IV B.Tech. (CCC) Regular Examinations, December 2008 ADVANCED STRUCTURAL ENGINEERING (Civil Engineering) Time: 3 hours Max Marks:100 Answer any FIVE Questions All Questions carry equal marks

1. Design an RC slab culvert for a national highway to suit the follwing data a twolane carriage way (7.5 m wide) footpaths on either side (1 m wide) Clear span = 6m Wearing coat = 80mm Width of the bearing = 0.4m Materials : M 20 grade concrete Fe 415 grade HYSD bars. Loading : IRC class AA tracked vehicle Design the RC deck slab and sketch the details of reinforcements in the longitudinal and cross-sections of the slab. [20] 2. An RC T-beam Girder bridge is having the following data. Clear width of road way 7.5m Span (c/c of bearing ) 14.5m Live load IRC class AA tracked vehicle Average thickness of wearing coat 80mm. Materials M 20 and Fe 415 Using courbons method compute the design moment and shears, design the deck slab and main girder. Draw the details of reinforcement in the deck slab and main girder of T-beam girder bridge. [20] 3. A pratt truss girder through bridge is provided for single broad gauge track. The eective span of bridge is 50 m the cross girders are spaced 5m a part.The stringers are spaced 2m between center lines. 0.7Kn/m stock rails and 0.5 Kn/m check rails are provided. Sleepers are spaced at 0.5m from center to centre and are of size 2.8m X 250 mm X 250 mm. Weight of timber may be assumed 7.5Kn/m3 the main girders are provided at a spacing of 7m between their center lines. Design the central vertical and diagonal of central panel. The bridge is to carry standard main line loading. [20] 4. A deck type plate girder bridge is provided for a single broad gauge track and standard main line loading. The total span of main girder from center to center of bearing is 24m. The main girders are provided at a spacing of 1.3m between their center lines 0.6 Kn/m stock rails and 0.4 Kn/m guard rails are provided. The weight of fastenings may be taken as 0.2Kn/m the sleepers are spaced at 400 mm from centre to center and are of 2.0 m X 250 mm X 250 mm in size. The unit weight

T N

W U

R O

D L

1 of 2

www.jntuworld.com

www.jntuworld.com
Code No: C4CE02

05

of timber may be assumed as 7.5 Kn/m3 . The oor is open deck type. Design the maximum section of the main plate girder. [20] 5. A concrete chimney of height 70 m with the external diameter of the shaft being 4m at top and 5m at bottom is required in a place where the wind intensity is 1.8 Kn/m2 thickness of re brick lining = 100 mm, temperature dierence between the inside and outside of shift = 800 C, permissible bearing pressure on soil at site = 180 Kn/m2 adopt M 25 grade concrete mix and Fe 415 grade. Design the base section of the chimney. [20] 6. Design a dog-logged staircase for a public building to be located in a stair case room 6 m long and 3m wide. Use M 25 and Fe 415 steel. Height between oors = 3.6 m, live load on stairs = 6 Kn/m2 the stairs supported on beams over walls. [20] 7. Design cylindrical tank wall, bottom ring beam, conical dome of intz type water tank of 1.2 million litres capacity supported on an elevated lower comprising of 8 columns. The base of the tank is 16 m above ground level. Adopt M 25 and Fe 415 steel. [20] 8. Design an overhead riveted steel rectangular at bottom tank of capacity 7000 litres. The available width of plates is 1.22 m and lengths upto 6.1 m. The staging consists of 4 columns, spaced 4.88 m X 3.66 m and the bottom of the tank is 9.14 m above the ground level. Design the thickness of the plates, T- sections and stays. [20]

T N

W U

R O

D L

2 of 2

www.jntuworld.com

www.jntuworld.com

Code No: C4CE02

NR

JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY HYDERABAD B.Tech (CCC) IV Year Examinations February 2011 ADVANCED STRUCTURAL ENGINEERING (Civil Engineering) Time: 3 Hours Answer Any Five Questions All Questions Carry Equal Marks --1. a) b) What are the design requirements for R.C. bridges. Design a slab bridge for the following data: Clear span = 5.0 m. Clear width of road way = 6.8 m. Live loading - Class a loading. Mix used in M20. Average thickness of wearing coat = 80 mm. Max.Marks:100

2.

