You are on page 1of 2

Synchro Studio 7

Corrections and Changes

Synchro Studio 7 Changes and Correction


Last Update: November 17, 2006 Page vi viii 5-8 Item Detector Phase in Chapter 7 TOC Detector Phase in Chapter 10 TOC Before heading Lane Utilization Factor Figure 7-3 Second paragraph under Figure 7-3. Detector Phase heading Second paragraph under the note Before Switch Phase heading Correction Change to Detector Phases Change to Detector Phases Add a note to See the Supplemental Roundabout documentation in the Trafficware directory (Mult-Lane Roundabouts Supplement.doc). Change the text Detector Phase to Detector Phases. Show the WBT Detector Phases with phase 2 1. Change entire paragraph to Both phase 1 and 2 will be assigned as the Detector Phase. Change to Detector Phases Delete the sentence Only one phase number can be entered for the Detector Phase. Add NTCIP specifies only one Extension phase for a detector. It is possible to have a seonc phase, by sourcing a second detector. Because of the extra steps in the controller setup, avoid using a second detector phase except where absolutely necessary. Change Detector Phase to Detector Phases. Add a note to See the Supplemental Roundabout documentation in the Trafficware directory (Mult-Lane Roundabouts Supplement.doc). Change to Detector Phases Change first sentence to The Detector Phases are the primary phases for a detector. Change Detector Phase to Detector Phases. 11/17/06 11/17/06 11/17/06 11/17.06 Date 11/17/06 11/17/06 4/4/07

7-6 7-6 7-7 7-8 7-8

7-8 7-20

Second note on the page, 2nd sentence After heading Roundabout Settings Detector Phase heading First sentence under Detector Phases Second sentence under Detector Phases Detector Phase, 2nd paragraph New in Version 7 Switch Phase, second paragraph Third Paragraph, DetectPhase1, 2, 3, 4:

11/17/06 4/4/07

10-2 10-2 10-2

11/17/06 11/17/06 11/17/06

10-2

Remove this paragraph. The detector phase can have up to four phases coded. Add sentence at the end The Switch Phase will not be used unless set by the user. Replace sentence with DetectPhase1, DetectPhase2, DetectPhase3, DetectPhase4: Each lane group can have four detector phases associated with them. The detectors for this lane group place a call to

11/17/06

10-2 16-15

11/17/06 11/17/06

Synchro Studio 7

Corrections and Changes

Page

Item

Correction the DetectPhase.

Date

16-15 16-15 20-4 21-12

Fourth and 5 paragraphs

th

Delete the paragraphs about DetectPhase1 and DetectPhase2 Delete Detector calls go to this phase. Add, Not used after Synchro version 731; still can be read, but not written. Change SY7 to SYN and ST7 to SIM Change Detector Phase to Detector Phases. Also change the second sentence of this paragraph from Detector Phase to Detector Phases. Add a note to See the Supplemental Roundabout documentation in the Trafficware directory (Mult-Lane Roundabouts Supplement.doc). Add a note to See the Supplemental Roundabout documentation in the Trafficware directory (Mult-Lane Roundabouts Supplement.doc).

11/17/06

Sixth paragraph 2nd paragraph Detector Settings, 3rd paragraph Before heading Volume Settings Data After heading Roundabout Analysis

4/4/07 11/17/06

21-7

4/4/07

21-9

4/4/07

You might also like