You are on page 1of 3

Dual-Port DS3 Controller Card

Release 2.0 For use in Axxius 800 Platform


Part Number: 740-0074

Generate new voice and data services and revenues on a single platform while capitalizing on wasted bandwidth
The Dual-Port DS3 Controller Card is a key component of the AxxiusTM 800 Access Integration Platform, delivering a cost-effective, compact solution that supports advanced voice and data services on a single platform, while turning previously wasted bandwidth into new revenues. connects to the Control Panel Interface Card for physical termination of the on-board DS3 circuits and access to the RS-232 and Ethernet management interfaces.

Configuration and remote management functionality


The DS3 Controller has several local and remote management options available. Front-panel LEDs quickly communicate alarm, system, and DS3 line status. The Controller can be configured and managed locally through the RS-232 or Ethernet management connections on the Control Panel Interface Card using a Command Line Interface (CLI). A number of remote management options are available to reduce truck roll costs for most maintenance and troubleshooting activities. The in-band DS0 management channel on the Controller delivers 64 Kbps of remote access to the Axxius 800 without incurring additional facility costs. Alternatively, a separate Ethernet facility can be deployed to support out-of-band SNMP network management. The Controller can also be accessed through the V.34 dial-in modem connection from the Single-Channel POTS Service Card with V.34 Modem.

Combined functionality with full 3/1/0 crossconnect capability


The Axxius 800 with a DS3 Controller replaces backto-back M13 multiplexers and provides 3/1/0 crossconnect capability to groom DS1 and DS0 services. It also offers service providers the ability to provide fractional T1 and DS0 level services in a single platform while continuing to fully utilize the available DS3 bandwidth. In addition, it can operate as a DS3 add/drop multiplexer, delivering T1/FT1 tributaries to remote cell sites or customer locations. With a DS3 Controller, the Axxius 800 supports up to 32 T1 ports. With two DS3 Controllers protection and redundancy is achieved. The DS3 Controller features two DS3 ports with integrated CSUs and a built-in, full, non-blocking 3/1/0 cross-connect matrix. It provides connectivity between the Controllers two DS3 ports and any of the eight Service Card slots. The DS3 Controller also

What makes the Axxius 800 with DS3 Controller Card different:
Consolidates bandwidth delivery, grooming, and management functions of multiple boxes into one 2 RU platform Compact, single-box solution that allows service providers to optimize T1 access facilities and deliver additional revenue-generating services at dramatically lower costs Rescues up to 35% or more of network bandwidth commonly wasted at the cell site or when providing fractional T1 service redistributes residual bandwidth improving network efficiency and maximizing leased lines Extends DCS capabilities to cell sites, POPs and COLOs, enabling previously unused DS0s to be used to deliver revenue-generating services Supports addition of new T1 services with existing T1 circuits

A x x i u s

8 0 0

P o r t

C a p a c i t y

w i t h

D u a l

D S 3

C o n t r o l l e r

DS3 2

ISDN BRI 36

OCU-DP 64

V.35 Nx56/64K 16

10/100Base-TX Ethernet 32

FXO 64

RS-232 T1 ADPCM (Asynch) 32 8

Key features
Supports 3/1/0 grooming for service delivery applications and distributes residual bandwidth to remote cell sites or customer locations Integrated 3/1/0 digital cross-connect for service grooming, restoration, and add/drop functions Provides full, non-blocking 3/1/0 cross-connectivity between the DS3 ports and any of the eight Service Card slots Two DS3 ports and 3/1/0 digital cross-connect deliver bandwidth to the system service slots Operating temperature range -40 F to 149 F (-40 C to 65 C) Enables remote SNMP, or Telnet provisioning, monitoring, and testing of services and network conditions Selectable test loopbacks for quick fault isolation DS3 line redundancy configurable via craft executable command

