

MCCB for Distribution Network above 630A Manual Fixed


Single frame size from 630b to 1600A Unique common auxiliaries switches from 100A to 1600A Breaking Capacity as high as 150kA Category B MCCBs

With Micrologic Trip Units (Common for ACBs & MCCBs) - Unique Feature of Schneider Electric MCCBs

 2 3 4 5 6

With Micrologic 2.0 Manual Fixed

LED overload alarm indicator Test facility Adjustable neutral protection - N, N/2, OFF for 4 Pole MCCBs Breaking Capacity Icu as per IEC 60947-2 Rated Current [A]
800 1000 1250 800 70kA 1000 1250

Three Pole Reference


INA_3P33466D n INA_3P33472D INA_3P33478D INA_3P33467D INA_3P33473D INA_3P33479D INA_3P33466E n INA_3P33472E n INA_3P33478E n INA_3P33467E INA_3P33473E INA_3P33479E

Unit MRP Four Pole [`] Reference


42360 54060 64560 51560 67760 81160 44100 55800 66300 53300 69500 82900 INA_4P33469D INA_4P33475D INA_4P33480D INA_4P33470D INA_4P33476D INA_4P33481D INA_4P33469E n INA_4P33475E n INA_4P33480E INA_4P33470E INA_4P33476E INA_4P33481E

Unit MRP [`]


54760 77560 98060 65260 101060 111260 56500 79300 99800 67000 102800 113000

With Direct Rotary Handle


50kA

With Extended Rotary Handle


50kA

800 1000 1250 800

70kA Remarks: Trip Unit Micrologic 2 .0 Adjustable overload (Ir) 0 .4 - 1 x In Short circuit (Instantaneous)1 .5 - 10 x Ir

1000 1250

With Micrologic 6.0.A Manual Fixed


LED overload alarm indicator Test facility Adjustable neutral protection - N, N/2, OFF With ammeter display & bargraph ## (Bargraph is unique feature of Schneider MCCB) Zone Selective Interlocking Communication optional Individual fault indication by LED Breaking Capacity Icu as per IEC 60947-2 Rated Current [A]
800 1000 1250 800 70kA 1000 1250

Three Pole Reference


INA_3P96466D INA_3P96472D INA_3P96478D INA_3P96467D INA_3P96473D INA_3P96479D INA_3P96466E INA_3P96472E INA_3P96478E INA_3P96467E INA_3P96473E INA_3P96479E

Unit MRP Four Pole [`] Reference


62360 73860 84260 69760 88460 103060 64100 75600 86000 71500 90200 104800 INA_4P96469D INA_4P96475D INA_4P96480D INA_4P96470D INA_4P96476D INA_4P96481D INA_4P96469E INA_4P96475E INA_4P96480E INA_4P96470E INA_4P96476E INA_4P96481E

Unit MRP [`]


71760 94660 116460 80060 116460 130060 73500 96400 118200 81800 118200 131800

With Direct Rotary Handle


50kA

With Extended Rotary Handle


800 50kA 1000 1250 800 70kA Remarks:Trip Unit Micrologic 6 .0 .A Parameter Ir tr Isd tsd Ii Ig tg Description Adjustable Overload Current Adjustable Overload time delay Adjustable Short Circuit Current Adjustable Short Circuit time delay Adjustable Instantaneous Current Adjustable Earth Fault Current Adjustable Earth Fault time delay Setting 0 .4 - 1 x In 0 .5 - 24 sec 1 .5 - 10 x Ir 0 .1 - 0 .4sec & OFF (I2t ON/OFF) 2 - 15 x In & OFF 0 .2 - In (for <1250A) / 500 - 1200A (for >=1250A) 0 .1 - 0 .4sec & OFF (I2t ON/OFF) 1000 1250

## Display shows readings of I1,I2,I3, In & Earth Fault Current Value . Also Maximeters of Three Phase Currents are stored & displayed . LED bargraph shows the % loading on each phase Note: For above MCCB with trip unit Micrologic 5.0, 5.0A, 5.0P, 6.0P and MCCB with higher breaking capacities, contact our nearest Sales Office Functionality of all the above Micrologic is same as that of Masterpact NT/NW ACB. n NORMAL STOCK ITEMS
W.E.F. January 20, 20

9

Compact NS

MCCB for Distribution Network above 630A Electrical Fixed


Single frame size from 630b to 1600A Unique common auxiliaries switches from 100A to 1600A . Typical design of Shunt, Closing & U/V coil for NS>=630A MCCB & Masterpact ACB Breaking Capacity as high as 150kA Category B MCCBs

With Micrologic Trip Units ( Common for ACBs & MCCBs) - Unique Feature of Schneider Electric MCCBs

With Micrologic 2.0 Electrical Fixed


LED overload alarm indicator Test facility Adjustable neutral protection - N, N/2,OFF for 4 Pole MCCBs Breaking Capacity Icu as per IEC 60947-2 Rated Current [A]
800 1000 1250 800 70kA 1000 1250

 2 3 4 5 6

Three Pole Reference


INA_3P93280_20 INA_3P93290_20 INA_3P93300_20 INA_3P93281_20 INA_3P93291_20 INA_3P93301_20 INA_3P93280_40 INA_3P93290_40 INA_3P93300_40 INA_3P93281_40 INA_3P93291_40 INA_3P93301_40

Unit MRP Four Pole [`] Reference


61500 74000 84300 68700 86400 100900 61500 74000 84300 68700 86400 100900 INA_4P93284_20 INA_4P93294_20 INA_4P93304_20 INA_4P93285_20 INA_4P93295_20 INA_4P93305_20 INA_4P93284_40 INA_4P93294_40 INA_4P93304_40 INA_4P93285_40 INA_4P93295_40 INA_4P93305_40

Unit MRP [`]


72000 98000 122800 81200 113400 132100 72000 98000 122800 81200 113400 132100

For Control Voltage 220/240V AC


50kA

For Control Voltage 45V AC


50kA

800 1000 1250 800

70kA Remaks: Trip Unit Micrologic 2 .0 Adjustable overload (Ir) 0 .4 - 1 x In Short circuit (instantaneous)1 .5 - 10 x Ir

1000 1250

With Micrologic 6.0.A Electrical Fixed


LED overload alarm indicator Test facility Adjustable neutral protection - N, N/2, OFF With ammeter display & bargraph ## (Bargraph is unique feature of Schneider MCCB) Zone Selective Interlocking Communication optional Individulal fault indication by LED Breaking Capacity Icu as per IEC 60947-2 Rated Current [A]
800 1000 1250 800 70kA 1000 1250

Three Pole Reference


INA_3P96280_20 INA_3P96290_20 INA_3P96300_20 INA_3P96281_20 INA_3P96291_20 INA_3P96301_20 INA_3P96280_40 INA_3P96290_40 INA_3P96300_40 INA_3P96281_40 INA_3P96291_40 INA_3P96301_40

Unit MRP Four Pole [`] Reference


81200 95700 103300 88500 108300 119700 81200 95700 103300 88500 108300 119700 INA_4P96284_20 INA_4P96294_20 INA_4P96304_20 INA_4P96285_20 INA_4P96295_20 INA_4P96305_20 INA_4P96284_40 INA_4P96294_40 INA_4P96304_40 INA_4P96285_40 INA_4P96295_40 INA_4P96305_40

Unit MRP [`]


90500 118700 141500 100900 133200 150800 90500 118700 141500 100900 133200 150800

For Control Voltage 220/240V AC


50kA

For Control Voltage 45VAC


50kA

800 1000 1250 800

70kA Remarks: Trip Unit Micrologic 6 .0 .A Parameter Ir tr Isd tsd Ii Ig tg Description

