Water-Cooled Screw Chiller

Nominal Cooling Capacity: 335~1392kW

The 30HXC units are water-cooled chillers, designed from the ground up to meet the needs of today and tomorrow. It is distinguished for its chlorine-free refrigerant, high efficiency, high reliability, easy maintenance and low running cost. Born in 1990s, 30HXC is widely applied in all kinds of buildings such as hotels, offices, restaurants, schools, hospitals, enterprises, etc.

Designed exclusively for R134a


= =

R134a has zero ozone depletion potential. R134a production is annually increasing, and has no expire date.

Full/part load mode is more cost saving


06N twin-screw compressor achieves high efficiency. Carrier patent high efficiency flood evaporator increase heat transfer efficiency. = Multiple compressors allow flexible adjustment according to user's load, ensuring higher part-load efficiency. = Electronic expansion valve ensures high control precision.
= =

High reliability
Two independent refrigerant circuits minimize unit shut down. Multiple compressors provide back up for each other. = Complete protection function ensures the unit running smooth. = Each unit has a trial run in the factory.
= =

Easy installation
Compact design requires minimal indoor space. The maximum width reaches only 1015mm, which allows the unit to fit through a standard door opening without disassembly. = Evaporator and condenser short steel pipes and flanges are supplied by factory. = Refrigeration and lubrication is filled ex-factory. = The on-site installation requires only connection to water and power supply.
= =

Simple to service
= =

Graphical operational interface makes it clear and easy to operate. Screw compressor with few components requires low maintenance cost.

Triple Sound Reduction


Built-in sound reduction device can effectively reduce noises as result of high pressure air discharge fluttering by diverting the air in an appropriate way. = New external muffler installed on the discharge pipe on the compressor can transform part of acoustic energy into heat and greatly reduce noise. (See the picture below) = Sound reduction cabinet provides another sound-proofing barrier, and reduces the noise transferring to the machine room. (See the picture below)
=

Muffler on Discharge Pipe

2nd Generation Sound Reduction Cabinet

30HXC

PRO-DIALOG Plus is an advanced numeric control system that combines intelligence with great operating simplicity. The PID control algorithm with permanent compensation for the difference between the heat exchanger entering and leaving temperature, anticipates load variations, guarantees leaving water temperature stability and prevent unnecessary compressor cycling.

PRO-DIALOG offers extended communications capabilities


=Graphical =Touch

interface, LED numeric displays make it clear and easy to understand.

keys are well-positioned on the schematic chiller diagram, providing clear view of operation flow. All operating menus provide direct access to acquiring and modifying parameters.

parameters such as pressures, temperatures, operating hours etc are easy to use.
=Operating

PRO-DIALOG has advanced control functions


=Allows =The

local mode, remote mode and CCN mode to start/stop the unit.

long-stroke electronic expansion valve (EXV), allows a significant energy efficiency improvement at part load conditions, control of refrigerant circuits and compressors on/off status and loading sequence, thus equalizing compressor

and faultless chiller operation in a wider temperature range.


=Automatic

operating hours.
=Interlock

control between the unit, chilled water pump and cooling water pump, contributing to safe and high efficiency

performance.
=

"Demand Limit" limits the maximum chiller capacity to a predefined value. This function is specially designed for multicompressor management, it aims to achieve the best running efficiency by imposing different chiller capacity limit to different compressors.

=Evaporator

leaving water temperature drop speed is controlled within the adjustable range (0.1~1.1C/min) so as to avoid

energy waste, improve ERR and increase unit life.


=Provides

a negative revision to cooling water leaving temperature according to outdoor temperature or return water tempera

ture trend, so as to save energy and improve ERR by quickly fitting the wave trend of external load decrease.

Safety Protection Function


=Protection

on low cooling water leaving temperature, low oil pressure, high refrigerant pressure, electric leak, compressor

overload, high/low electrical voltage and phase lack.

Multiple remote control


=The

communication bus between RS485 port of 30HXC and the Carrier Comfort Net (need purchase) offers multiple remote

control; the communication bus between 30HXC and DATAPORT communication module provided by Carrier (need purchase) realizes the connection with other building automatics.

30HXC

30HXC Net nominal cooling capacity Compressors Quantity-CircuitA Quantity-CircuitB No.of control steps Minimum step capacity Evaporator Entering water temperature Leaving water temperature Net water volume Inlet/outlet Max.water side operating pressure Condenser Entering water temperature Leaving water temperature Net water volume Inlet/outlet Max.water side operating pressure Refrigerant charge Circuit A Circuit B Dimensions Length Width Height Net weight Operating weight mm mm mm kg kg kg kg C C I in kPa C C I in kPa % kW

130A 449

140A 509

155A 541

190A 651

230A 812

260A 897

285A 310A 985 1106

345A 1204

375A 1300

Semi-hermetic, twin-screw POWER3 1 1 6 19 1 1 6 17 1 1 6 19 1 1 6 21 2 1 8 14 2 1 8 14 2 1 8 14 2 2 10 10 2 2 10 10 2 2 10 10

Shell and tube with internally finned copper tubes 12 7 65 5 1000 75 5 1000 75 5 1000 88 5 1000 155 6 1000 170 6 1000 170 6 1000 191 8 1000 208 8 1000 208 8 1000

Shell and tube with internally finned copper tubes 30 35 78 5 1000 90 5 1000 90 5 1000 108 6 1000 190 8 1000 190 8 1000 190 8 1000 255 8 1000 255 8 1000 255 8 1000

