You are on page 1of 10

Extract from the online catalog

FL BT EPA
Order No.: 2692788

http://catalog.phoenixcontact.net/phoenix/treeViewClick.do?UID=2692788

Factoryline Wireless Bluetooth Ethernet Port Adapter; Bluetooth V2.0; 2.4 GHz frequency band; 1 wireless interface; WLANBlackChannelList; country approvals; IP67, connections: M12 for 9 - 30 V DC, M12 for LAN; Autocrossing; PROFINET & Profisafecompatible

Product notes Commercial data EAN


4 046356 422413

WEEE/RoHS-compliant since: 06/16/2008

Pack Customs tariff Product key Catalog page information

1 Pcs. 85176200 CNN2B1 Page 123 (AX-2011) http:// www.download.phoenixcontact.com Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation. The General Terms and Conditions of Use apply to Internet downloads.

Product description Wireless Ethernet for the transmission of control data FL BT EPA AIR SET can thus be used to set up an extremely rugged and reliable wireless transmission path for PROFINET, Modbus/TCP, Ethernet/IP or other Ethernet protocols quickly and easily. The rugged wireless connection for the industrial automation

PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com

Page 1 / 10 Mar 29, 2012

FL BT EPA Order No.: 2692788

http://catalog.phoenixcontact.net/phoenix/treeViewClick.do?UID=2692788

The Bluetooth Ethernet Port Adapter FL BT EPA is the solution for the wireless communication connection between the automation device and the control system network irrespective of whether it is PROFINET, PROFIsafe, Ethernet/IP, Modbus-TCP or TCP/IP Factoryline Bluetooth Industrial Bluetooth provides an extremely rugged, reliable and safe wireless communication. AFH*, LEM* and BCL* ensure hassle-free parallel operation with WLAN networks. AFH: Adaptive frequency hopping; LEM: Low-emission mode; BCL: Black Channel List

Integrated special antenna: The integrated and circularly polarized antenna ensures reliable and stable reception conditions in greatly metallic environments. Install the Ethernet port adapter as an intelligent antenna directly in the field. Configuration via the mode button: Simply select an operating mode using the mode button and a stable and secure wireless connection between the two Ethernet port adapters is established automatically in a few seconds there's nothing faster or easier. Industrial Bluetooth module: Developed for use in extremely rough industrial conditions. Its features are: High-performance wireless properties, high range, large temperature range of -30C to +60C and high vibration, shock and EMC resistance. Complete control by the controller: Control all functions of the Ethernet port adapter with your application program. Whether it is configuration, scanning for networks or quick switching of access points, all commands are executed in no time. The Ethernet port adapter provides optimum flexibility. PROFINET-optimized: The Ethernet port adapter enables stable PROFINET and PROFIsafe update times from 8 ms onwards. Fulfills the PROFINET compliance class A and PROFIsafe profile 2.4 requirements for functionally secure data transmission. Technical data Ethernet interface Interface Number Connection method Wireless interface Name Wireless standard Bluetooth Bluetooth 2.0 Ethernet 1 M 12 connectors (D-coded, female)

PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com

Page 2 / 10 Mar 29, 2012

FL BT EPA Order No.: 2692788

http://catalog.phoenixcontact.net/phoenix/treeViewClick.do?UID=2692788

Frequency range Frequency band Transmission power Number of wireless interfaces Wireless modules that can be connected Profiles supported Wireless card Number Assembly instructions Antenna Assembly instructions Number Connection method Power supply for module electronics Connection method Supply voltage Supply voltage range Current consumption Functions Operating modes Configuration Automatic channel selection Security

2.402 GHz ... 2.48 GHz (ISM bandwidth) ISM 2.4 GHz max. 20 dBm (with automatic control) 1 1 PAN

1 Permanently installed

Internal circularly polarized panel antenna 1 Permanently installed

M12 connector (A-coded, male) 24 V DC 9 V DC ... 30 V DC 46 mA (at 24 V DC)

