You are on page 1of 33

Uses Tee The (intake bell) fits inside SDR.35-6" spigot, fairly well.

5" (tile bell) fits over 4" bell end of SDR.26, SDR.21 and Sch 40, fair to loose. 5" (tile bell) fits inside 6" bell end of SDR.35 very well. 5" (tile bell) fits on 5" spigot end of Sch 40, SDR.21 and SDR.26 fairly well. 5" (intake bell) will fit 5" Fernco plastic adapter. 5" (tile bell) will fit 6" Fernco plastic adapter. You can use a Hancor 5"x4" reducer which will snap directly into (tile bell) end of tee and snap over 4" tile to be used. Product #FC-R04-05 8. You can use an A.D.S. 5"x4" external reducer but will have to use a piece of 5" tile to connect the reducer and tee. Product #0514AA 9. You can use a Hickenbottom 5"x4" reducer, but will also need a piece of 5" tile to connect the reducer to the tee. Product #HBI-504 10. PCX 56-64 (Fernco) will fit over bell of tee and connect it to 4" PVC pipe. We have all the adapters described above available for your convenience. 1. 2. 3. 4. 5. 6. 7.

Stacks 1. 5" stack bell or spigot end will fit 5" Fernco plastic adapter fairly well. 2. You can use a 5" Internal Coupler in the spigot end of stack to connect to 5" tile or to repair an existing 5" intake. (Also a A.D.S. 6"x5" internal reducer will work to connect to 6" field tile.) Product #0526AA Please refer to CFS chart for further flow capacities.

Part Description HBI-5510 Section contains 24 each 1" holes per foot and is used in standard conditions with 4" and 5" and sometimes 6" tile where the flow of a 6" intake is not needed. (Refer to CFS chart for flow capacities and tile drainage chart or contact your local Soil Conservation Office.) Section is the same as HBI-5510 but in section. A 5" x 1" holed section with 3 each 1" x 4" slots per foot. It is used to provide more flow than a 5" x 1" section can provide and where a 6" x 1" section is too much. It can also be used in conjunction with a 5" restrictor to help eliminate trash build up due to possible restriction of the 1" holes. A 5" x 1" holed section with the top half fully slotted. This was designed to provide maximum flow for the upper half of the inlet without having to use a wire trash rack or Bar Guard. The lower half has 1" holes to provide the standard flow release for remaining water in the terrace.

HBI-5121 HBI-55SL

HBI-5FSL

5-Inch Intake Description & Use: Part Description (continued)

HBI-5516

A 5" x 5/16" holed orange section used underground from the tee as a riser extension. It can be cut at different locations (as marked on the section) to adjust the height of the intake. Section is the same as the HBI-5516 but in 1/2 section. 5" Intake Part Description continued... Section is a standard blank section, currently made in the color orange, and is blind on both ends. It can also be used in place of HBI-5516 where no small holes are wanted below ground. This can only be used in the vertical position. Section is the same as the above but in half section. A 5" short tee. Excepts a 5" field tile into the bell only or a 5" x 4" reducer. A 5" x 4" reducer used to adapt the 5" intake tee so it an be connected to the 4" corrugated tile. It will take a small length of 5" corrugated tile to connect the tee to the reducer. A 5" restrictor used to adjust the flow of water from the intake to the main line. Contact your local SCS office for proper hole size in the restrictor. A 5" x 1" section with the bottom left blind which can act as a built in restrictor. Removing the section and changing restrictor hole size with a saw can easily change it.

HBI-5125 HBI-55BL

HBI-512B HBI-5BTS HBI-5440

HBI-50R0

HBI-5SBO

Uses New Style Tee 1. 6" (tile bell) fits over 6" SDR.35 bell a little sloppy. 2. 6" (tile bell) fits over 6" DR.-C900 spigot very good. 3. You can use our Product #HBI-654 reducer to connect 6" intake tee to 6" field tile. The reducer will fit directly into the bell of our tee. 4. You can also use Hancor's 6" x 5" reducer, Product #FC-R05-06, or their 6" x 4" reducer Product #FC-R04-06, both will fit directly into our intake tee bell. 5. You can use most other 6" reducers made but may have to use a piece of 6" field tile to connect the tee to the tile.

Stacks 1. The spigot of the 6" stack will fit all 6" SDR.35 bell end fittings. 2. The 6" stack bell will fit inside the 6" Schedule 40 bell but you will have to cut off the bell below the rib on the bell in order to get the 6" Schedule 40 bell to go over the 6" stack bell. 3. The 6" stack spigot fits the Fernco plastic adapter. Please refer to CFS chart for further flow capacities.

