This guide gives an overview of common tasks that can be performed with the spectrophotometer. For more information, see the Evolution 200 Series User Guide or INSIGHT Help. Navigation pane User group
Spectrophotometer Components
Reference compartment Optional touchscreen
Task buttons
Application buttons
Template list
Task Buttons
The main task buttons provide access to basic operations: Sample compartment Keypad
Button Description
Local Control
To set up a Local Control instrument
Accesses applications and user groups for customizing the Home screen. Provides tools for storing and retrieving data. Controls how users interact with the software. Accesses system-wide settings, including accessory alignment, instrument calibration and firmware updating.
1. Turn on the power switch on the back of the spectrophotometer. 2. Press the Power button on the keypad. Wait for the system to initialize. The power indicator on the keypad stops blinking when initialization is complete and INSIGHT software appears on the screen.
Computer Control
To set up a Computer Control instrument
1. Turn on the power switch on the back of the spectrophotometer. Wait for the system to initialize. The power indicator on the keypad stops blinking when initialization is complete. Turn on the computer. Install INSIGHT software. Connect the instrument to the computer using a USB cable. Double-click the INSIGHT desktop icon to start the software.
Right Pane
The right pane in Home includes:
Feature Description
2. 3. 4. 5.
INSIGHT Window
At the left side of the INSIGHT window is the navigation pane, which contains task and action buttons. The right pane provides access to applications and data acquisition setup parameters. Above the panes is a menu bar that includes features for working with workbooks, getting help and performing data analysis and export.
Select a user group to access its applications. Click a button to open an application. To open a template, double-click its name.
Revision A 269-261800 2010 Thermo Fisher Scientific Inc. All rights reserved.
Applications
Fixed
Measures light passing through the sample at one or more wavelengths. Click the Fixed button in the right pane in Home. 4. Click . 5. Follow the instructions that appear, providing information or installing a blank, sample or standard. The acquired data appears in the right pane:
Scan
Measures light that passes through the sample over a range of wavelengths. Click the Scan button in the right pane in Home.
Quant
Use this to set up and perform quantitative analyses of sample data. Click the Quant button in the right pane in Home.
Rate
Use this to make time-based kinetics measurements. Click the Rate button in the right pane in Home. To create a report containing the data, use the next procedure.
Reports
To create and print a report
Keypad Operation
Button Function
1. Click
Confirm highlighted choices in menus and text entry boxes. Perform measurements specified using the current settings. Stop the current operation.
2. Use the Configuration tab to specify what to include in the report. 3. Use the Print tab to lay out the report.
4. Click
Data Storage
To open saved data and the associated application
1. Click
Turn the instrument on or off (press and hold 4 seconds to power off ). Start a predefined instrument function or CUE.
Instrument Performance
To verify instrument performance
Common Tasks
Start the INSIGHT software, display the Home screen, and select the Classic group before beginning the first task.
1. Click
2. Select the tests to run. Some tests require reference materials. If using an accessory, see its documentation for instructions.
Data Acquisition
To measure samples
3. Click
4. Follow the instructions that appear. Test results are saved and appear in a window from which they can be printed or copied. They can also be accessed later on the PV Reports tab in My Data.
2. Click