AL RAHA BEACH DEVELOPMENT ABU DHABI ALDAR PROPERTIES

MDB-1_23042011 Apr 23, 2011 / RAJINI

Symbols legend:
Symbol [Unit] ai cos ftot Ia/In Ib [A] Iz [A] Icu(fuse) [kA] Icu [kA] Ics [kA] Icu/Ics [kA] required Icw 1s [kA] In [mA] Ik1max Ik1min Ik3max Ik3min Ik1D [kA] Ik3D [kA] Ikmax/Ikmin Ikre In [A] P0 [kW] Pk [kW] Pmech [kW] Pn [kW] R0 N [m] R0 PE(N) [m] R0/R1 r1 [%] Description Load factor [Duty / Standby] Power factor Derating factor Inrush current relation Identify for motor starting current [eg: VFD/DOL/SDS] Operating current / allowed load capacity Rated ultimate short-circuit breaking capacity - fuse Rated ultimate short-circuit breaking capacity according to IEC 60947-2 Rated short-circuit breaking capacity the required breaking capacity of the protection device at installation location Rated short-time withstand current 1s Residual current - RCD Maximum single phase short-circuit current Minimum single phase short-circuit current Maximum three phase short-circuit current Minimum three phase short-circuit current single pole uninterrupted short-circuit current three pole uninterrupted short-circuit current Relation of maximum and minimum short-circuit current Short-circuit current recovery factor Nominal current No-load losses Short-circuit losses Mechanical Power Active power Zero phase-sequence resistance phase-neutral conductor Zero phase-sequence resistance phase-PE(N) conductor Resistance relation positive / zero phase-sequence system Relative value of positive phase-sequence resistance

Page 21/23

AL RAHA BEACH DEVELOPMENT ABU DHABI ALDAR PROPERTIES

MDB-1_23042011 Apr 23, 2011 / RAJINI

R1 [m] Sn [kVA] ukr [%] Un [V] Uprim [kV] Usec [V] X0 N [m] X0 PE(N) [m] X0/X1 X1 [m] xd'' [%] Z1 max Z1 min Zs Zs max Zs min u [%] / u [%] u [C] / Ikmax [C] / Ikmin [C] [] 1 min/max [] 3 min/max []

Positive phase-sequence resistance Nominal apparent power Short-circuit voltage Nominal voltage Primary voltage Secondary voltage Zero phase-sequence reactance phase-neutral conductor Zero phase-sequence reactance phase-PE(N) conductor Reactance relation positive / zero phase-sequence system Positive phase-sequence reactance Subtransient reactance Maximum impedance in positive phase-sequence system Minimum impedance in positive phase-sequence system Faulted circuit impedance Maximum faulted circuit impedance Minimum faulted circuit impedance voltage drop between beginning and end of a section / cumulated voltage drop from the transformer primary/ secondary clamps to the specified point Conductor temperature of MV cable / Conductor temperature of LV cable for voltage drop / on beginning of short circuit / for disconnection Efficiency Phase angle Phase angle at Ik1 min/max Phase angle at Ik3 min/max

Page 22/23

AL RAHA BEACH DEVELOPMENT ABU DHABI ALDAR PROPERTIES

MDB-1_23042011 Apr 23, 2011 / RAJINI

Standards for computation:


Title Low-voltage electrical installations Short-circuit currents in three-phase a.c. systems Calculation of currents Short-circuit currents calculation of effects Definitions and calculation methods Low-voltage switchgear and controlgear Circuit-breakers Low-voltage switchgear and controlgear assemblies A method of temperature-rise assessment by extrapolation for partially typetested assemblies (PTTA) of low-voltage switchgear and controlgear Application of cables and cords in power installations Recommended currentcarrying capacity for sheathed and nonsheathed cables for fixed wirings in and around buildings and for flexible cables and cords Electrical accessories Circuit-breakers for overcurrent protection for household and similar installations Circuit-breakers for a.c. operation High-voltage switchgear and controlgear Alternating Current switch-fuse combinations 60898-1 62271 IEC 60364-16 60909 60865 60947-2 60439 60890+C 528 S2 HD 384 60909 60865 60947-2 60439-15 EN DIN VDE 0100 100...610 0102 0103 0660 101 0660 500505 0660 507

384

0298 4

60898-1 62271

0641 11 0671 105

Page 23/23