1000 1250

Setting 0 .4 - 1 x In 0 .5 - 24 sec 1 .5 - 10 x Ir 0 .1 - 0 .4sec & OFF (I2t ON/OFF) 2 - 15 x In & OFF 0 .2 - In (for <1250A) / 500 - 1200A (for >=1250A) 0 .1 - 0 .4sec & OFF (I2t ON/OFF)

Adjustable Overload Current Adjustable Overload time delay Adjustable Short Circuit Current Adjustable Short Circuit time delay Adjustable Instantaneous Current Adjustable Earth Fault Current Adjustable Earth Fault time delay

## Display shows Readings of I1,I2,I3, In & Earth Fault Current Value . Also Maximeters of Three Phase Currents are stored & displayed . LED bargraph shows the % loading on each phase Note: For above MCCB with trip unit Micrologic 5.0, 5.0A, 5.0P, 6.0P and MCCB with higher breaking capacities, contact our nearest Sales Office Functionality of all the above Micrologic is same as that of Masterpact NT/NW ACB. n NORMAL STOCK ITEMS
W.E.F. January 20, 20

20

Compact NSX

Accessories


Description Reference Unit MRP [`]
680 810 510 2070 2000

2 3 4 5

Auxiliary Contacts (Changeover) Multifunction


OF or SD or SDE or SDV OF or SD or SDE or SDV low level SDE adaptor for trip unit TM or MA or Micrologic 2 $$ 29450 n 29452 LV429451 n LV429532 n LV429424

SDx Output Module for Micrologic


SDx module 24/415 V AC/DC

SDTAM Contactor Tripping Module for Micrologic 2- M/6 E-M


SDTAM 24/415 V AC/DC overload fault indication

Voltage Releases
Type Voltage
24 V AC 50/60 Hz 48 V 110-130 V 220-240 V 380-415 V 525V 12 V 24 V 30V DC 48 V 60V 125 V 250 V

Shunt Release Reference


LV429384 LV429385 LV429386 n LV429387 n LV429388 n LV429389 LV429382 LV429390 n LV429391 LV429392 LV429383 LV429393 LV429394

Unit MRP Undervoltage [`] Reference


LV429404 LV429405 1510 LV429406 n LV429407 n LV429408 n LV429409 LV429402 LV429410 n LV429411 1510 LV429412 LV429403 LV429413 LV429414

Unit MRP [`]

1900

1900

6
Motor Mechanism
Type Voltage

NSX00/60 Reference
LV429440 LV429433 LV429434 n LV429435 LV429435 LV429436 LV429437 LV429438 LV429439

Unit MRP NSX250 [`] Reference


LV431548 LV431540 12550 LV431541 n LV431542 LV431542 LV431543 13500 LV431544 LV431545 LV431546
()

Unit MRP NSX400/630 [`] Reference


LV432639 LV432640 13600 LV432641 n LV432642 n LV432647 LV432643 14500 LV432644 LV432645 LV432646 22470 LV432652 n

Unit MRP [`]

Motor Mechanism Modules with SDE adaptor ()


48-60 V AC 50/60 Hz 110-130 V 220-240 V 380-415 V 440-480 V 24-30 V DC 48-60 V 110-130 V 250 V AC 50/60 Hz 220-240 V 50/60 Hz

22800

22800

Communicating Motor Mechanism Modules with SDE adaptor


LV429441 20330

LV431549 n

30495

(1) With every Motor Mechanism, please order 1 no . auxiliary contact additionally . For other voltages of motor mechanism please consult Schneider Electric . $$ To be considered alongwith SDE contact for MCCB with TMD/MA ./Micrologic 2 protection .

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

2

Compact NSX

Accessories


Description NSX00/60/50 Reference
LV431563 n LV431564 n LV429329 n LV429369 LV429354 29349 LV429344 n 41940 n 41950 n 42888 42878 LV429449 LV429513 n

Unit MRP NSX400/630 [`] Reference


420 520 375 3730 3730 10000 370 950 1410 1670 3510 2000 310 32492 n 32493 n LV432570 n LV432621 LV432614 32609 LV432604 n 41940 n 41950 n 42888 42878 LV432649 41940 n 42888 LV432513 n

Unit MRP [`]


1040 1385 500 5040 4040 16280 465 950 1410 1670 3510 500 950 1670 415

Spreaders & Phase Barrier


Spreaders *(Set Of 3) 3P Spreaders *(Set Of 4) 4P Phase Barrier (Set of 6)

2 3 4 5 6

Interlocking
For Breaker with Rotary Handle For Breaker with Toggle Mechanical Interlocking with Base Plate

Locking of Rotary Handle**


Locking Device Ronis Keylock (1 Lock + 1 Key set) Ronis Keylock (2 Locks + 1 Key set) Profalux Keylock (1 Lock + 1 Key set) Profalux Keylock (2 Locks + 1 Key set)

Locking of Motor Mechanism**


Keylock adaptor + Ronis keylock (special) Locking Device Ronis Keylock Profalux Keylock Torque Limiting Screws (Set of 12)

Monitoring and Control, test tools- Compact and NSX00 - 630


Monitoring and Control (Remote Operation)
Description NSX00 to 630 Reference
TRV00121 n LV434200 LV434201 n

Unit MRP [`]


8500 1560 1700

ULP Display Module


Switchboard front display module FDM121

ULP Wiring Accessories


NSX cord L = 0 .35 m NSX cord L = 1 .3 m

Power Supply Modules


External power supply module 24 V DC- A OVC IV 24-30 V DC 48-60 V DC 100-125 V AC 110-130 V AC 200-240 V AC 380-415 V AC Pocket battery for Micrologic NSX100-630 54440 54441 54442 54443 54444 n 54445 LV434206 12000 11100 12500

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

22

Compact NSX/NS

Accessories


Description NSX00/60/250 Reference
LV429337 n LV429338 n LV429289 n LV429290 n

Unit MRP NSX400/630 [`] Reference


890 1430 6740 8690 LV432597 n LV432598 n LV432538 n LV432539 n

Unit MRP [`]


1340 2580 15650 19220

2 3 4 5 6

Rotary Handles
Standard direct black handle Standard extended rotary handle

Plug in Base (Complete Kit)


3 Pole 4 Pole

Draw-Out Chassis Kit


3 Pole Plug In base Chassis Side Plate for base Chassis Side Plate for breaker

LV429289 n LV429282 n LV429283 n LV429290 n LV429282 n LV429283 n

6740 4000 4000 8690 4000 4000

LV432538 n LV432532 n LV432533 n LV432539 n LV432532 n LV432533 n

15650 5300 5300 19220 5300 5300

4 Pole Plug In base Chassis Side Plate for base Chassis Side Plate for breaker

Plug In / Withdrawable version Accessories


Automatic Auxillairy Connectors 1 9-wire fixed connector (for base)
1 9-wire moving connector (for circuit breaker)

LV429273 LV429274 LV429275 LV429272

600 520 245 1555

LV429273 LV432523 LV432525 LV429272

600 520 285 1555

1 support for 2 moving connectors Manual Auxillary Connectors 9-wire manual auxiliary connector (fixed + moving)

Note: Above auxiliary connectors to be used with Plug-in and Withdrawable MCCB when Auxiliary Contact, Shunt, UnderVoltage or Motor Mechanism is used .