HFC-134a 51 47 48 48 54 57 70 70 117 75 117 75 132 80 109 106 96 109 119 137

3278 980 1816 2474 2617

3278 980 1816 2537 2702

3278 980 1816 2547 2712

3278 980 1941 2983 3179

3912 1015 2060 4242 4602

3912 1015 2060 4296 4656

3912 1015 2060 4416 4776

4521 1015 2112 5014 5477

4521 1015 2112 5090 5553

4521 1015 2112 5258 5721

30HXC Power circuit Nominal power supply Voltage range Nomial power input* Nomial current drawn* Max.starting current V-ph-Hz V kW A A

130A

140A

155A

190A

230A

260A

285A

310A

345A 375A

400-3-50 360-440 90 161 298 102 190 333 112 198 355 130 234 442 164 300 1129 192 335 1027 196 348 1200 221 410 1129 251 432 1184 263 461 1373

Standard Eurovent conditions: Evaporator entering/leaving water temperature 12C and 7C. Condenser entering/leaving water temperature 30C/35C. Fouling factor=0.000044m2K/W Effective power input = power input of the compressors + the control circuit + the power input of the pump to overcome the evaporator pressure drop. Net cooling capacity = gross cooling capacity minus the water pump heat against the internal evaporator pressure drop. Short steel pipes factory-supplied, to be installed on site for evaporator and condenser water connections.

30HXC

30HXC 130A-190A

A 30HXC130A 30HXC140A 30HXC155A 30HXC190A 210 272

B 318 332

C 320 304

D 235 283

E 1816 1941

F 656 666

S Dg125 Dg125

R Dg125 Dg150

Required clearances for maintenance Recommended space for tube removal (clearance 2990 and 1000 can be either on the right or the left side).

30HXC

30HXC 230A-285A

A 30HXC230A 30HXC260A 30HXC285A 306

340 357.5 284 2060 Dg200 Dg150

Required clearances for maintenance Recommended space for tube removal (clearance 3600 and 1000 can be either on the right or the left side).

30HXC

30HXC 310A-375A

A 30HXC310A 30HXC345A 30HXC375A


Required clearances for maintenance

C 340

290 379

306 2112 Dg200 Dg200

Recommended space for tube removal (clearance 4200 and 1000 can be either on the right or the left side).

30HXC

Chiller Footprint

Dimension(mm) A 30HXC130A 30HXC140A 685 30HXC155A 30HXC190A 30HXC230A 30HXC260A 1092 30HXC285A 30HXC310A 30HXC345A 1399 30HXC375A

B 1828

C 3278

P 930

Q 100

R 980

1785

3912

965

100

1015

1659

4521

965

100

1015

Load(kg) 30HXC130A 30HXC140A 30HXC155A 30HXC190A 30HXC230A 30HXC260A 30HXC285A 30HXC310A 30HXC345A 30HXC375A

1 2 3 4 812 549 749 507 840 567 774 523 842 569 776 525 987 667 910 615 1348 958 1342 954 1364 970 1358 964 1399 995 1392 990 1786 1303 1381 1007 1811 1321 1400 1021 1865 1361 1443 1052

1 2 3 4 848 512 782 475 876 530 808 488 880 532 810 490 1030 623 950 576 1399 907 1393 903 1415 918 1408 915 1452 942 1445 937 1850 1239 1430 958 1875 1256 1450 972 1931 1295 1494 1001

Operating Weight

2617 2702 2712 3179 4602 4656 4776 5477 5553 5721

Field Wiring

0-10VDC 24VAC-48VDC MAX 20V-MIN

80mA MIN - 3A MAX 30A 31A 80mA MIN - 3A MAX 30B 31B

J3 CH24 +C CH25 +C J8 +C CH10 J4 CH11 +C CH12 +C CH13 +C CH14 +C CH15a +C

A1

2.5mm2 MAX.

0-10VDC

71 72 32 33 65 66 63 64 73 74 34 35

5mm2 MAX.

1.5mm2 MAX.

J12 GND CCN

24VAC,20mA
A155

30HXC

Standard Accessories
Item a b c d e Description Flow monitor switch for evaporator M20 300 hex screw Quantity 1 4 2 4 4

Handle of disconnect switch Couplings Short steel pipes

Main Options
Option 104EA16 107E 104CA16 107C ACC3 25 5 150A 150B Description Evaporator maximum water-side operating pressure of 21 bar Reversed evaporator water inlet/outlet Condenser maximum water-side operating pressure of 21 bar Reversed condenser water inlet/outlet RS485 communications interface with open protocol Compressor soft start(30HXC200A-375A)-electronic starter Brine unit for leaving brine <+4C to > -6C Water-to-water heat pump High condensing temperature unit and non-reversible heat pump Condenser leaving water < 47C to > 60C Condenser leaving water < 40C to > 47C Remark

30HXC

19XR
Hermetic Centrifugal Liquid Chiller
Norminal Capacity:1055~5274kW

30HXC
Water - Cooled Screw Chiller
Norminal Cooling Capacity:335~1392kW

30RB
Air Cooled Liquid Chiller
Cooling Capacity:193~753kW

16DE
Double Effect,Hermetic Absorption Liquid Chiller
Norminal Cooling Capacity:528~2321kW

16DN
Direct-Fired,Double Effect,Hermetic Absorption Liquid Chiller
Norminal Cooling Capacity:528~2321kW