1/8 Solenoid Operated Directional Valves, DSG-01 Series

These are Solenoid Operated Directional Valves of high pressure, high


flow and low pressure drop, the features of which can be materialized
by employing a powerful wet type solenoid and the rational flow
channel design.
High Pressure & High Flow Rate
In comparison to our existing lines, both the pressure and flow of
these valves are much increased.
Max. Operating Pressure: approx. 10 % increased [31.535 MPa
(4570 5080 PSI)]
Terminal Box Type
Max. T-Line Back Pressure: approx. 30 % increased [1621 MPa
(2320 3050 PSI)]
Max. Flow Rate: approx. 60 % increased [63100 L/min (16.64
26.42 U.S.GPM)]
Low Pressure Drop
The pressure drop of these valves is reduced by 10 % from 1.0 to 0.9
MPa (145 to 131 PSI), in comparison to our existing lines*; the valves
effectively reduce the energy consumption of the unit.
{* At Flow Rate: 60 L/min (15.9 U.S.GPM), Spool Type: 3C2 (PA)}
Compact & Small Mass
Despite of high pressure, high flow and low pressure drop, these valve
Plug-in Connector Type
bodies are compact and lightweight with DC double solenoids; the
overall length and mass are reduced from 210 to 205 mm (8.26 to 8.07
inch) and from 2.2 to 1.85 kg (4.85 to 4.08 lbs), respectively.
Shockless type available
In addition to the standard valves for high pressure and high flow, a
shockless type capable of minimizing noise and vibration in piping
during spool changeover is also available.
Stable Operation
Due to the powerful magnetic and spring force of the solenoids, these
valves exhibit a high tolerance to contaminants and especially stable
operation.
IP65-equivalent high dust- and water-proof
These valves demonstrate excellent dust- and water-proof
characteristics, in compliance with I. E. C. Pub. 529. IP65 and JIS C
0920 IP65 (dust- and jet-proof type).
Usable in products of various standards
These standard valves are CE certified for installation in equipment overseas.
UL/CSA certified products are also available.

Specifications
Valve Type

Model Numbers

Max. Flow 2
L/min
(U.S.GPM)

Max. Operating
Pressure
MPa (PSI)

Max. T-Line
Back Pressure
MPa (PSI)

100
(26.4)

35
(5080)

21
(3050)

DSG-01-3C - -70/7090
Standard Type

DSG-01-2D2- -70/7090
DSG-01-2B - -70/7090

Shockless Type

S-DSG-01-3C - -70/7090
S-DSG-01-2B2- -70/7090

Max. Changeover
Frequency
Cycle/min {min1}

Mass
kg
(lbs.)

300
R Type Sol. Only
120

1.85
(4.08)

63
(16.6)

25
(3630)

21
(3050)

120

40
(10.6)

16
(2320)

16
(2320)

300
R Type Sol. Only
120

1.4(3.09)
1.85(4.08)
1.4(3.09)

L-DSG-01-3C - -70/7090
Low Wattage(14W)
Type 1

L-DSG-01-2D2- -70/7090
L-DSG-01-2N - -70/7090
L-DSG-01-2B

- -70/7090

1.85
(4.08)
1.4(3.09)

1. For details of L-DSG-01, please contact us.


2. Maximum flow indicates a ceiling flow depends on the type of spool and operating condition, refer to the List of Spool Functions on pages 347
to 351 for details.

344

DSG-01 Series Solenoid Operated Directional Valves

DIRECTIONAL CONTROLS
Sub-plate
Piping
Size

Japanese Standard "JIS "


Sub-plat e
Model Numbers

Thread
Size

European Design Standard


Sub-plat e
Model Numbers

N.American Design Standard

Thread
Size

Sub-plat e
Model Numbers

Approx.
Mass
kg (lbs.)

Thread
Size

1/8

DSGM-01-31

Rc 1/8

DSGM-01-3180

1/8 BSP. F

DSGM-01-3190

1/8 NPT

0.8 (1.8 )

1/4

DSGM-01X-31

Rc 1/4

DSGM-01X-3180

1/4 BSP. F

DSGM-01X-3190

1/4 NPT

0.8 (1.8 )

3/8

DSGM-01Y-31

Rc 3/8

DSGM-01Y-3190

3/8 NPT

0.8 (1.8 )

Sub-plates are available. Specify the sub-plate model number from the table above.
When sub-plates are not used, the mounting surface should have a good machined finish.

Mounting Bolt
For socket head cap screws in the table below are included.
Descriptions

Soc. Hd. Cap Screw (4 pcs.)

Tightening Torque

Japanese Standard "JIS"


European Design Standard

M5 45 Lg.

N. American Design Standard

No. 10-24 UNC 1-3/4 Lg .

5 - 7 Nm (43 - 60 in. 1bs.)


Applicable to working pressure more than
25 MPa (3630 PSI): 6 - 7 Nm (52 - 60 in. 1bs.)

Valve Type

Coil
Type

Electric source

Frequency
(Hz)
50

A100

Standard
Type

AC

A120

A200

A240

Shockless
Type
DC (K Series )
AC DC Rectified (R )

D12
D24
D48
R100
R200

60
50
60
50
60
50
60

50/60

Voltage (V)
Source Ratin g
100
100
110
120
200
200
220
240
12
24
48
100
200

Serviceable Range
80 - 110
90 - 120
96 - 132
108 - 144
160 - 220
180 - 240
192
216
10.8
21.6
43.2
90
180

264
288
13.2
26.4
52.8
110
220

Current & Power at Rated Voltage


Inrush (A) 2 Holding (A)
Power (W)
2.42
0.51
2.14
0.37
2.35
0.44
2.02
0.42
1.78
0.31
1.21
0.25
1.07
0.19
1.18
0.22
1.01
0.21
0.89
0.15
2.45
1.23
29
0.61
0.33
29
0.16

DSG-01 Series Solenoid


Operated Directional Valves

Solenoid Ratings

1. AC solenoid is not available in shockless type.


R type models with built-in current rectifier is recommended for shockless operation with AC power.
2. Inrush current in the above table show rms values at maximum stroke.
3. There are more coil types other than the above. For details, please make inquiries.
The coil type numbers in the shaded column are handled as opotinal extras.
In case these coils are required to be chosen, please confirm the time of
delivery with us before ordering.

Options
Push Button with Lock Nut
Can be used for manual changeover of spool. The push button
can be locked in the pressed condition.

Lock Nut

SOL b

Push Button

Plug-in Connector with Solenoid Indicator Light


These are the indicator light incorporated plug-in connector
type solenoids. Energisation or de-energisation of the solenoid
can be easily identified with the incorporated indicator light.