Part Description HBI-6610 Section contains 40 each 1" holes per foot and is used in standard conditions with 4", 5" and 6" tile and sometimes 8" where the flow of an 8" intake is not needed. (Refer to the CFS chart for flow capacities and tile drainage chart or contact your local Soil Conservation Office.) Section is the same as HBI-6610 but in 1/2 section. A 6" x 1" holed section with 5 each 1" x 4" slots per foot. It is used to provide more flow than a 6" x 1" section can provide and where an 8" x 1" section is to much. It can also be used in conjunction with a 6" restrictor to help eliminate trash buildup due to possible restriction of the 1" holes. A 6" x 1" holed section with the top half fully slotted. This was designed to provide maximum flow for the upper half of the inlet without having to use a wire trash rack or Bar Guard. The lower half has 1" holes to provide the standard flow release for remaining water in the terrace. A 6" x 5/16" holed orange section used underground from the tee as a riser extension. It can be cut at different locations (as marked on the section) to adjust the height of the intake. Section is the same as HBI-6516 piece but in 1/2 section.

HBI-6121 HBI-66SL

HBI-6FSL

HBI-6516

HBI-6125

6-Inch Intake Description & Use: Part Description (continued)

HBI-66BL

Section is a standard blank section, currently made in the color orange, and is blind on both ends. It can also be used in place of HBI-6516 where no small holes are wanted below ground. It can only be used in the vertical position. Section is the same as HBI-66BL but in 1/2 section. A 6" blind tee that will connect directly to a 6" corrugated tile by inserting the tile into the tile bell of the tee. A 6" x 5" New Style tee to be used to connect directly to 6" corrugated tile and has a 5" inlet bell so that a 5" intake section can be snapped directly into the tee with out the use of an adapter. Used to connect a 6" New Style tee (HBI-6BTNS) to 4" corrugated tile. It inserts directly into the tile bell of the reducer. It can be cut off to fit 5" corrugated tile also. This makes this reducer completely universal as a 6" x 5" reducer and a 6" x 4" reducer. Used to connect a 6" New Style tee (HBI-6BTNS) to 5" corrugated tile. It inserts directly into the tile bell of the New Style tee and the 5" corrugated tile inserts into the bell of the reducer. A 6" restrictor used to adjust the flow of water from the intake to the main line. Contact your local SCS office for proper hole size in the restrictor. A 6" x 1" section with the bottom left blind which can act as a built in restrictor. Removing the section and changing restrictor hole size with a saw can easily change it. Section is an approximate 3' of dual wall, currently made in the color black, and is open on both ends. Standard use is to offset the intake from the main line.

HBI-612B HBI-6BTN

HBI-65BT

HBI-6540

HBI-6550

HBI-60R0

HBI-6SBO

HBI-66BLN

Uses New Style Tee (HBI-8BTN) 1. The 8" intake tee bell fits the bell of the 8" SDR.35 loosely, but would work if necessary. 2. The tee bell fits over the bell of the 8" Schedule 40 fairly tight. 3. The 8" tee bell fits inside of a #1056-1010, plastic to plastic, Fernco coupler.

Stacks 1. The spigot of the 8" stack will fit all bells of 8" Schedule 40, SDR.21 and SDR.26. 2. The spigot of the 8" stack will fit inside of the Fernco 8" plastic adapter. Please refer to CFS chart for further flow capacities.

Part Description HBI-8810 Section contains 56 each 1" holes per foot and is used in standard conditions where an 8" intake is needed for capacity. (Refer to the CFS chart for flow capacities and tile drainage chart or contact your local Soil Conservation Office.) Section is the same as HBI-8810 but in 1/2 section of approximately 19" length. An 8" x 1" holed section with 8 each 1" x 4" slots per foot. It is used to provide more flow than a 8" x 1" section can provide and where an 10" x 1" section is to much. It can also be used in conjunction with a 6" restrictor to help eliminate trash buildup due to possible restriction of the 1" holes. A 8" x 1" holed section with the top half fully slotted. This was designed to provide maximum flow for the upper half of the inlet without having to use a wire trash rack or Bar Guard. The lower half has 1" holes to provide the standard flow release for remaining water in the terrace. A 8" x 5/16" holed orange section used underground from the tee as a riser extension. It can be cut at different locations (as marked on the section) to adjust the height of the intake. Section is the same as HBI-8516 piece but in 1/2 section of approximately 19" length.

HBI-8121 HBI-88SL

HBI-8FSL

HBI-8516

HBI-8125

8-Inch Intake Description & Use: Part Description (continued)

HBI-88BL

Section is a standard blank section, currently made in the color orange, and is blind on both ends. It can also be used in place of HBI-8516 where no small holes are wanted below ground. It can only be used in the vertical position. Section is the same as HBI-88BL but in 1/2 section of approximately 19" length. An 8" (New Style Tee) which can be connected directly to 8" corrugated tile or dual wall. An 8" restrictor used to adjust the flow of water from the intake to the main line. Contact your local SCS office for proper hole size in the restrictor. Section is 8" x 8" x 8". Two ends are blind and are marked for different sizes of corrugated tile. A 8" x 1" section with the bottom left blind which can act as a built in restrictor. Removing the section and changing restrictor hole size with a saw can easily change it. Section is an approximate 3' of dual wall, currently made in the color black, and is open on both ends. Standard use is to offset the intake from the main line.

