Professional Documents
Culture Documents
VM-21G
Specification
Model Terminal Screw Size Number of Mountable Signal Conditioners Operating Temperature Relative Humidity Installation External Dimensions Casing Material (color) Weight CE Marking VM-21G Signal Conditioner Socket
M3 1 0 to 50 (32 to 122 F REF.)
10 to 90%RH (no condensation) DIN rail, wall-mounted W29.5 H72 D30 (mm) Polyphenylene oxide (black) Approx. 50g (0.11lb) Only as for 24VDC power supply specifications
Terminal Arrangement
VM-21R VM-21K No. 1 2 3 4 5 6 7 8 9 10 11 COM BUF COM BUF COM BUF 24V IN COM IN COM IN COM IN COM WAVE COM BUF COM BUF 24V IN COM VM-21U VM-21B VM-21A VM-21T FK input 24V IN COM PULSE COM BUF IN COM PULSE COM BUF OUT GND COM L N TP TP MS input VM-21P IN A IN B IN C VM-21D IN F IN D/E IN C IN A IN B / TP TP COM B B COM COM(-) Thermocouple IN VM-21F RTD A mV signal IN VM-21E IN(+)
SERIES
Contact to
Published in Apr.2009
2005-2009
VM-21EProcess
Power supply
1 2
VM-21E
Measuring range
1 2 1 to 5VDC 4 to 20mADC 1 2
Output
1 to 5VDC 4 to 20mADC
Conditioner socket
0 1 Without Include
24VDC 100-240VAC/DC
Block Diagram
VM-21EProcess
Z IN(+) R IN(-) 3 R is an attenuator when cuurent input. Low drift input processing circuit Isolation circuit
Output circuit
Specification
Model Input Range Input Resistance Output (isolated) I/O Conversion Accuracy Response Time Reception Resisntace Supply Permissible Voltage Power Consumption VM-21E Process 1 to 5VDC, 4 to 20mADC 1 to 5VDC : 1M, 4 to 20mADC : 250 1 to 5VDC load resistance 2k or more 4 to 20mADC , permissible load resistance 600 or less 1 0.5 of F.S. at 25 120ms 63 response (input change 10 to 90%) Attaching externally (Installation for current input) 24VDC10 or 85 to 264VAC/DC 50/60Hz 24VDC 2.4W, 110VDC 2.6W, 100-240VAC 7.1VA 100M minimum at 500VDC between input output power GND mutually. 2,000VAC for one minute between input output power GND mutually. With VM-21H : 1,000VAC between output GND. 0 to 50 (32 to 122 F REF) 10 to 90%RH no condensation Modified polyphenylene oxide black Approx. 116g 0.26lb Only as for 24VDC power supply specifications.
Acceleration Transducer
Insulation Resistance Withstanding Voltage Operating Temperature Relative Humidity Casing Material (color) Wight CE Marking
Fan/Blower
1 The output mode is not changeable on the field. Specifications, outline drawings and other written information can be changed without notice.
PLC
Compressor
Typical Application
10
Block Diagram
VM-21P 3-Wire LVDT (LS Series)
VM-21K
VM-21K
Power supply 1 2 24VDC 100 to 240VAC/DC Measuring range 21 0 to 100 m pk-pk 22 0 to 125 m pk-pk 23 0 to 200 m pk-pk
B 1
TP(+) 6
Output 1 to 5VDC 4 to 20mADC Conditioner socket 0 Without 1 Include
Check output TP(-) IN(A) 5 1 2 3 Oscillator Input abnormal detector Isolation circuit Output circuit Demodulator ZERO/SPAN adjusting circuit 7 9 OUT Output COM Z S
1 2
VM-21U
VM-21U
Power supply 1 2 24VDC 100 to 240VAC/DC Measuring range1 21 0 to 100 m pk-pk 22 0 to 200 m pk-pk 61 0 to 25mm/s pk 62 0 to 50mm/s pk
Input
IN(B) IN(C)
1 2
*1 In the measuring ranges for displacement vibration measurement (e.g., 0 to 100 m pk-pk), it has possibility that the monitor also picks up low-frequency vibrations from the surroundings, such as transmitted by the piping and foundation, so that the output may be greater than the vibrations produced by the monitored object itself.