Plug-in Connector
With Indicator Light

SOL b

DSG-01 Series Solenoid Operated Directional Valves

345

Model Number Designation


FSpecial
Seals

SShockless
Type

- 01

DSG
Series
Number

Valve
Size

-2
Number
of Valve
Positions

3:
Three
Positions

B
SpoolSpring
Arrangement

C:
Spring
Centred

2
Spool
Type

-D24

Special Two
Position Valve
Omit if not
required

2, 3
4, 40
60, 9
10, 11
12

Coil
Type

-C
Manual
Override

-N
Electrical
Conduit
Connection

-70

-L

Design
Number

Models with
Reverse Mtg. of
Solenoid
Omit if not
required

None:
Japanese
Std. "JIS"

AC:
A100
A120
A200
A240

Design
Standard

None:
Manual
Override
Pin

None:
Terminal
Box Type

90:
N.American
Design Std.

DC:
None:
Standard
Type
F:
For Phosphate
Ester Type
Fluids
(Omit if not
required

D:
No-Spring
Detented
DSG:
Solenoid
Operated
Directional
Valve

01

2:
Two
Positions

R:

B:
Spring
Offset

S:
Shockless
Type

D12
D24
D48

3:
Three
Positions

C:
Spring
Centred

2:
Two
Positions

B:
Spring
Offset

2
3
8

2
4

A
B

1
1

(AC
DC)
R100
R200

DC:
D12
D24
D48

C:
Push
Button
and
Lock Nut
(Option)

70
N:
Plug-in
Connector
Type
2

N1 :
Plug-in
Connector
Type
with
Indicator
Light
(Option)

R:
(AC
DC)
R100
R200

1. In case of the special two position valve, please refer to page 352 for details.
2. N1 is not available for R type solenoids.

In the table above, the symbols or numbers highlighted with shade represent the optional
extras. The valves with model number having such optional extras are handles as options,
therefore, please confirm the time of delivery with us before ordering.

346

DSG-01 Series Solenoid Operated Directional Valves

None:
Japanese
Std. "JIS"
and
European
Design
Std.

90:
N. American
Design
Std.

DIRECTIONAL CONTROLS
List of Standard Models and The Maximum Flow
Models with AC Solenoids: DSG-01-

-A
L /min

[Port "B" Blocked]


Model
Numbers

Graphic
Symbols

10
DSG013C2

b
PT
AB

DSG013C3

b
PT
AB

DSG013C4

DSG013C40

b
PT
AB

Spring Centred

Working Pressure MPa

A B

Three Positions

b
PT
AB

DSG013C60

a
PT

16

25

31. 5

100

100

100

Working Pressure MPa

Working Pressure MPa

35

10

16

25

1004310041 8021
5738 5331 2917
1008010080100801007710077 7046 7046 7046
9063 9063 9063 9063 9063 4530 4530 4530
90 9022 3518 10038 7628 6715
90
90
9026 4314 3011 5031 3820 2010
85 8040 8022 8540 8535 8524
85
85
80
80 8030 6315 2510 7026 5024 3216
4323 4323 4223 4223 4223 5432 5432 5232
4023 4023 3823 3623 3523 4830 4730 4730
100

[Port "A" Blocked]

100

31. 5
6017
1910
7046
4530
5710
167
6016
2213
5232
4730

35

10

16

25

3815 1004310041 8021


139 5738 5331 2917
7046 7046 7046 7046
4530 4530 4530 4530
357 10038 7628 6715
125 5031 3820 2010
5512 8540 8535 8524
1810 7026 5024 3216
5232 5432 5432 5232
4730 4830 4730 4730

31. 5

35

6017
1910
7046
4530
5710
167
6016
2213
5232
4730

3815
139
7046
4530
357
125
5512
1810
5232
4730

10

AB

DSG013C9

100

100

100

100

100

100

100

100

20

10

15

10

20

10

15

PT
AB

DSG013C10

a
PT
AB

DSG013C11

a
PT
AB

DSG013C12

No-Spring
Detented

DSG012D2

80

80

80

80

80

45

6213
1510
6027
3518
6213
1510

5045 5042 4540 4540

4521 4516 3813


AB

50

45

PT

5045 5042 4540 4540

3618 2813 2212


AB

Spring Offset

Two Positions

PT

100 100631003310027100501003710020 7816 6213 100501003710020 7816


10070 8020 7020 4019 10037 5525 2914 2011 1510 10037 5525 2914 2011
10065 8552 7245 6534
5
13
10
20
23
100
100
100
100
7050 5740 5025 4319
100 100631003310027100501003710020 7816 6213 100501003710020 7816
10070 8020 7020 4019 10037 5525 2914 2011 1510 10037 5525 2914 2011

DSG012B2

85

85

85

85

85

20

16

16

15

13

70

70

70

70

70

50

50

50

50

50

26

17

13

11

10

PT
AB

DSG012B3
PT
AB

DSG012B8
PT

8563
8530
8070
7048
8050
3520

8050
6033
8070
7048
7040
2315

6340
5028
8070
7048
6020
158

4432
4028
8070
7048
4510
105

E
DSG-01 Series Solenoid
Operated Directional Valves

Spool-Spring Arrangement

No. of Valve Positions

Max. Flow

4432
4028
8070
7048
3010
75

Notes: 1. The relation between the maximum flow in the table above and the frequency/voltage (within the serviceable voltage) is as shown below.
( Example )

50 Hz, At minimum serviceable voltage


(80% of rated voltage)

50 Hz, At rated voltage

The maximum flow rate is constant


regardless of 50 Hz or 60 Hz and of
any voltage variants within the
serviceable voltage
60 Hz, At rated voltage
2. For the maximum flow rate in P T of the valves with a

100

100 (43)
57 (38)
60 Hz, At minimum serviceable voltage
(90% of rated voltage)

mark, please see page 351.

The valve models with a mark are handled as


Options. If you choose such valves, check the time
of delivery beforehand.