For Compact NS630b - 600A


Type Voltage Shunt Release Reference
33659 33660 33661 33662 n 33664 33659 33660 33661 33662 n 4100 4100

Unit MRP Undervoltage [`] Reference


33668 33669 33670 33671 n 33673 n 33668 33669 33670 33671 n

Unit MRP [`]

Voltage Releases
24 V AC 50/60 Hz 48 V 110-130 V 220-240 V 380-415 V 24 V DC 48 V 125 V 250 V

4200

4200

Description
Spreaders *(Set of 3) 3P Spreaders *(Set of 4) 4P ** Locking device must be ordered for each keylock

NS630b to 600 Reference


33622 n 33623

Unit MRP [`]


5150 6870

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

23

Easypact
With Thermal Magnetic Trip Unit (TMD)

Moulded Case Circuit Breakers for Distribution Network

Conforms to IEC60947-2 Suitable for isolation Two frame sizes upto 250A Snap fitted accessories Adapted in Easypact Busbar system


Three Pole Reference
EZC100F3015 n EZC100F3020 n EZC100F3025 n EZC100F3032 n EZC100F3040 n EZC100F3050 n EZC100F3063 n EZC100F3080 n EZC100F3100N n EZC100N3015 n EZC100N3020 n EZC100N3025 n EZC100N3032 n EZC100N3040 n EZC100N3050 n EZC100N3063 n EZC100N3080 n EZC100N3100 n EZC250F3125N n EZC250F3150N n EZC250F3160N n EZC250F3175N n EZC250F3200N n EZC100H3015 n EZC100H3020 n EZC100H3025 n EZC100H3032 n EZC100H3040 n EZC100H3050 n EZC100H3063 n EZC100H3080 n EZC100H3100 n 4370 4800 5200 6800 3500 2450

Breaking Capacity Icu as per IEC 60947-2

Rated Current
15A 20A 25A 32A

Unit MRP [`]

2 3 4 5 6

10 kA

40A 50A 63A 80A 100A 15A 20A 25A 32A

15 kA

40A 50A 63A 80A 100A 125A 150A

18 kA

160A 175A 200A 15A 20A 25A 32A

30 kA

40A 50A 63A 80A 100A

Breaking Capacity Icu as per IEC 60947-2


30 kA

Rated Current
63A 80A 100A

Four Pole Reference


EZC100H4063 n EZC100H4080 n EZC100H4100 n

Unit MRP [`]


5000

Note: Easypact MCCBs are available upto 400A 3P/4P. Kindly contact our nearest Sales Office for further details.

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

24

Easypact
Description

Accessories

EZC00 Reference
EZAUX10 n EZAUX01 n EZAUX11 n EZASPDR3P n EZASPDR4P n EZAROTDS n

Unit MRP EZC250 [`] Reference


590 900 190 250 1030 Not available for 250A EZESPDR3P n EZEAX n EZEAL n

Unit MRP [`]

Auxiliary Contacts (Changeover) Multifunction


Auxiliary Switch 1 C/O

 2 3 4 5 6

Alarm Switch 1 C/O Alarm - Auxiliary Switch

680

Spreaders
Spreaders *(Set Of 3) 3P Spreaders *(Set Of 4) 4P 240

Rotary Handle
Standard black handle

Shunt Release
AC
100-130 V 200-277 V 380-480 V EZASHT100AC n EZASHT200AC n EZASHT380AC n EZASHT024DC n EZASHT048DC n 1080 1080 EZESHT100AC EZESHT200AC n EZESHT400AC EZESHT024DC EZESHT048DC 1510

DC

24 V 48 V

1510

Under Voltage Release


AC
110-130 V 200-240 V 277 V 380-415 V 440-480 V EZAUVR110AC EZAUVR200AC n EZAUVR277AC EZAUVR380AC EZAUVR440AC n EZAUVR024DC EZAUVR048DC EZAUVR125DC 2060 2060

DC

24 V 48 V 125 V

Main Busbar
Easypact Range Busbar Systems Easypact MCCBs used with Easypact Busbar Systems offers standard product for your distribution panel needs Available for 250A, 400A & 630A main incoming current Available for 4,6,8 & 12 ways(3-pole) Easypact 100A (max) 400 & 630A systems can accept an additional 2 or 4 compact NS outgoing MCCB Designed and tested to meet IEC 80438-1 requirements [In] Rated Current Description
EZ busbar 250A 4ways EZ busbar 250A 6ways EZ busbar 250A 8ways EZ busbar 250A 10ways EZ busbar 250A 12ways EZ busbar 400A 4ways EZ busbar 400A 6ways EZ busbar 400A 8ways EZ busbar 400A 10ways EZ busbar 400A 12ways EZ busbar 630A 4ways EZ busbar 630A 6ways EZ busbar 630A 8ways EZ busbar 630A 10ways EZ busbar 630A 12ways

Reference
EZB250W04 EZB250W06 EZB250W08 EZB250W10 EZB250W12 EZB400W04 EZB400W06 EZB400W08 EZB400W10 EZB400W12 EZB630W04 EZB630W06 EZB630W08 EZB630W10 EZB630W12

Unit MRP [`]


6000 7000 8500 9500 10500 7500 8500 9500 12500 13750 9000 10000 12250 13900 16400

250 A

400 A

630 A

Branch Extention for Compact NS


[In] Rated Current
250 A

Description
EZ busbar 250A 4ways EZ busbar 250A 6ways

Reference
EZB250W04 EZB250W06

Unit MRP [`]


6000 7000

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

25

Simpact NKS
AC MCCB
Fixed Thermal Magnetic Trip Unit (TMD) Breaking Capacity Icu as per IEC 60947-2

Moulded Case Circuit Breakers for Distribution Network

Rated Current
10A 15A 20A 25A 30A 32A 40A 50A 60A 63A 75A 90A 100A 110A 125A 140A 150A 160A 175A 200A

Single Pole Reference


NKS100R010AC1P NKS100R015AC1P NKS100R020AC1P NKS100R025AC1P NKS100R030AC1P NKS100R032AC1P NKS100R040AC1P NKS100R050AC1P NKS100R060AC1P NKS100R063AC1P NKS100R075AC1P NKS100R090AC1P NKS100R100AC1P n NKS200R110AC1P NKS200R125AC1P NKS200R140AC1P NKS200R150AC1P NKS200R160AC1P NKS200R175AC1P NKS200R200AC1P

Unit MRP Three Pole [`] Reference


NKS100R010AC3P NKS100R015AC3P NKS100R020AC3P NKS100R025AC3P NKS100R030AC3P NKS100R032AC3P n 975 NKS100R040AC3P n NKS100R050AC3P n NKS100R060AC3P NKS100R063AC3P n NKS100R075AC3P n NKS100R090AC3P NKS100R100AC3P n NKS160R110AC3P NKS160R125AC3P n NKS160R140AC3P 1375 NKS160R150AC3P n NKS160R160AC3P n NKS200R175AC3P n NKS200R200AC3P n

Unit MRP [`]

 2 3 4 5 6

1550

10 kA

3200

3400

4500

DC MCCB
Fixed Thermal Magentic Settings Breaking Capacity Icu as per IEC 60947-2 Rated Current
10A 15A 20A 5 kA 125VDC L/R = 10ms 30A 40A 50A 60A 75A 100A

One Pole Reference


NKS100R010DC1P NKS100R015DC1P NKS100R020DC1P NKS100R030DC1P NKS100R040DC1P NKS100R050DC1P NKS100R060DC1P NKS100R075DC1P NKS100R100DC1P

Unit MRP [`]

1155

DC MCCB
Fixed Thermal Magentic Settings Breaking Capacity Icu as per IEC 60947-2 Rated Current
10A 15A 20A 25A 30A 40A 50A 10 kA 250VDC L/R = 10ms 60A 75A 100A 110A 125A 140A 150A 160A 175A 200A

