BATTERY CHARGER

FEATURES
n Micro controller based design n PI control logic to regulate output n Soft start for output voltage n Auto/Manual mode charging n Constant voltage (Float mode) and

BC 9080 GENERAL DESCRIPTION


ICD Battery Charging equipment is manufactured according to IS standards both in construction and performance wise. The charging equipment is designed to supply required DC current to recharge the battery and also supply the constant DC load of the system. Battery chargers are micro controller based design with thyristor power devices. The chargers provide regulated DC output continuously from an AC source. The charger maintains the battery on float voltage on completion of charging. The batteries will be charged in float mode between 1.75V to 2.4V and in boost mode 1.88V to 2.66V. The charger is capable of automatically switching from float mode to boost mode and boost mode to float mode depending on the current drawn by the battery. The rectifier transformer & chokes are dry type and air-cooled with class F insulation. Mains isolation/protection is provided through MCB and contactor. Suitable fuses are also provided in the mains and rectifier side. All meters, control switches, indication lamps, ON/OFF switches are mounted on the hinged front door. The charger cubicle is made out of sheet steel and angle iron frame fabrication. The enclosure is dust and vermin proof self standing, floor mounting type with bottom cable entry through removable gland plates. The components housed inside the panel are accessed by opening front and back door.

constant current (Boost mode) charging selected automatically


n Less DC ripple content with LC Filter n Digital Panel meter are provided in the

front panel for input voltage and current, Output voltage and current
n Protection against

a) Abnormal AC input b) Battery Reverse c) Over voltage and over current


n Isolated voltage and current feedback

taken using hall sensors


n Wide range of charger available

12V/24V/48V/110V/220V current upto 150A maximum

APPLICATIONS
n Substation Battery Charging n NI-CD Batteries and railway

traction Batteries
n Diesel Generator set Batteries n Telecom Battery Charging

TECHNICAL SPECIFICATION
Model No. Type : BC 9080 : ICD Make float cum boost battery charger (Thyristor Control Type) Protection Trip : a) b) c) d) : a) b) c) d) e) : a) b) c) d) e) f) Over voltage Over current AC Fail Battery Reverse AC Input on/off MCB DC Output on/off MCB/MCCB AC Input HRC fuse Semi conductor fuse for Thyristor HRC fuse for filter capacitor AC Input on/off MCB DC Output on/off MCB/MCCB Auto / Manual selector switch Float / Boost selector switch Float voltage variable potentiometer Boost voltage variable potentiometer

Supply Input Voltage : 415V AC -20% to+10% 50Hz, 3 Phase (or) 240V AC -20% to+10% 50Hz, 1 Phase Front End Circuit : Step down Transformer with Necessary Protection Output Voltage for Battery Voltage Regulation Output Ripple : 12V / 24V / 48V / 110V / 220V Battery banks : 1% : Less than 2% RMS at Full Load L-C Filter Provided

Protection Circuit

Front Panel Control

Rectifier Configuration: 3 Phase / 1 Phase Fully Controlled Thyristor Module is used with dv / dt protection : Auto / Manual Selected through Selector Switch Mode of Charging : Float / Boost Charging. In Auto Mode Float / Boost Charging Operation take place depending on the Battery condition. In manual mode Float / Boost Charging selected through selector switch Manual Mode Setting : Through Potentiometer Metering Facility : a) b) c) d) : : AC Voltmeter AC Ammeter DC Voltmeter DC Ammeter ICD Make Digital LED Type 96(H) x 96(W) x 80(D)mm Mode of Operation

Special Features

: a) Soft start for DC output b) Class-F insulation for all Magnetics c) Voltage regulation using digital controlled PI logic d) LC Filter circuit to limit ripple content e) Automatic float to boost and boost to float change over based on the Current drawn by the battery : a) AC Input terminals b) DC Output terminals for battery c) DC Output terminals for load (optional) : Free standing, Floor mounting type Sheet steel construction, Front door Access, Sides and Back removable plates : Through bottom of the panel : Forced air-cooling : Maximum 50C : 10C Above Ambient (Maximum)

Terminals

Cabinet

Meter Type & Make Meter Dimension

Cable Entry Cooling Ambient Temperature Temperature Rise

OPTIONAL FEATURES
The battery chargers can be made as per required configuration depending on the need of the application
n Float cum boost charger with single

set of transformers, rectifiers and control circuit


n Float cum boost charger with

separate transformer, rectifier and control circuit

OUR RANGE OF PRODUCTS


Volt Meter, Ammeter, VAF Meter, Energy Meter, Dual Source Meter, Load Manager, Power Multimeter, Trivector Meter, Maximum Demand Controller, Harmonic Indicator, Power Factor Controller, Smart PF Controller, Power Factor Correction Panel, AC Voltage Controller, AC Current Controller, Motor Protection System, Voltage/Current/Power/Frequency Transducer, Power Transmitter, Energy Management and Billing Systems etc...