We touch your electricity everyday!

CSE NEXM

* Compact & Drawout Design * Versatile & Programmable Relay * Rated 1A/5A - 50/60 Hz Site Selectable * Wide Range Auxiliary Supply

L1 : L2 : L3 :

0000.0A 0000.0A
0000.0A

CSE NEX-1A

/5A-50/60H

CSENEX-M
Motor Protection & Monitoring System
Application

The CSENEX-M relay is the ideal answer to problems requiring more versatile or accurate protection for a motor with thermal modeling. It employs the latest technique for the protection of medium & large sized three phase AC motors with high inertia load in all type of ordinary contactors controlled or circuit breaker controlled motor drives. It handles fault condition during motor start up, normal run, idling and cooling down at standstill in all industrial application like pump, fan, mill, crusher etc.

Main Features:

1A & 5A combined CT input programmable Drawout design with self CT shorting SCADA communication (local & remote) Wide auxiliary supply range DI / DO matrix programmability Event record Fault record

Series

Protection & Control Over current (50/51P) Sensitive ground fault (50/51N) Negative sequence over current (46) Thermal over-load (49) Phase loss (37) Lock rotor (50LR) Stall (50S) Two level short circuit for start & run Thermal alarm Speed switch

Metering & Monitoring Current, NPS, Thermal capacity Motor running time, Total no. of trips Communication Modbus RTU on RS-485

Electronic Division
Unit - Protection & Control

We touch your electricity everyday!


Wiring Diagram (CSENEX-M)
Power Supply
AC/DC A3 L1 L2 L3
D1

CSENEX-M
Earth

A2 A1

DI 1
DIGITAL INPUT
P1 S1

E1 E2
IL1

D4

DI 2 DI 3

(D2 IS COMMON D2 FOR DI1, DI2 & DI3) D3

P2

S2

P1

S1

E3
IL2

D5

DI 4
D6

P2

S2

E4

P1

S1

E5
IL3

A18

P2

S2

E6
DIGITAL OUTPUT

D0 1

A17 A16 A15

E7
Motor

D0 2

A14 A13

E8

IE

D0 3 D0 4

A12 A11

A5

P1 N1

A10 A9

RS-485

A4

Technical Data Auxiliary voltage Uaux Rated phase current Ip -current measuring range Rated neutral current In Thermal withstand capability in current circuit 24-260V AC/DC 1A & 5A (site selectable) 25xIp 1A & 5A (site selectable) At Ip = 1A Continuous = 5xIp for 10 Sec = 30xIp for 1 Sec = 100xIp Rated frequency Fn Digital inputs (external voltage) Trip contacts 50/60 Hz 4 programmable 4 programmable

Records Event recorder Fault recorder Tests & Environment 50 (non volatile memory with time stamp) 10 (non volatile memory with time stamp) IEC 60255 / 60068

(EMC Emission / Emmunity / Mechanical / EMI) Operating temperature Degree of protection Weight Dimension (WxHxD) 70 C IP54 1.1 kg 125.0x156.0x158.5 mm
0

C&S Electric Limited


(Protection & Control Division)
44, Okhla Industrial Estate, New Delhi -110 020 (INDIA) Phone : +91 11- 66602414, 30883745/54/64 Fax: +91 11- 66602413 E-mail: cspc@cselectric.co.in
Rev. No.: 02 Rev. Date: 28.09.11 Issue Date: 07.09.11

Branch Offices :
Ahmedabad:+91 79 30074534/35/36 Fax:+91 79 30074519 Bangalore:+91 80 3057 0372/73, 3057 0347 Fax:+91 2558 4839 Bhubaneswar:+91 674 2507265 Fax:+91 674 2507265 Chennai:+91 44 3918 0531-35 Fax:+91 44 39180514 Cochin:+91 0484 3071717 Fax: +91 0484 3071716 Delhi:+91 11 30838822-25 Fax:+91 11 30838826 Hyderabad:+91 40 3918 2496/97 Fax:+91 40 3910 3631 Kolkata:+91 33 22275850/51 Fax: +91 33 2227 5849 Mumbai:+91 22 30487146/47/48 Fax:+91 22 2412 6631 Pune:+91 20 30283244/45 Fax:+91 20 30283244

For more details please visit us at : www.cselectric.co.in