Two Pole Reference*


NKS100R010DC2P NKS100R015DC2P NKS100R020DC2P NKS100R025DC2P NKS100R030DC2P NKS100R040DC2P NKS100R050DC2P NKS100R060DC2P NKS100R075DC2P NKS100R100DC2P n NKS160R110DC2P NKS160R125DC2P n NKS160R140DC2P NKS160R150DC2P NKS160R160DC2P NKS200R175DC2P NKS200R200DC2P

Unit MRP Three Pole [`] Reference


NKS100R010DC3P NKS100R015DC3P NKS100R020DC3P NKS100R025DC3P 3465 NKS100R030DC3P NKS100R040DC3P NKS100R050DC3P NKS100R060DC3P NKS100R075DC3P NKS100R100DC3P NKS160R110DC3P NKS160R125DC3P 6615 NKS160R140DC3P NKS160R150DC3P NKS160R160DC3P 6930 NKS200R175DC3P NKS200R200DC3P

Unit MRP [`]

3959

7266

7938

Note: *2 Pole MCCB shall be in 3P dimensions .


n NORMAL STOCK ITEMS

Spreaders are supplied as standard with NKS100R above & including 63A . For spreaders below 63A consider additional prices
W.E.F. January 20, 20

26

Simpact NKS
Description

Accessories

Reference

Unit MRP [`]


680 730 800 970 225 4050

Auxiliary Contacts (Changeover)


Auxiliary Switch 1 C/O AX1CT1L n AL1CT1NR n NRHOMT1 n NDHOMT1 n NKSP13 n NEFR100T1N3P

 2 3 4 5 6

Alarm Switch 1 C/O

Rotary Handles
Standard direct black handle Standard extended rotary handle

Spreaders
Spreaders (Set of 3) 3P

Earth Fault Relay


3 Phase - 3 Wire

Voltage

Reference

Unit MRP [`]

Shunt Release
AC
100-130 V 240 V 415 V 440 V SHT110ACT1L SHT240ACT1L n SHT415ACT1L SHT440ACT1L SHT24DCT1L SHT48DCT1L SHT110DCT1L SHT220DCT1L 590 590

DC
24 V 48 V 110 V 220 V

Under Voltage Release


AC
110 V 220 V 415 V UVT110ACT1 UVT220/240ACT1 n UVT415ACT1 1100

Note: Please order necessary Shunt / Under-voltage with earth-fault relay

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

27

Simpact NKF
Ics = 100% Icu Conforms to IEC 60947-2 400-630A ratings in 3P & 4P versions Thermal magnetic trip unit Breaking Capacity Icu

Moulded Case Circuit Breakers for Distribution Network

Rated Current 45V, 50Hz

Three Pole Reference

Unit MRP Four Pole [`] Reference

Unit MRP [`]

Adjustable thermal setting 0.8 -  x In Adjustable magnetic setting (from 500A) 3.5 - 0 x In
250 - 320 35 kA 320 - 400 400 - 500 500 - 630 250 - 320 50 kA 320 - 400 400 - 500 500 - 630 NKF400C320AC3P NKF400C400AC3P n NKF800C500AC3P NKF800C630AC3P n NKF400K320AC3P NKF400K400AC3P n NKF800K500AC3P NKF800K630AC3P n 21300 23550 22400 25700 NKF400C320AC4P NKF400C400AC4P n NKF800C500AC4P NKF800C630AC4P n NKF400K320AC4P NKF400K400AC4P n NKF800K500AC4P NKF800K630AC4P n 26600 28900 29500 35000

 2 3

Fixed thermal magnetic setting Adjustable magnetic setting (from 500A) 3.5 - 0 x In
320 35 kA 400 500 630 320 50 kA 400 500 630 NKF400C320AC3PF NKF400C400AC3PF n NKF800C500AC3PF NKF800C630AC3PF n NKF400K320AC3PF NKF400K400AC3PF n NKF800K500AC3PF NKF800K630AC3PF n 21000 22500 23000 21200 24300 NKF400C320AC4PF NKF400C400AC4PF n NKF800C500AC4PF NKF800C630AC4PF n NKF400K320AC4PF NKF400K400AC4PF n NKF800K500AC4PF NKF800K630AC4PF n 23500 28700 26500 29900

4 5 6

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

28

Simpact NKF

Accessories

MCCB Accessories for Fixed and Adjustable types (3Pole/ 4Pole)


Description Reference

 2 3 4 5 6

Unit LP [`]

Frame Size - T3 NKF400C/K Internal Accessories


**Shunt Trip **Under-voltage release Auxiliary switch 1 c/o Auxiliary switch 2 c/o Alarm switch 1 c/o Alarm switch 2 c/o Alarm-auxiliary switch SHT . .T3L (LHS) n UVT . .T3 (LHS) n AX1CT3R (RHS) n AX2CT3R (RHS) n AL1CT3R (RHS) n AL2CT3R (RHS) n ALAXT3R (RHS) n NRHOMT3 n NDHOMT3 n 1160 1400 910 1060 800 1060 1230 850 1130

Rotary Handles
Standard Direct rotary handle Standard Extended rotary handle

Frame Size - T4 NKF800C/K Internal Accessories


**Shunt Trip **Under-voltage release Auxiliary switch 1 c/o Auxiliary switch 2 c/o Alarm switch 1 c/o Alarm switch 2 c/o Alarm-auxiliary switch SHT . .T4NL(LHS) n UVT . .T4NL (LHS) n AX1CT4NR (RHS) n AX2CT4NR (RHS) n AL1CT4NR (RHS) n AL2CT4NR (RHS) n ALAXT4NR (RHS) n NRHOMT4N n NDHOMT4N n 1160 1400 910 1060 800 1060 1230 850 1300

Rotary Handles
Standard Direct rotary handle Standard Extended rotary handle

Note: A maximum 2 nos internal accessories can be fitted in one breaker, one on each side. In case a particular internal accessory is selected, any second one, if required, shall be selected based on the location of the first accessory The location of SHT & UVT is fixed on LHS Auxiliary and Alarm Switch is site fittable & location is fixed on RHS ** The coil voltages of shunt trip coil and undervoltage releases are to be indicated in the blanks () of the product references e .g . to select 24V DC shunt reference shall be SHT24DCT3L & for 240V AC reference shall be SHT240ACT4L Similarly for under voltage references shall be UVT110ACT3 or UVT220/240ACT4 The available coil voltages are: For SHT - 110AC, 220/240AC, 415AC, 440AC (50Hz only) ; & 24DC, 48DC, 110DC and 220DC . For UVT - 110AC, 220/240AC, 415AC (50Hz only) For other technical specifications and delivery, kindly contact our nearest Sales Office.