HBI-812B HBI-8BTN HBI-80R0

HBI-888Y HBI-8SBO

HBI-88BLN

Uses New Style Tee (HBI-10BTN) 1. The 10" intake tee bell fits tight over SDR.35 10" belled end. 2. The 10" intake tee bell fits tight on the bell of Schedule 40 10". 3. The 10" tee bell fits inside of a #1056-1212, plastic to plastic, Fernco coupler.

Stacks 1. The 10" intake stack bell will fit over 10" SDR.35 spigot and 10" Schedule 40, SDR.21 and SDR.26 spigots fairly well. Please refer to CFS chart for further flow capacities.

Part Description HBI-1010 Section contains 72 each 1" holes per foot and is used in standard conditions where a 10" intake is needed for capacity. (Refer to the CFS chart for flow capacities and tile drainage chart or contact your local Soil Conservation Office.) Section is the same as HBI-1010 but in 1/2 section of approximately 19" length. A 10" x 1" holed section with 8 each 1" x 4" slots per foot. It is used to provide more flow than a 10" x 1" section can provide and where a 12" x 1" section is too much. It can also be used in conjunction with a 10" restrictor to help eliminate trash buildup due to possible restriction of the 1" holes. A 10" x 1" holed section with the top half fully slotted. This was designed to provide maximum flow for the upper half of the inlet without having to use a wire trash rack or Bar Guard. The lower half has 1" holes to provide the standard flow release for remaining water in the terrace. A 10" x 5/16" holed orange section used underground from the tee as a riser extension. It can be cut at different locations (as marked on the section) to adjust the height of the intake. Section is the same as HBI-10516 piece but in 1/2 section of approximately 19" length. Section is a standard blank section, currently made in the color orange, and is blind on both ends. It can also be used in place of HBI-10516 where no small holes are wanted below ground. It can only be used in the vertical position. Section is the same as HBI-10BL but in 1/2 section of approximately 19" length.

HBI-10121 HBI-10SL

HBI-10FSL

HBI-10516

HBI-10125 HBI-10BL

HBI-1012B

10-Inch Intake Description & Use: Part Description (continued)

HBI-10BTN HBI-10R0

A 10" (New Style Tee) which can be connected directly to 10" corrugated tile or dual wall. A 10" restrictor used to adjust the flow of water from the intake to the main line. Contact your local SCS office for proper hole size in the restrictor. This part is currently built in on the HBI-1010. This part is custom made for any other piece at this time. A 10" x 1" section with the bottom left blind which can act as a built in restrictor. Removing the section and changing restrictor hole size with a saw can easily change it. Section is an approximate 3' of dual wall and is open on both ends. Standard use is to offset the intake from the main line.

HBI-10SBO

HBI-10BLN

Uses Tee 1. The bell of the 12" intake tee fits very tightly over the outside of the SDR.21 and SDR.26 gasketed bell ends. Please refer to CFS chart for further flow capacities.

Part Description HBI-1210 Section contains 72 each 1" holes per foot and is used in standard conditions with 12" tile where a 12" x 1" flow rate is needed. This unit can also be fitted with 72 each 1 1/4" holes or 72 each 1 1/2" holes or 72 each 1 1/2" holes. These are special size holes and must be requested. There will be an added charge for these size changes. (Refer to the CFS chart for flow capacities and tile drainage chart or contact your local Soil Conservation Office.) Section is the same as HBI-1210 but in 1/2 section of approximately 44" length. A 12" x 1" holed section with 12 each 1" x 4" slots per foot. It is used to provide more flow than a 12" x 1" section can provide and where a 15" x 1" section is too much. It can also be used in conjunction with a 12" restrictor to help eliminate trash buildup due to possible restriction of the 1" holes. A 12" x 1" holed section with the top half fully slotted. This was designed to provide maximum flow for the upper half of the inlet without having to use a wire trash rack or Bar Guard. The lower half has 1" holes to provide the standard flow release for remaining water in the terrace. A 12" x 5/16" holed orange section used underground from the tee as a riser extension. It can be cut at different locations (as marked on the section) to adjust the height of the intake. Section is the same as HBI-12516 piece but in 1/2 section of approximately 21" length. Section is a standard blank section, currently made in the color orange, and is blind on both ends. It can also be used in place of HBI-12516 where no small holes are wanted below ground. It can only be used in the vertical position. Section is the same as HBI-12BL but in 1/2 section of approximately 21" length. A 12" tee designed to connect directly to 12" corrugated tile or dual wall. A 12" restrictor used to adjust the flow of water from the intake to the main line. Contact your local SCS office for proper hole size in the restrictor. This part is currently built in on the HBI-1210. This part is custom made for any other piece at this time.

HBI-12121 HBI-12SL

HBI-12FSL

HBI-12516

HBI-12125 HBI-12BL

HBI-1212B HBI-12BT HBI-12R0

12-Inch Intake Description & Use: Part Description (continued)

HBI-12SBO

A 12" x 1" section with the bottom left blind which can act as a built in restrictor. Removing the section and changing restrictor hole size with a saw can easily change it. Section is an approximate 3' of dual wall and is open on both ends. Standard use is to offset the intake from the main line.

HBI-12BLN