VM-21B
VM-21B
Power supply 1 2 24VDC 100 to 240VAC/DC 20 21 22 23
Measuring range1 Input transducer Frequency response Output Conditioner socket 1 1 to 5VDC 0 Without Velocity Acceleration CA Series 1 10Hz to 5kHz ( 3dB) A (100mV/9.8m/s2 pk) 0 to 15mm/s pk 61 0 to 2g pk 2 4 to 20mADC 1 Include (Velocity output) 0 to 25mm/s pk 62 0 to 5g pk 2 1kHz to 10kHz ( 3dB) 0 to 50mm/s pk 63 0 to 10g pk (Acceleration output) 0 to 100mm/s pk 64 0 to 20g pk 3 20Hz to 5kHz ( 3dB) 71 0 to 20m/s2 pk (Velocity output) 0 to 50m/s2 pk *1 In the measuring ranges for velocity vibration measurement (e.g., 0 to 15mm/s pk), it has 72 2 pk possibility that the monitor also picks up low-frequency vibrations from the surroundings, such as 73 0 to 100m/s transmitted by the piping and foundation, so that the output may be greater than the vibrations 74 0 to 200m/s2 pk produced by the monitored object itself.
VM-21D
VM-21A
Vibration
VM-21A
1
Frequency response 1 10Hz to 2kHz ( 3dB) 2 5Hz to 1kHz ( 3dB) 3 10Hz to 1kHz ( 3dB) 4 10Hz to 5kHz ( 3dB) 5 1kHz to 10kHz ( 3dB) Wave Output 1 Velocity Acceleration 2 Displacement 3
3
IN(B)/TP(-) 5 IN(F) 1
Measuring range 0 to 2g pk 0 to 100 m pk 61 0 to 200 m pk 62 0 to 5g pk 0 to 25mm/s pk 63 0 to 10g pk 0 to 50mm/s pk 64 0 to 20g pk 0 to 100mm/s pk 71 0 to 20m/s2 pk 72 0 to 50m/s2 pk 73 0 to 100m/s2 pk 74 0 to 200m/s2 pk
Input
Demodulator
Specification
Model Input Transducer Input Sensitivity Input Resistance Measuring Range Output (isolated) I/O Conversion Response Speed Frequency Response Burn-down Function Buffered Output Wave Output Power Supply Output Supply Permissible Voltage Power Consumption Insulation Resistance Withstanding Voltage Operating Temperature Relative Humidity Casing Material Weight CE Marking
24VDC (30mA with short-circuit protection)
*1 Input transducer is A : Can not select 11 and 12 of measuring range. Input transducer is V : Can not select 61 and 64, 71 and 74 of measuring range. *2 When the input transducer V, frequency response code 0 (standard), 3 or 4 is highly recommended. When the frequency response code 1 or 2 is selected, an excessive vibration output may result at low-frequency. *3 Input transducer is A : Can not select 3 of waveform output. Input transducer is V : Can not select 2 of waveform output.
Oscillator
Isolation circuit
Output circuit
9 10
11 8
VM-21A Vibration
CA-302, CA-721, CA-722 or CV-86, CV-88 3.94mV/mm/s pk 100mV/9.8m/s2 pk (100mV/g pk REF.)
50k See Model Code above 1 to 5VDC (output resistance : 250) or 4 to 20mADC (permissible load resistance : 600 or less) 1 of F.S. at 25 , 2 of F.S. at 0 to 50 response 500ms, 63 5Hz to 4kHz ( 3dB) 10Hz to 2kHz ( 3dB) or 20Hz to 2kHz ( 3dB)
10Hz to 5kHz ( 3dB) or 5Hz to 1kHz ( 3dB), 10Hz to 2kHz 3dB 5Hz to 10kHz ( 3dB), 10Hz to 1kHz 3dB 20Hz to 5kHz 3dB Acc. output 1kHz to 10kHz ( 3dB) 10Hz to 5kHz 3dB , 1kHz to 10kHz 3dB Detects transducer failure and causes the 4 to 20mADC (1 to 5VDC) output to go to less than 0.8mADC (0.2VDC). Input signal is outputted via a buffer amplifier. Signal level 2 to 22VDC Output impedance 100 5Vpk-pk at F.S. (Sine wave) 24VDC (4mA constant current) 24VDC 100M 10 or 85 to 264VAC/DC (50/60Hz) GND mutually. 24VDC 3.5W, 110VDC 3.5W, 100-240VAC 10VA minimum at 500VDC between input output power 2,000VAC for one minute between input output power GND mutually. (with VM-21H : 1,000VAC between output GND.) 0 to 50 (32 to 122 F REF.) 10 to 90 RH (no condensation) Modified polyphenylene oxide (black) Approx. 110g (0.24lb) Only as for 24VDC power supply specifications.
