VP40
3 Way Proportional Pressure Control Valve Nominal diameter 4, 6 and 8 Direct operated poppet valve Port sizes G 1/8 - G 3/8, 1/8 NPT - 3/8 NPT G Low hysteresis G Good repeatability G High flow capacity at exhaust port G High response sensitivity G Fast response time

Technical Data
Medium: Filtered air, lubricated or unlubricated, Filter 40 m Operation: Proportional solenoid Port Size: G 1/8 - G 3/8, 1/8 NPT - 3/8 NPT Female thread Flow direction: Fixed Operating pressure p1: 20 bar max. Pressure setting p2: 0 to 20 bar Ambient temperature: -10 to +40 C Hysteresis: * < 3 % (lN max, p2 max) Repeatability: * < 1 % (p2 max) Linearity: * See characteristic curve Response sensitivity: * < 1 % (lN max, p2 max) Degree of protection: IP 65 with connector Mounting: Any, preferably vertical Material: Body aluminium alloy Seals NBR (Perbunan)

Ordering Information
3 way proportional pressure control valve, ND 4, pressure setting 0 to 10 bar, port size G 1/4 Type: 4088110.7053.012.00

Alternative Models
With thread connection NPT

Connectors
See data sheet 7503364

* Values referred to 20 C with dither 20% lN, 50 Hz

11/99

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

N/** 6.6.022.01

VP40 ND 4, 6, 8

General Information
Type Nominal diameter Port size Pressure Setting p2 (bar) 0 to 10 0 to 20 0 to 2,1 0 to 10 0 to 7 Max. Operating Pressure p1 (bar) 10 20 7 12 10 Rated Current lN (mA) 0 to 1600 (1800) Drive Electronics pQ11, pQ12, pQ04 see data sheets 7502961, 7503109, 7503188 Weight (kg) 0,8 0,8 1,0 1,0 1,2

4088110.7053.012.00 4088218.7071.012.00 4088200.7053.012.00 4088210.7053.012.00 4088310.7071.012.00

4 4 6 6 8

G 1/8 G 1/8 G 1/4 G 1/4 G 3/8

Proportional Solenoids
Voltage Limiting current IN Rated power PN Resistance R20 Duty cycle 12 V DC 1840 mA 22 W 6,5 3% 100 %

Accessories
Type 0570275 Description Connector Specification DIN 43650 Form A

Drive Electronics pQ11


Data sheet 6.6.030 Type 5980081 5980085 Rated Current (mA) 0 to 2400 0 to 2400 Electrical connection Connector acc. to DIN 43651 2 m Cable Remarks Description Plug-in type amplifier with constant current regulator PDM. Degree of Protection: IP 65. Power supply: 18 to 32 V DC Residual ripple: 10 %. Ambient temperature: 0 to +50 C. Mounting: Any position

Suitable for valves 4088XXX.XXXX

pQ12
Data sheet 6.6.031 Type 5980126 Rated Current (mA) 0 to 2400 Remarks Suitable for valves 4088XXX.XXXX Description Amplifier module with constant current regulator PDM. Degree of Protection: IP 20. Power supply: 18 to 32 V DC Residual ripple: 10 %. Ambient temperature: 0 to +50 C. Mounting: Any position. For attachment on mounting rail acc. to EN 50022

pQ04
Data sheet 7503188 Type 5988020 Rated Current (mA) 0 to 2400 Setpoint Input 0 to 10 V Ramps 4 PID-controller for Remarks closed loop contr. no Suitable for valves 4090XXX, 4088XXX Suitable for valves 4090XXX, 4088XXX Description Digital amplifier module with constant current regulator PDM. Power supply: 18 to 32 V DC Residual ripple: 10 %. Ambient temperature: 0 to +50 C. Weight: 0,4 kg

5988022

0 to 2400

0 to 10 V

yes

Warning
These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products where applicable.

N/** 6.6.022.02

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

11/99

VP40 ND 4, 6, 8

Characteristic curves
Type: 4088110
p2 (bar) p2 = f (I) 10 9 8 7 6 5 4 3 2 1 0 200 400 600 800 1000 1200 1400 1600 10 9 8 7 6 5 4 3 2 1 0
p2 = 10 b ar

p2 (bar) p2 = f (Q) p1 = 10 bar p2 = adjusted at Q=0

p2 = 8 bar

p2 = 6 b ar
p2 =4 b ar

p2 =2

bar
160 320 480 640 800 Q (l/min)

I (mA)

Type: 4088218
p2 (bar) p2 = f (I) 20 18 16 14 12 10 8 6 4 2 0 200 400 600 800 1000 1200 1400 1600 1800 I (mA) 20 18 16 14 12 10 8 6 4 2 0
p2 = 20 ba r

p2 (bar) p2 = f (Q) p1 = 20 bar p2 = adjusted at Q=0

p2 = 18 bar p2 = 16 bar p2 = 14 bar


p2 = 12 bar p2 = 10 bar
p2 =6

p2 = 8 bar
ba

r p2 = 2 ba r
320 640 960 1280 1600 1920 2080 Q (l/min)

Type: 4088200
p2 (bar) p2 = f (I) 2,1 2,0 1,8 1,6 1,4 1,2 1,0 0,8 0,6 0,4 0,2 0 200 400 600 800 1000 1200 1400 1600 I (mA) 0 0,5 1
p2 = 1,5 bar

p2 (bar) p2 = f (Q) 2 p1 = 7 bar p2 = adjusted at Q=0 1,5

p2 = 2 bar

p 2=

p2 =1

bar

0,

ba

r
320 480 640 800 Q (l/min)

160

11/99

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

N/** 6.6.022.03

VP40 ND 4, 6, 8

Type: 4088210
p2 (bar) p2 = f (I) 10 9 8 7 6 5 4 3 2 1 0 200 400 600 800 1000 1200 1400 1600 10 9 8 7 6 5 4 3 2 1 0
p2 = 8 ba
p2 = 6b ar

p2 (bar) p2 = f (Q)
p2 = 10 b

ar

p1 = 12 bar p2 = adjusted at Q=0

p2 =4 p2 =2

ba r

ba

320

640

960

1280

1440

I (mA)

Q (l/min)

Type: 4088310
p2 (bar) p2 = f (I) 7 6 5 4 4 3 3 2 1 2 1 200 400 600 800 1000 1200 1400 1600 0 7 6 5
p2 = 7 ba r p2 =6 bar p2 =5 bar p2 =4 ba p2 r =3 ba p2 r =2 bar p2 =1 ba r

p2 (bar) p2 = f (Q) p1 = 10 bar p2 = adjusted at Q=0

400

800

1200

1600

2000 Q (l/min)

I (mA)

General Dimensions
F M

12

Pg 11

E1

A3

6,5

3
A1 E2 B2 C1

1 2
C2

B1

A2 C3 D

Type 4088110 4088218 4088200 4088210 4088310

A1 1/8 1/4 1/4 1/4 3/8

A2 1/8 1/4 1/4 1/4 3/8

A3 1/8 1/8 1/4 1/8 3/8

B1 23 26,5 30 26,5 36,5

B2 50,5 44,5 50 44,5 67

C1 36 40 43 40 52

C2 36 34 38 34 52

C3 34 34 49 34 50

D 50 50 60 50 70

E1 121 121 117 115 142

E2 62,5 56,5 58,5 56,5 77,5

IF 35 45 35 35 45

H 131 128 127 125 149,5

L 89 94 94 89 104

M 52,5 57 57,5 52,5 67

N 50 50 40 50 55

N/** 6.6.022.04