DSG-01 Series Solenoid Operated Directional Valves

347

List of Standard Models and The Maximum Flow


Models with DC or R Type Solenoids: DSG-01-

-D /R
L /mi

Spool-Spring Arrangement

No. of Valve Positions

Max. Flow

[Port "B" Blocked]


Model
Numbers

Graphic
Symbols

Working Pressure MPa

10

16

25

31. 5

35

100

100

100

100

100

100
80

100
80

90

90

85

85

50
41

50
41

100
80
90
42
65
45
50
41

100
80
50
26
40
30
50
41

100

100

100

85

85

100

AB
a
PT
a

Spring Centred

Three Positions

DSG013C60

a
PT

Working Pressure MPa

35

10

16

25

31. 5

35

100
80
38
20
33
26
50
41

100
55
78
70
100
62
85
65
66
58

45
35
78
70
58
48
52
36
66
58

28
23
78
70
38
30
30
25
66
58

25
19
78
70
31
25
26
21
66
58

22
17
75
70
29
23
24
19
66
58

100
55
78
70
100
62
85
65
66
58

45
35
78
70
58
48
52
36
66
58

28
23
78
70
38
30
30
25
66
58

25
19
78
70
31
25
26
21
66
58

22
17
75
70
29
23
24
19
66
58

100

100

20

15

10

10

20

15

10

10

85
35

80
23

40
20

100
74

56
43

36
28

28
20

24
19

100

100

100

100

23

20

13

10

85

85

85
35

80
23

40
20

100
74

56
43

36
28

28
20

24
19

100
74
100
85
100
74

56
43
60
46
56
43

36
28
40
32
36
28

28
20
36
28
28
20

24
19
32
24
24
19

75

75

75

75

75

40

30

27

50

50

45

45

45

42

40

40

31
23
75
65
35
30

24
19
75
65
23
17

22
18
75
65
19
13

22
18
75
65
17
12

PT
AB

31. 5

AB
a

25

PT

DSG013C40

16

AB

DSG013C4

10

PT

DSG013C3

Working Pressure MPa

A B

DSG013C2

[Port "A" Blocked]

AB

DSG013C9

a
PT
AB

DSG013C10

a
PT
AB

DSG013C11

a
PT
AB

DSG013C12

No-Spring
Detented

DSG012D2

AB

45

50

45

PT

30

25

22

16

16

15

13

50

50

50

50

50

26

17

13

11

10

70

70

70

70

70

80

80

80

80

80

20

70

70

70

70

70

AB

Spring Offset

Two Positions

PT

DSG012B2
PT
AB

DSG012B3
PT
AB

DSG012B8

b
PT

46
32
75
65
53
35

Notes: 1. The relation between the maximum flow in the table above and the voltage (within the serviceable voltage) is as shown be low.
( Example )

The maximum flow rate is constant


regardless of any voltage variants
within the serviceable voltage

100

2. For the maximum flow rate in P T of the valves with a

100
55

At rated voltage
[after temperature rise and saturated]
At minimum serviceable voltage
(90% of rated voltage)
[after temperature rise and saturated]

mark, please see page 351.

The valve models with a mark are handled as


Options. If you choose suce valves, check the time
of delivery beforehand.

348

DSG-01 Series Solenoid Operated Directional Valves

DIRECTIONAL CONTROLS
List of Standard Models and The Maximum Flow
Models with AC Solenoids: DSG-01-

-A

Spool-Spring Arrangement

No. of Valve Positions

Max. Flow

U.S.GPM

[Port "B" Blocked]


Model
Numbers

Graphic
Symbols

Working Pressure PSI

[Port "A" Blocked]

Working Pressure PSI

Working Pressure PSI

1450 2320 3630 4570 5080 1450 2320 3630 4570 5080 1450 2320 3630 4570 5080

DSG013C2

b
PT
AB

DSG013C3

b
PT
AB

DSG013C4

DSG013C40

Spring Centred

Three Positions

PT
AB
b
PT
AB

DSG013C60

a
PT

26.4(11.4) 26.4(10.8) 21.1(5.6) 15.9(4.5) 10.0(4.0) 26.4(11.4) 26.4(10.8) 21.1(5.6) 15.9(4.5) 10.0(4.0)
15.1(10.0) 14.0(8.2) 7.7(4.5) 5.0(2.6) 3.4(2.4) 15.1(10.0) 14.0(8.2) 7.7(4.5) 5.0(2.6) 3.4(2.4)
26.4(21.1) 26.4(21.1) 26.4(21.1) 26.4(21.1) 26.4(21.1) 18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2)
23.8(16.6) 23.8(16.6) 23.8(16.6) 23.8(16.6) 23.8(16.6) 11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9)
23.8 23.8(5.8) 9.2(4.8) 26.4(10.0) 20.1(17.4) 17.7(4.0) 15.1(2.6) 9.2(1.8) 26.4(10.0) 20.1(7.4) 17.7(4.0) 15.1(2.6) 9.2(1.8)
23.8
23.8
23.8(6.9) 11.4(3.7) 7.9(2.9) 13.2(8.2) 10.0(5.3) 5.3(2.6) 4.2(1.9) 3.2(1.3) 13.2(8.2) 10.0(5.3) 5.3(2.6) 4.2(1.9) 3.2(1.3)
22.5
22.5
22.5 21.1(10.6) 21.1(5.8) 22.5(10.6) 22.5(9.3) 22.5(6.3) 15.9(4.2) 14.5(3.2) 22.5(10.6) 22.5(9.3) 22.5(6.3) 15.9(4.2) 14.5(3.2)
21.1
21.1 21.1(7.9) 16.6(4.0) 6.6(2.4) 18.5(6.9) 13.2(6.3) 8.5(4.2) 5.8(3.4) 4.8(2.6) 18.5(6.9) 13.2(6.3) 8.5(4.2) 5.8(3.4) 4.8(2.6)
11.4(6.1) 11.4(6.1) 11.1(6.1) 11.1(6.1) 11.1(6.1) 14.2(8.4) 14.2(8.4) 13.7(8.4) 13.7(8.4) 13.7(8.4) 14.2(8.4) 14.2(8.4) 13.7(8.4) 13.7(8.4) 13.7(8.4)
10.6(6.1) 10.6(6.1) 10.0(6.1) 9.5(6.1) 9.2(6.1) 12.7(7.9) 12.4(7.9) 12.4(7.9) 12.4(7.9) 12.4(7.9) 12.7(7.9) 12.4(7.9) 12.4(7.9) 12.4(7.9) 12.4(7.9)
26.4

26.4

26.4

26.4

26.4

AB

DSG013C9

26.4

26.4

26.4

26.4

26.4

26.4

5.3

4.0

2.6

2.6

2.1

5.3

4.0

2.6

2.6

2.1

PT
AB

DSG013C10

a
PT
AB

DSG013C11

b
PT
AB

DSG013C12

No-Spring
Detented

DSG012D2

21.1

21.1

21.1

21.1

21.1

11.9

11.9

16.4(3.4)
4.0(2.6)
15.9(7.1)
9.2(4.8)
16.4(3.4)
4.0(2.6)

13.2(11.9) 13.2(11.1) 11.9(10.6) 11.9(10.6)

11.9(5.6) 11.9(4.2) 10.0(3.4)