Vel. output
Input signal is outputted via a buffer amplifier. Signal level 2 to 22VDC Output impedance 100
Specifications, outline drawings and other written information can be changed without notice.
VM-21TThrust
VM-21RRevolution
VM-21T
Power supply 1 2 24VDC 100-240VAC/DC
Intrinsically safe
0 1 Non-intrinsically safe spec. Intrinsically safe spec. 0 1
Polarity3
Direct Reverse 1 2 Output 1 to 5VDC 4 to 20mADC Conditioner socket 0 1 Without Include 1 2
VM-21R
Power supply
24VDC 100-240VAC/DC 21 22 23
Input transducer
D J
Output
1 2 1 to 5VDC 4 to 20mADC
Measuring range12
21 22 0 to 2mm 0 to 4mm
Input transducer
B FK-202F VK-202A m 787mV/100 FK-452F VK-452A m 394mV/100
Measuring range
0 to 5,000rpm 0 to 10,000rpm 0 to 15,000rpm 0 to 20,000rpm 0 to 50,000rpm 0 to 100,000rpm
Conditioner socket
0 1 Without Include
Note) 3 Polarity Display and recorder output Polarity Direct Reverse In the direction toward the sensor Increase Decrease In the direction away from the sensor Decrease Increase 10Hz
24 25 26
Note) 1 VK transducer can not detect break in the sensor system, so RD tacho driver or FK driver wichi can detect the wire break shall recommended.
B A C A B
Note)1 In the case of Intrinsic safety specification, measuring range decrease as below, 0 to 1.8mm (Input transducer : B), 0 to 3.6mm (Input transducer : C). 2 Input transducer is B : Don't select 22 of measuring range. Input transducer is C : Don't select 21 of measuring range.
Note) Normal operating range is, Max. rotor speed(rpm)No. of P/R 60 10kHz
Brock Diagram
VM-21TThrust
WARNING This signal conditioner is designed for monitoring but not for controlling the rotor speed. Use the conditioner output only for date recording. Do not use this signal for zero-speed monitoring.
Note) To detect projection (gear), provide surface A of projection with a concentric curve. Do not make it flat.
A=________ mm B=________ mm C=________ mm D=________ mm
6 7 2.5 16
BUF Buffered output COM IN Input COM Sensor power supply output -24V
6 5 2 3 1 Input abnormal detector Input processing circuit Low pass filter Polarity change circuit
Block Diagram
Z S
VM-21RRevolution
PULSE 4 Pulse output COM Buffered output
Isolation circuit
Trigger level 5 6 2 3 1 Constant voltage circuit Power supply circuit Input processing circuit Input abnormal detector Recitification circuit (Manual) Recitification circuit (Auto) ZERO/SPAN adjusting circuit (microcomputer) Isolation circuit Output circuit 7 9 10 11 8 OUT Output COM L+ NGND Supply
BUF
Output circuit 7 9 OUT
Output
COM
Handy terminal
Specification
Model Input Transducer Input Sensitivity Input Resistance Measuring Range Output (isolated) I/O Conversion Accuracy Response Speed Burn-down Function Buffered Output Power Supply Output Zero-shift Supply Permissible Voltage Power Consumption Insulation Resistance Withstanding Voltage Operating Temperature Relative Humidity Casing Material (color) Weight CE Marking VM-21T Thrust
FK-202F, VK-202A, FK-452F, VK-452A m (FK-202F, VK-202A), 394mV/100m (FK-452F, VK-452A) 787mV/100 50k See Model Code No. above 1 to 5VDC output resistance 250 4 to 20mADC or permissible load resistance 600 or less 1 of F.S. at 25, 2 of F.S. at 0 to 50 50ms 63 response (input change 10 to 90%) Detects transducer failure and causes the 4 to 20mADC (1 to 5VDC) output to go to less than 0.8mADC (0.2VDC). Input signal is outputted via a buffer amplifier. Signal level 2 to 22VDC Output impedance 100 24VDC 30mA with short-circuit protection 20% (5%) to 0 to +20% (5%) of F.S. 24VDC10 or 85 to 264VAC/DC 50/60Hz 24VDC 6.0W, 110VDC 6.0W, 100-240VAC 20VA 100M minimum at 500VDC between input output power GND mutually.
