Submersible pump C 3127, 60 Hz

C 3127
7G2,5+2x1,5 mm2 7G4+2x1,5 mm2

VFD Application
NSSHU../3E+St 3x2,5+3x2,5/3E+3x1,5 St

Monitoring equipment
Thermal contacts opening temperature 125 C

Material
Impeller Pump housing Stator housing Shaft O-rings Mechanical face seals Cast iron Cast iron Cast iron Stainless steel Nitrile rubber

C 3127
Product
Submersible pump for pumping clean water, surface water and waste water containing solids or long-fibred material.

Alternative 1

Inner seal Carbon/Aluminium oxide

Outer seal Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide Silicone carbide/ Silicone carbide

Denomination
3 Product code Installation Impeller characteristics 3127.181 P, S, T, Z LT, MT, HT, SH

Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide

Process data
Liquid temperature Depth of immersion The pH of the pumped liquid Liquid density Impeller throughlet max +40 C max 20 m pH 5,5-14 max. 1100 kg/m3 See Motor rating table

Surface Treatment
All cast parts are primed with a water-borne primer. The finishing coat is a high-solid two pack paint.

Weight
See dimensional drawing.

Option
3127.090 3127.980 Ex. proof design Industrial design FLS CLS Epoxy treatment

Motor data
Frequency Insulation class Voltage variation - continuously running - intermittent running Voltage imbalance between phases No. of starts/hour max 5% max 10% max 2% max 30 60 Hz H (+180 C)

Warm liquid version on request Leakage sensor in stator housing Leakage sensor in oil housing Surface treatment Other cables Zinc anodes

Cable
Direct-on-line start
SUBCAB 4G2,5 mm 2 4G2,5+2x1,5 mm2 4G4 mm2 4G4+2x1,5 mm2

Accessories
Discharge connections, adapters, hose connections and other mechanical accessories. Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables. See separate booklet or www.flygt.com, for further information.

Y/D start
SUBCAB 7G2,5 mm 2

C 3127
LT-Motor rating and performance curve
Ex proof version available Impeller thoughlet, mm

12 8 10 7 8 6 6 5

P2 [kW] / [hp]

Curve/Impeller No

Rated power, kW

Starting current, A

Power factor cos

411 442

Rated current, A

412

Installation P S T Z

H [m] / [ft] 60 50 40 30 20 18 16 14

LT

460 V, 60 Hz, 3 ~, 1760 r/min 412 5,5 412 5,6 411 7,5 9,8 9,8 75,0 0,83 76 60,0 0,85 76 Yes Yes Yes Yes 460 V, 60 Hz, 3 ~, 1750 r/min 460 V, 60 Hz, 3 ~, 1745 r/min 13,0 75,0 0,87 76 13,0 75,0 0,87 76 412 7,5 442 7,5 412 5,6

12 10 8 6 4
442 411

13,0 75,0 0,87 100 Yes 30,0 58,0 0,96 76 Yes

230 V, 60 Hz, 1 ~, 1745 r/min

Y/D starting current is approximately 1/3 of D starting current.

10 2 0 0 0 0 20 200 400 40 600 800 60 80 100

412

1200 1600 1800 1000 1400 Q [l/s] / [usgpm]

C 3127
MT-Motor rating and performance curve
Ex proof version available Impeller thoughlet, mm

P2 [kW] / [hp] 10 8 6 4 7 6 5 4 3 H [m] / [ft]


434 436 433 432

Curve/Impeller No

Rated power, kW

Rated current, A

Starting current, A

Power factor cos

Installation P S T Z

70 20 60 50 40 30 8 20 4
434 436 433

MT

460 V, 60 Hz, 3 ~, 1755 r/min 433 4,8 434 4,8 436 4,8 433 5,5 434 5,5 436 5,5 433 5,6 434 5,6 436 5,6 432 7,5 433 7,5 434 7,5 436 7,5 8,5 8,5 8,5 9,8 9,8 9,8 9,8 9,8 9,8 60 60 60 75 75 75 60 60 60 0,83 82 0,83 80 Yes Yes