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

29

LV Power Circuit Breakers and Switch-Disconnectors

 2
630

3 4 5 6

630

30

 2 3 4 5 6

3

 2 3 4 5 6

32

Masterpact MVS

Draw-out type Circuit breakers & Switch Disconnectors 800-3200A


Conforms to IS/ IEC 60947-2 & 3 Microprocessor based ET trip systems with thermal memory No derating up to 500 C Fully rated neutral with inbuilt protection Pre trip alarm & individual fault indicating LEDs ET6G provides Overload, Short-circuit, Instantaneous & Earth-fault protections ET2I provides Overload & Short-circuit protections Icu=Ics=Icw(1sec) =50kA @ 440V AC For complete technical data, please refer to our product catalogue 4P Draw-Out Manual Reference 4P Unit LP Unit LP Draw-Out Electrical [`] [`] Reference
148800 161100 170100 199000 235000 287400 369000 MVS08N4PEW6G MVS10N4PEW6G MVS12N4PEW6G MVS16N4PEW6G MVS20N4PEW6G MVS25N4PEW6G MVS32N4PEW6G 182000 194300 203300 232200 268200 320600 402200

 2 3 4 5 6
Rating In (A)
800 1000 1250 1600 2000 2500 3200

Draw-out type circuit breaker with microprocessor based ET6G trip system
MVS08N3PMW6G MVS10N3PMW6G MVS12N3PMW6G MVS16N3PMW6G MVS20N3PMW6G MVS25N3PMW6G MVS32N3PMW6G 116700 130000 138000 153700 193200 234200 298000 MVS08N3PEW6G MVS10N3PEW6G MVS12N3PEW6G MVS16N3PEW6G MVS20N3PEW6G MVS25N3PEW6G MVS32N3PEW6G 149900 163200 171200 186900 226400 267400 331200 MVS08N4PMW6G MVS10N4PMW6G MVS12N4PMW6G MVS16N4PMW6G MVS20N4PMW6G MVS25N4PMW6G MVS32N4PMW6G

3P Draw-Out Manual Reference

3P Unit LP Unit LP Draw-Out Electrical [`] [`] Reference

Draw-out type circuit breaker with microprocessor based ET2I trip system
800 1000 1250 1600 2000 2500 3200 MVS08N3PMW2I MVS10N3PMW2I MVS12N3PMW2I MVS16N3PMW2I MVS20N3PMW2I MVS25N3PMW2I MVS32N3PMW2I 104200 117500 125500 141200 180700 221700 285500 MVS08N3PEW2I MVS10N3PEW2I MVS12N3PEW2I MVS16N3PEW2I MVS20N3PEW2I MVS25N3PEW2I MVS32N3PEW2I 137400 150700 158700 174400 213900 254900 318700 MVS08N4PMW2I MVS10N4PMW2I MVS12N4PMW2I MVS16N4PMW2I MVS20N4PMW2I MVS25N4PMW2I MVS32N4PMW2I 136300 148600 157600 186500 222500 274900 356500 MVS08N4PEW2I MVS10N4PEW2I MVS12N4PEW2I MVS16N4PEW2I MVS20N4PEW2I MVS25N4PEW2I MVS32N4PEW2I 169500 181800 190800 219700 255700 308100 389700

Draw-out type switch disconnector without protection


800 1000 1250 1600 2000 2500 3200 MVS08NA3PMWD MVS10NA3PMWD MVS12NA3PMWD MVS16NA3PMWD MVS20NA3PMWD MVS25NA3PMWD MVS32NA3PMWD 100200 113500 121500 137200 176700 217700 281500 MVS08NA3PEWD MVS10NA3PEWD MVS12NA3PEWD MVS16NA3PEWD MVS20NA3PEWD MVS25NA3PEWD MVS32NA3PEWD 133400 146700 154700 170400 209900 250900 314700 MVS08NA4PMWD MVS10NA4PMWD MVS12NA4PMWD MVS16NA4PMWD MVS20NA4PMWD MVS25NA4PMWD MVS32NA4PMWD 132300 144600 153600 182500 218500 270900 352500 MVS08NA4PEWD MVS10NA4PEWD MVS12NA4PEWD MVS16NA4PEWD MVS20NA4PEWD MVS25NA4PEWD MVS32NA4PEWD 165500 177800 186800 215700 251700 304100 385700

Note: All draw-out type circuit breakers will be supplied with: (i) horizontal-horizontal terminations . (ii) 1 No . Electrical fault indication Contact (SDE) . (iii) 1 No . Auxiliary contact block (OF) with 4 C/O contacts . (iv) Safety shutters on Chassis & door sealing frame- Escutcheon (CDP) . All switch disconnectors are without protection All electrical operated breakers are supplied with motor mechanism (MCH), closing coil (XF) & shunt release (MX) . (Voltage ratings to be specified by customer & duly filled in ACB order form) External Neutral CT required for highly un-balanced TP-N system has to be ordered at extra price . Any other accessories are optional at extra price . Prices: The above are list prices & are inclusive of Excise duty . CST/ VAT/ Entry tax will be charged extra as applicable . For prices of fixed type circuit breakers and switch-disconnector, kindly contact our nearest sales office.

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

33

Masterpact MVS
Description

Accessories

Rated Operational Voltage

Reference

Unit MRP [`]

Gear Motor (MCH)


100/130 V AC 50/60 Hz 200/240 V 380/415 V 24/30 V DC 48/60 V 100/125 V 200/250 V 47893 47894 n 47896 47888 47889 47890 47891 33659 33660 33661 33662 n 33664 33668 33669 33670 33671 n 33673 n 33680 Rr (adjustable) 33681 33682 33683 R (non-adjustable) 33684 33685 64922 47914 5720 6480 4200 4100 25000

 2 3 4 5 6

Closing and Opening Release (XF or MX)


24/30 V DC AC 50/60 Hz DC 48/60 V DC 100/130 V AC/DC 200/250 V AC/DC 380/480 V AC

Under Voltage Release (MN)


24/30 V DC, 24 V AC AC 50/60 Hz DC 48/60 V DC, 48 V AC 100/130 V AC/DC 200/250 V AC/DC 380/480 V AC

MN Delay Unit
48/60 V AC/DC AC 50/60 Hz DC 100/130 V AC/DC 200/250 V AC/DC 380/480 V AC/DC 100/130 V AC/DC 200/250 V AC/DC

ON/OFF Indication Contacts (Additional OF contact)


1 additional block of 4 contacts 4100 2160

Door Interlock (VPECD)/ part


On right hand side of chassis

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

34

Enerpact
[In] Rated Current Fixed Manual Reference Unit LP [`]

Air Circuit Breakers - NH Series

Fixed Electrical Reference

Unit LP [`]

Draw out Manual Reference

Unit LP [`]

Draw out Electrical Reference

Unit LP [`]

3 Pole ACB with Thermal Magnetic Release

 2 3 4 5 6

(O/L and Short Circuit protection)


800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A NH800FM1T3P NH1000FM1T3P NH1250FM1T3P NH1600FM1T3P NH2000FM1T3P NH2500FM1T3P NH3200FM1T3P

61200 63700 89700 96800 111600 129400 194900

NH800FE1T3P NH1000FE1T3P NH1250FE1T3P NH1600FE1T3P NH2000FE1T3P NH2500FE1T3P NH3200FE1T3P

96600 99500 126400 138800 155100 172700 242200

NH800DM1T3P NH1000DM1T3P NH1250DM1T3P NH1600DM1T3P NH2000DM1T3P NH2500DM1T3P NH3200DM1T3P

94200 101300 125700 144200 174200 204500 272200

NH800DE1T3P NH1000DE1T3P NH1250DE1T3P NH1600DE1T3P NH2000DE1T3P NH2500DE1T3P NH3200DE1T3P

130200 134400 160900 178800 208600 234500 300100

4 Pole ACB with Thermal Magnetic Release


(O/L and short Circuit Protection)
800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A NH800FM1T4P NH1000FM1T4P NH1250FM1T4P NH1600FM1T4P NH2000FM1T4P NH2500FM1T4P NH3200FM1T4P 79400 83500 116100 127200 147000 170100 240900 NH800FE1T4P NH1000FE1T4P NH1250FE1T4P NH1600FE1T4P NH2000FE1T4P NH2500FE1T4P NH3200FE1T4P 120200 124200 157500 173300 191800 213700 289300 NH800DM1T4P NH1000DM1T4P NH1250DM1T4P NH1600DM1T4P NH2000DM1T4P NH2500DM1T4P NH3200DM1T4P 122500 131400 163800 185700 224500 266300 326200 NH800DE1T4P NH1000DE1T4P NH1250DE1T4P NH1600DE1T4P NH2000DE1T4P NH2500DE1T4P NH3200DE1T4P 167600 175500 210300 231000 272200 301900 362000