Specification
Model Input Transducer Input Resistance Input Frequency Minimum Input Voltage Hysteresis Output (isolated) Measuring Range I/O Conversion Accuracy Buffered Output Pulse Output Trigger Lovel Setting Burn-down Function Supply Permissible Voltage Power Consumption Insulation Resistance Withstanding Voltage Operating Tmeprature Relative Humidity Casing Material (color) Weight CE Marking
2
VM-21R Revolution
RD series, FK series, VK series, MS series 50k (Model Code No. of input transducer "D"), 5k (Model Code No. of input transducer "J" Min. Input frequency : 0.01Hz, Max. Input frequency : 10kHz, Min Pulse width : 50sVp-p 2Vp-p 1Vp-p, 5Vp-p 1 to 5VDC output resistance 250 4 to 20mADC or permissible load resistance 600 or less See Model Code No. above 1 of F.S. at 25, 2 of F.S. at 0 to 50 Model Code No. of input transducer "D" : Approx. 2 to 22VDC, Model Code No. of input transducer "J" : Approx. 10 to 10VDC VL : 0V, VH : 5V Automatic (trigger level is adjustable by internal trigger level V.R.) 24VDC, approx. 30mA (for Model Code No. of input transducer "D" Detects transducer failure and causes the 4 to 20mADC (1 to 5VDC) output to go to less than 0.8mADC (0.2VDC). 24VDC10 or 85 to 264VAC/DC 50/60Hz 24VDC 5.0W, 110VDC 5.0W, 100-240VAC 10VA 100M minimum at 500VDC between input output power GND mutually 2,000VAC for one minute between input output power GND mutually. with VM-21H : 1,000VAC between output GND 0 to 50 (32 to 122 F REF.) 10 to 90RH no condensation Modified polyphenylene oxide black Approx. 110g 0.24lb Only as for 24VDC power supply specifications.
2,000VAC for one minute between input output power GND mutually. with VM-21H : 1,000VAC between output GND. 0 to 50 (32 to 122 F REF.) 10 to 90RH no condensation Modified polyphenylene oxide (black) Approx. 110g 0.24lb Only as for 24VDC power supply specifications.
Specifications, outline drawings and other written information can be changed without notice.
2 Measuring by manual trigger is recommended in case that duty ratio of input signal is without 10 to 90% or input frequency is measured under 1 to 10Hz. Specifications, outline drawings and other written information can be changed without notice.
Block Diagram
VM-21K Displacement Input Vibration
VM-21P
Power supply
1 2 24VDC 100 to 240VAC/DC
S
Full range of input LVDT
050 100 150 200 250 300 350 400 450 50mm 100mm 150mm 200mm 250mm 300mm 350mm 400mm 450mm 1 2
BUF Buffered output 6 5 2 3 1 Input abnormal detector Isolation circuit Output circuit 7 9 OUT Output COM Input processing circuit Band pass Filter Rectification circuit ZERO/SPAN adjusting circuit Z S
Output
1 to 5VDC 4 to 20mADC
Measuring range
20 21 22 23 24 25 26 27 28 30 31 25mm 50mm 75mm 100mm 150mm 200mm 250mm 300mm 350mm 400mm 450mm S
Input LVDT
LS Series
Conditioner socket
0 1 Without Include
Note) Standard specifications, when measuring range and full range of input LVDT are the same. Satisfy the following when using LS Series LVDT : Full range of input LVDT 1 2 Measuring range Satisfy the following when using single coil type LVDT except LS Series LVDT : 1) Impedance At 50 (Null point) 500 to 700 (between A and C) Within LVDT stroke More than 400 Core comes out Less than 250 2) 4.33 LVDT sensitivity (mV/mm/V) Measuring range (mm) 1,000 This signal conditioner does not support the zero shift function, so the null point is always the center position of measurement.