A reinforced concrete (single span) J- beam bridge is to consist of 5 beams 1.75 m apart the span of bridge is 12.0 m clear width end bearings of 600 mm. The L.L. on the bridge is 17000 N/mm2 including impart. The carriage way over the bridge is to be 7.0 m width with a foot path of 1.5 m width on either side. The loading on the foot path may be taken as 3900 N/m2. Design the bridge. Ux M20 concrete and Fe415 steel. [20] Design a concrete chimney of 80 m height. The external diameter of shaft is 5.0 m through out the chimney is to be designed for wind pressure in Delhi area. [20] Derive the expressions for: i) Meridional thrust ii) Hoop stress in a spherical domes.

3.

4.

5.

Design a deck type of girder Railway Bridge for broad gauge main line loading. Clear span is 20 m; Effective span = 25.0 m. Overall length is 26.0 m; Centres of piers is 26.2 m. Take fb = 147 N/mm2. [20] Design the top lateral bracing and bottom lateral bracing for the through type truss girder Railway Bridge for a single broad gauge track. The truss contains 8 panels of each 5m span and a height of 6.0 m. Subjected to UDL of 20kN/m through out the span. [20] What forces are acting on the steel chimney and explain them. Explain different types of chimneys and assumptions in steel chimneys.

T N

W U

R O

D L

[20]

[20]

6.

7. a) b) 8.

[20]

Design the staging for the rectangular over head steel tank of capacity 1, 20,000 liters. The staging consists of 6 columns. The bottom of tank is 10 m above the ground level. Take intensity of wind force is at 1500 N/m2. [20]

***** www.jntuworld.com

www.jntuworld.com

Code.No: C4CE02
JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY HYDERABAD B.Tech (CCC) IV Year Regular Examinations February 2010 ADVANCED STRUCTURAL ENGINEERING (CIVIL ENGINEERING) Time : 3 Hours Max. Marks :100 Answer Any Five Questions All Questions Carry Equal Marks --1.a) Explain what are the loads, force and tresses to be considered in designing super structure of bridges. b) Design a solid slab bridge for IRC class AA loading for the following data Clear span = 5.0 m Clear width of roadways = 7.0 m. Average thickness of wearing coat = 8.0 mm Use M20 mix. Take unit weight of concrete as 24000 N/m3. [20] 2. Explain Pigeareds theory for a girder bridge. Design a R.C T-beam for the following data Clear width of road way = 7.0 m Span centre to centre of bearings = 20.0m Live load = class AA Average thickness of wearing coat = 80 mm Use M20 concrete for deck slab and M15 concrete for beam. Take weight of concrete as 24000 N/m3. [20] What are the factors to be considered for design of a chimney? Design a chimney of 30 m height having external diameter of 2.6 m throughout the height. The chimney has a fire brick liming of 100 mm thickness mm, provide up to a height of 2 mm above base with an air gap of 100 mm. Assume the temperature of gases above the surrounding air as 2400 C. Take for R.C.C as 11 x 10-6 ph 0C and Es = 2.05 x 105 N/mm2. Use M20 grade concrete. [20]

3.

T N

W U

R O

D L

4.

Design an underground rectangular tank hmx 6 m x 2 m dup . The subsoil unit weight is 16000 N/m3 and angle of friction of 340. The subsoil water level is at a greater depth. Use M20 concrete and Fe415 steel. [20]

5.a) What are the assumption for the design of plate girder bridges? b) Explain the design principles for a maximum reaction for deck type of Railway bridges. [20]

www.jntuworld.com

www.jntuworld.com

6.

Analyze completely the bracing shown in figure carrying a lateral wall of P = 100 KN also draw B.M and S. F diagram for AD and BC.

