Hydraulic/Gas Buffer BP

440 420 400 380 360 340 320 300 Max. Absorbing Capacity per Stroke in kJ

BP 12 5

280 260 240 220 200

BP 100

180 160 140 120 100 80

BP

80

DIN ISO 9001 : 2000 QA-Nr.: 04100 19950241

6 BP

60 40 20

BUBENZER BREMSEN is certified according to DIN EN ISO 9001:2000


100 200 300 400 600 800 Stroke in mm

Reliable

Efficient

Low Maintenance

Robust Construction

I1

Description BP Buffer

Main Features
Piston and cylinder of special seamless pipes Back mounted or front mounted versions available Synthetic impact plate on buffer head Piston special hard chrome plated Metering pin exchangeable on site Service/repair possible on site Seawater resistant coating Impact speed sensitive damping

Options
Special mounting arrangements High temperature seals Safety chain Safety wire rope Protective bellows Special designs for certain applications

Ordering Example
Type Execution (diameter) Stroke + Pin Code Mounting Flange
F = Front Mounted E = Back Mounted

Applications
As impact energy absorber on crane gantries, trolleys, elevators, stackers, reclaimers and other industrial applications.

Operating Restrictions BP 100 - 410 - F


Buffers of this range are tested before shipment. Operating conditions other than described in this catalogue require the manufacturers approval and may influence the function of the buffer.

Please Note
We supply a detailed operating manual with every order. Nevertheless, we would point out that buffers are only as safe as the servicing and maintenance performed while they are in operation. The guarantee for the correct functioning of our buffers is therefore only valid if the user adheres to the installation and operating manual.

Bubenzer Service
This includes the verification of the buffer selection, if required. A detailed questionnaire is provided for this purpose. Installation and commissioning at site is possible by Bubenzer service engineers. Drawings as DWG/DXF files for your engineering department are available upon request.

I2

Buffer Type BP 65
Dimensions and technical data Rev. 11-03

Stroke

* upon request
F = Front Mounted E = Back Mounted All dimensions in mm Alterations reserved without notice

Stroke mm 100 200 300 400 600 800

Capacity kJ/stroke 17 34 51 58 77 82

End force kN 200 200 200 170 150 120

L1 495 805 1100 1395 1890 2455

L2 250 350 450 580 780 980

L3 245 455 650 815 1110 1475

L4 75 75 75 75 75 75

L5 150 150 150 150 * *

d1 93 93 93 93 93 93

d2 108 108 108 108 108 108

d3 65 65 65 65 65 65

d4 85 85 85 85 85 85

Impact Weight and Pin Codes Stroke mm 100 200 300 400 600 800 up to up to up to up to up to up to up to up to 5 t 10 t 20 t 40 t 80 t 150 t 300 t 600 t 102 202 302 402 602 802 104 204 304 404 604 804 106 206 306 406 606 806 108 208 308 408 608 808 110 210 310 410 610 810 112 212 312 412 612 812 114 214 314 414 614 814 116 216 316 416 616 816

Weight kg Execution F E 19,2 25,2 31,4 37,3 44,9 56,3 19,2 25,2 33,7 39,6 * * Restoring Force kN 10 10 11 12 25 25 I3

Buffer Type BP 80
Dimensions and technical data Rev. 11-03

Stroke

* upon request
F = Front Mounted E = Back Mounted All dimensions in mm Alterations reserved without notice

Stroke mm 100 200 400 600

Capacity kJ/stroke 30 60 102 128

End force kN 350 350 300 250

L1 470 755 1315 1885

L2 280 360 670 870

L3 190 395 645 1015

L4 75 75 75 75

L5 150 150 150 *

d1 113 113 113 113

d2 128 128 128 128

d3 80 80 80 80

d4 105 105 105 105

Impact Weight and Pin Codes Stroke mm 100 200 400 600 I4 up to up to up to up to up to up to up to up to up to 5 t 10 t 20 t 40 t 80 t 150 t 300 t 600 t 800 t 102 202 402 602 104 204 404 604 106 206 406 606 108 208 408 608 110 210 410 610 112 212 412 612 114 214 414 614 116 216 416 616 118 218 418 618

Weight kg Execution F E 23,6 32,6 49,3 66,2 24,3 33,3 50,0 * Restoring Force kN 25 25 25 25

Buffer Type BP 100


Dimensions and technical data Rev. 11-03

Stroke

* upon request
F = Front Mounted E = Back Mounted All dimensions in mm Alterations reserved without notice

Stroke mm 200 400 600 800

Capacity kJ/stroke 80 150 204 241

End force kN 470 440 400 355

L1 780 1350 1920 2490

L2 470 670 870 1070

L3 310 680 1050 1420

L4 85 85 85 85

L5 190 190 * *

d1 133 133 133 133

d2 148 148 148 148

d3 100 100 100 100

d4 125 125 125 125

Impact Weight and Pin Codes Stroke mm 200 400 600 800 up to up to up to up to up to up to up to up to up to up to up to 5 t 10 t 20 t 40 t 80 t 150 t 300 t 600 t 800 t 1000 t 2000 t 202 402 602 802 204 404 604 804 206 406 606 806 208 408 608 808 210 410 610 810 212 412 612 812 214 414 614 814 216 416 616 816 218 418 618 818 220 420 620 820 222 422 622 822

Weight kg Execution F E 53,4 76,1 98,8 121,5 57,4 80,1 * * Restoring Force kN 30 30 30 30 I5

Buffer Type BP 125


Dimensions and technical data Rev. 11-03

Stroke

* upon request
F = Front Mounted E = Back Mounted All dimensions in mm Alterations reserved without notice

Stroke mm 200 400 600 800

Capacity kJ/stroke 120 238 337 422

End force kN 700 700 660 620

L1 745 1275 1775 2295

L2 470 680 930 980

L3 275 595 845 1315

L4 85 85 85 85

L5 190 190 * *

d1 148 148 148 148

d2 163 163 163 163

d3 125 125 125 125

d4 150 150 150 150

Impact Weight and Pin Codes Stroke mm 200 400 600 800 I6 up to up to up to up to up to up to up to up to up to up to 10 t 20 t 40 t 80 t 150 t 300 t 600 t 800 t 1000 t 2000 t 204 404 604 804 206 406 606 806 208 408 608 808 210 410 610 810 212 412 612 812 214 414 614 814 216 416 616 816 218 418 618 818 220 420 620 820 222 422 622 822

Weight kg Execution F E 61,7 87,4 111,0 136,0 71,7 97,7 * * Restoring Force kN 55 55 65 65

You might also like