VM-21D
Power supply
1 2 24VDC 100 to 240VAC/DC
Input LVDT
F
BUF 6 5 2 3 Constant current circuit Band pass filter Velocity / Acceleration Rectification circuit Displacement / velocity
Full range of input LVDT
100 250 300 400 100mm 250mm 300mm 400mm 1 2
Measuring range
21 23 24 25 26 27 30 50mm 100mm 150mm 200mm 250mm 300mm 400mm F
Output
1 to 5VDC 4 to 20mADC
LF Series
Integration circuit
S
7 OUT Output COM L+ Supply
Note) Standard specifications, when measuring range and full range of input LVDT are the same. Satisfy the following when using LF Series LVDT : Full range of input LVDT 2 Measuring range This signal conditioner does not support the zero shift function, so the null point is always the center position of measurement. 1
9 10
Specification
Model Input LVDT Measuring Range Output (isolated) I/O Conversion Accuracy Response Speed Polarity Burn-down Function1 T.P. Output (test point output for confirmation null point) Supply Permissible Voltage Power Consumption Insulation Resistance Withstanding Voltage Operating Temperature Relative Humidity Casing Material (color) Weight CE Marking
Can be changed by wiring Detects transducer failure and causes the 4 to 20mADC (1 to 5VDC) output to go to less than 0.8mADC (0.2VDC) Output 0V when core position is on Null point. Output impedance 100 Output 0V when core position is on Null point. Output impedance 1k 1 to 5VDC (output resistance
11 N8 GND
600 or less)
1 of F.S. at 25 , 2 of F.S. at 0 to 50 Deviation from an ideal linear output of voltage or current in combination with LS Series LVDT. However, when measuring range and full range of input LVDT are the same. 45ms, 90
1.5 of F.S. at 25 , 3 of F.S. at 0 to 50 Deviation from an ideal linear output of voltage or current in combination with LF Series LVDT. However, when measuring range and full range of input LVDT are the same. response
VM-21A
Vibration
Wave output
WAVE BUF
4 6 5 2 3
Constant current circuit Band pass filter
Output for LVDT Excitation Voltage : 5Vrms, Frequency : 3kHz, Max. current : 50mA, Sine wave Voltage : 7Vrms, Frequency : 1kHz, Max. current : 35mA, Sine wave
24VDC 10% or 85 to 264VAC/DC (50/60Hz) 24VDC : 3.5W, 110VDC : 3.5W, 100-240VAC : 10VA 100M minimum at 500VDC between input output power GND mutually. 2000VAC for one minute between input output power GND mutually. (with VM-21H : 1,000VAC between output GND.) 0 to 50 (32 to 122 F REF.)
Integration circuit
10 to 90%RH (no condensation) Modified polyphenylene oxide (black) Approx. 110g (0.24lb) Only as for 24VDC power supply specifications.
7
Isolation circuit Output circuit
9 10
*1 Abnormal condition When there is an abnormality in the LVDT or signal cable (breaking in LVDT wiring, breaking or short circuit in signal cable). However, VM-21D may be some instances where these conditions will not be detected. When there is an abnormality in LVDT excitation output (oscillation has stopped).
11 8
VM-21FTemperature
Power supply
1 2 24VDC 100-240VAC/DC
VM-21F
Output
1 2 1 to 5VDC 4 to 20mADC
Measuring range
1 9 0 to 100 Other TK TE TJ TT TR TS TB TN
Conditioner socket
0 1 Without Include
Thermocouple Type K Thermocouple Type E Thermocouple Type J Thermocouple Type T Thermocouple Type R Thermocouple Type S Thermocouple Type B Thermocouple Type N
R1 R2 R3 R4 MV
Small and light-weight Selectable mounting types Power supply options
With the use of VM-21G stand-alone sockets, the VM-21 signal conditioners require the space of mere 30mm width for mounting. VM-21 only weights 100g, and it has achieved the total minimization. Example of 8 module mounting
Block Diagram
VM-21FTemperature
mV IN RTD Thermocouple IN(A) IN(B) IN(B) Handy Terminal IN
Burn-down function Waveform output for machine diagnostics
VM-21 has buffered output of raw waveform signal available for diagnostics of rotating machinery. The signal can be sent to analysis and diagnostics equipment for spectral and vector analysis. Each of VM-21 module has an input abnormal detecting function, which sends out burn-down output (less than 0.8mADC or 0.2VDC) as soon as input abnormality, such as sensor breaking, occurs. This special feature can be a great contribution to the reliability of a plant operation.