[20]

7. Design a self supporting steel chimney of 100 m height. The diameter of cylindrical shell is 4m. The chimney has a 100 m thick brick liming supported on the shell.[20] 8. Design an elevated circular steel tank for 3,00,000 liters capacity with circular girder supported on eight number of columns. The shape of bottom may be assumed suitable. The roof and staging for the tank need not be designed. [20]

T N

W U
******

R O

D L

www.jntuworld.com

www.jntuworld.com

Code. No: C4CE02


JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY HYDERABAD B.Tech (CCC) IV Year Supplementary Examinations July - 2010 ADVANCED STRUCTURAL ENGINEERING (Civil Engineering) Time: 3 Hours Answer Any Five Questions All Questions Carry Equal Marks --1.a) b) What are the different loads acting on the bridges and explain them briefly. Design a solid slab bridge for class A loading for the following data. Clear span = 5.0 m; clear width of Road way = 7.5 m; Average thickness of Wearing coat = 80 mm. Ux M20 mix. [20] Take unit weight of concrete = 24000 N/m3. Design a T Beam Bridge for the following data: Clear width of roadway = 7.0 m. Span centre to centre of bearings = 16 m. Live load class a loading. Average thickness of wearing coat = 8 cm. Ux M20 concrete and steel Fe 415. Max.Marks:100

2.

3.

Design a concrete chimney of 40m height and 3.0m diameter throughout. The chimney is to be designed for wind pressure in Bombay area. [20] Design a circular tank having a diameter of 6.0m and height of 3m. The tank is supported on masonary tower. [20] Design a deck type of plate girder railway bridge for broad gauge main line loading, given that f b = 147 N/mm2. Clear span = 24.4 m; Effective span = 25.0 m Over all length = 25.5 m, Centres of piers = 25.6 m. [20] Draw the influence line diagram for all the members of the Pratt truss girder shown in figure. [20]

4.

5.

T N

W U

R O

D L

[20]

6.

Contd2

www.jntuworld.com

www.jntuworld.com

::2:: 7. A self supporting steel chimney is 100 m height and diameter 3.0 m. Design the plates for the stack, design the bar plate, bugs and anchor bolts. Take f b = 1000 KN/cm2. Assume that the chimney is located in Calcutta for considering wind and other parameters. [20] Design an elevated steel circular tank for 2, 40,000 liters capacity supported on eight columns. The shape of the bottom of tank may be assumed suitably. Root and staging for the tank used not be designed. [20]

8.

*****

T N

W U

R O

D L

www.jntuworld.com

Available B.Tech(CCC) Previous Question Papers with Solutions

Code. No: C4CE02


JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY HYDERABAD B.Tech (CCC) IV Year Supplementary Examinations July - 2010 ADVANCED STRUCTURAL ENGINEERING (Civil Engineering) Time: 3 Hours Answer Any Five Questions All Questions Carry Equal Marks --1.a) b) What are the different loads acting on the bridges and explain them briefly. Design a solid slab bridge for class A loading for the following data. Clear span = 5.0 m; clear width of Road way = 7.5 m; Average thickness of Wearing coat = 80 mm. Ux M20 mix. [20] Take unit weight of concrete = 24000 N/m3. Design a T Beam Bridge for the following data: Clear width of roadway = 7.0 m. Span centre to centre of bearings = 16 m. Live load class a loading. Average thickness of wearing coat = 8 cm. Ux M20 concrete and steel Fe 415. Max.Marks:100

2.

3.

Design a concrete chimney of 40m height and 3.0m diameter throughout. The chimney is to be designed for wind pressure in Bombay area. [20] Design a circular tank having a diameter of 6.0m and height of 3m. The tank is supported on masonary tower. [20] Design a deck type of plate girder railway bridge for broad gauge main line loading, given that f b = 147 N/mm2. Clear span = 24.4 m; Effective span = 25.0 m Over all length = 25.5 m, Centres of piers = 25.6 m. [20] Draw the influence line diagram for all the members of the Pratt truss girder shown in figure. [20]

4.

5.

i r

e v

c a i. n

in .

[20]

6.

Contd2

To get Test Papers Within 24 Hrs TRIVENI ACADEMY Ph: 9848581807

Available B.Tech(CCC) Previous Question Papers with Solutions

::2:: 7. A self supporting steel chimney is 100 m height and diameter 3.0 m. Design the plates for the stack, design the bar plate, bugs and anchor bolts. Take f b = 1000 KN/cm2. Assume that the chimney is located in Calcutta for considering wind and other parameters. [20] Design an elevated steel circular tank for 2, 40,000 liters capacity supported on eight columns. The shape of the bottom of tank may be assumed suitably. Root and staging for the tank used not be designed. [20]