16 12

0,83 100 Yes 0,83 82 0,83 80 Yes Yes

460 V, 60 Hz, 3 ~, 1760 r/min

0,83 100 Yes 0,85 82 0,85 80 Yes Yes

460 V, 60 Hz, 3 ~, 1750 r/min

10 0

432

0,85 100 Yes Yes Yes Yes

460 V, 60 Hz, 3 ~, 1745 r/min 13,0 75,0 0,87 87 13,0 75,0 0,87 82 13,0 75,0 0,87 80

0 0 0 10 200 20 30 40 600 50 60 70 80 400 800 1000 1200 1400 Q [l/s] / [usgpm]

13,0 75,0 0,87 100 Yes

230 V, 60 Hz, 1 ~, 1745 r/min 433 5,6 434 5,6 30,0 58,0 0,96 82 30,0 58,0 0,96 80 Yes Yes

Y/D starting current is approximately 1/3 of D starting current.

C 3127
HT-Motor rating and performance curve
Ex proof version available Impeller thoughlet, mm

12 8 10 8 6 7 6 5 4

P2 [kW] / [hp]
481 483

Curve/Impeller No

Rated power, kW

Rated current, A

Starting current, A

Power factor cos

484 485

Installation P S T Z

H [m] / [ft]

HT
100 30 25
481

460 V, 60 Hz, 3 ~, 1760 r/min 485 5,5 485 5,6 481 7,5 483 7,5 484 7,5 485 7,5 9,8 9,8 75,0 0,83 76 60 0,85 76 Yes Yes Yes Yes Yes Yes 460 V, 60 Hz, 3 ~, 1750 r/min 460 V, 60 Hz, 3 ~, 1745 r/min 13,0 75,0 0,87 76 13,0 75,0 0,87 76 13,0 75,0 0,87 76 13,0 75,0 0,87 76

80

20 60 15 40 10 20
Yes Yes Yes Yes

230 V, 60 Hz, 1 ~, 1745 r/min 462 5,6 463 5,6 484 5,6 485 5,6 30,0 58,0 0,96 56 30,0 58,0 0,96 46 30,0 58,0 0,96 76 30,0 58,0 0,96 76

5
485

484 483

0 0 10 20 30 40 50 0 100 200 300 400 500 600 700 800 900 Q [l/s] / [usgpm]

Y/D starting current is approximately 1/3 of D starting current.

C 3127
SH-Motor rating and performance curve
Ex proof version available Impeller thoughlet, mm

16 14 12 10 8 11 10 9 8 7 6

P2 [kW] / [hp]

Curve/Impeller No

Starting current, A

Power factor cos

Rated power, kW

Rated current, A

257

258

259

Installation P S

H [m] / [ft]

SH
200 60
257

460 V, 60 Hz, 3 ~, 3510 r/min 257 8,2 258 8,2 259 8,2 13 13 13 113 113 113 0,91 40 0,91 40 0,91 40 Yes Yes Yes

160

50 40

258 259

Y/D starting current is approximately 1/3 of D starting current.

120 30 80 20 40 10 0 0 0 1 20 2 40 3 4 60 5 80 6 7 8 100 120 140 Q [l/s] / [usgpm]

C 3127
Dimensional drawing
All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Download the drawings from www.flygt.com or contact your ITT Flygt representative for more information. All dimensions are in mm.

LT, P-installation

LT, P-installation

C 3127
LT, S-installation LT, T-installation

LT, Z-installation

MT, P-installation

C 3127
MT, P-installation MT, P-installation

MT, S-installation

MT, S-installation

10

C 3127
MT, T-installation MT, T-installation

MT, Z-installation

MT, Z-installation

11

C 3127
HT, P-installation HT, P-installation

HT, P-installation

HT, P-installation

12

C 3127
HT, S-installation HT, S-installation

HT, T-installation

HT, T-installation

13

C 3127
HT, Z-installation HT, Z-installation

SH, P-installation

SH, S-installation

14

www.flygt.com

C3127.60Hz.04.01.EN.FIN.03.05. ITT Flygt AB