Te c h n i c a l s p e c i f i c a t i o n s f o r t h e A x x i u s 8 0 0 D u a l - P o r t D S 3 C o n t r o l l e r C a r d
Requirements: Axxius 800 Release 1.0 or higher to support the Dual-Port DS3 Controller Axxius 800 Release 2.0 or higher to support all features listed Product Includes: Built-in, non-blocking 3/1/0 digital cross-connect system Robbed-bit (voice) and clear-channel (data) signaling on the same DS3 Integral dual DS3 ports that support drop-and-insert applications RFC 2496 performance monitoring statistics: 96 15-minute segments (24-hour period) Performance report messages Front-panel LED indicators for DS3 status, major and minor alarms, and Alarm Cut-Off (ACO) status are located on the Control Panel Interface Card Controller support for Quad-Port Terminal Server Router (TSR) Service Card code download through its Ethernet management port Configurations automatically stored in non-volatile memory SNMP agent, supporting MIB objects: - RFC 1213 (MIB-II) - RFC 1659 (V.35) - RFC 1907 (SNMPv2-MIB) - RFC 2011 (IP-MIB) - RFC 2233 (IF-MIB) - RFC 2494 (DS0-MIB) - RFC 2495 (DS1-MIB) - RFC 2496 (DS3-MIB) Management: Local: - RS-232 craft port interface drives up to a 50 ft (15.24 m) cable and provides a Command Line Interface (CLI) using ASCII terminal or PC with terminal emulation software, or modem using XMODEM or PPP sessions Remote: - 10/100Base-TX Ethernet management port provides: Local IP management connectivity RJ-45 connector mounted on the front of the Control Panel Interface Card 10/100Base-TX link LED status indicator IP management over a dedicated DS0 bearer channel - CLI management via the V.34 modem port on the SingleChannel POTS Service Card with V.34 Modem Contains integrated TFTP client for remote download of Controller software upgrades SNMP agent for use with SNMP-based Element Management Systems CLI offers 3 levels of password-controlled security Network DS3 Interface: Line rate: 44.736 Mbps 20 ppm Product Ordering Information Line code: bipolar with three-zero substitution (B3ZS) Framing format: M23 and C Bit parity Inside Sales Representative: Transmit impedance: 75 5%, unbalanced E-mail Transmit jitter attenuation: meets ANSI T1.102 requirements inside-sales@carrieraccess.com Transmit amplitude: meets ANSI T1.102 pulse mask with 0.36 to 0.85 Vp requirements Phone Transmit length (cable): 500 ft (152.4 m) to cross-connect 800-365-2593 Receive sensitivity: -10 dB w/r DSX-3 120 mVp to 900 mVp Fax input range with automatic gain control circuit 303-218-5680 Input range with automatic gain control 0 to 450 ft with no need to use LBO commands 5395 Pearl Parkway DS3 connectors: 4 SMB jacks (SMB-to-BNC adapter cables Boulder, Colorado 80301 available) 3 dB jumpers can be inserted on the Trunk Interface to www.carrieraccess.com attenuate the DS3 TX signal

Te c h n i c a l S p e c i f i c a t i o n s f o r t h e A x x i u s 8 0 0 D u a l - P o r t D S 3 C o n t r o l l e r C a r d
Service Cards Supported: Hardened Dual V.35/.54 Service Card Hardened Low-Speed Interface Protection Card Hardened Order Wire Single-Channel POTS Service Card Hardened Order Wire Single-Channel POTS Service Card with V.34 Modem (modem not hardened) Hardened Quad DS1 ADPCM Service Card Hardened Quad-Port Terminal Server Router (TSR) Service Card Hardened Quad DS1 Service Card 8-Channel FXO Voice Service Card Dual, Quad, and Octal ISDN BRI Service Cards Single and Quad-Port OCU-DP Service Cards Testing and Diagnostics: Supports maintenance signals specified in ANSI T1.404 (Section 7.1) Standard DS3 line and payload loopbacks RFC 2496 performance history Power: 10 W maximum Regulatory Approvals: USA - UL 60950 - FCC Part 15, Class A - Designed to NEBS Level-3 for type 2 and 4 equipment (not certified) Canada - CSA C22.2 No. 60950-00 - ICES-003, Class A Physical: Dimensions: - 3.5 in (H) x 0.75 in (W) x 11.25 in (D) - 8.9 cm (H) x 1.9 cm (W) x 28.6 cm (D) Weight: 10.2 oz (0.29 kg) Environment: Operating temperature: -40 F to 149 F (-40 C to 65 C) Storage temperature range: -40 F to 158 F (-40 C to 70 C) Cooling method is by free air convection Maximum operating altitude: 10,000 ft (3,048 m) Minimum operating altitude: 197 ft (60 m) below sea level Maximum non-operating altitude: 40,000 ft (12,192 m) Relative humidity (non-condensing) range: 0% to 95%

Network Standards: ANSI T1.403 and T1.404 ITU G.703, G.704 Clocking: Loop-timed from any DS1 within the DS3 External from BITS clock input (T1.101, T1.102 Signal Type) Revertive or non-revertive (provisionable) clock switching provides automatic backup to secondary DS3 should the primary DS3 fail Operates as a Stratum 4E device as defined by TelcordiaTM GR-1244-CORE and AT&T TR 62411 Alarms: 3 visible alarm outputs (critical/major/minor) 3 audible alarm outputs (critical/major/minor) 10 alarm inputs (user definable) All alarms are logged in an event log Loss of power triggers minor alarm Generates SNMP traps for alarming

Product Ordering Information Inside Sales Representative: E-mail inside-sales@carrieraccess.com Phone 800-365-2593 Fax 303-218-5680 5395 Pearl Parkway Boulder, Colorado 80301 www.carrieraccess.com
The Carrier Access logo is a registered trademark and Axxius and solve for x are trademarks of Carrier Access Corporation. All other trademarks are the property of their respective companies. All specifications subject to change without notice. Copyright 2003 Carrier Access Corporation. All rights reserved.

027-0136-1300 revision: June 2003