Hotel card-inserter for central air conditioner

Installation and operation manual


Available model: MD-NIM05 !Thank you very much for purchasing our product. Before using
MDV07IU-020AW 202000170930

Safety precautions
! Read the safety precautions carefully before installing the unit. ! Following contents are for danger prevention, please keep these in mind.

Miscellaneous
About the installation site Do not install the unit in a place with much oil, steam, sulfide gas. Otherwise, the product may deform and fail. Preparation before installation 1.Check whether the following assemblies are complete.
No Name Hotel card-inserter Fastening cross groove round head wooden screw Fastening cross groove pan head self-tapping screw Installation manual Quantity Remarks MD-NIM05 M4X20 DG950-86 zinc electroplating with iridescent yellow chromate conversion coating(applied if the unit is installed on a wall) M4X25 DG950-86 zinc electroplating with iridescent yellow chromate conversion coating(applied if the unit is installed on an electrician switch box)

Warning Note

Means improper handling may lead to personal death or severe injury.

Means improper handling may lead to personal injury or property loss.

1 2

1 3

Warning
Please entrust the distributor or professionals to install the unit.
Installation by other persons may lead to imperfect installation, electric shock or fire.

3 4

3 1

Adhere to this installation manual.


Improper installation may lead to electric shock or fire.

Reinstallation must be performed by professionals.


Improper installation may lead to electric shock or fire.

2. Prepare the following assemblies on the site.


No Name 5-core shielded cable Switch box Wiring pipe (insulation casing pipe and locking screw) Quantity (embedded into/onto wall) 1 1 Specifications (for reference only) RVVP-0.5mm x5
2

Remarks The wire is 80m as a maximum

Do not uninstall the unit randomly.


Random uninstalling may lead to abnormal operation, heating or fire of the central heating water unit. 1 2

Note
Do not install the unit in a place vulnerable to leakage of flammable gases.
Once flammable gases are leaked and left around the wire controller, fire may occur.

Notes to installation of hotel card-inserter: 1. This manual describes the procedure of installing and usage of the hotel card-inserter. For connection among the hotel card-inserter, wire controller and the main unit, see the wiring diagram in this installation manual. Install the connected 5-place terminal at the specified location in the KJR-10B WIRE control box, and connect the wires according to the identification. The hotel card-inserter is a low-voltage circuit. It cannot contact the 220V mains supply or the high-voltage wire of higher than 380V directly. Do not put the foregoing circuit into the same wiring pipeline. The interval of the wire pipelines must be at least 300~500mm. The connective shielded wire of the hotel card-inserter must be grounded reliably. No joint or extension is allowed in the middle of the connection of the hotel card-inserter. After the hotel card-inserter is connected, do not use a megohmmeter to inspect insulation.

The wiring shall adapt to the wire controller current.


Otherwise, electric leakage or heating may occur and result in fire.

2. 3. 4. 5. 6.

The specified cables shall be applied in the wiring. No external force may be applied to the terminal.
Otherwise, wire cut and heating may occur and result in fire.

Installation procedure
The wiring procedure and principles are shown in the figure:

WIRE CONTROLLER
White Black Red Orange Blue

To CN1 of hotel card-inserter CN


White Black Red Orange Blue

cable A

E D To 10B B C wire B controller A


CN2 RUN

GND

COM1

CN2

To Cn2 of hotel card-inserter CN


Brown Red Black Yellow

CN1 CN1

MD-NIM05
Black Gray White Brown Red Yellow Blue Orange Green Purple Purple Green Orange Blue Yellow Red Brown White Gray Black

TO DISPLAY OF INDOOR UNIT

cable B

TO CONTROL BOARD OF INDOOR UNIT

Note

!Too may lead to deformation of the cover of the tight screw rear and cracking LCD.
allow for removing hotel card-inserter switch board in case of maintenance.
Reserve a redundant length of the connection cable for the hotel card-inserter to

Installation description:
When air conditioner required to be controlled by hotel card-inserter, however, it is unnecessary to connect KJR-10B wire controller. ON/OFF signal in COM1 and GND input terminals of hotel card-inserter is +5V weak DC current, therefore, it is unnecessary to consider wire sequence when connecting COM1 and GND terminals. In case over +5V DC current is input, hotel card-inserter would be burnt out, and even caused fire.

Operation manual
1. Connect 5-place terminal at fixed rated wire controller via 5 terminals: A, B, C, D, E. 2. Connect LCD at main control panel of indoor unit via terminals REV, C, D, E. 3. Upon wring according to the wring diagram in Installation and Operation Manual, Please power to the wire controller and switch on it. When card has been inserted between in COM1 and GND, air conditioner is turn on and its operation mode could be set, the director lamp at wire controller is light-up. 4. When no card has been inserted between in COM1 and GND (i.e. It not be short connected), the ON/OFF button of wire controller cannot start air conditioner, but two beeps of air conditioner closed down signals be giving out and no lamp is light-up at wire controller. 5. User must apply wire controller to turn on air conditioner and set operation modes every time power is input. After then, operation modes of this performance would be memorized, although took off card and than insert it on again, as long as power does not be cut off from main unit. i.e. air conditioner will turn off when card is took off, while insert it on again unit will perform as per the last setting. However the first start-up of main unit and mode setting must apply wire controller. 6. System can receives signal delivering from fixed rated wire controller (KJR-10B), and transits the signal to indoor unit; it can also memorizes the latest ON/OFF information sending by wire controller (Timing information be transited but memorized.) 7. Upon powered to card-inserter, transited signal defaults as unit shutdown. Once take off the card, system will send signal of unit shutdown twice; till to the next time card is inserted, system will not start unit until 3 seconds later, because of memory information delivery.