Ethernet client adapter Web-based management FHSS, AFH 128-bit data encryption Authentication PIN Non-discoverable

Digital inputs Number of inputs General data Width Height Depth 66 mm 91 mm 34 mm 1

PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com

Page 3 / 10 Mar 29, 2012

FL BT EPA Order No.: 2692788

http://catalog.phoenixcontact.net/phoenix/treeViewClick.do?UID=2692788

Note on dimensions Weight Mounting type Ambient temperature (operation) Ambient temperature (storage/transport) Permissible humidity (operation) Permissible humidity (storage/transport) Air pressure (operation) Degree of protection Protection class Conformance with EMC directives

Without M12 connections 120 g Wall mounting -30 C ... 65 C -40 C ... 85 C 5 % ... 90 % (no condensation) 5 % ... 90 % (no condensation) 795 hPa ... 1080 hPa (up to 2000 m above mean sea level) IP65 III, IEC 61140, EN 61140, VDE 0140-1 Noise immunity test in accordance with EN 61000-6-2 EN 61000-6-4

PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com

Page 4 / 10 Mar 29, 2012

FL BT EPA Order No.: 2692788

http://catalog.phoenixcontact.net/phoenix/treeViewClick.do?UID=2692788

Wireless licences

Belgium Bulgaria Denmark Germany Estonia Finland France Greece Great Britain Ireland Iceland Italy Canada Latvia Liechtenstein Lithuania Luxembourg Malta The Netherlands Norway Austria Poland Portugal Romania Sweden Switzerland Slovakia Slovenia Spain Czech Republic Hungary USA Cyprus (rep.)

PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com

Page 5 / 10 Mar 29, 2012

FL BT EPA Order No.: 2692788

http://catalog.phoenixcontact.net/phoenix/treeViewClick.do?UID=2692788

Accessories Item Designation Description

Cable/conductor 1400420 SAC-4P- 1,0-PUR/M12FS Sensor/Actuator cable, 4-position, PUR halogen-free, Black-gray RAL 7021, Free conductor end, on Socket, straight M12, A-coded, Cable length: 1 m Sensor/Actuator cable, 4-position, PUR halogen-free, Black-gray RAL 7021, Free conductor end, on Socket, straight M12, A-coded, Cable length: 2 m Sensor/Actuator cable, 4-position, PUR halogen-free, Black-gray RAL 7021, Free conductor end, on Socket, straight M12, A-coded, Cable length: 3 m Sensor/Actuator cable, 4-position, PUR halogen-free, Black-gray RAL 7021, Free conductor end, on Socket, straight M12, A-coded, Cable length: 5 m Bus system cable, Ethernet, 4-position, PUR halogen-free, water blue RAL 5021, shielded, Plug, straightLink:M12, D-coded, on Free conductor end, Cable length: 2 m Bus system cable, Ethernet, 4-position, PUR halogen-free, water blue RAL 5021, shielded, Plug, straightLink:M12, D-coded, on Free conductor end, Cable length: 5 m Assembled Ethernet cable, CAT5e, shielded, 2-pair, AWG 26 stranded (7-wire), RAL 5021 (water blue), M12 plug on RJ45 plug/ IP20, line, length 2 m Assembled Ethernet cable, CAT5e, shielded, 2-pair, AWG 26, stranded (7-wire), RAL 5021 (aqua blue), M12 connector to RJ45 connector/IP20, line, length 1 m Assembled Ethernet cable, CAT5e, shielded, 2-pair, 26 AWG, stranded (7-wire), RAL 5021 (aqua blue), M12 connector to RJ45 connector/IP20, line, length 5 m