Note: 1 . All electrical operated breakers are provided with one closing coil, motor mechanism & one shunt coil as a standard for customer usage (Voltage ratings to be specified by the customer & duly filled in the ACB order form) 2 . Thermal magnetic ACBs will be fitted with protective releases for O/L and S/C protection. As a standard, thermal magnetic ACBs will be provided with shunt trip coil (Voltage rating as specified by the customer). 3 . In case EF protection required for Thermal-magnetic ACB, for 3Phase 3 wire system, price of EFR -Z128 to be added to the price of ACB . For 3Phase 4 Wire system price of EFR-Z129 & NCT (Neutral CT) depending on the rating of ACB to be added to the price of ACB . 4. All breakers are fitted with 4NO+4NC auxiliary contact block. 5 . 16 way sliding contacts & Safety Shutter assembly are supplied as standard in drawout breakers . 6 . In Draw-out ACBs Type ' F' Rear termination is standard for ratings upto 1250A and Type ' V ' for 1600 A and above . Both Type ' H ' and ' V ' termination is available as an option for breakers upto 1250A with additional price as indicated in the next page . For Mixed connection (combination of H & V) up to 1250A and Type ' H ' for 1600A and above, please contact our Sales Office. 7 . All Fixed ACBs will be supplied with Type ' H ' termination as standard .

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

35

Enerpact
Description

Air Circuit Breakers - Accessories

Reference

Unit MRP [`]

Air Circuit Breakers Accessories


Micro-switch for S/C trip indication (for TM ACB) (To be specified during ordering) Mechanical counter Earth Fault Relay 3Ph 3wire (1) Earth Fault Relay 3Ph 4wire (1) Chassis position lock Door interlock kit (Fixed ACB) Door interlock kit (Draw-out ACB) Transparent cover for push button locking Z125 Z127 Z602 Z128 Z129 Z236 Z245F Z245D ZTCPB 1800 1900 1600 2000 1950 2100 2400 Special sliding contact for electrical position indication

 2 3 4 5 6

Air Circuit Breakers Accessories


Spares (Common for all ratings)
Floating gasket for escutcheon Racking handle Terminal block-16 way (Aux contact) Terminal block - 8 way (for Manual ACB) Escutcheon cover (2) Aux . contact block 4NO+4NC Fixed+Moving sliding contact-2Nos . Z217 Z204 Z106A Z106B Z202 Z601 Z214 800 750 800 600 1100 1320 440

Optionals
Reduction in LP for - 3 Pole Isolators i.e. without protection Replace 'T' by 'B' in type reference of Thermal magnetic ACB NH800-1000 NH1250 NH1600 - 2000 NH2500 - 3200 3500 7000 8000 11000 Price Reduction in LP for - 4 Pole Isolators i.e. without protection Replace 'T' by 'B' in type reference of Thermal magnetic ACB NH800-1000 NH1250 NH1600 - 2000 NH2500 - 3200 Extra price for optional rear connections for NH800/250A Draw-out ACB Type ' H ' or ' V ' connection (1) Add Suffix B for Base mounting & D for Door mounting. (2) To be ordered along with ACB order form giving detail specifications 4000 4500 9000 10000 14000 Price

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

36

Enerpact
Description Reference

Air Circuit Breakers - Spares

Unit MRP [`]


2050 2550 4850 6550 4000 5200 4000 5200 6400 8700

Description

Reference

Unit MRP [`]


2450 3050 6650 7850 7750 10300 7750 10300 10400 15150

Frame Size: NH 800


Shutter Assembly - 3 Pole Z237 Z240 Z101A3 Z101A4 Z102A3 Z102A4 Z103A3 Z103A4 Z201AA3 Z201AA4 ZCT01 ZCT02 ZCT03 ZNCT11 Z211B3 Z211B4 1450 900 1200 2900

Frame Size: NH 600 - 2000


Shutter Assembly - 3 Pole Shutter Assembly - 4 Pole Arc Chute - set of 3 Arc Chute - set of 4 Fixed Arcing contacts - 3P Fixed Arcing contacts - 4P Moving Arcing contacts - 3P Moving Arcing contacts - 4P Floating Isolating contacts (1) - set of 3 Floating Isolating contacts (1) - set of 4 CTs for Thermal overload relay - 3Nos. 1600A 2000A NCT for Thermal-magnetic - No. 1600 - 2000A Phase barriers - 3P Phase barriers - 4P ZNCT13 Z211C3 Z211C4 1950 900 1200 ZCT21 ZCT22 3150 Z238 Z241 Z101B3 Z101B4 Z102B3 Z102B4 Z103B3 Z103B4 Z201B3 Z201B4

 2 3 4 5 6

Shutter Assembly - 4 Pole Arc Chute - set of 3 Arc Chute - set of 4 Fixed Arcing contacts - 3P Fixed Arcing contacts - 4P Moving Arcing contacts - 3P Moving Arcing contacts - 4P Floating Isolating contacts (1) - set of 3 Floating Isolating contacts (1) - set of 4 CTs for Thermal overload relay - 3Nos. 400A 630A 800A 400-630-800A Phase barriers - 3P Phase barriers - 4P

NCT for Thermal-magnetic Release - No.

Frame Size: NH 000 - 250


Shutter Assembly - 3 Pole Shutter Assembly - 4 Pole Arc Chute - set of 3 Arc Chute - set of 4 Fixed Arcing contacts - 3P Fixed Arcing contacts - 4P Moving Arcing contacts - 3P Moving Arcing contacts - 4P Floating Isolating contacts (1) - set of 3 Floating Isolating contacts 800A 1000A 1250A NCT for Thermal-magnetic - No. 800-1000-1250A Phase barriers - 3P Phase barriers - 4P ZNCT12 Z211B3 Z211B4 1450 900 1200
(1)

Frame Size: NH 2500 - 3200


Z237 Z240 Z101A3 Z101A4 Z102A3 Z102A4 Z103A3 Z103A4 Z201A3 Z201A4 ZCT11 ZCT12 ZCT13 3050 2050 2550 4850 6550 4000 5200 4000 5200 6400 8700 Shutter Assembly - 3 Pole Shutter Assembly - 4 Pole Arc Chute - set of 3 Arc Chute - set of 4 Fixed Arcing contacts - 3P Fixed Arcing contacts - 4P Moving Arcing contacts - 3P Moving Arcing contacts - 4P Floating Isolating contacts (1) - set of 3 Floating Isolating contacts 2500A 3200A NCT for Thermal-magnetic - No. 2500 - 3200A Phase barriers - 3P Phase barriers - 4P ZNCT14 Z211D3 Z211D4 2300 900 1200
(1)

Z239 Z242 Z101C3 Z101C4 Z102C3 Z102C4 Z103C3 Z103C4 Z201C3 Z201C4 ZCT31 ZCT32 - set of 4

3400 4500 11250 15750 11500 15000 11500 15000 16600 21550

- set of 4

CTs for Thermal overload relay - 3Nos.

CTs for Thermal overload relay - 3Nos. 3400

1 . Floating isolating contacts are to be used only with Draw-out ACBs .