Both the wall-mounting and DIN-Railmounting are available with VM-21G stand-alone socket for an easy mounting design.
A variety of power supplies are available: 100 to 240VAC, 100 to 24VDC and 24VDC.
Conventional model
1 3 4 Power supply circuit Input Processing circuit Microcomputer Isolation circuit Output circuit
7 9
VM
-11 g
48 (38 4)
COM
COM
RJC
10 L + 11 N8 GND Supply
260
New model
Wide module lineup to meet various vibration sensors Isolated output signal
VM-21 product lineup caters for various vibration sensors of displacement, velocity and acceleration.
(24 0)
VM
Specification
Model Input Transducer Input Resistance Input External Resistance RTD Detective Current Permissible Applicable Voltage
Thermocouple : -200 to 1200 Type K : -200 to 800 Type E : 0 to 750 Type J : -200 to 350 Type T : 0 to 1600 Type R Type S Type B Type N Type W3 Type W5
-21 0g *
ket
VM-21F Temperature
Thermocouple, RTD and mV signal (DC voltage) 1M(When Input Transducer is Thermocouple or mV signal) Thermocouple, mV signal : 500 or less Note : when combination with barrier (BARD600 : YOKOGAWA), it is the value connectable as external resistance besides internal resistance. RTD : input span ()0.4 or less / wire Note : when combination with barrier (BARD700 : YOKOGAWA), it is the value connectable as external resistance besides internal resistance.
* in c
16
lud ing
Each module of VM-21 has isolation circuit. This prevents such trouble as unstable output from signal cross-talking, often found in the instrumentation field.
soc
30
Approx. 0.5mADC 4VDC or less : 0 to 1600 : 600 to 1700 : -200 to 1200 : 0 to 2000 : 0 to 2000 RTD Pt100(ITS-90) PT100(IPTS-68) JPt100(JIS'89) Pt50(JIS'81) : -200 to 660 : -200 to 660 : -200 to 510 : -200 to 649
Outline Drawing
VM-21 Signal Conditioner VM-21G Signal Conditioner Socket
No. Name Input terminal Output/Power supply terminal Mounting hole
26
*1
Measuring Range
0.1 of F.S. at 25 Note : This value is limited in the following cases. <Input Transducer : RTD> <Input Transducer : Thermocouple> Input range is -10 to 100mV, span is under 27.5mV, in thermally generated emf conversion. Input range is 0 to 520, span is under 130 (refer to the reference resistance table) Accuracy(%)0.1%27.5mV/Input span[mV] Accuracy(%)0.1%130/Input span[] Input range is -2.5 to 25mV, span is under 10mV, in thermally generated emf conversion. Input range is 0 to 176, span is under 38.6 (refer to the reference resistance table) Accuracy(%)0.1%10mV/Input span[mV] Accuracy(%)0.1%38.6/Input span[] Attaching externally 1 (except for Type R, S) ; 2 (Type R, S) for terminal temperature 2515 160ms, 63 response (input change 10 to 90% 24VDC10 or 85 to 264VAC/DC 50/60Hz
70.8
3 4.2
DIN rail
Reference Junction Compensation for Thermocouple Reference Junction Compensation Accuracy Response Speed Supply Permissible Voltage Power Consumption Insulation Resistance Withstanding Voltage Operating Temperature Relative Humidity Casing Material (color) Weight CE Marking
24VDC 2.5W, 110VDC 2.9W, 100-240VAC 6.7VA 100M minimum at 500VDC between input output power GND mutually.
2,000VAC for one minute between input output power GND mutually. with VM-21H : 1,000VAC between output GND. 0 to 50 (32 to 122 F REF.) 10 to 90RH (no condensation) Modified polyphenylene oxide (black) Approx. 170g (0.37lb) Only as for 24VDC power supply specifications.
10.5 84
Dimension : mm
*1
(72)
59
6 22 16.5 (30)
2 The output mode is not changeable on the field. Specifications, outline drawings and other written information can be changed without notice.
(6.4)
(29.5)
*1 Refer to specifications page on terminal arrangement.
Dimension : mm