AB

13.2

PT

9.5(4.8) 7.4(3.4) 5.8(3.2)


AB

Spring Offset

Two Positions

PT

26.4 26.4(16.6) 26.4(8.7) 26.4(7.1) 26.4(13.2) 26.4(9.8) 26.4(5.3) 20.6(4.2) 16.4(3.4) 26.4(13.2) 26.4(9.8) 26.4(5.3) 20.6(4.2)
26.4(18.5) 21.1(5.3) 18.5(5.3) 10.6(5.0) 26.4(9.8) 14.5(6.6) 7.7(3.7) 5.3(2.9) 4.0(2.6) 26.4(9.8) 14.5(6.6) 7.7(3.7) 5.3(2.9)
26.4(17.2) 22.5(13.7) 19.0(13.7) 17.2(9.0)
26.4
26.4
26.4
26.4
26.4
6.1
5.3
3.4
2.6
1.3
18.5(13.2) 15.1(10.6) 13.2(6.6) 11.4(5.0)
26.4 26.4(16.6) 26.4(8.7) 26.4(7.1) 26.4(13.2) 26.4(9.8) 26.4(5.3) 20.6(4.2) 16.4(3.4) 26.4(13.2) 26.4(9.8) 26.4(5.3) 20.6(4.2)
26.4
26.4(18.5) 21.1(5.3) 18.5(5.3) 10.6(5.0) 26.4(9.8) 14.5(6.6) 7.7(3.7) 5.3(2.9) 4.0(2.6) 26.4(9.8) 14.5(6.6) 7.7(3.7) 5.3(2.9)

DSG012B2

22.5

22.5

22.5

22.5

22.5

5.3

4.2

4.2

4.0

18.5

18.5

18.5

18.5

18.5

13.2

13.2

13.2

13.2

6.9

4.5

3.4

2.9

PT
AB

DSG012B3
PT
AB

DSG012B8
PT

13.2(11.9) 13.2(11.1) 11.9(10.6) 11.9(10.6)

E
DSG-01 Series Solenoid
Operated Directional Valves

A B

22.5(16.6) 21.1(13.2) 16.6(10.6) 11.6(8.5) 11.6(8.5)


22.5(7.9) 15.9(8.7) 13.2(7.4) 10.6(7.4) 10.6(7.4)
21.1(18.5) 21.1(18.5) 21.1(18.5) 21.1(18.5) 21.1(18.5)
13.2
18.5(12.7) 18.5(12.7) 18.5(12.7) 18.5(12.7) 18.5(12.7)
21.1(13.2) 18.5(10.6) 15.9(5.3) 11.9(2.6) 7.9(2.6)
2.6
9.2(5.3) 6.1(4.0) 4.0(2.1) 2.6(1.3) 1.9(1.3)
3.4

Notes: 1. The relation between the maximum flow in the table above and the frequency/voltage (within the serviceable voltage) is as shown below.
( Example )

50 Hz, At minimum serviceable voltage


(80% of rated voltage)

50 Hz, At rated voltage

The maximum flow rate is constant


regardless of 50 Hz or 60 Hz and of
any voltage variants within the
serviceable voltage
60 Hz, At rated voltage
2. For the maximum flow rate in P T of the valves with a

26.4

26.4(11.4)
15.1(10.0)
60 Hz, At minimum serviceable voltage
(90% of rated voltage)

mark, please see page 351.

The valve models with a mark are handled as


Options. If you choose such valves, check the time
of delivery beforehand.

DSG-01 Series Solenoid Operated Directional Valves

349

List of Standard Models and The Maximum Flow


Models with DC or R Type Solenoids: DSG-01-

-D /R

Spool-Spring Arrangement

No. of Valve Positions

Max. Flow

U.S.GPM

[Port "B" Blocked]


Model
Numbers

Graphic
Symbols

Working Pressure PSI

[Port "A" Blocked]

Working Pressure PSI

Working Pressure PSI

1450 2320 3630 4570 5080 1450 2320 3630 4570 5080 1450 2320 3630 4570 5080
A B

DSG013C2

26.4

26.4

26.4

26.4

26.4

PT
AB

DSG013C3

b
PT
AB

DSG013C4

Spring Centred

Three Positions

PT
AB

DSG013C40

b
PT
AB

DSG013C60

a
PT

26.4 26.4 26.4 26.4 26.4


21.1 21.1 21.1 21.1 21.1
23.8 13.2 10.0
23.8 23.8
5.3
11.1 6.9
17.2 10.6 8.7
22.5 22.5
11.9 7.9
6.9
13.3 13.3 13.3 13.3 13.3
10.8 10.8 10.8 10.8 10.8

26.4
14.5
20.6
18.5
26.4
16.4
22.5
17.2
17.4
15.3

11.9
9.3
20.6
18.5
15.3
12.7
13.7
9.5
17.4
15.3

7.4
6.1
20.6
18.5
10.0
7.9
7.9
6.6
17.4
15.3

6.6
5.0
20.6
18.5
8.2
6.6
6.9
5.6
17.4
15.3

5.8 26.4
14.5
4.5
19.8 20.6
18.5 18.5
7.7 26.4
6.1 16.4
6.3 22.5
5.0 17.2
17.4 17.4
15.3 15.3