Note: For all other spares and after-sales requirement, please contact our Customer Service Department or Sales Office

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

37

Enerpact
Description
24/30V 48/60V 100/130V 200/250V 380/480V 48/60V AC,DC 100/130V AC,DC 200/250V AC,DC 380/480V AC,DC

Air Circuit Breakers - Spares


Unit MRP [`]

Reference
ZMN24/30 ZMN48/60V-ACDC ZMN100/130 ZMN200/250 n ZMN380/480 n ZMNR48/60V-ACDC ZMNR110/130V-ACDC ZMNR200/250V-ACDC ZMNR380/480V-ACDC ZMX112VDC ZMX124/30 ZMX1-48/60V-ACDC ZMX1100/130 ZMX1200/250 n ZMX1-277V-ACDC ZMX1380/480 ZMX212VDC ZMX2-24/30V-ACDC ZMX2-48/60V-ACDC ZMX2-100/130V-ACDC ZMX2-200/250V-ACDC ZMX2-277V-ACDC ZMX2-380/480V-ACDC ZXF12V-DC ZXF24/30 ZXF48/60V-ACDC ZXF100/130V-ACDC ZXF200/250V-ACDC ZXF277V-ACDC ZXF380/480V-ACDC

Description
24/30V DC 48/60V DC

Reference
ZMCH24/30DC ZMCH48/60DC ZMCH100/125DC ZMCH200/250DC ZMCH100/130AC ZMCH200/240AC n ZMCH277AC ZMCH380/415AC ZMCH400/440AC ZMCH480AC Z244CA n Z244CB Z244CC Z244C-B Z244CCZ244CAB Z244CCB Z244CCD Z244C-D Z244CAZ244PCA Z244PCB Z244PCC Z244PC-B Z244PCCZ244PCAB Z244PCCB Z244PCCD Z244PC-D Z244PCA-

Unit MRP [`]

Instantaneous U/V Release


4200

AC/DC Electrical Charging motor

100/125V DC 200/250V DC 100/130V AC 200/240V AC 277V AC 380/415V AC 400/440V AC 480V AC


26250

Time delay unit for U/V Release


6480

2 3
1900

Shunt trip coil


12V DC 24/30V ACDC 48/60V ACDC 100/130V ACDC 200/250V ACDC 277V ACDC 380/480V ACDC

Castell lock with key


Letter A Letter B Letter C 4100 Letter -B Letter CLetter AB Letter CB Letter CD Letter -D Letter A4180 Letter A Letter B Letter C Letter -B Letter CLetter AB Letter CB Letter CD 4100 Letter -D Letter A-

Additional Shunt trip coil


12V DC 24/30V ACDC 48/60V ACDC 100/130V ACDC 200/250V ACDC 277V ACDC 380/480V ACDC

4 5
2300

Padlock for locking in OFF position

Closing coil
12VDC 24/30V ACDC 48/60V ACDC 100/130V ACDC 200/250V ACDC 277V ACDC 380/480V ACDC

Note: ZMX1 is mandatory for thermal magnetic ACB . ZMX2 is optional .

RS relay for time delayed S/C in Thermal - Magnetic ACB (40ms fixed) AC input
240V AC base mtg . 240V AC door mtg . Z123B Z123D 2400

RS relay for time delayed S/C in Thermal - Magnetic ACB (40~460ms adjustable) AC input
110V AC base mtg . 240V AC base mtg . 415V AC base mtg . 24V DC base mtg . 48V DC base mtg . 110V DC base mtg . 220V DC base mtg . 110V AC door mtg . 240V AC door mtg . 415V AC door mtg . 24V DC door mtg . 48V DC door mtg . 110V DC door mtg . 220V DC door mtg . ZRSB-110VAC ZRSB-240VAC ZRSB-415VAC ZRSB-24VDC ZRSB-48VDC ZRSB-110VDC ZRSB-220VDC ZRSD-110VAC ZRSD-240VAC ZRSD-415VAC ZRSD-24VDC ZRSD-48VDC ZRSD-110VDC ZRSD-220VDC 3400

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

38

Interpact

Switch Disconnectors
For Low Voltage Circuit Control and Isolation - Incomers for Distribution Boards Conforms to IEC 60947-3/IS 13947 - 3 Rated operational voltages 500V/690V Rated operational current @ AC 23A No deration upto 60 C Positive contact indication Common accessories with Compact NS/single auxillary contact Making capacity enhanced with Compact NS upstream Rated Operational Current Reference Unit MRP [`]
2700 3300 3900 4200 4800 7600 8000 12500 13000 16200 3000 3600 4200 4700 5200 8400 8800 14100 14700 17600 18000 19600 21600 22200 36700 39200 41900 20600 22500 25500 26300 40000 43400 47300


Pole Description

2 3 4

Interpact Range of Switch Disconnectors


40 A AC-23A 63 A AC-23A 100 A AC-23A 125 A AC-23A 3-Pole 160 A AC-23A 200 A AC-23A 250 A AC-23A 320 A AC-23A 400 A AC-23A 630 A AC-23A 40 A AC-23A 63 A AC-23A 100 A AC-23A 125 A AC-23A 4-Pole 160 A AC-23A 200 A AC-23A 250 A AC-23A 320 A AC-23A 400 A AC-23A 630 A AC-23A 28900 28902 28908 28910 28912 31102 31106 31108 31110 31114 28901 28903 28909 28911 28913 31103 31107 31109 31111 31115 31140 31144 31142 31146 31148 31150 31154 31141 31145 31143 31147 31149 31151 31155

5
lnterpact Changeover Systems (complete assembly)

100 A AC-23A 160 A AC-23A

200 A AC-23A 3-Pole 250 A AC-23A 320 A AC-23A 400 A AC-23A 630 A AC-23A 100 A AC-23A 160 A AC-23A 200 A AC-23A 4-Pole 250 A AC-23A 320 A AC-23A 400 A AC-23A 630 A AC-23A

Description

Reference
29450SEI n 31050 31052 28941 n 28959 29329 32570

Unit MRP [`]


680 2400 2700 1200 420 375 700

Accessories

Auxiliary contact - 1 OC or 1 SD or 1 SDE or 1 SDV Optional front extended rotary handle INS 250 - black handle (Switch Disconnector) Optional front extended rotary handle INS 320 . .630 - black handle (Switch Disconnector) Optional front extended rotary handle INS 40 . .160 - black handle (Switch Disconnector) 6 phase separators - INS100 . .160 6 phase separators - INS250 6 phase separators - INS400 . .630

n NORMAL STOCK ITEMS

W.E.F. January 20, 20

39

Fupact

Switch Disconnector Fuse units

Complete Range from 32 to 630A in TP, TP+N & FP version suitable for DIN/BS fuses . 4 breaks and 8 arcing points IP20 Fuse Protection Cover is standard Higher Mechanical and Electrical life .