1533576

SAC-4P- 2,0-PUR/M12FS

1668111

SAC-4P- 3,0-PUR/M12FS

1668124

SAC-4P- 5,0-PUR/M12FS

1569391

SAC-4P-M12MSD/ 2,0-931

1569401

SAC-4P-M12MSD/ 5,0-931

1406056

VS-M12MS-IP20-93E-LI/2,0

1403498

VS-MSD-IP20-93E/1,0

1403500

VS-MSD-IP20-93E/5,0

General 1656725 VS-08-RJ45-5-Q/IP20 RJ45 plug-in connector, IP20, CAT5e, 8-pos., with QUICKON fast connection technology, for 26 ... 23 AWG 1-wire and 7-wire conductors, for 4.5 mm ... 8.0 mm cable diameter, labeling: TIA 568 B, color: gray

Software 2692254 FL WST BASIC Simulation software for supporting the planning of wireless systems in industrial environments. Thus, the later number and position of wireless components can be estimated and the quality of the radio coverage simulated. Simulation software for supporting the planning of wireless systems in industrial environments. Their functionality is limited with regard to the memory options as compared with the full version FL WST BASIC.

2692377

FL WST BASIC DEMO

PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com

Page 6 / 10 Mar 29, 2012

FL BT EPA Order No.: 2692788

http://catalog.phoenixcontact.net/phoenix/treeViewClick.do?UID=2692788

Drawings Application drawing FL BT EPA devices help you to transmit industrial Ethernet protocols from one automation device to another via Bluetooth: for Modbus TCP, Ethernet/IP, TCP/IP or demanding PROFINET or PROFIsafe applications. The FL BT EPA AIR SET is a "ready to use" package. Unpack, connect, press the mode button and the wireless path is ready to work in just a few seconds! The FL BT EPA AIR SET can be used to set up an extremely solid and reliable wireless transmission path.

Diagram Antenna adjustment diagram HP - Horizontal polarization VP - Vertical polarization

Functional drawing Circular polarized antenna

PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com

Page 7 / 10 Mar 29, 2012

FL BT EPA Order No.: 2692788

http://catalog.phoenixcontact.net/phoenix/treeViewClick.do?UID=2692788

Dimensioned drawing

Product drawing 1 Fixing holes 2 Internal circular polarized antenna 3 Status and diagnostic indicators 4 Link quality and configuration / status indicator 5 Mode configuration button 6 LAN interface 7 Supply voltage connection

PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com

Page 8 / 10 Mar 29, 2012

FL BT EPA Order No.: 2692788

http://catalog.phoenixcontact.net/phoenix/treeViewClick.do?UID=2692788

Schematic diagram

Connection of the trigger input DI and the supply voltage PIN 1 Vin + (9-30 V DC) PIN 2 External Trigger Ground Pin 3 Vin GND (0 V) Pin 4 External Triggerr + (9-30 V DC) Pin 5 n.c.

Assignment of the LAN socket Pin 1 Transmit + Pin 2 Receive + Pin 3 Transmit Pin 4 Receive -

Status and diagnostic indicators PWR (green) - Supply voltage is active ))) (blue/blue flashing, pink, red) Status of the Bluetooth connection (blue) - Data transmission (blue flashing) - Connection establishment (pink) - Error (red) LAN (yellow) - Link display (yellow) - Data transmission (yellow flashing)

MODE button The mode button helps in configuration. Pay attention to the function in the data sheet and the manual. The LEDs "A" to "D" help in status display. Link Quality display (during operation) A = sufficient, B = good C = optimum, D = excellent

PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com

Page 9 / 10 Mar 29, 2012

FL BT EPA Order No.: 2692788

http://catalog.phoenixcontact.net/phoenix/treeViewClick.do?UID=2692788

Address

PHOENIX CONTACT GmbH & Co. KG Flachsmarktstr. 8 32825 Blomberg,Germany Phone +49 5235 3 00 Fax +49 5235 3 41200 http://www.phoenixcontact.com

2012 Phoenix Contact Technical modifications reserved;

PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com

Page 10 / 10 Mar 29, 2012

You might also like