11.9
9.3
20.6
18.5
15.3
12.7
13.7
9.5
17.4
15.3

7.4
6.1
20.6
18.5
10.0
7.9
7.9
6.6
17.4
15.3

6.6
5.0
20.6
18.5
8.2
6.6
6.9
5.6
17.4
15.3

5.8
4.5
19.8
18.5
7.7
6.1
6.3
5.0
17.4
15.3

AB

DSG013C9

26.4

26.4 26.4

26.4

26.4

5.3

4.0

2.6

2.6

2.1

5.3

4.0

2.6

2.6

2.1

22.5

22.5

22.5
9.2

21.1
6.1

10.6
5.3

26.4
19.6

14.8
11.4

9.5
7.4

7.4
5.3

6.3
5.0

26.4

26.4 26.4

26.4

26.4

6.1

5.3

3.4

2.6

1.3

22.5

22.5

22.5
9.2

21.1
6.1

10.6 26.4
5.3 19.6

14.8
11.4

9.5
7.4

7.4
5.3

6.3
5.0

26.4
19.6
26.4
22.5
26.4
19.6

14.8
11.4
15.9
12.2
14.8
11.4

9.5
7.4
10.6
8.5
9.5
7.4

7.4
5.3
9.5
7.4
7.4
5.3

6.3
5.0
8.5
6.3
6.3
5.0

19.8

19.8

19.8

19.8

19.8

10.6

7.9

7.1

13.2

13.2

11.9

11.9

13.2

11.1

10.6

10.6

8.2
6.1
19.8
17.2
9.2
7.9

6.3
5.0
19.8
17.2
6.1
4.5

5.8
4.8
19.8
17.2
5.0
3.4

5.8
4.8
19.8
17.2
4.5
3.2

PT
AB

DSG013C10

a
PT
AB

DSG013C11

a
PT
AB

DSG013C12

No-Spring
Detented

DSG012D2

AB

11.9

13.2

11.9

PT

7.9

6.6

5.8

4.2

4.2

4.0

3.4

13.2

13.2

13.2

13.2

13.2

6.9

4.5

3.4

2.9

2.6

18.5

18.5

18.5

18.5

18.5

21.1

21.1

21.1

21.1

21.1

5.3

18.5

18.5

18.5

18.5

18.5

AB

Spring Offset

Two Positions

PT

DSG012B2
PT
AB

DSG012B3
PT
AB

DSG012B8

b
PT

12.2
8.5
19.8
17.2
14.0
9.3

Notes: 1. The relation between the maximum flow in the table above and the voltage (within the serviceable voltage) is as shown be low.
( Example )

The maximum flow rate is constant


regardless of any voltage variants
within the serviceable voltage

26.4

2. For the maximum flow rate in P T of the valves with a

26.4
14.5

At rated voltage
[after temperature rise and saturated]
At minimum serviceable voltage
(90% of rated voltage)
[after temperature rise and saturated]

mark, please see page 351.

The valve models with a mark are handled as


Options. If you choose suce valves, check the time
of delivery beforehand.

350

DSG-01 Series Solenoid Operated Directional Valves

DIRECTIONAL CONTROLS
Maximum Flow of Centre By-Pass
In valve type 3C60, in case where the actuator is put on in between the cylinder ports A and B as illustrated below and
where the actuator moves and suspended at its stroke end and where the valve is then shifted to the neutral position in
the suspended state of the actuator, the maximum flow rates available are those as shown as the table below regardless
of any voltage in the range of serviceable valtage.

Max. Flow

Graphic
Symbol

Mode Numbers

10 MPa
16 MPa
25 MPa
31.5 MPa
35 MPa
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI) (5080 PSI)

AB

55
(14.5)

DSG-01-3C60-A /D /R

L/min (U.S.GPM)

PT

44
(11.6)

30
(7.9)

26
(6.9)

22
(5.8)

E
List of Shockless Models and The Maximum Flow
-D /R
Max. Flow

L/min (U.S.GPM)

[Port "B" Blocked]


No. of
Valve
Positions

Spool-Spring
Arrangement

Graphic
Symbol

Model Numbers

Working Pressure
MPa (PSI)
10
(1450)

16
(2320)

25
(3630)

63
(16.6)

63
(16.6)

40
(10.6)

60
(15.9)

50
(13.2)
40
(10.6)
45
(11.9)
40
(10.6)

40
(10.6)
20
(5.3)
45
(11.9)
40
(10.6)

A B

S-DSG-01-3C2
Three
Positions

a
PT

Spring
Centred

AB

S-DSG-01-3C4

a
PT

Two
Positions

Spring
Offset

AB

S-DSG-01-3B2

b
PT

50
(13.2)
45
(11.9)

[Port "A" Blocked]

Working Pressure
MPa (PSI)
10
16
25
(1450) (2320) (3630)

Working Pressure
MPa (PSI)
10
16
25
(1450) (2320) (3630)

40
(10.6)
32
(8.5)
40
(10.6)
32
(8.45)

32
(8.5)
20
(5.3)
32
(8.5)
16
(4.23)

25
(6.6)
16
(4.23)
16
(4.2)
12
(3.17)

40
(10.6)
32
(8.5)
40
(10.6)
32
(8.45)

32
(8.5)
20
(5.3)
32
(8.5)
16
(4.23)

25
(6.6)
16
(4.23)
16
(4.2)
12
(3.17)

30
(7.9)

30
(7.9)

30
(7.9)

60
(15.9)

40
(10.6)

40
(10.6)

DSG-01 Series Solenoid


Operated Directional Valves

Models with DC or R Type Solenoids: S-DSG-01-

Notes: 1. The relation between the maximum flow in the table above and the voltage (within the serviceable voltage) is as shown be low.
L/min

( Example )

The maximum flow rate is constant


regardless of any voltage variants
within the serviceable voltage

60
(15.9)

50
(13.2)
40
(10.6)

At rated voltage
[after temperature rise and saturated]
At minimum serviceable voltage
(90% of rated voltage)
[after temperature rise and saturated]

U.S.GPM

DSG-01 Series Solenoid Operated Directional Valves

351

Reverse Mounting of Solenoid.


In spring offset type, it is a standard configuration that the solenoid is mounted onto the valve in the SOL b position
(side). However, in this particular spool-spring arrangement, the mounting of the solenoid onto the valve in the reverse
position -SOL a side- is also available. The graphic symbol for this reverse mounting is as shown below.
As for the valve type 2B A and 2B B, please refer to the explanation under the heading of "Valves Using Neutral
Position and Side Position" given below.
A

SOL b

SOL a

Standard Mtg. of Solenoid

Reverse Mtg. of Solenoid

Valves Using Neutral Position and Side Position. (Special Two position Valve)
Besides the use of the standard 2-position valves aforementioned in the "List of Standard Models and Maximum Flow",
the 3-position valves also can be used as the 2-position valves using the two of their three positions. In this case, there
are two kinds of the valve available. One is the valve using the neutral position and SOL a position (2B A) and another
is the valve using the neutral position and SOL b position (2B B) .
(Example) In case of Spool Type "2"
Neutral Position
SOL. a Energised
Position

SOL. b Energised
Position
A

B
b

a
P

2B2A

2B2B

b
"A": Use of Neutral and
SOL. a Energised
Position (2B2A)

"B": Use of Neutral and


SOL. b Energised
Position (2B2B)

Graphic SymbolsG
Model Numbers

Standard
Mtg. Type
A

A
b

DSG-01-2B2A

Reverse
Mtg. Type

DSG-01-2B A
T

raphic Symbols
Model Numbers

Standard
Mtg. Type
AB

DSG-01-2B B

a
P

b
P

DSG-01-2B2B
DSG-01-2B3B
DSG-01-2B4B
DSG-01-2B60B
DSG-01-2B10B

In the above table, the graphic symbols in mounting


type highlighted with shade are optional extra,
therefore, please confirm the time of delivery with
us before ordering.