Without Enclosure
Rated Operational Current
32 A 63 A 80 A 100 A

Poles Description
3P + N 3P + N 3P + N 3P 3P + N 4P 3P

DIN Type Reference


NX032TPNDI n NX063TPNDI n NX080TPNDI n NX100TPXDI NX100TPNDI n NX100FPXDI NX125TPXDI n NX125TPNDI n NX125FPXDI NX160TPXDI NX160TPNDI n NX160FPXDI NX200TPXDI NX200TPNDI n NX200FPXDI NX250TPXDI NX250TPNDI n NX250FPXDI NX315TPXDI NX315TPNDI n NX315FPXDI NX400TPXDI NX400TPNDI n NX400FPXDI NX630TPXDI NX630TPNDI n NX630FPXDI

Unit MRP BS Type [`] Reference


1380 1960 3990 3570 4040 4080 4000 5040 5780 4940 5780 6350 5150 6530 7280 6930 7880 9690 8200 9650 10760 10120 11580 12710 16280 18090 20480 NX032TPNBS n NX063TPNBS n NX080TPNBS NX100TPXBS NX100TPNBS n NX100FPXBS NX125TPXBS NX125TPNBS n NX125FPXBS NX160TPXBS NX160TPNBS n NX160FPXBS NX200TPXBS NX200TPNBS n NX200FPXBS NX250TPXBS NX250TPNBS n NX250FPXBS NX315TPXBS NX315TPNBS n NX315FPXBS NX400TPXBS NX400TPNBS n NX400FPXBS NX630TPXBS NX630TPNBS n NX630FPXBS

Unit MRP [`]


1320 1840 3780 3260 3660 3990 3930 4780 5460 4730 5250 6000 4940 6090 7190 6770 7560 8510 7560 9530 10030 9990 10970 12390 15750 16800 19950

 2 3 4 5 6

125 A

3P + N 4P 3P

160 A

3P + N 4P 3P

200 A

3P + N 4P 3P

250 A

3P + N 4P 3P

315 A

3P + N 4P 3P

400 A

3P + N 4P 3P

630 A

3P + N 4P

With Enclosure Ref. DIN Type


Rated Operational Current
32 A 63 A 80 A 100 A 125 A 160 A 200 A 250 A 315 A 400 A 630 A

Accessories/Spares
Reference
NX032TPNDIE NX063TPNDIE n NX080TPNDIE NX100TPNDIE NX125TPNDIE NX160TPNDIE NX200TPNDIE NX250TPNDIE NX315TPNDIE NX400TPNDIE NX630TPNDIE

Poles Description
3P + N 3P + N 3P + N 3P + N 3P + N 3P + N 3P + N 3P + N 3P + N 3P + N 3P + N

Unit MRP [`]


2940 3610 5760 5900 6830 7580 8470 10710 13130 14890 23050

Description

Reference
NXAA11 n NXHD1 NXRS1 NXBA11 n NXHB21 NXHD21 NXR2 n NXRS2 NXBA11 n NXHB22 NXHD22 NXR2 n NXRS2A NXBA11 n NXR3 NXRS3 NXBA11 n NXR4 NXRS4

Unit MRP [`]


310 120 240 140 380 110 120 540 140 380 110 145 540 170 380 540 170 380 590 170

NX032/NX063/NX080
Auxiliary contact for Fupact Fuse holder for DIN NX032 . . .NX080 HOM shaft for NX/32/63/80 Handle operating mechanism (HOM) NX032 . . .NX080 NXR1 n

NX00/NX25/NX60
Auxiliary contact for Fupact Fuse holder DIN for BS type NX100 . . .NX160 Fuse holder DIN for NX100 . . .NX160 Handle operating mechanism NX100 . . .NX160 Shaft for HOM for NX100 . . .NX160

NX200
Auxiliary contact for Fupact Fuse holder for BS type NX200 Fuse holder for DIN NX200 Handle operating mechanism NX200 Shaft for HOM for NX200

Note: For Fuses, please contact our nearest Sales Office.

NX250/35/400
Auxiliary contact for Fupact Handle operating mechanism for NX250 . . .NX400 Shaft for HOM for NX250NX400

NX250/35/400
Auxiliary contact for Fupact Handle operating mechanism for NX630 Shaft for HOM for NX630 n NORMAL STOCK ITEMS

W.E.F. January 20, 20

40

Make the most of your energy

Schneider Electric India Pvt. Ltd.


Corporate Office: 9th Floor, DLF Building No. 10, Tower C, DLF Cyber City, Phase II, Gurgaon 122002 Haryana Tel.: ++91 124 3940400 Fax: ++91 124 4222036

Chandigarh

Schneider Electric India (P) Ltd. SCO - 13-14-15.4th Floor, Sector-34-A Chandigarh - 160022 Tel.: 0172-5076781/82/83/84 Fax: 0172-2669043

Mumbai

Schneider Electric India (P) Ltd. Unit No. 1141,1142 Building No. 11, 4th Floor Solitaire Corporate Park Andheri Kurla Road, Chakala Andheri (E), Murnbal - 400059 Tel.: 022-39404000 Fax: 022-30738800

Vadodara

Schneider Electric India (P) Ltd. 305, Concord, 4th floor, RC Dutt Road, Alkapuri, Vadodara Tel.: 0265-2359117 Fax: 0265-2353406

Coimbatore

Schneider Electric India (P) Ltd. No. 104, 3rd Floor, Classic Tower, Trichy Road, Coimbatore - 641 013 Tel.: 0422-4392729/4392927 Fax: 0422-4392972

Jaipur

Schneider Electric India (P) Ltd. Jaipur Business Centre 309, 3rd Floor Sangam Tower 190, Church Road, Jaipur - 302001 Tel.: 0141-4002075 Fax: 0141-5108632

Pune

Schneider Electric India (P) Ltd. 2nd Floor, R.B. Business Centre Above Dass Electronics Sanghavi Nagar, Aundh, Pune - 411007 Tel.: 020-39404000 Fax: 020-39852600

Bangalore

Schneider Electric India (P) Ltd. Esquire Centre Ground Floor B-Block NO.9, M.G. Road Bangalore - 560001 Tel.: 080-39404000 Fax: 080-25582504

Nagpur

Schneider Electric India (P) Ltd. Fortune Business Centre 6, Vasant Vihar, W.H.C Road Shankar Nagar, Nagpur - 440010 Tel.: 0712-2558581/ 2542218 Fax: 0712-2550070

Jamshedpur

Schneider Electric India (P) Ltd. The Business Centre Moti Bhavan Road No. 1 Contractors Area, Bistupur Jamshedpur - 831001 Tel.: 0657-2226560 Fax: 0657-2222757

Ahmedabad

Schneider Electric India (P) Ltd. 41/B & 42/A, Space House Opp. Sri Krishna Centre, Mithakall Six Roads, Navrangpura, Ahmedabad - 380009 Tel.: 079 39404000 Fax: 079 26440368

Chennai

Schneider Electric India (P) Ltd. III Iloor, DBS Westminister, No 108/5, Dr.R.K.Salai, Mylapore Chennai - 600004 Tel.: 044 39143200 Fax.: 044 39143214

Kolkata

Schneider Electric India (P) Ltd. Sugam Business Park 4th & 5th Floor, Plot-J6 Block - GP, Sector-5 Salt Lake City Kolkata - 700091 Tel.: 033 39404000 Fax: 033 30248686

Lucknow

Schneider Electric India (P) Ltd. 27/2A, First Floor, Asha Bhavan, Gokhle Marg, Lucknow (UP) Tel.: 0522-4006012 Fax: 0522-4006015

Secunderabad

Schneider Eleclric India (P) Ltd. D. NO. 1-8-271, # 102, Ashoka Bhoopal Chambers, S.P. Road, Secunderabad - 500003 Tel.: 040-39404000 Fax: 040 39131313

Cochin

Schneider Electric India (P) Ltd. 41/408, D1, BeeJay Towers, Above Qatar Airways, Rajaji Road Cochin - 682035 Tel.: 0484-3048401/2/3 Fax: 0484-3048405

Vishakhapatnam

Schneider Electric India (P) Ltd. Ratnam Executive Centre D. No. 10-1-43, 1st Floor Siripuram Fort, CBM Compound Vishakapatnam - 503003 Tel.: 0891 - 6662221 Fax: 0891 -2508990

Ludhiana

Office No. 3, Fifth Floor, Novelty Plaza, Opp Park Plaza, Bhai Wala Chowk, Ludhiana-140001, Punjab Tel.: 0161-4656672-75 Fax: 0161-4656671

For more information, visit our website at: www.schneider-electric.co.in