352

Reverse
Mtg. Type

DSG-01 Series Solenoid Operated Directional Valves

DIRECTIONAL CONTROLS
Typical Changeover Time
Changeover time varies according to oil viscosity, spool type and hydraulic circuit.
Standard Type (Without Shockless Function)
[Result of Measurement]

[Test Conditions ]
Pressure:
Flow Rate:
Viscosity:
Voltage:

16 MPa (2320 PSI)


31.5 L /min (8.3 U.S.GPM)
35 mm 2 /s (164 SSU)
100 %V
(After coil temprature rises and saturated)

ON

Solenoid

OF F

O FF
0

Spool Shift

Max.
T2

Type

Model Numbers

Standard
Type

DSG-01-3C2- A
DSG-01-3C2- D
DSG-01-3C2- R

Time ms
T1

T2

15
48
50

23
19
100

Shockless Type
[Reaults of Measurement]

[Test Circuit and Conditions]


Accelmeter

OF F

ON
SOL a

Speed

G1
a

G2

Acceleration (G)
Load

Pressure (Ps)
Ps
T1

Setting Pressure (Ps): 7 MPa (1020 PSI)


Load (W): 1000 kg (2205 1bs.)
Speed: 8 m/min (26.2 ft./min)
Viscosity: 35 mm 2 /s (164 SSU )

Type

T2

Time

Model Nmbers

Time Acceleratio n
ms
m/s2 (G)
T1 T2
G1
G2

Shockles s
Type

S-DSG-01-3C2- D

70 30

12
(1.2 )

7
(0.7 )

Standard
Type

DSG-01-3C2- D

35 25

18
(1.8 )

15
(1.5 )

DSG-01 Series Solenoid Operated Directional Valves

E
DSG-01 Series Solenoid
Operated Directional Valves

T1

353

Pressure Drop
Pressure drop curves based on viscosity of 35 mm2 /s (164 SSU) and specific gravity of 0.850.

Standard Type: DSG-01


PSI
600

MPa
4

Model Numbers

Pressure Drop P

500

12

80

16

20

DSG-01-3C3

DSG-01-3C60

DSG-01-3C9

DSG-01-3C10

DSG-01-3C11

DSG-01-3C12

DSG-01-2D2

100 L/min

DSG-01-2B2

U.S.GPM

DSG-01-2B3

DSG-01-2B8

60

DSG-01-3C40

100

40

200

20

A T

DSG-01-3C4

P B

B T

DSG-01-3C2

400

300

Pressure Drop Curve Number

P A

24

Flow Rate

Shockless Type: S-DSG-01


PSI
180

MPa
1.2

160

120

80

0.8
0.6

Pressure Drop Curve Number

P A

B T

P B

A T

S-DSG-01-3C2

S-DSG-01-3C4

S-DSG-01-2B2

1.0

P
Pressure Drop

Model Numbers

0.4
40
0.2
0

10
0

20
4

30
6

40
10

50
12

14

60

L/min

16

U.S.GPM

Flow Rate

For any other viscosity, multiply the factors in the table below.
Viscosity

mm 2/s 15

Factor

SSU

77

40

50

60

70

80

90

100

20

30

98

141 186 232 278 324 371 417 464

0.81 0.87 0.96 1.03 1.09 1.14 1.19 1.23 1.27 1.30

For any other specific gravity (G'), the pressure drop ( P') may be
obtained from the formula below.
P' = P (G'/0.850)

354

DSG-01 Series Solenoid Operated Directional Valves

P T
2

DIRECTIONAL CONTROLS
Mounting surface: ISO 4401-AB-03-4-A

TERMINAL BOX TYPE


Models with AC Solenoids

Single Solenoid: Spring Offset


DSG-01-2B -A -70/7090

Double Solenoid: Spring Centred & No-Spring Detented


3C -A -70/7090
DSG-01- 2D2
Solenoid Indicator Light
(For Sol a)

145.7
(5.74)

Pressure Port "P"


Cylinder Port "A"
76.7
(3.02)

142.2
(5.60)

Solenoid Indicator Light


(For Sol b)

196.4
(7.73)

95
(3.74)

26
(1.02)

50.7
(2.00)

For other dimensions, refer to "spring Centred and


No-Spring Detented" models.
Solenoid being mounted in the reverse position
SOL a side is also available.

46
(1.81)

A100

SOL a

SOL b

13.5
(.53)
70
(2.76)

38
(1.50)

Mounting Surface
(O-Rings Furnished)

Space Needed to Remove


Solenoid-Each End
45.5
Electrical Conduit Connection
"C " Thd. (Both Ends)
(1.79)

Lock Nut
Tightening Torque:
10.3-11.3 Nm (91-100 IN.lbs.)

33
(1.30)

23.5 47(1.85)
(.93)
88.8
(3.50)

Tank Port "T"

T
B

A
P

27
(1.06)
Manual Actuator-Both Ends
6(.24) Dia.

3(.12) Dia.
5(.20) Deep
VIEW ARROW X

X
Model Numbers

"C " Thd.

DSG-01-

-A -70

DSG-01-

-A -7090 1/2 NPT

G 1/2

Locating pin can be fitted to this hole to conform with


ISO4401-03-02-94. However, locating pin is not provided
to standard design valve. When ordering valve with a
locating pin, please consult Yuken.

DSG-01 Series Solenoid


Operated Directional Valves

Cylinder Port "B"

SOL b

31.75
(1.25)

40.5
(1.59)

31 0.75
(1.22) (.03)
32.5
(1.28)

5.5(.22) Dia. Through


9.5(.37) C' Bore
4 Places

DIMENSIONS IN
MILLIMETRES (INCHES)

Models with DC Solenoids: (S-)DSG-01-D -70/7090


Models with R Type Solenoids: (S-)DSG-01-R -70/7090
Spring Centred
No-Spring Detented
Spring Offset

Space Needed to Remove


Solenoid-Each End
50
(1.97)

204.4(8.05)
149.7
(5.89)

80.7
(3.16)

D24

SOLa

SOL b

D
3

Double Solenoid
Models Only

Spring Offset Type 146.2


(5.76)

For other dimensions, refer to models with AC solenoids.

DSG-01 Series Solenoid Operated Directional Valves

355

Sub-plate : DSGM-01/01X/01Y-31/3180/3190

14.2
(.56)

"C" Thd.
4 Places

DSGM-01-31

Piping Size
"C" Thd.
Rc 1/8

DSGM-01-3180

1/8 BSP.F

DSGM-01-3190

1/8 NPT

DSGM-01X-31

Rc 1/4

"D" Thd.

"E"
mm(IN.)

M5

10 (.39)

No.10-24 UNC

12 (.47)

M5

10 (.39)

DSGM-01X-3180

1/4 BSP.F

DSGM-01X-3190

1/4 NPT

No.10-24 UNC

12 (.47)

Rc 3/8

M5

10 (.39)

3/8 NPT

No. 10-24 UNC

12 (.47)

DSGM-01Y-31
DSGM-01Y-3190

T
11
(.43)

7 (.28) Dia. Through


7
(.28) 11 (.43) Dia. Spotface
2 Places

DSG-01 Series Solenoid Operated Directional Valves

37
(1.46)
24
(.94)

25.8
(1.02)
31
(1.22)
31.75
(1.25)
48
(1.89)
63
(2.48)

Sub-plate
Model Numbers

356

16
(.63)
15
(.59)

8.5
(.33)
7.5
(.30)

12.7(.50)

5.2
(.20)
71
(2.80)
85
(3.35)

32
(1.26)

"D" Thd. "E" Deep


4 Places

0.75
(.03)
15.5
(.61)

7 (.28) Dia.
4 Places

40.5
(1.59)
30.2
(1.19)
21.5
(.85)

DIMENSIONS IN
MILLIMETRES (INCHES)

12.5
(.49)
35.5
(1.40)
58.5
(2.30)

DIRECTIONAL CONTROLS
PLUG-IN CONNECTOR TYPE (N)
PLUG-IN CONNECTOR WITH INDICATOR LIGHT (N1)

DIMENSIONS IN
MILLIMETRES (INCHES)

-A - N -70/7090
N1
Models with DC Solenoids: (S-)DSG-01-D - N -70/7090
N1
Models with R Solenoids: (S-)DSG-01-R -N-70/7090
Models with AC Solenoids: DSG-01-

SOL b

A100

Double Solenoid
Models Only

23.5
(.93)

SOLa

Lock Nut
Tightening Torque:
10.3 - 11.3 Nm (90 - 100 IN.lbs.)

Model Numbers
DSG-01-

-A -N

(S-)DSG-01-

-D -N

(S-)DSG-01-

-R -N

C
196.4
(7.73)
204.4
(8.05)
204.4
(8.05)

D
76.7
(3.02)
80.7
(3.18)
80.7
(3.18)

E
88.5
(3.48)
99.5
(3.92)
102.5
(4.04)

F
53
(2.09)
64
(2.52)
57.2
(2.25)

G
H
27.5 39
(1.08) (1.54)
27.5 39
(1.08) (1.54)
34
53
(1.34) (2.09)

DSG-01 Series Solenoid


Operated Directional Valves

D
29.5
(1.16)

72.5
(2.85)

The position of the Plug-in connector can be changed as


illustrated below by loosening the lock nut. After
Cable Departure
completion of the change, be sure to tighten the lock nut
with the torque as specified below.
Cable Applicable:
....
Outside Dia.
8 - 10 mm (.31 - .39 in.)
Conductor Area ....
46(1.81)
Not Exceeding 1.5 mm2 (.0023 Sq. in.)
G

For other dimensions, refer to "Terminal Box type" (Page 356).

Models with Push Button & Lock Nut


(S-)DSG-01-

- -C

AC: 132.2(5.20)
DC/R: 136.2(5.36)

Lock Nut
Press the "Push Button" then turn "Lock Nut"
clockwise. The position of the "Push Button" is held.
Be sure to loosen "Lock Nut" fully before solenoid
is energised.

SOL b

Push Button

Interchangeability in Installation Current and New Design


In ouder to achieve higher pressure, higher flow, lower pressure drop DSG-01 valves has been upgraded from the 60
design series to the 70 design series.
The figures in the table below are the comparison between the current and the new design valves.
Specifications
Design Number

Max. Flow
L/min
(U.S.GPM)

Max. Operating
Pressure
MPa (PSI)

Max. T-Line
Back Pres.
MPa (PSI)

New Design: 70

100(26.4)

35(5080)

21(3050)

Current Design: 60

63(16.6)

31.5(4570)

16(2320)

Flow Rate: 60 L/min (15.9 U.S.GPM), Viscosity: 30

mm2/s

Pressure Drop
MPa (PSI)
{PA}

Max. Changeover
Frequency
Cycle/min (min1)
300
(R Type sol. Only 120)

Mass kg (lbs.)
3C /2D

2B

0.9(130)

1.85(4.08)

1.4(3.09)

1.0(145)

2.2(4.85)

1.6(3.53)

(141 SSU), Spool type "2" (Closed centre)

Interchangeability in Installation
Interchangeability in installation in maintained though there are minor differences in demension as in the following table.
A
E

Coil Type

AC

38
(1.50)

K
J
B

A100

SOL b

SOL a

27
(1.06)

DC
R

Design
Number
New Design
: 70

196.4 142.2 46
88.8
95
50.7
26
70
13.5 70.5
(7.73) (5.60) (1.81) (3.50) (3.74) (2.00) (1.02) (2.76) (.53) (2.78)

Current Design 191.4 142.7 48


90.3
90
50.7 23.5
65
11
72
: 60
(7.54) (5.62) (1.89) (3.56) (3.54) (2.00) (.93) (2.56) (.43) (2.83)
New Design
: 70

204.4 146.2 46
88.8
95
54.7
26
70
13.5 70.5
(8.05) (5.76) (1.81) (3.50) (3.74) (2.15) (1.02) (2.76) (.53) (2.78)

Current Design 210 152


48
90.3
90
60
23.5
65
11
72
: 60
(8.27) (5.98) (1.89) (3.56) (3.54) (2.36) (.93) (2.56) (.43) (2.83)

DSG-01 Series Solenoid Operated Directional Valves

357

Details of Receptacle
Type of
Electrical Conduit
Connection

Double Solenoid Type

Single Solenoid Type

Power Supply
(For SOL.a)

Power Suppl y

Power Supply
(For SOL.b)

SOL. a

SOL. b

Ground

Indicator Light

Terminal
Box Type

Common Plate

SOL. b

Indicator Light

Indicator Light

Common

Ground

Ground

Ground
1
1

Plug-in
Connector
Type

1-Power Suppl y

2-Power Suppl y

1. There are two grounding terminals. You can use either one.
2. If you do not need the common plate, remove it.
3. With DC solenoids, polarity is no question.

DANGER
Do not perform wiring while the power is on.
Doing so may result in electric shock, burns or death.
Make the wiring properly. Improper wiring will cause an
irregular movement of the machine, resulting in a grave
accident.

Electrical Circuit
Type of
Electrical Conduit
Connection

Electric Source
AC

ACDC Rectified

DC

Indicator Light

Indicator Light

Power
Supply

Power
Supply

Terminal
Box Type

Power
Supply

SOL.
Common
Ground

SOL.
Common
Ground

Voltage-Surge
Suppressor

SOL.
Common
Ground

Indicator Light
(Integrated in "N1"
model only)

Plug-in
Connector
Type

1-Power
Supply

1-Power
Supply

2-Power
Supply

2-Power
Supply

2-Power
Supply

Ground

Ground

SOL.

Indicator Light
(Integrated in "N1"
model only)

358

Rectifier
Circuit

Voltage-Surge
Suppressor

SOL.
1-Power
Supply

Indicator Light
Voltage-Surge
Suppressor

SOL.

Ground
Voltage-Surge
Suppressor
(Circuit composed
in coil)

DSG-01 Series Solenoid Operated Directional Valves

Rectifier
Circuit

DIRECTIONAL CONTROLS
List of Seals
-DSG-01-

- -70/7090

Spring Offset type

28
16

18

12

17
19

14

29

13

10

15

30
9
7

SOL b

SOL a

6
8

27

24

25

21

23

20

26

22

11

-DSG-01-

- -N/N1-70/7090
16 15 14

18

11

SOL a

19

SOL b

List of Seals
Item

Name of Parts

Part Numbers

O-Ring

SO-NB-A-012 (NBR, Hs90)

O-Ring

SO-NB-P18

18

Packing

19

O-Ring

24
25

Qty.
3C

2D

2B

1790S-VK421290-8

S6

O-Ring

AS 568-026 (NBR, Hs70)

O-Ring

SO-NB-P18

26

O-Ring

SO-NA-P20

27

O-Ring

SO-NA-P4

30

Plug

Remarks

DSG-01 Series Solenoid


Operated Directional Valves

1790S-VK418329-9

Included in Solenoid Ass'y (Item 11)

When ordering the O-Rings, please specify the seal kit number from the table below.
Valve Model Numbers

Seal Kit No.

O-Ring Details for Seal Kit

-DSG-01-

- -70/7090

KS-DSG-01-70

8 (4 Pcs.), 9 & 25 (2 Pcs., see above), 27 (4 Pcs.)

-DSG-01-

- -N-70/7090

KS-DSG-01-N-70

8 (4 Pcs.), 9 & 25 (2 Pcs., see above)

Solenoid Ass'y, Coil, Receptacle and Connector Refer to page 360 for the details of these parts.

DSG-01 Series Solenoid Operated Directional Valves

359

Solenoid Ass'y, Coil, Receptacle and Connector Ass'y No.

Valve Model Numbers


DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01S-DSG-01S-DSG-01S-DSG-01S-DSG-01S-DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01S-DSG-01S-DSG-01S-DSG-01S-DSG-01S-DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01S-DSG-01S-DSG-01S-DSG-01-

-A100-70
-A120-70
-A200-70
-A240-70
-D12-70
-D24-70
-D48-70
-R100-70
-R200-70
-D12-70
-D24-70
-D48-70
-R100-70
-R200-70
-A100-N-70
-A120-N-70
-A200-N-70
-A240-N-70
-D12-N-70
-D24-N-70
-D48-N-70
-R100-N-70
-R200-N-70
-D12-N-70
-D24-N-70
-D48-N-70
-R100-N-70
-R200-N-70
-A100-N1-70
-A120-N1-70
-A200-N1-70
-A240-N1-70
-D12-N1-70
-D24-N1-70
-D48-N1-70
-D12-N1-70
-D24-N1-70
-D48-N1-70

11

20

Solenoid Ass'y No.

Coil No.

SA1-100-70
SA1-120-70
SA1-200-70
SA1-240-70
SD1-12-70
SD1-24-70
SD1-48-70
SR1-100-70
SR1-200-70
SD1-12-S-70
SD1-24-S-70
SD1-48-S-70
SR1-100-S-70
SR1-200-S-70
SA1-100-N-70
SA1-120-N-70
SA1-200-N-70
SA1-240-N-70
SD1-12-N-70
SD1-24-N-70
SD1-48-N-70
SR1-100-N-70
SR1-200-N-70
SD1-12-S-N-70
SD1-24-S-N-70
SD1-48-S-N-70
SR1-100-S-N-70
SR1-200-S-N-70
SA1-100-N-70
SA1-120-N-70
SA1-200-N-70
SA1-240-N-70
SD1-12-N-70
SD1-24-N-70
SD1-48-N-70
SD1-12-S-N-70
SD1-24-S-N-70
SD1-48-S-N-70

C-SA1-100-70
C-SA1-120-70
C-SA1-200-70
C-SA1-240-70
C-SD1-12-70
C-SD1-24-70
C-SD1-48-70
C-SR1-100-70
C-SR1-200-70
C-SD1-12-70
C-SD1-24-70
C-SD1-48-70
C-SR1-100-70
C-SR1-200-70
C-SA1-100-N-70
C-SA1-120-N-70
C-SA1-200-N-70
C-SA1-240-N-70
C-SD1-12-N-70
C-SD1-24-N-70
C-SD1-48-N-70
C-SR1-100-N-70
C-SR1-200-N-70
C-SD1-12-N-70
C-SD1-24-N-70
C-SD1-48-N-70
C-SR1-100-N-70
C-SR1-200-N-70
C-SA1-100-N-70
C-SA1-120-N-70
C-SA1-200-N-70
C-SA1-240-N-70
C-SD1-12-N-70
C-SD1-24-N-70
C-SD1-48-N-70
C-SD1-12-N-70
C-SD1-24-N-70
C-SD1-48-N-70

13
Receptacle
Part No.

18
Connector Ass'y
Part No.

Remarks

R1-70

KR1-A-70
Terminal
Box
Type

KR1-B-70
RR1-70
KR1-A-70
KR1-B-70
RR1-70

GDM-211-A-11

GDM-211-B-11

Plug-in
Connector
Type
GDME-211-R-A-10 GDME-211-R-B-10

GDM-211-A-11

GDM-211-B-11

GDME-211-R-A-10 GDME-211-R-B-10

GDML-211-1-11

GDML-211-2-11
GDML-211-3-11
GDML-211-1-11
GDML-211-2-11
GDML-211-3-11
GDML-211-1-11

Note: The connector assembly is not included in the solenoid assembly.

360

19
Connector Ass'y
Part No.

DSG-01 Series Solenoid Operated Directional Valves

GDML-211-1-11

GDML-211-2-11
GDML-211-3-11
GDML-211-1-11
GDML-211-2-11
GDML-211-3-11
GDML-211-1-11

Plug-in
Connector
with
Indicator
Light

You might also like